Test Report

FCC ID: 2AC7ISOLER240N

Test Report

Download: PDF

                                              FCC PART 15 B
                                               TEST REPORT
                                                              For

                               Interglobe Connection Corp
                        8228 NW 30th Terrace, Doral, Florida, United States, 33122



                                        FCC ID: 2AC7ISOLER240N


            Report Type:                                         Product Type:

            Original Report                                      Mobile Phone

            Report Number:                 RDG181211006-00A

            Report Date:                   2019-01-25

                                           Jerry Zhang
            Reviewed By:
                                           EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                                           No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
            Test Laboratory:               Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be used
by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. * This
report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


 Bay Area Compliance Laboratories Corp. (Dongguan)                                                                        Report No.: RDG181211006-00A




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
  CONFIGURATION OF TEST SETUP .................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.107 - CONDUCTED EMISSIONS ................................................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................8
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................9
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ............................................................................................13
  EUT SETUP ................................................................................................................................................................13
  EMI TEST RECEIVER SETUP .......................................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................14
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................15
  TEST DATA ................................................................................................................................................................15




                                                                                                                                                            Page 2 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG181211006-00A


GENERAL INFORMATION

Product Description for Equipment Under Test (EUT)

                         EUT Name:       Mobile Phone
                        EUT Model:       SOLE R240
                            FCC ID:      2AC7ISOLER240N
                Rated Input Voltage:     DC3.7V from Li-ion Rechargeable Battery or DC5V from adapter
                       Trame Name:       SOLE
      Adapter
                              Input:     100-240V, 50/60Hz
    Information
                             Output:     DC5.0V, 500mA
       Highest Operation Frequency:      2480 MHz
                External Dimension:      128.8mm(L)* 57.6mm(W)*15 mm(H)
                     Serial Number:      181211006
                 EUT Received Date:      2018.12.11


Objective

This test report is prepared on behalf of Interglobe Connection Corp in accordance with Part 2, Subpart J, and
Part 15-Subparts A and B of the Federal Communications Commission’s rules.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 B Class B.


Related Submittal(s)/Grant(s)

FCC Part 15C DSS submissions with FCC ID: 2AC7ISOLER240N.
FCC Part 22H, 24E PCE submissions with FCC ID: 2AC7ISOLER240N.


Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Dongguan).




                                                                                                  Page 3 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG181211006-00A


Measurement Uncertainty


                Parameter                                Measurement Uncertainty
                                       30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
       Unwanted Emissions, radiated
                                          6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
                Temperature                                        ±1℃
               Humidity                                            ±5%
   AC Power Lines Conducted Emission                    3.12 dB (150 kHz to 30 MHz)



Test Facility

The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier: CN0022.




                                                                                            Page 4 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG181211006-00A


SYSTEM TEST CONFIGURATION

Description of Test Configuration

The system was configured for testing in operating and downloading mode.


EUT Exercise Software

The software “Winthrax.exe” was used during test.


Equipment Modifications

No modification was made to the EUT tested.


Local Support Equipment List and Details

        Manufacturer               Description           Model                    Serial Number
           DELL                       Laptop             PP11L                  QDS-BRCM1017
             HP                       Printer            C3941A                   JPTVOB2337
           DELL                     Keyboard              L100            CNORH656658907BL05DC
            SAST                      Modem             AEM-2100                      0293



Support Cable List and Details

                          Shielding                     Length
    Cable Description                    Ferrite Core                   From Port                 To
                            Type                         (m)
       Serial Cable          yes                No       1.2       Serial Port of Laptop      Modem
      Parallel Cable         yes                No       1.2       Parallel Port of Laptop     Printer

     Keyboard Cable          yes                No       1.8        USB Port of Laptop       Keyboard

        USB Cable            No                 No       1.04       USB Port of Laptop            EUT
      Earphone Cable         No                 No       0.86               EUT              Earphone




                                                                                                  Page 5 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG181211006-00A



Configuration of Test Setup




                                                                      Page 6 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)               Report No.: RDG181211006-00A


SUMMARY OF TEST RESULTS

         FCC Rules                        Description of Test              Results

           §15.107                        Conducted Emissions            Compliance

           §15.109                         Radiated Emissions            Compliance




                                                                                     Page 7 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG181211006-00A


FCC§15.107 - CONDUCTED EMISSIONS
EUT Setup




The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The specification used
was with the FCC Part 15 B Class B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle.

The adapter was connected to the Main LISN with 120V/60Hz AC power source.


