Test Report

FCC ID: 2AC7ISOLEF350N

Test Report

Download: PDF
FCCID_4156231

                                 FCC PART 22H, PART 24E
                   MEASUREMENT AND TEST REPORT
                                                              For

                                Interglobe Connection Corp
                          228 NW 30th Terrace, Doral, Florida, United States, 33122


                                      FCC ID: 2AC7ISOLEF350N


                Report Type:                                 Product Type:
                Original Report                              Mobile Phone


                     Report Number:          RDG181211003-00C

                         Report Date:        2018-12-28

                                             Jerry Zhang
                        Reviewed By:         EMC Manager
                    Test Laboratory:         Bay Area Compliance Laboratories Corp. (Dongguan)
                                             No.69 Pulongcun, Puxinhu Industry Area,
                                             Tangxia, Dongguan, Guangdong, China
                                             Tel: +86-769-86858888
                                             Fax: +86-769-86858891
                                             www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be used
by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. *
This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                             Report No.: RDG181211003-00C




                                                         TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  JUSTIFICATION .............................................................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................6
  CONFIGURATION OF TEST SETUP .................................................................................................................................6
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................7
SUMMARY OF TEST RESULTS ...............................................................................................................................8
FCC §1.1310 & §2.1093- RF EXPOSURE ....................................................................................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  TEST RESULT ...............................................................................................................................................................9
FCC §2.1047 - MODULATION CHARACTERISTIC ............................................................................................10
FCC § 2.1046, § 22.913 (A) & § 24.232 (C) - RF OUTPUT POWER ......................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  TEST PROCEDURE ......................................................................................................................................................11
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................12
  TEST DATA ................................................................................................................................................................12
FCC §2.1049, §22.917, §22.905 & §24.238 - OCCUPIED BANDWIDTH ..............................................................14
  APPLICABLE STANDARD ............................................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................14
  TEST DATA ................................................................................................................................................................15
FCC §2.1051, §22.917(A) & §24.238(A) - SPURIOUS EMISSIONS AT ANTENNA TERMINALS ..................17
  APPLICABLE STANDARD ............................................................................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................17
  TEST DATA ................................................................................................................................................................18
FCC §2.1053, §22.917 & §24.238 & §27.53 - SPURIOUS RADIATED EMISSIONS ...........................................21
  APPLICABLE STANDARD ............................................................................................................................................21
  TEST PROCEDURE ......................................................................................................................................................21
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................22
  TEST DATA ................................................................................................................................................................22
FCC §22.917(A) & §24.238(A)- BAND EDGES ........................................................................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................25
FCC §2.1055, §22.355 & §24.235 - FREQUENCY STABILITY ...........................................................................28

                                                                                                                                                               Page 2 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG181211003-00C


  APPLICABLE STANDARD ............................................................................................................................................28
  TEST PROCEDURE ......................................................................................................................................................28
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................29
  TEST DATA ................................................................................................................................................................29




                                                                                                                                                              Page 3 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG181211003-00C

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                          EUT Name:      Mobile Phone
                          EUT Model:     F350
                              FCC ID:    2AC7ISOLEF350N
                  Rated Input Voltage:   DC3.7V from Li-ion Rechargeable Battery or DC5V from adapter
                         Trame Name:     SOLE
           Adapter
                                Input:   100-240V, 50/60Hz
       Information
                               Output:   DC5.0V, 500mA
                  External Dimension:    103mm(L)* 51 mm(W)* 16.7 mm(H)
                       Serial Number:    181211003
                   EUT Received Date:    2018.12.11


Objective
This report is prepared on behalf of Interglobe Connection Corp in accordance with: Part 2-Subpart J, Part
22-Subpart H, and Part 24-Subpart E of the Federal Communications Commission’s rules.

The objective is to determine compliance with FCC Rules for output power, modulation characteristic,
occupied bandwidth, spurious emissions at antenna terminal, spurious radiated emission, frequency stability
and band edge.


Related Submittal(s)/Grant(s)
FCC Part 15B JBP submissions with FCC ID: 2AC7ISOLEF350N.
FCC Part 15C DSS submissions with FCC ID: 2AC7ISOLEF350N.


