Test Reportt

FCC ID: 2ACO3-17831

Test Report

Download: PDF
FCCID_4120006

                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch

                                                                     Report No.: SZEM181200018901
                                                                     Page:        1 of 17


                                    TEST REPORT
Application No.:                SZEM1812000189CR(SGS SZ No.:T51810300010EM)
Applicant:                      Lucky Group(H.K.) Limited
Address of Applicant:           Building B, Lucky Industrial Park, Hongjin Road, Hongmei Town, Dongguan,
                                China
Manufacturer:                   Shenzhen WUDOUMI Electronics Technology Co., Ltd
Buyer:                          D&B
Supplier:                       Lucky Group (H.K.) Limited
Equipment Under Test (EUT):
EUT Name:                       Wireless Charger Mouse Pad
Model No.:                      17831
P.O. / Ref. No.:                LBD80531
Country of Origin:              China
Country of Destination:         USA
FCC ID:                         2ACO3-17831
Standard(s) :                   47 CFR Part 18
Date of Receipt:                2018-12-06
Date of Test:                   2018-12-10 to 2018-12-21
Date of Issue:                  2018-12-26
Test Result:                    Pass*
* In the configuration tested, the EUT complied with the standards specified above.




             Keny Xu
       EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                           Report No.: SZEM181200018901
                                                           Page:       2 of 17



                                        Revision Record
     Version       Chapter               Date                 Modifier       Remark

     01                              2018-12-26                              Original




Authorized for issue by:




                             Bill Chen /Project Engineer




                             Eric Fu /Reviewer


                          SGS-CSTC Standards Technical Services Co., Ltd.
                          Shenzhen Branch
                                                     Report No.: SZEM181200018901
                                                     Page:       3 of 17



2   Test Summary
    Radio Spectrum Matter Part
            Item            Standard      Method              Requirement     Result
        Conducted
                         47 CFR Part 18   FCC MP-5            Part 18.307      Pass
        disturbance
     Radiated emission   47 CFR Part 18   FCC MP-5            Part 18.305      Pass


                                                             SGS—CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch

                                                                                                                          Report No.: SZEM181200018901
                                                                                                                          Page:                    4 of 17



3              Contents
                                                                                                                                                                                         Page
            COVER PAGE ...... ... .cc ce en eenenerererreverererereererereererereeererereeereeeeereereeeeereeeneereeeneeneeveeneeneene en nenne en nennnvvvenenennnn 1


2           TEST SUMMARY ....... ... . e0 0000000006 06090rererereererereerererereererere e reeere e reeeeeaereereeneeeneene en eeeenenne en nennnevvenennnnvvenene 3


3           CONTENTS.

4           GENERAL INFORMATION ......... o0 eeeremreereereeermereeermereeermereeermerereeneneereeenmeereeenmeereennnenrenrnne 5
      4.1             DETAILS OF E—ULT ; .. 220 en en en en m en eere en en e en en en en en en en en en en en en en eneve en en evee en enevee en enevneeenenenee n 5
      4.2             DESCRIPTION OF SUPPORT UNITS . ... ... 220. en en e en en m en en n en en en en evre en en en en en nevevee en en en en enevevennenenen n 5
      4.3             MEASUREMENT UNCERTAINTY .                                                                                                                       .5
      4.4             TEST LOCATION.............cl....                                                                                                                .6
      4.5             TEST FAGILITY . c2e0 000 e en en en n en en n en en en en en n en en en en en en enevee en enevee en eneveveereveenevee en eneveenenenevennnnenene 6
      4.6             DEVIATION FROM STANDARDS..........cccccceceeeee.                                                                                                .6
      4.7             ABNORMALITIES FROM STANDARD CONDITIONS                                                                                                          .6
5           EQUIPMENT LIST ...... .ce eeeremreermmereeermereeermereeermereeermereeermerereenereeenmeeneereeenmeereennmeereeennnenre en 7

