RF Exposure

FCC ID: 2ACN7-HRM812

RF Exposure Info

Download: PDF
FCCID_2978730

RF Exposure Requirements

Product Description: Heart Rate Monitor
Model No.: HRM812
FCC ID: 2ACN7-HRM812
IC: 21215-HRM812

Bluetooth:

FCCID:
According to the KDB 447498 D01 v06, the following RF exposure evaluation shall to
demonstrate RF exposure compliance.

Tx frequency range: 2402~2480MHz
Device category: Portable device (Distance: 5mm)
Maximum Conducted Output Power: -3.445dBm
Maximum Conducted Output Power: 0.452mW
Limit: 10mW
Source-based time-averaged Conducted output power is 0.452mW < 10mW

So the transmitter complies with the RF exposure requirements and the SAR is not required.

IC:
According to RSS-102 issue 5, SAR evaluation is required if the separation distance between the
user and the device is less than or equal to 20 cm, except when the device operates:

Tx frequency range: 2402~2480MHz
Device category: Portable device (Distance: 5mm)
Maximum Conducted Output Power: -3.445dBm
Maximum Output Power: 0.452mW
Limit: 4mW
Source-based time-averaged output power is 0.452mW < 4 mW

So the transmitter complies with the RF exposure requirements and the SAR is not required.



Document Created: 2016-05-03 11:26:35
Document Modified: 2016-05-03 11:26:35

© 2024 FCC.report