Test report DCD

FCC ID: 2AC9N-144619

Test Report

Download: PDF
FCCID_4195420

                                                                              Shenzhen CTL Testing Technology Co., Ltd.
                                                                           Tel: +86-755-89486194 E-mail: ctl@ctl-lab.com


                                        TEST REPORT
                                           FCC PART 15 SUBPART C

Report Reference No.:                           CTL1901176121-WF

           Compiled by:                                        Happy Guo
( position+printed name+signature)                        (File administrators)

             Tested by:                                       Nice Nong
( position+printed name+signature)                          (Test Engineer)

           Approved by:                                         Ivan Xie
( position+printed name+signature)                             (Manager)


Product Name ............................ : wireless charging stand
Model/Type reference ................ : 144619-00
List Model(s) ............................... : 144619-01, 144619-02
PO No. ....................................... : 393465
Trade Mark .................................. : TYPO
FCC ID ....................................... : 2AC9N-144619
Applicant’s name ....................... : Cotton On USA Inc
Address of applicant ................. : 16511, Trojan Way, La Miranda, California 90638, United States

Test Firm ..................................... : Shenzhen CTL Testing Technology Co., Ltd.

                                                Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road,
Address of Test Firm ................. :
                                                Nanshan District, Shenzhen, China 518055
Test specification ....................... :
Standard ...................................... : FCC Rules Part 15.207,15.209, 15.215(c)
                                                  ANSI C63.10-2013
TRF Originator ............................. : Shenzhen CTL Testing Technology Co., Ltd.
Master TRF .................................. : Dated 2011-01
Date of Receipt ........................... : Jan. 18, 2019
Date of Test Date ........................ : Jan. 19, 2019–Jan. 28, 2019
Data of Issue............................... : Jan. 29, 2019
Result.......................................... : Pass
Shenzhen CTL Testing Technology Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.


V1.0                                         Page 2 of 19                     Report No.: CTL1901176121-WF



                                     TEST REPORT
                                                                                     Jan. 29, 2019
       Test Report No. :            CTL1901176121-WF
                                                                                     Date of issue


       Equipment under Test          :       wireless charging stand


       Model /Type                   :       144619-00


       Listed Models                 :       144619-01, 144619-02


       Applicant                     :       Cotton On USA Inc


       Address                       :       16511, Trojan Way, La Miranda, California 90638,
                                             United States


       Manufacturer                  :       Cotton On USA Inc


       Address                       :       16511, Trojan Way, La Miranda, California 90638,
                                             United States



                       Test result                                               Pass *
  *In the configuration tested, the EUT complied with the standards specified page 5.
   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test laboratory.


V1.0                                  Page 3 of 19            Report No.: CTL1901176121-WF


                                  ** Modified History **
  Revisions             Description          Issued Data      Report No.         Remark
 Version 1.0   Initial Test Report Release    2019-01-29   CTL1901176121-WF      Tracy Qi


V1.0                                                                    Page 4 of 19                                        Report No.: CTL1901176121-WF



                                                                       Table of Contents                                                                                      Page
1.     SUMMARY ............................................................................................................................................................... 5
     1.1.     TEST STANDARDS ..................................................................................................................................................... 5
     1.2.     TEST DESCRIPTION........................................................................................................................................................ 5
     1.3.     TEST FACILITY .............................................................................................................................................................. 6
     1.4.     STATEMENT OF THE MEASUREMENT UNCERTAINTY............................................................................................................... 6
2.     GENERAL INFORMATION .......................................................................................................................................... 7
     2.1.     ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 7
     2.2.     GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7
     2.3.     SPECIAL ACCESSORIES ................................................................................................................................................... 7
     2.4.     EQUIPMENTS USED DURING THE TEST .............................................................................................................................. 7
     2.5.     RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................ 8
     2.6.     MODIFICATIONS ........................................................................................................................................................... 8
3.     TEST CONDITIONS AND RESULTS .............................................................................................................................. 9
     3.1.     CONDUCTED EMISSIONS TEST ......................................................................................................................................... 9
     3.2.     RADIATED EMISSIONS.................................................................................................................................................. 12
     3.3.     20DB BANDWIDTH..................................................................................................................................................... 15
4.     TEST SETUP PHOTOS OF THE EUT ........................................................................................................................... 16
5.     PHOTOS OF THE EUT .............................................................................................................................................. 17