6           RADIO SPECTRUM MATTER TEST RESULTS .......... 00000 eeermereeenmeereeenmeeneereennmnmeenennmennennnnenne en 8
      6.1             CONDUCTED DISTURBANCE                                                                                                                                                  8
            6.1.1       E.U.T. Operation.......                                                                                                                                            ...8
            6.1.2         TBSt SQUUDP DI@GTAM ............cccccvceemememereeremereenerenereenerenereeneneneneeneneneneeeeenenneneeneneneneeneneneneeneneneneme n 8
            6.1.3       Measurement Procedure and Data.                                                                                                                                    ...9
      6.2             RADIATED EMISSION ... cesmm                                                                                                                                          A2
            6.2.1         E.U.T. ODBTBIION ........cccvceememereemererereenerenemeenerenereenereneneeneneneneeneneneneneenenenneneeneneneneeneneneneenenenen en 13
            6.2.2         Test Setup Diagram ...                                                                                                               13
            6.2.3         Measurement Procedure and Data.                                                                                                                                  .14
7           PHOTOGRAPHS........ ... omm eeemmmeermmereemereeemereeemereeermereeermerereeermeeeenmeeneereeenmeereennneereennnenrnnee 17
      7.1             ces S e 17
      7.2             EUT CONSTRUCTIONAL DETAILS (EUT PHOTOS)......... cesmm en en en en n m en n eneerenenenene en en en 17




                                             Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                             overieaf, available on request or accessible at hitp:/Jwwn.ags.com/en/Terms—and—Gonditonsaspx and. for electronic format documents,
                                             subject to Terms and Conditions for Electronic Documents at hitp:Jwwn.sgs.comen/Te                   —Conditions/Terms—s—Document.aspx:
                                             Attention is drawn to the limitation of iabilit, indmmnification                 y eavee defred herom. any ofoor of ts document is
                                             advised that information contained hereon reflects the Company‘s findings at the time of ts intervention only and within the !imits of
                                             Clients instructions, if any. The Company‘s sole responsibiity is to its Client and this document does not exonerate parties to a
                                             transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                             except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                                             appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                                             results shoun in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                                             Aftention: To check the authenticity of testing /inspection report & certificate, please contact us at mephane (s6—758) s307 1443,
                                             or email: CN.Doccheck@sgs.com
                                                 No.t WortshopN10dSecton,Scence & Technology PartShenzhen, China 518057   t (86—758) 26012053 1 (%6—750) 26710504   wimsgsgroup.com.en
    Shonwhen Bontwe       Bre C   aboslor:       #B —2H— ARRIHENV—108—S1 B                               #B4: steosy      t (86—755)26012053 f (86—755) 26710504    suschina@sys.com
                                             t
                                                                                                                                             Member of the SGS Group (SGS SA)


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                              Report No.: SZEM181200018901
                                                              Page:       5 of 17


4   General Information
4.1 Details of E.U.T.
    Power supply:            Input: DC5V/2A 9V/1.67A
                             Output: DC 5V/1A 9V/1A
    Cable:                   USB cable:95cm unshielded
    Antenna Type:            Loop Antenna
    Modulation Type:         Load Modulation
    Operation Frequency:     111.54kHz to 180.77kHz


4.2 Description of Support Units

    Description                  Manufacturer              Model No.                   Serial No.
    Adapter                          Apple               A1357 W010A051          REF. No.SEA0500
     Mobile phone                 SAMSUNG                  SM-G9500                R28J9140LPB


4.3 Measurement Uncertainty

      No.                           Item                          Measurement Uncertainty
       1                      Radio Frequency                              ± 7.25 x 10-8
       2                         Duty cycle                                  ± 0.37%
       3                    Occupied Bandwidth                                ± 3%
       4                    RF conducted power                               ± 0.75dB
       5                      RF power density                               ± 2.84dB
       6               Conducted Spurious emissions                          ± 0.75dB
                                                                       ± 4.5dB (below 1GHz)
       7                     RF Radiated power
                                                                       ± 4.8dB (above 1GHz)
                                                                       ± 4.5dB (Below 1GHz)
       8               Radiated Spurious emission test
                                                                       ± 4.8dB (Above 1GHz)
       9                      Temperature test                                ± 1°C
       10                       Humidity test                                 ± 3%
       11                     Supply voltages                                ± 1.5%
       12                           Time                                      ± 3%


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                     Report No.: SZEM181200018901
                                                                     Page:       6 of 17


4.4 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
    No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
    518057.
    Tel: +86 755 2601 2053          Fax: +86 755 2671 0594
    No tests were sub-contracted.

4.5 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.
4.6 Deviation from Standards
    None
4.7 Abnormalities from Standard Conditions
    None


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                 Report No.: SZEM181200018901
                                                                 Page:       7 of 17



5      Equipment List
Conducted disturbance
        Equipment           Manufacturer         Model No      Inventory No    Cal Date    Cal Due Date
      Shielding Room      ChangZhou ZhongYu       GB-88        SEM001-06      2017-05-10    2020-05-09
Measurement Software            AUDIX          e3 V5.4.1221d       N/A           N/A           N/A
       Coaxial Cable             SGS               N/A         SEM024-01      2018-07-12    2019-07-11
           LISN            Rohde & Schwarz       ENV216        SEM007-01      2018-09-25    2019-09-24
           LISN            ETS-LINDGREN           3816/2       SEM007-02      2018-04-02    2019-04-01
     EMI Test Receiver     Rohde & Schwarz         ESCI        SEM004-02      2018-04-02    2019-04-01