Test Methodology
All tests and measurements indicated in this document were performed in accordance with the Code of
Federal Regulations Title 47 Part 2, Sub-part J as well as the following parts:

Part 22 Subpart H - Public Mobile Services
Part 24 Subpart E - Personal Communication Services

Applicable Standards: TIA/EIA 603-D-2010.

All radiated and conducted emissions measurements were performed at Bay Area Compliance Laboratories
Corp.(Dongguan).




                                                                                                 Page 4 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG181211003-00C

Measurement Uncertainty
                Parameter                                  Measurement Uncertainty
        Occupied Channel Bandwidth                                  ±5 %
        RF output power, conducted                                ±0.61dB
                                                            30MHz~1GHz:5.85 dB
        Unwanted Emissions, radiated
                                                             1G~26.5GHz: 5.23 dB
       Unwanted Emissions, conducted                               ±1.5 dB
               Temperature                                           ±1℃
                 Humidity                                            ±5%
       DC and low frequency voltages                                ±0.4%
                Duty Cycle                                            1%


Test Facility
e Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located on the
No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC
Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. : CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian
radio equipment requirements, the CAB identifier: CN0022.




                                                                                                Page 5 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG181211003-00C


SYSTEM TEST CONFIGURATION
Justification
The EUT was configured for testing according to TIA/EIA-603-D 2010.

The test items were performed with the EUT operating at testing mode. The device supports GSM/GPRS
850 and 1900 Bands.


Equipment Modifications
No modification was made to the EUT.


Support Equipment List and Details

     Manufacturer                    Description                          Model        Serial Number
         R&S            Universial Radio Communication Tester           CMU200             106 891
         N/A                         ANTENNA                             N/A                 N/A


Configuration of Test Setup


                                CMU200
                                                                Antenna




                                                                  EUT




                                                                                                Page 6 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG181211003-00C

Block Diagram of Test Setup




                                                                      CMU200




                                                                                                1.0 Meter
                                                    EUT               Antenna




                             Non-Conductive Table
                             150 cm above Ground Plane

                                                          1.5 Meter




                                                                                                            Page 7 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG181211003-00C

SUMMARY OF TEST RESULTS

                  FCC Rules                         Description of Test                   Result

               §1.1310, §2.1093                        RF Exposure                     Compliance
                   §2.1046;
                                                     RF Output Power                   Compliance
           § 22.913 (a); § 24.232 (c);
                    § 2.1047                   Modulation Characteristics             Not Applicable
              § 2.1049; § 22.905
                                                  Occupied Bandwidth                   Compliance
              § 22.917; § 24.238
                   § 2.1051,
                                         Spurious Emissions at Antenna Terminal        Compliance
           § 22.917 (a); § 24.238 (a)
                   § 2.1053
                                              Spurious Radiation Emissions             Compliance
           § 22.917 (a); § 24.238 (a)
           § 22.917 (a); § 24.238 (a)       Out of band emission, Band Edge            Compliance

                   § 2.1055                Frequency stability vs. temperature
                                                                                       Compliance
              § 22.355; § 24.235             Frequency stability vs. voltage




                                                                                                       Page 8 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)              Report No.: RDG181211003-00C

FCC §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
FCC§1.1310 and §2.1093.


Test Result
Compliance, please refer to the SAR report: RDG181211003-20.




                                                                                 Page 9 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG181211003-00C

FCC §2.1047 - MODULATION CHARACTERISTIC
According to FCC § 2.1047(d), Part 22H & 24E there is no specific requirement for digital modulation,
therefore modulation characteristic is not presented.




                                                                                              Page 10 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG181211003-00C

FCC § 2.1046, § 22.913 (a) & § 24.232 (c) - RF OUTPUT POWER
Applicable Standard
According to FCC §2.1046 and §22.913 (a), the ERP of mobile transmitters and auxiliary test transmitters
must not exceed 7 watts.

According to FCC §2.1046 and §24.232 (C), mobile and portable stations are limited to 2 watts EIRP and the
equipment must employ a means for limiting power to the minimum necessary for successful
communications.