V1.0                                   Page 5 of 19               Report No.: CTL1901176121-WF


1. SUMMARY
1.1. TEST STANDARDS
The tests were performed according to following standards:
FCC Rules Part 15.207,15.209, 15.215(c)
ANSI C63.10: 2013: American National Standard for Testing Unlicensed Wireless Devices

1.2. Test Description
              Test Item                          Test Standards               Test Result
  Electric Field Radiated Emissions      FCC Part 15 C (Section15.209)           PASS
  20dB Bandwidth/99% Bandwidth         FCC Part 15 C (Section15.215(c))          PASS
       Conducted Emissions               FCC Part 15 C (Section15.207)           PASS


V1.0                                       Page 6 of 19                 Report No.: CTL1901176121-WF



1.3. Test Facility
1.3.1 Address of the test laboratory
Shenzhen CTL Testing Technology Co., Ltd.
Floor 1-A, Baisha Technology Park, No. 3011, Shahexi Road, Nanshan, Shenzhen 518055 China

The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR
16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

1.3.2   Laboratory accreditation
The test facility is recognized, certified, or accredited by the following organizations:
IC Registration No.: 9618B
The 3m alternate test site of Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been
registered by Certification and Engineer Bureau of Industry Canada for the performance of with
Registration No.: 9618B on November 13, 2013.
FCC-Registration No.: 399832
Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been registered and fully described
in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the
FCC is maintained in our files. Registration 399832, December 08, 2017.

1.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that
there may be errors within the calibration limits of the equipment and facilities. The measurement
uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16 - 4
“Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
Uncertainty in EMC Measurements“ and is documented in the Shenzhen CTL Testing Technology Co.,
Ltd. quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of
devices similar to that tested may result in additional deviation. The manufacturer has the sole
responsibility of continued compliance of the device.

Hereafter the best measurement capability for CTL laboratory is reported:
                                                                    Measurement
                            Test                                                          Notes
                                                                      Uncertainty
                Transmitter power conducted                            ±0.57 dB            (1)
                 Transmitter power Radiated                            ±2.20 dB            (1)
        Conducted spurious emission 9KHz-40 GHz                        ±2.20 dB            (1)
                    Occupied Bandwidth                                 ±0.01ppm            (1)
               Radiated Emission 30~1000MHz                             ±4.10dB            (1)
               Radiated Emission Above 1GHz                             ±4.32dB            (1)
             Conducted Disturbance0.15~30MHz                            ±3.20dB            (1)
  (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
      confidence level using a coverage factor of k=2.


V1.0                                          Page 7 of 19                    Report No.: CTL1901176121-WF


2. GENERAL INFORMATION
2.1. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
                    Normal Temperature:                                                25°C
                     Relative Humidity:                                             55 %
                       Air Pressure:                                               101 kPa

2.2. General Description of EUT
Product Name:                  wireless charging stand
Model/Type reference:          144619-00
Input Voltage:                 DC 5V 2A
Rated power:                   5W
Operation frequency:           110KHz~200KHz
Antenna type:                  Coil antenna
Antenna gain:             0dBi
Note: For more details, please refer to the user’s manual of the EUT.

2.3. Special Accessories
 Manufacturer            Description          Model            Serial Number                       Remark
       ASUS             Notebook PC         FL5900U                9014                 Provided by the laboratory
   Samsung                 Phone            Galaxy s7         35615607721414            Provided by the laboratory


2.4. Equipments Used during the Test
                                                                                              Calibration   Calibration
  Test Equipment            Manufacturer          Model No.               Serial No.
                                                                                              Date recent   Due Date
         LISN                   R&S                ENV216             3560.6550.12            2018/06/01    2019/05/31

         LISN                   R&S               ESH2-Z5              860014/010             2018/06/01    2019/05/31

    Power Meter                Agilent             U2531A             TW53323507              2018/06/01    2019/05/31