Radiated emission
        Equipment           Manufacturer         Model No      Inventory No    Cal Date    Cal Due Date
    10m Semi-Anechoic
                               SAEMC            FSAC1018       SEM001-03      2018-03-31    2021-03-30
        Chamber
                                               e3 V8.2014-6-
Measurement Software            AUDIX                              N/A           N/A           N/A
                                                    27
       Coaxial Cable             SGS               N/A         SEM029-01      2018-07-12    2019-07-11
     EMI Test Receiver
                           Rohde & Schwarz         ESR         SEM004-03      2018-04-02    2019-04-01
       (9kHz-7GHz)
     Trilog-Broadband
          Antenna            Schwarzbeck        VULB9168       SEM003-18      2016-06-29    2019-06-28
      (30MHz-1GHz)
                          Sonoma Instrument
       Pre-amplifier                               310N        SEM005-04      2018-04-13    2019-04-12
                                Co
    Active Loop Antenna      ETS-Lindgren          6502        SEM003-08      2017-08-22    2020-08-21

General used equipment
        Equipment           Manufacturer         Model No      Inventory No    Cal Date    Cal Due Date
                               Shanghai
Humidity/ Temperature
                             Meteorological       ZJ1-2B       SEM002-03      2018-09-27    2019-09-26
      Indicator
                            Industry Factory
                               Shanghai
Humidity/ Temperature
                             Meteorological       ZJ1-2B       SEM002-04      2018-09-27    2019-09-26
      Indicator
                            Industry Factory
Humidity/ Temperature
                                Mingle             N/A         SEM002-08      2018-09-27    2019-09-26
      Indicator
                              Changchun
        Barometer            Meteorological       DYM3         SEM002-01      2018-04-08    2019-04-07
                            Industry Factory


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                               Report No.: SZEM181200018901
                                                               Page:       8 of 17



6    Radio Spectrum Matter Test Results
6.1 Conducted disturbance
     Test Requirement        Part 18.307
     Test Method:            FCC MP-5
     Limit:




6.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      22.6 °C         Humidity: 49.6 % RH       Atmospheric Pressure: 1020 mbar
      Test mode         a: Normal Working mode,keep charging with mobile phone in low battery
                        b: Normal Working mode,keep charging with mobile phone in intermediate battery
                        c: Normal Working mode,keep charging with mobile phone in full battery
                        d: Normal Working mode,keep EUT working with full load.
                        e: Normal Working mode,keep EUT working with half load
                        f: Normal Working mode,keep EUT working with no load
      Test Worse case a: Normal Working mode,keep charging with mobile phone in low battery
6.1.2 Test Setup Diagram


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                 Report No.: SZEM181200018901
                                                                 Page:       9 of 17



6.1.3 Measurement Procedure and Data
      Test Procedure:      1) The mains terminal disturbance voltage test was conducted in a shielded
                              room.
                              2) The EUT was connected to AC power source through a LISN 1 (Line
                                 Impedance Stabilization Network) which provides a 50Ω/50µH + 5Ω
                                 linear
                                 impedance. The power cables of all other units of the EUT were
                                 connected to a second LISN 2, which was bonded to the ground
                                 reference plane in the same way as the LISN 1 for the unit being
                                 measured. A multiple socket outlet strip was used to connect multiple
                                 power cables to a single LISN provided the rating of the LISN was not
                                 exceeded.
                              3) The tabletop EUT was placed upon a non-metallic table 0.8m above the
                                 ground reference plane. And for floor-standing arrangement, the EUT
                                 was
                                 placed on the horizontal ground reference plane,
                              4) The test was performed with a vertical ground reference plane. The rear
                                 of the EUT shall be 0.4 m from the vertical ground reference plane. The
                                 vertical ground reference plane was bonded to the horizontal ground
                                 reference plane. The LISN 1 was placed 0.8 m from the boundary of the
                                 unit under test and bonded to a ground reference plane for LISNs
                                 mounted on top of the ground reference plane. This distance was
                                 between the closest points of the LISN 1 and the EUT. All other units of
                                 the EUT and associated equipment was at least 0.8 m from the LISN 2.
                              5) In order to find the maximum emission, the relative positions of
                                 equipment and all of the interface cables must be changed on
                                 conducted measurement.