According to §24.232 (d) Power measurements for transmissions by stations authorized under this section
may be made either in accordance with a Commission-approved average power technique or in compliance
with paragraph (e) of this section. In both instances, equipment employed must be authorized in accordance
with the provisions of §24.51. In measuring transmissions in this band using an average power technique, the
peak-to-average ratio (PAR) of the transmission may not exceed 13 dB.


Test Procedure
GSM/GPRS/EGPRS

Function:          Menu select > GSM Mobile Station > GSM 850/1900
Press Connection control to choose the different menus
Press RESET > choose all the reset all settings
Connection         Press Signal Off to turn off the signal and change settings
Network Support > GSM + GPRS or GSM + EGSM
Main Service > Packet Data
Service selection > Test Mode A – Auto Slot Config. off
MS Signal          Press Slot Config Bottom on the right twice to select and change the number of time slots
and power setting
           > Slot configuration > Uplink/Gamma
           > 33 dBm for GPRS 850
           > 30 dBm for GPRS 1900
           > 27 dBm for EGPRS 850
           > 26 dBm for EGPRS 1900
BS Signal          Enter the same channel number for TCH channel (test channel) and BCCH channel
Frequency Offset >      + 0 Hz
Mode >                 BCCH and TCH
BCCH Level >            -85 dBm (May need to adjust if link is not stable)
BCCH Channel >          choose desire test channel [Enter the same channel number for TCH channel (test
channel) and BCCH channel]

Channel Type >         Off
P0 >                   4 dB
Slot Config >          Unchanged (if already set under MS signal)
TCH >                   choose desired test channel
Hopping >              Off
Main Timeslot >         3
Network                 Coding Scheme >        CS4 (GPRS) and MCS5 (EGPRS)


Bit Stream >           2E9-1 PSR Bit Stream
AF/RF                   Enter appropriate offsets for Ext. Att. Output and Ext. Att. Input
Connection              Press Signal on to turn on the signal and change settings


                                                                                                Page 11 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG181211003-00C

Test Equipment List and Details

                                                                       Serial        Calibration    Calibration
     Manufacturer            Description            Model
                                                                      Number            Date         Due Date
         R&S            EMI Test Receiver           ESCI               100035        2018-08-03     2019-08-03
     Sunol Sciences          Antenna                 JB3             A060611-3       2017-07-21     2019-07-21
        Agilent          Signal Generator          E8247C           MY43321350       2018-12-10     2019-12-10
        Agilent         Spectrum Analyzer          E4440A           SG43360054       2018-01-04     2019-01-04
       TDK RF             Horn Antenna            HRN-0118            130 084        2016-01-05     2019-01-04
     ETS-Lindgren         Horn Antenna              3115             000 527 35      2016-01-05     2019-01-04
                         Universal Radio
          R&S            Communication             CMU200              110 822       2018-12-14     2019-12-14
                              Tester
        Unknown           Coaxial Cable          C-NJNJ-50            C-0400-02      2018-09-05     2019-09-05
        Unknown           Coaxial Cable          C-NJNJ-50            C-0075-02      2018-09-05     2019-09-05
        Unknown           Coaxial Cable          C-NJNJ-50            C-2200-01      2018-09-05     2019-09-05
                                               UFA147-1-2362-       64639 231029-
     MICRO-COAX             Coaxial Cable                                            2018-02-24     2019-02-28
                                                  100100                 001
                           Adjustable Dipole
         EMCO                                       3121C             9109-753           N/A            N/A
                               Antenna
        Unknown             Coaxial Cable        C-SJ00-0010          C0010/01        Each time          /

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:             21.8~24.8 C
         Relative Humidity:              45~53 %
            ATM Pressure:             100.2~100.8 kPa

     * The testing was performed by Vito Chen & Tyler Pan from 2018-12-21 to 2018-12-24.

