RF-Exposure-MPE

FCC ID: 2ACCU-E45BT001

RF Exposure Info

Download: PDF
FCCID_4490310

                              RF Exposure evaluation
Exposure category: General population/uncontrolled environment
EUT Type: Production Unit
Device Type: Mobile Device
Refer Standard: KDB 447498 D01 General RF Exposure Guidance v06
                FCC Part 2 §2.1091

FCC ID: 2ACCU-E45BT001

1. Reference
According to §1.1307(b)(1), systems operating under the provisions of this section shall be
operated in a manner that ensures that the public is not exposed to radio frequency energy
level in excess of the Commission’s guidelines.
According to §1.1310 and §2.1091 RF exposure is calculated.
KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment
Authorization Policies

2. Limit
Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure
  Frequency       Electric Field    Magnetic Field     Power Density         Averaging Time
 Range(MHz)       Strength(V/m)      Strength(A/m)        (mW/cm²)              (minute)
                      Limits for Occupational/Controlled Exposure
   0.3 – 3.0           614                1.63              (100) *                  6
   3.0 – 30           1842/f             4.89/f            (900/f2)*                 6
   30 – 300            61.4              0.163                1.0                    6
  300 – 1500             /                  /                f/300                   6
1500 – 100,000           /                  /                  5                     6

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure
  Frequency       Electric Field    Magnetic Field     Power Density         Averaging Time
 Range(MHz)       Strength(V/m)      Strength(A/m)        (mW/cm²)              (minute)
                      Limits for Occupational/Controlled Exposure
   0.3 – 3.0           614                1.63              (100) *                 30
   3.0 – 30           824/f              2.19/f            (180/f2)*                30
   30 – 300            27.5              0.073                0.2                   30
  300 – 1500             /                  /               f/1500                  30
1500 – 100,000           /                  /                 1.0                   30

F=frequency in MHz
*=Plane-wave equivalent power density


3. MPE Calculation Method
Predication of MPE limit at a given distance
Equation from page 18 of OET Bulletin 65, Edition 97-01

S=PG/4πR²
Where: S=power density
        P=power input to antenna
        G=power gain of the antenna in the direction of interest relative to an isotropic radiator
        R=distance to the center of radiation of the antenna

4. Result
As declared by the Applicant, the EUT is a wireless device used in a fix application, at least
20 cm from any body part of the user or nearby persons; from the maximum EUT RF output
power, the minimum separation distance, r =20cm, as well as the gain of the used antenna is 1
dBi, the RF power density can be obtained.



                                                 EDR
                        Target     Max tune up      Output                  Power
            Output                                                Ant                   Limit
Freq.                  power W/       power        power to               Density at
            Power                                                Gain                   (mW/c        Result
(MHz)                  tolerance     tolerance      antenna                R=20cm
             (dBm)                                               (dBi)                   m2)
                        (dBm)         (dBm)            (mW)               (mW/cm2)
                                                 GFSK
2402        -0.745      0±1.0           1              1.259       3       0.00050         1         Pass

2440        -1.256      -1±1.0          0              1.000       3       0.00040         1         Pass

2480        -1.923      -1±1.0          0              1.000       3       0.00040         1         Pass

                                                 π/4DQPSK
2402        -1.231      -1±1.0          0              1.000       3       0.00040         1         Pass

2440        -1.068      -1±1.0          0              1.000       3       0.00040         1         Pass

2480        -1.789      -1±1.0          0              1.000       3       0.00040         1         Pass


Note: The estimation distance is 20cm


5. Conclusion
        The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled
        RF Exposure of mobile device.



Document Created: 2019-10-31 01:25:16
Document Modified: 2019-10-31 01:25:16

© 2025 FCC.report