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                               Report No.: SZEM181200018901
                                               Page:       10 of 17

Mode:a; Line:Live Line


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                  Report No.: SZEM181200018901
                                                  Page:       11 of 17

Mode:a; Line:Neutral Line


                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                   Shenzhen Branch
                                                                    Report No.: SZEM181200018901
                                                                    Page:       12 of 17



6.2 Radiated emission
         Test Requirement      Part 18.305
         Test Method:          FCC MP-5
         Measurement Distance: 3m
         Limit:




1Fieldstrength may not exceed 10 µV/m at 1600 meters. Consumer equipment operating below 1000 MHz is
not permitted the increase in field strength otherwise permitted here for power over 500 watts.
2Reduced     to the greatest extent possible.
3Field  strength may not exceed 10 µV/m at 1600 meters. Consumer equipment is not permitted the increase
in field strength otherwise permitted here for over 500 watts.
4Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field strength limits
for miscellaneous ISM equipment.


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                               Report No.: SZEM181200018901
                                                               Page:       13 of 17




6.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C           Humidity: 51 % RH         Atmospheric Pressure: 1020 mbar
      Test mode         a: Normal Working mode,keep charging with mobile phone in low battery
                        b: Normal Working mode,keep charging with mobile phone in intermediate battery
                        c: Normal Working mode,keep charging with mobile phone in full battery
                        d: Normal Working mode,keep EUT working with full load.
                        e: Normal Working mode,keep EUT working with half load
                        f: Normal Working mode,keep EUT working with no load
      Test Worse case a: Normal Working mode,keep charging with mobile phone in low battery
6.2.2 Test Setup Diagram


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                             Report No.: SZEM181200018901
                                                             Page:       14 of 17



6.2.3 Measurement Procedure and Data
     Test Procedure:   a. The EUT was placed on the top of a rotating table 0.8 meters above the
                          ground at a 3 meter semi-anechoic chamber(30MHz-1000MHz) and 3 meter
                          semi-anechoic chamber(9kHz-30MHz). The table was rotated 360 degrees
                          to determine the position of the highest radiation.
                       b. The EUT was set 10 meters(30MHz-1000MHz) and 10 meter (9kHz-30MHz)
                          away from the interference-receiving antenna, which was mounted on the
                          top of a variable-height antenna tower.
                       c.   Above 30MHz: The Analyzer/Receiver scanned from 30MHz to
                            1000MHz.The antenna height is varied from one meter to four meters above
                            the ground to determine the maximum value of the field strength. Both
                            horizontal and vertical polarizations of the antenna are set to make the
                            measurement.
                       d. Below 30MHz: The Analyzer/Receiver scanned from 9kHz to 30MHz.The
                          antenna height is 2 meters above the ground to determine the maximum
                          value of the field strength.
                       e. For each suspected emission, the EUT was arranged to its worst case and
                          then the antenna was tuned to heights from 1 meter to 4 meters (for the test
                          frequency of below 30MHz, the antenna was tuned to heights 2 meter) and
                          the rotatable table was turned from 0 degrees to 360 degrees to find the
                          maximum reading.
                       f.   The test-receiver system was set to Peak Detect Function and Specified
                            Bandwidth with Maximum Hold Mode.
                       g. If the emission level of the EUT in peak mode was 10dB lower than the limit
                          specified, then testing could be stopped and the peak values of the EUT
                          would be reported. Otherwise the emissions that did not have 10dB margin
                          would be re-tested one by one using peak, quasi-peak or average method
                          as specified and then reported in a data sheet.
                       h. Repeat above procedures until all frequencies measured was complete.
                       i.   Measurement Requirement:
                       1)This product belongs to non-ISM equipment, the field strength limit is 15uV/m
                       at 300 meter distance.
                       2)Limit: 20log(15uV/m) +20log (300/3) =23.52+40=63.52dBuV/m at 3 meters
                       distance


              SGS-CSTC Standards Technical Services Co., Ltd.
              Shenzhen Branch
                                    Report No.: SZEM181200018901
                                    Page:       15 of 17

Mode a:
9kHz-150kHz


               SGS-CSTC Standards Technical Services Co., Ltd.
               Shenzhen Branch
                                     Report No.: SZEM181200018901
                                     Page:       16 of 17

Mode a:
150kHz-30MHz


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                   Report No.: SZEM181200018901
                                                                   Page:       17 of 17



7   Photographs
7.1 Test Setup
    Please refer to setup photos.

7.2 EUT Constructional Details (EUT Photos)
    Please refer to external and internal photos for details.


                                           - End of the Report -



Document Created: 2018-12-27 07:10:52
Document Modified: 2018-12-27 07:10:52

© 2024 FCC.report