 Test Result: Compliance




                                                                                                      Page 12 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG181211003-00C

Conducted Output Power

                                          Cellular Band & PCS Band

                                                        Conducted Peak Output Power (dBm)
                            Channel
             Band                                        GPRS 1     GPRS 2 TX    GPRS 3             GPRS 4
                              No.            GSM
                                                         TX Slot        Slot     TX Slot            TX Slot
                               128           31.23        31.31        29.51      27.84              25.72
            Cellular           190           31.27        31.32        29.54      27.88              25.74
                               251           31.31        31.35        29.56      27.91              25.71
                               512           28.02        28.21        25.44      23.80              21.64
             PCS               661           28.41        28.56        25.04      23.21              21.26
                               810           28.65        28.78        24.69      22.76              20.52


ERP & EIRP
                                                     Part 22H
                                                Substituted Method
                          Receiver                                                Absolute
Frequency       Polar                 Substituted     Antenna                                   Limit        Margin
                          Reading                                  Cable Loss       Level
  (MHz)         (H/V)                    Level         Gain                                     (dBm)         (dB)
                           (dBµV)                                    (dB)          (dBm)
                                        (dBm)        (dBd/dBi)
                                            GSM 850 Middle Channel
 836.60             H      92.93         18.70       0.00        0.50               18.20       38.45         20.25
 836.60             V      100.80        29.54       0.00        0.50               29.04       38.45          9.41

                                                     Part 24E
                                                Substituted Method
                          Receiver                                                Absolute
Frequency       Polar                 Substituted   Antenna                                     Limit        Margin
                          Reading                                Cable Loss         Level
  (MHz)         (H/V)                    Level         Gain                                     (dBm)         (dB)
                           (dBµV)                                  (dB)            (dBm)
                                        (dBm)      (dBd/dBi)
                                           PCS 1900 Middle Channel
 1880.00           H        93.67        21.06         11.66       2.66             30.06       33.00          2.94
 1880.00           V        90.61        18.14         11.66       2.66             27.14       33.00          5.86

Note:
  1) The unit of Antenna Gain is dBd for frequency below 1GHz, and the unit of Antenna Gain is dBi for frequency
     above 1GHz.
  2) Absolute Level = Substituted Level - Cable loss + Antenna Gain
  3) Margin = Limit-Absolute Level




                                                                                                        Page 13 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG181211003-00C

FCC §2.1049, §22.917, §22.905 & §24.238 - OCCUPIED BANDWIDTH
Applicable Standard
FCC §2.1049, §22.917, §22.905, §24.238


Test Procedure
The RF output of the transmitter was connected to the simulator and the spectrum analyzer through
sufficient attenuation.
The 26 dB & 99% bandwidth was recorded.


                        EUT                      Splitter                   Spectrum Analyzer




                                              Universal Radio
                                              Communication
                                                  Tester


Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
      Manufacturer             Description            Model
                                                                     Number            Date         Due Date
           R&S              Spectrum Analyzer         FSP 38          100478        2018-12-10      2019-12-10

       E-Microwave           Two-way Spliter       ODP-1-6-2S       OE0120142        Each time         N/A

         Unknown              Coaxial Cable        C-SJ00-0010       C0010/01        Each time         N/A
                                                    KTRFBU-
        yzjingcheng           Coaxial Cable                          41005011        Each time         N/A
                                                     141-50

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                      Page 14 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                                         Report No.: RDG181211003-00C

Test Data
     Environmental Conditions

              Temperature:                           25 C
         Relative Humidity:                          44%
            ATM Pressure:                          100.4 kPa

    * The testing was performed by Andy Huang on 2018-12-25.


    Test Mode: Transmitting

    Test Result: Compliance. Please refer to the following table and plots.