EMI Test Receiver Setup

The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                       IF B/W
                              150 kHz – 30 MHz                       9 kHz




                                                                                                Page 8 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG181211006-00A

Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
      Manufacturer              Description          Model
                                                                    Number           Date         Due Date
           R&S              EMI Test Receiver       ESCS 30       830245/006      2018-12-10      2019-12-10
         Unknown               Coaxial Cable       C-NJNJ-50       C-0200-01      2018-09-05      2019-09-05
           R&S                 Test Software         EMC32       Version8.53.0        N/A            N/A
           R&S             Two-line V-network       ENV 216          101614       2018-12-10      2019-12-10
           R&S                    L.I.S.N           ESH2-Z5       892107/021      2018-09-19      2019-09-19

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed traceable to National Primary Standards and International System of Units (SI).


Test Procedure

During the conducted emission test, the adapter of laptop was connected to the outlet of the first LISN and
the other support equipments were connected to the outlet of the second LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF

Herein,
VC: corrected voltage amplitude

VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN

The “Margin” column of the following data tables indicates the degree of compliance within the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                    Margin = Limit – Corrected Amplitude




                                                                                                    Page 9 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG181211006-00A

Test Results Summary

According to the recorded data in following table, the EUT complied with the FCC Part 15 B Class B.


Test Data

    Environmental Conditions

              Temperature:           22.9 C
         Relative Humidity:           36 %
            ATM Pressure:           101.8 kPa

     The testing was performed by Lily Xie on 2019-01-17.




                                                                                           Page 10 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG181211006-00A

Test Mode: Downloading

AC120V, 60Hz, Line:


                        80

                        70
                                                                                                  Quasi-Peak Limit
                        60
                                                                                                     Average Limit
                        50
         Level in dBμ




                        40

                        30

                        20

                        10

                        0
                        150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                              Frequency in Hz



     Frequency                 QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.184529                    56.0              9.000         L1      10.8         8.3      64.3          Compliance
      0.199835                    54.8              9.000         L1      10.6         8.8      63.6          Compliance
      0.206306                    49.8              9.000         L1      10.6        13.6      63.4          Compliance
      0.245835                    48.9              9.000         L1      10.3        13.0      61.9          Compliance
      0.259937                    47.8              9.000         L1      10.3        13.6      61.4          Compliance
      3.966160                    37.8              9.000         L1       9.8        18.2      56.0          Compliance

     Frequency                  Average           Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.199835                    41.8              9.000         L1      10.6        11.8      53.6          Compliance
      0.253797                    33.4              9.000         L1      10.3        18.2      51.6          Compliance
      0.259937                    33.8              9.000         L1      10.3        17.6      51.4          Compliance
      1.488418                    26.2              9.000         L1       9.8        19.8      46.0          Compliance
      1.875341                    26.9              9.000         L1       9.7        19.1      46.0          Compliance
      3.903455                    28.6              9.000         L1       9.8        17.4      46.0          Compliance




                                                                                                                 Page 11 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG181211006-00A

AC120V, 60Hz, Neutral:


                        80

                        70
                                                                                                  Quasi-Peak Limit
                        60
                                                                                                     Average Limit
                        50
         Level in dBμ




                        40

                        30

                        20

                        10

                        0
                        150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                              Frequency in Hz



     Frequency                 QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.190505                    53.6              9.000         N       10.7        10.4      64.0          Compliance
      0.247802                    47.4              9.000         N       10.3        14.4      61.8          Compliance
      0.255827                    47.0              9.000         N       10.3        14.6      61.6          Compliance
      1.936076                    39.6              9.000         N        9.8        16.4      56.0          Compliance
      2.252540                    35.4              9.000         N        9.8        20.6      56.0          Compliance
      4.094608                    36.6              9.000         N        9.8        19.4      56.0          Compliance

     Frequency                  Average           Bandwidth               Corr.      Margin    Limit
                                                                 Line                                         Comment
       (MHz)                    (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.187494                    40.4              9.000         N       10.7        13.7      54.1          Compliance
      0.251783                    33.1              9.000         N       10.3        18.6      51.7          Compliance
      0.255827                    34.5              9.000         N       10.3        17.1      51.6          Compliance
      1.936076                    28.5              9.000         N        9.8        17.5      46.0          Compliance
      2.234662                    26.2              9.000         N        9.8        19.8      46.0          Compliance
      4.127365                    27.9              9.000         N        9.8        18.1      46.0          Compliance




                                                                                                                 Page 12 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG181211006-00A


FCC §15.109 - RADIATED SPURIOUS EMISSIONS

EUT Setup

Below 1GHz:




Above 1GHz:




The radiated emission tests were performed in the 10 meters chamber test site for the range 30MHz to 1GHz
and the 3 meters chamber test site B for above 1GHz, using the setup accordance with the ANSI C63.4-2014.
The specification used was the FCC Part 15.109 Class B limits.




                                                                                            Page 13 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG181211006-00A

EMI Test Receiver Setup

The system was investigated from 30 MHz to 13.0 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

              Frequency Range             RBW          Video B/W        IF B/W      Measurement
             30 MHz – 1000 MHz           120 kHz        300 kHz         120 kHz           QP
                                          1 MHz          3 MHz             /             Peak
                Above 1 GHz                             Reduced
                                          1 MHz                            /             AVG
                                                         VBW

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.