   Power Sensor                Agilent            U2021XA              MY5365004              2018/05/20    2019/05/19

 EMI Test Receiver              R&S                   ESCI                 103710             2018/06/01    2019/05/31
 Spectrum Analyzer             Agilent             E4407B             MY41440676              2018/05/20    2019/05/19
 Spectrum Analyzer             Agilent                N9020           US46220290              2018/01/16    2019/01/15

       Controller          EM Electronics     Controller EM 1000             N/A              2018/05/20    2019/05/19

Active Loop Antenna             Daze              ZN30900A                   N/A              2018/05/18    2019/05/17

   Bilog Antenna            Schwarzbeck          VULB 9168                 00824              2018/10/25    2019/10/24

                           Sunol Sciences
   Horn Antenna                                   DRH-118                 A062013             2018/05/18    2019/05/17
                               Corp.
   Horn Antenna           SCHWARZBACK            BBHA 9170            BBHA9170184             2018/05/18    2019/05/17

       Amplifier               Agilent                8349B           3008A02306              2018/05/18    2019/05/17

       Amplifier               Agilent                8447D           2944A10176              2018/05/18    2019/05/17

Temperature/Humidity
                              Gangxing            CTH-608                    02               2018/05/19    2019/05/18
      Meter


V1.0                                     Page 8 of 19               Report No.: CTL1901176121-WF


  High-Pass Filter        K&L           9SH10-2700/X12750-O/O      N/A         2018/05/19   2019/05/18

  High-Pass Filter        K&L           41H10-1375/U12750-O/O      N/A         2018/05/19   2019/05/18

                                              SUCOFLEX                         2018/06/01   2019/05/31
  Coaxial Cables     HUBER+SUHNER                                  10m
                                             104PEA-10M
  Coaxial Cables     HUBER+SUHNER       SUCOFLEX 104PEA-3M         3m          2018/06/01   2019/05/31

  Coaxial Cables     HUBER+SUHNER       SUCOFLEX 104PEA-3M         3m          2018/06/01   2019/05/31

       RF Cable          Megalon              RF-A303              N/A         2018/06/01   2019/05/31

 EMI Test Software        R&S                  ES-K1              V1.7.1       2018/06/01   2019/05/31

 EMI Test Software       AUDIX                   E3                V6.0        2018/06/01   2019/05/31
The calibration interval was one year

2.5. Related Submittal(s) / Grant (s)
This submittal(s) (test report) is intended to comply with FCC Part 15, Subpart C Rules.

2.6. Modifications
No modifications were implemented to meet testing criteria.


V1.0                                            Page 9 of 19                    Report No.: CTL1901176121-WF


3. TEST CONDITIONS AND RESULTS
3.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.207

                                                                            Limit (dBuV)
          Frequency range (MHz)
                                                           Quasi-peak                        Average

                   0.15-0.5                                  66 to 56*                       56 to 46*
                     0.5-5                                      56                              46

                     5-30                                       60                              50

* Decreases with the logarithm of the frequency.


TEST CONFIGURATION




TEST PROCEDURE

1.     The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
       manual. The EUT is a tabletop system; a wooden table with a height of 0.8 meters is used and is placed on
       the ground plane as per ANSI C63.10:2013.
2.     Support equipment, if needed, was placed as per ANSI C63.10:2013.
3.     All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10:2013.
4.     The adapter received AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which
       supplied power source and was grounded to the ground plane.
5.     All support equipments received AC power from a second LISN, if any.
6.     The EUT test program was started. Emissions were measured on each current carrying line of the EUT
       using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
       monitoring points:    Line 1 (Hot Side) and Line 2 (Neutral Side).   Two scans were taken:   one with Line 1
       connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
       connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
7.     Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.
8.     During the above scans, the emissions were maximized by cable manipulation.