                                                                                          99%                      26 dB
                                                 Test                                  Occupied                 Occupied
                         Band                                         Mode
                                                Channel                                Bandwidth                Bandwidth
                                                                                         (MHz)                    (MHz)
                        Cellular                                      GSM                 0.242                    0.318
                                                    M
                         PCS                                          PCS                 0.244                    0.318



                                                            GSM 850 Cellular Band
                                                                      * RBW 3 kHz      Delta 1 [T1 ]
                                                                      * VBW 10 kHz                 0.85 dB
                        Ref     34 dBm              * Att    40 dB      SWT 115 ms        318.000000000 kHz
                               Offset    4 dB                                          OBW242.000000000   kHz
                         30
                                                                                       Marker 1 [T1 ]
                                  D1 25.85 dBm                                                                  A
                                                                                                  -2.05   dBm
                         20                                                               836.440000000   MHz
                 1 PK
                                                                                       Temp 1 [T1 OBW]
                 MAXH
                                                             T1               T2                  11.08   dBm LVL
                         10                                                               836.480000000   MHz
                                                                                       Temp 2 [T1 OBW]
                                                                                   1              10.22   dBm
                         0              D2 -0.15 dBm    1
                                                                                          836.722000000   MHz


                         -10



                         -20
                                                                                                                3DB


                         -30



                         -40



                         -50



                         -60


                        Center 836.6 MHz                          100 kHz/                       Span 1 MHz




                 Date: 25.DEC.2018              22:17:03




                                                                                                                            Page 15 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                                      Report No.: RDG181211003-00C


                                                  GSM PCS1900 Cellular Band
                                                                   * RBW 3 kHz      Delta 1 [T1 ]
                                                                   * VBW 10 kHz                 0.05 dB
                       Ref    34 dBm              * Att   40 dB      SWT 115 ms        318.000000000 kHz
                             Offset    4 dB                                         OBW244.000000000   kHz
                       30
                                                                                    Marker 1 [T1 ]
                                                                                               -9.13   dBm   A

                       20                                                                1.879840000   GHz
                1 PK
                                D1 16.93 dBm                                        Temp 1 [T1 OBW]
                MAXH
                                                                                                3.34   dBm LVL
                       10                                                                1.879878000   GHz
                                                          T1                        Temp 2 [T1 OBW]
                                                                           T2
                                                                                                1.79   dBm
                       0
                                                                                         1.880122000   GHz
                                                     1                          1
                       -10            D2 -9.07 dBm



                       -20
                                                                                                             3DB


                       -30



                       -40



                       -50



                       -60


                       Center 1.88 GHz                         100 kHz/                       Span 1 MHz




                Date: 25.DEC.2018             22:27:25




                                                                                                                        Page 16 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG181211003-00C

FCC §2.1051, §22.917(a) & §24.238(a) - SPURIOUS EMISSIONS AT
ANTENNA TERMINALS
Applicable Standard
FCC §2.1051, §22.917(a) , §24.238(a).

The spectrum was to be investigated to the tenth harmonics of the highest fundamental frequency as
specified in § 2.1051.


Test Procedure
The RF output of the transceiver was connected to a spectrum analyzer and simulator through appropriate
attenuation. Sufficient scans were taken to show any out of band emissions up to 10th harmonic.

                      EUT                      Splitter                   Spectrum Analyzer



                                               CMU200


Test Equipment List and Details

                                                                      Serial       Calibration     Calibration
      Manufacturer             Description                Model
                                                                     Number           Date          Due Date
           R&S              Spectrum Analyzer             FSP 38      100478        2018-12-10      2019-12-10

       E-Microwave           Two-way Spliter        ODP-1-6-2S      OE0120142        Each time         N/A

         Unknown              Coaxial Cable         C-SJ00-0010      C0010/01        Each time         N/A
                                                     KTRFBU-
        yzjingcheng           Coaxial Cable                          41005011        Each time         N/A
                                                      141-50

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                      Page 17 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                                      Report No.: RDG181211003-00C

Test Data
     Environmental Conditions

              Temperature:                          25 C
         Relative Humidity:                         44%
            ATM Pressure:                         100.4 kPa

    * The testing was performed by Andy Huang on 2018-12-25.


   Test Result: Compliance. Please refer to the following plots.