Test Procedure

During the radiated emissions, the adapter of laptop was connected to the first AC floor outlet and the other
support equipments were connected to the second AC floor outlet.

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

The data was recorded in the Quasi-peak detection mode for below 1 GHz, peak and average detection mode
above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:

                                  Margin = Limit – Corrected Amplitude




                                                                                                Page 14 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG181211006-00A

Test Equipment List and Details

                                                                       Serial      Calibration    Calibration
    Manufacturer          Description             Model
                                                                     Number           Date         Due Date
        R&S            EMI Test Receiver          ESCI                100035       2018-08-03     2019-08-03
        Farad            Test Software          EZ-EMC               V1.1.4.2         N/A            N/A
    Sunol Sciences          Antenna                JB3              A060611-3      2017-07-21     2019-07-21
      Unknown            Coaxial Cable         C-NJNJ-50            C-1000-01      2018-09-05     2019-09-05
      Unknown            Coaxial Cable         C-NJNJ-50            C-0400-02      2018-09-05     2019-09-05
      Unknown            Coaxial Cable         C-NJNJ-50            C-0530-01      2018-09-24     2019-09-24
       Sonoma              Amplifier              310N                185914       2018-10-13     2019-10-13
       Agilent         Spectrum Analyzer        E4440A             SG43360054      2019-01-04     2020-01-04
    ETS-Lindgren         Horn Antenna             3115              000 527 35     2019-01-05     2022-01-04
      Unknown            Coaxial Cable         C-SJSJ-50            C-0800-01      2018-09-05     2019-09-05
                                            AFS42-00101800-2
        MITEQ              Amplifier                                 2001271       2018-09-05     2019-09-05
                                                 5-S-42


* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

    Environmental Conditions


             Temperature:              20.4~22.5 C
         Relative Humidity:            45~54 %
            ATM Pressure:           101.2~101.8 kPa

     * The testing was performed by Neil Liao & Vito Chen on 2019-01-18~2019-01-21.

     Test Result: Compliance




                                                                                                   Page 15 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG181211006-00A

Test Mode: Downloading

1) Below 1GHz:

    Horizontal




                  Receiver                     Correction      Cord.
   Frequency                                                                 Limit       Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                 (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)       (dBμV/m)
    60.0700         48.37           QP              -16.47    31.90          40.00         8.10
    143.4900        44.86          peak              -9.34    35.52          43.50         7.98
    186.1700        49.94           QP              -10.14    39.80          43.50         3.70
    311.3000        39.98          peak              -7.06    32.92          46.00        13.08
    468.4400        43.15          peak              -3.99    39.16          46.00         6.84
    624.6100        38.82           QP               -0.72    38.10          46.00         7.90




                                                                                         Page 16 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG181211006-00A

Vertical




                  Receiver                     Correction      Cord.
   Frequency                                                                 Limit       Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                 (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)       (dBμV/m)
    60.0700         47.28          peak             -16.47    30.81          40.00         9.19
    185.2000        47.02           QP              -10.12    36.90          43.50         6.60
    323.9100        40.50          peak              -7.12    33.38          46.00        12.62
    468.4400        40.88          peak              -3.99    36.89          46.00         9.11
    624.6100        35.56          peak              -0.72    34.84          46.00        11.16
    898.1500        32.16          peak              3.93     36.09          46.00         9.91




                                                                                         Page 17 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181211006-00A

2) Above 1GHz:

    Horizontal




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
   1798.000         57.95          peak             -7.79    50.16          74.00        23.84
   1798.000         44.23          AVG              -7.79    36.44          54.00        17.56
   1996.000         60.12          peak             -7.19    52.93          74.00        21.07
   1996.000         46.85          AVG              -7.19    39.66          54.00        14.34
   2392.000         54.95          peak             -6.54    48.41          74.00        25.59
   2392.000         42.25          AVG              -6.54    35.71          54.00        18.29




                                                                                        Page 18 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181211006-00A

Vertical




                  Receiver                     Correction     Cord.
   Frequency                                                                Limit       Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBμV/m)       (dB)
                  (dBμV)                        (dB/m)      (dBμV/m)
    1996.000        58.14          peak             -7.19    50.95          74.00        23.05
    1996.000        44.25          AVG              -7.19    37.06          54.00        16.94
    2392.000        60.12          peak             -6.54    53.58          74.00        20.42
    2392.000        46.19          AVG              -6.54    39.65          54.00        14.35
    4420.000        53.05          peak             -1.84    51.21          74.00        22.79
    4420.000        41.22          AVG              -1.84    39.38          54.00        14.62


                                   ****END OF REPORT****




                                                                                        Page 19 of 19



Document Created: 2019-02-28 15:56:24
Document Modified: 2019-02-28 15:56:24

© 2019 FCC.report