RF Exposure

FCC ID: 2ACN7PE805A

RF Exposure Info

Download: PDF
FCCID_3476458

RF Exposure Requirements

Product Description: Activity Tracker
Model No.: PE805A
FCC ID: 2ACN7PE805A

According to the KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz
to 6 GHz at test separation distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where
- f(GHz) is the RF channel transmit frequency in GHz
- Power and distance are rounded to the nearest mW and mm before calculation
- The result is rounded to one decimal place for comparison


Bluetooth
Tx frequency range: 2402~2480MHz
Device category: Portable device (Distance: 5mm)
Maximum Conducted Output Power: -3.282dBm
Maximum Conducted Output Power: 0.46mW
Limit: 10mW
Source-based time-averaged Conducted output power is 0.46mW < 10mW

So the transmitter complies with the RF exposure requirements and the SAR is not required.



Document Created: 2017-07-19 11:10:07
Document Modified: 2017-07-19 11:10:07

© 2024 FCC.report