                                                     GSM850_Middle Channel
                                                                       * RBW 100 kHz   Marker 1 [T1 ]
                                                                       * VBW 300 kHz             -32.40 dBm
                        Ref    34 dBm              * Att   40 dB        SWT 100 ms        681.840000000 MHz
                              Offset    4 dB
                        30

                                                                                                              B

                        20
                 1 PK
                 MAXH
                                                                                                              LVL   Fundamental
                        10



                        0



                        -10
                                 D1 -13 dBm

                        -20
                                                                                                              3DB


                        -30                                                       1



                        -40



                        -50



                        -60


                        Start 30 MHz                               97 MHz/                       Stop 1 GHz




                 Date: 25.DEC.2018             22:19:01




                                                                                                                          Page 18 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                                         Report No.: RDG181211003-00C



                                                                      * RBW 1 MHz         Marker 1 [T1 ]
                                                                      * VBW 3 MHz                   -23.99 dBm
                       Ref    34 dBm              * Att   40 dB        SWT 180 ms              7.228000000 GHz
                             Offset    4 dB
                       30

                                                                                                                 B

                       20
                1 PK
                MAXH
                                                                                                                 LVL
                       10



                       0



                       -10
                                D1 -13 dBm

                       -20                                                            1                          3DB


                       -30



                       -40



                       -50



                       -60


                       Start 1 GHz                            900 MHz/                             Stop 10 GHz




                Date: 25.DEC.2018             22:19:29


                                                   PCS 1900_ Middle Channel
                                                                      * RBW 100 kHz       Marker 1 [T1 ]
                                                                      * VBW 300 kHz                 -34.11 dBm
                       Ref    34 dBm              * Att   40 dB        SWT 100 ms             45.520000000 MHz
                             Offset    4 dB
                       30

                                                                                                                 B

                       20
                1 PK
                MAXH
                                                                                                                 LVL
                       10



                       0



                       -10
                                D1 -13 dBm

                       -20
                                                                                                                 3DB


                       -30
                       1


                       -40



                       -50



                       -60


                       Start 30 MHz                               97 MHz/                           Stop 1 GHz




                Date: 25.DEC.2018             22:21:43




                                                                                                                           Page 19 of 30


 Bay Area Compliance Laboratories Corp. (Dongguan)                                                      Report No.: RDG181211003-00C



                                                                    * RBW 1 MHz       Marker 1 [T1 ]
                                                                    * VBW 3 MHz                 -23.62 dBm
                        Ref    34 dBm              * Att   40 dB     SWT 250 ms           11.225000000 GHz
                              Offset    4 dB
                        30

                                                                                                                B
Fundamental             20
                 1 PK
                 MAXH
                                                                                                               LVL
                        10



                        0



                        -10
                                 D1 -13 dBm

                        -20                                                                  1
                                                                                                               3DB


                        -30



                        -40



                        -50



                        -60


                        Start 1 GHz                            1.25 GHz/                     Stop 13.5 GHz




                 Date: 25.DEC.2018             22:23:55




                                                                    * RBW 1 MHz       Marker 1 [T1 ]
                                                                    * VBW 3 MHz                 -26.49 dBm
                        Ref    14 dBm              * Att   20 dB     SWT 130 ms           18.063000000 GHz
                              Offset    4 dB
                        10

                                                                                                               B

                        0
                 1 PK
                 MAXH
                                                                                                               LVL
                        -10
                                 D1 -13 dBm

                        -20
                                                                                  1

                        -30



                        -40
                                                                                                               3DB


                        -50



                        -60



                        -70



                        -80


                        Start 13.5 GHz                         650 MHz/                          Stop 20 GHz




                 Date: 25.DEC.2018             22:24:25




                                                                                                                         Page 20 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG181211003-00C

FCC §2.1053, §22.917 & §24.238 & §27.53 - SPURIOUS RADIATED
EMISSIONS
Applicable Standard
FCC § 2.1053, §22.917, § 24.238 and § 27.53.


Test Procedure
The transmitter was placed on a wooden turntable, and it was transmitting into a non-radiating load which
was also placed on the turntable.

The measurement antenna was placed at a distance of 3 meters from the EUT. During the tests, the antenna
height and polarization as well as EUT azimuth were varied in order to identify the maximum level of
emissions from the EUT. The test was performed by placing the EUT on 3-orthogonal axis.

The frequency range up to tenth harmonic of the fundamental frequency was investigated.