SCAN TABLE:          "Voltage        (9K—30M)FIN"
  Short Description:                            150K—30M voltage

   Level {aBV)
 zo




                                            i
 10                                        4i                         i
                                            i                         i
      150k       300% 400k     60ok: 800k 1M               2m        3     4n 5M 6M    B tom   20M   30M
                                                       Frequency [Hz]
xxx



MEASUREMENT RESULT:                "CTL190122461_fin"

2019—1—22     04:26
   Frequency        Level                   Limit        Margin      Detector     Line    PE
          MHz        dBuy              dB    dBpy            as
                      25. 50                      so        34.0     o            11
                      24.70                       56        31.3     oP           L1
                      27.20                       56        28.8      op          L1
                      20 .00                      56        36.0     P            L1
                      12.30                       60        a7.7      oP          L1
                      10.50                       60        49.5      oP          L1


MEASUREMENT RESULT:                "CTL190122461_fin2"

2019—1—22     04:26
   Frequency        Level              sd   Limit        Margin      Detector     Line    PB
          MHz        dBuy              dB    dBpy            as
                      22. 90                      s1          a      AV           L1
                      19.20                       46          6      AV           L1
                      19. 30            3         46        26.7     AV           L1
                      15.50            14         46        30.5      av          L1
                       9.20            L          5o        a0.8      av          L1
                      10.80            .6         5o        30.2      av          L1


SCAN TABLE:         "Voltage             (9K—30M)FIN"
  Shozt Description:                                 150K—30M voltage

  Lovel dBuV]




                                                \
                                               1i
                                   i            i                          i
   150k         300k 400k        600k    800k 1M                2M        3     4n 5M 6M   BM 10M   20M   30M
                                                            Frequency [Hz]




MEASUREMENT RESULT:                     "CTL190122460_fin"

2019—1     04      :232
   Frequency                                        Limit     Margin                   Line    PE
         Niz                                         dBpy
                      27.00                            61        34.4      oP          N
                      24.10                            56        31.9      op          N
                      25. 30                           56        30.7      oP          N
                      20. 40                           56        35.6      oP          N
                      13.70                            60        46.3     oP           N
                      10.10                            60        a9.9     op           N



MEASUREMENT RESULT:                     "CTL190122460_fin2"
2019—1—22    04:23
   Frequency       Level           Transd           Limit    Margin       Detector     Line    PE
            hiz           dBuy            dB         dBpy           as

    0.                23.00             11.2           51        28.2      AV          N
    0.                22.40                            46           6.    AV           N
    1.                19. 30              .            46           7.    AV           N
    2                 15. 60            11.4           46           4      AV          N
    5                  7. 60            11.3           50           4      AV          N
   25.                10.20             11.6           50        39.8     AV           N


V1.0                                     Page 12 of 19                 Report No.: CTL1901176121-WF



3.2. Radiated Emissions
Limit

For intentional device, according to § 15.209(a), the general requirement of field strength of radiated
emission out of authorized band shall not exceed the following table at a 3 meters measurement
distance.
In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also
comply with the radiated emission limits specified in §15.209(a)
                                      Radiated emission limits
  Frequency (MHz)       Distance (Meters)           Radiated (dBμV/m)                  Radiated (μV/m)
     0.009-0.49                 3            20log(2400/F(KHz))+40log(300/3)             2400/F(KHz)
     0.49-1.705                 3            20log(24000/F(KHz))+ 40log(30/3)           24000/F(KHz)
      1.705-30                  3                 20log(30)+ 40log(30/3)                      30
        30-88                   3                           40.0                             100
       88-216                   3                           43.5                             150
      216-960                   3                           46.0                             200
     Above 960                  3                           54.0                             500

TEST CONFIGURATION
                 1. Radiated Emission Test Set-Up, Frequency Below 30MHz




                       2. Radiated Emission Test Set-Up, Frequency below 1000MHz


V1.0                                     Page 13 of 19                Report No.: CTL1901176121-WF