Remove the EUT and replace it with substitution antenna. A signal generator was connected to the
substitution antenna by a non-radiating cable. The absolute levels of the spurious emissions were measured
by the substitution.

Spurious emissions in dB = 10 lg (TXpwr in Watts/0.001) – the absolute level

Spurious attenuation limit in dB = 43 + 10 Log10 (power out in Watts)




                                                                                               Page 21 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG181211003-00C

Test Equipment List and Details

                                                                       Serial        Calibration    Calibration
     Manufacturer             Description            Model
                                                                      Number            Date         Due Date
         R&S               EMI Test Receiver         ESCI             100035         2018-08-03     2019-08-03
     Sunol Sciences            Antenna               JB3             A060611-3       2017-07-21     2019-07-21
                           Adjustable Dipole
         EMCO                                        3121C            9109-753           N/A            N/A
                               Antenna
        Unknown             Coaxial Cable          C-NJNJ-50          C-1000-01      2018-09-05     2019-09-05
        Unknown             Coaxial Cable          C-NJNJ-50          C-0400-02      2018-09-05     2019-09-05
        Unknown              Coaxial Cable         C-NJNJ-50         C-0530-01       2018-09-24     2019-09-24
        Unknown              Coaxial Cable         C-NJNJ-50         C-0200-02       2018-09-05     2019-09-05
        Sonoma                 Amplifier             310N              185914        2018-10-13     2019-10-13
         Agilent            Signal Generator        E8247C          MY43321350       2018-12-10     2019-12-10
         Agilent           Spectrum Analyzer        E4440A          SG43360054       2018-01-04     2019-01-04
        TDK RF               Horn Antenna          HRN-0118           130 084        2016-01-05     2019-01-04
      ETS-Lindgren           Horn Antenna            3115            000 527 35      2016-01-05     2019-01-04
       Ducommun                                                     1007726-01
                             Horn Antenna        ARH-4223-02                         2016-11-18     2019-11-18
      Technolagies                                                      1304
       Ducommun                                                     1007726-02
                             Horn Antenna        ARH-4223-02                         2016-11-18     2019-11-18
      Technolagies                                                      1304
        Unknown              Coaxial Cable        C-SJSJ-50          C-0800-01       2018-09-05     2019-09-05
                                               AFS42-00101800-
         MITEQ                 Amplifier                               2001271       2018-09-05     2019-09-05
                                                    25-S-42
                                                BSF824-862MS-
        Sinoscite           Band-stop filter                           1438001       2018-06-16     2019-06-16
                                                   1438-001
                                               BSF1850-1910MS-
        Sinoscite           Band-stop filter                           0935V2        2018-06-16     2019-06-16
                                                    0935V2

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:              21.8~24.8 C
         Relative Humidity:               45~53 %
            ATM Pressure:              100.2~100.8 kPa

     * The testing was performed by Vito Chen & Tyler Pan from 2018-12-21 to 2018-12-24.


Test Result: Compliance.




                                                                                                      Page 22 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG181211003-00C

EUT Operation Mode: Transmitting

                                          Cellular Band (PART 22H)

30 MHz-10 GHz:
                                                Substituted Method
                          Receiver                                               Absolute
Frequency       Polar                 Substituted     Antenna                                  Limit       Margin
                          Reading                                 Cable Loss       Level
  (MHz)         (H/V)                    Level         Gain                                    (dBm)        (dB)
                           (dBµV)                                   (dB)          (dBm)
                                        (dBm)        (dBd/dBi)
                                      GSM850, Frequency:836.600 MHz
 1673.200         H         76.93       -37.28       10.6        0.73              -27.4       -13.0        14.4
 1673.200         V         77.86       -36.95       10.6        0.73              -27.1       -13.0        14.1
 2509.800         H         70.35       -42.67       13.1        1.25              -30.8       -13.0        17.8
 2509.800         V         68.13       -44.92       13.1        1.25              -33.1       -13.0        20.1
 3346.400         H         62.19       -48.47       13.8        1.61              -36.3       -13.0        23.3
 3346.400         V         61.44       -49.27       13.8        1.61              -37.1       -13.0        24.1
 4183.000         H         57.99       -51.01       14.0        1.56              -38.6       -13.0        25.6
 4183.000         V         56.10       -52.89       14.0        1.56              -40.5       -13.0        27.5
  935.980         H         38.96       -55.37        0.0        0.51              -55.9       -13.0        42.9
  893.300         V         39.08       -53.36        0.0        0.51              -53.9       -13.0        40.9