Test Procedure

1.     Below 1GHz measurement the EUT is placed on a turntable which is 0.8m above ground plane,
       and above 1GHz measurement EUT was placed on a low permittivity and low loss tangent turn
       table which is 1.5m above ground plane.
2.     Maximum procedure was performed by raising the receiving antenna from 1m to 4m and rotating
       the turn table from 0℃ to 360℃ to acquire the highest emissions from EUT
3.     And also, each emission was to be maximized by changing the polarization of receiving antenna
       both horizontal and vertical.
4.     Repeat above procedures until all frequency measurements have been completed.
5.     Radiated emission test frequency band from 9KHz to 1000MHz.
6.     The distance between test antenna and EUT as following table states:
             Test Frequency range      Test Antenna Type            Test Distance
             9KHz-30MHz                Active Loop Antenna          3
             30MHz-1GHz                Bilog Antenna                3
7.     Setting test receiver/spectrum as following table states:
               Test Frequency              Test Receiver/Spectrum Setting         Detector
                     range
                9KHz-150KHz         RBW=200Hz/VBW=3KHz,Sweep time=Auto              QP
               150KHz-30MHz         RBW=9KHz/VBW=100KHz,Sweep time=Auto             QP
                                       RBW=120KHz/VBW=1000KHz,Sweep
                30MHz-1GHz                                                          QP
                                                      time=Auto


Test Results

WORST-CASE RADIATED EMISSION BELOW 30 MHz
                                       Antenna     Cable    Emission                           Detector
 Frequency       Reading      Polar                                  Limits at 3m    Margin
                                        Factor     Loss       Levels                            Mode
      (MHz)      (dBμV/m)     Loop      (dB/m)     (dB)     (dBμV/m)  (dBμV/m)         (dB)
     0.125(F)      54.91      Loop       23.64      0.01      78.56       105.67      27.11       PK
     0.125(F)      45.79      Loop       23.64      0.01      69.44       85.67       16.23       AV
       0.110       37.82      Loop       23.55      0.01      61.38       106.78      45.40       PK
       0.110       31.11      Loop       23.55      0.01      54.67       86.78       32.11       AV
       0.495       25.46      Loop       25.07      -0.17     50.36       73.71       23.35       QP
       1.654       16.82      Loop       27.12      -0.25     43.69       63.23       19.54       QP
       2.418       17.02      Loop       23.91      -0.24     40.69       69.54       28.85       QP
        --          --         --         --         --         --          --                    --
Remark:
1. Data of measurement within this frequency range shown “-- in the table above means the reading
   of emissions are attenuated more than 20dB below the permissible limits and not recorded.
2. The test limit distance is 3m limit.
3. PK means Peak Value, QP means Quasi Peak Value, AV means Average Value.
4. F means Fundamental Frequency.
5. Emission level (dBuV/m) =Reading + Antenna Factor + Cable Loss.
6. Margin value = Limit value- Emission level.


V1.0              Page 14 of 19     Report No.: CTL1901176121-WF

 For 30MHz-1GHz
                       Horizontal




                        Vertical


V1.0                                     Page 15 of 19               Report No.: CTL1901176121-WF



3.3. 20dB Bandwidth
Limit
The 20dB bandwidth shall be less than 80% of the permitted frequency band.

Test Procedure

The transmitter output was connected to the spectrum analyzer through an attenuator. The bandwidth
of the fundamental frequency was measured by spectrum analyzer with 30 KHz RBW and 100 KHz
VBW.
The 20dB bandwidth is defined as the total spectrum the power of which is higher than peak power
minus 20dB.

Test Configuration


                    EUT                              SPECTRUM
                                                     ANALYZER

Test Results

        Frequency           20dB bandwidth                99% OBW
                                                            (KHz)                     Result
          (MHz)                 (KHz)
          0.145                  4.709                       4.026                    Pass


V1.0                    Page 16 of 19   Report No.: CTL1901176121-WF


4. Test Setup Photos of the EUT


V1.0                    Page 17 of 19           Report No.: CTL1901176121-WF


5. Photos of the EUT
                       External Photos of EUT


V1.0   Page 18 of 19   Report No.: CTL1901176121-WF


V1.0                   Page 19 of 19                Report No.: CTL1901176121-WF

                      Internal Photos of EUT




       ********************** End of Report **********************



Document Created: 2019-03-05 10:22:20
Document Modified: 2019-03-05 10:22:20

© 2024 FCC.report