                                            PCS Band (PART 24E)

30 MHz-20 GHz:
                                                Substituted Method
                          Receiver                                               Absolute
Frequency       Polar                 Substituted     Antenna                                  Limit       Margin
                          Reading                                 Cable Loss       Level
  (MHz)         (H/V)                    Level         Gain                                    (dBm)        (dB)
                           (dBµV)                                   (dB)          (dBm)
                                        (dBm)        (dBd/dBi)
                                     GSM1900, Frequency:1880.000 MHz
 3760.000         H         62.33      -46.47        13.8         1.63             -34.3       -13.0        21.3
 3760.000         V         61.62      -47.05        13.8         1.63             -34.9       -13.0        21.9
 5640.000         H         54.12      -51.91        14.0         1.31             -39.2       -13.0        26.2
 5640.000         V         50.27      -55.64        14.0         1.31             -42.9       -13.0        29.9
  468.440         H         50.29      -55.56         0.0         0.36             -55.9       -13.0        42.9
  468.440         V         57.01      -46.15         0.0         0.36             -46.5       -13.0        33.5

Note:
  1) The unit of Antenna Gain is dBd for frequency below 1GHz, and the unit of Antenna Gain is dBi for frequency
     above 1GHz.
  2) Absolute Level = Substituted Level - Cable loss + Antenna Gain
  3) Margin = Limit-Absolute Level




                                                                                                       Page 23 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG181211003-00C


FCC §22.917(a) & §24.238(a)- BAND EDGES
Applicable Standard
FCC § 2.1053, §22.917, § 24.238.

Test Procedure
The RF output of the transmitter was connected to the input of the spectrum analyzer through sufficient
attenuation.

The center of the spectrum analyzer was set to block edge frequency.


                       EUT                      Splitter                  Spectrum Analyzer




                                             Universal Radio
                                             Communication
                                                 Tester


Test Equipment List and Details

                                                                      Serial       Calibration     Calibration
      Manufacturer             Description            Model
                                                                     Number           Date          Due Date
           R&S              Spectrum Analyzer         FSP 38          100478        2018-12-10      2019-12-10

       E-Microwave           Two-way Spliter       ODP-1-6-2S       OE0120142        Each time         N/A

         Unknown              Coaxial Cable        C-SJ00-0010       C0010/01        Each time         N/A
                                                    KTRFBU-
        yzjingcheng           Coaxial Cable                          41005011        Each time         N/A
                                                     141-50

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                      Page 24 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                                      Report No.: RDG181211003-00C

Test Data
     Environmental Conditions

              Temperature:                           25 C
         Relative Humidity:                          44%
            ATM Pressure:                          100.4 kPa

    * The testing was performed by Andy Huang on 2018-12-25.

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following plots.

                                                        GSM 850, Left Band Edge
                                                                        * RBW 3 kHz    Marker 1 [T1 ]
                                                                        * VBW 10 kHz             -15.10 dBm
                         Ref    30 dBm              * Att   40 dB        SWT 225 ms       823.980000000 MHz
                         30    Offset    4 dB

                                                                                                              A
                         20

                1 RM *
                MAXH
                         10
                                                                                                              LVL


                         0



                         -10
                                  D1 -13 dBm                        1


                         -20

                                                                                                              3DB
                         -30



                         -40



                         -50



                         -60


                         -70

                         Center 824 MHz                         200 kHz/                         Span 2 MHz




                Date: 25.DEC.2018               22:14:35




                                                                                                                        Page 25 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                                        Report No.: RDG181211003-00C


                                                       GSM 850, Right Band Edge
                                                                        * RBW 3 kHz      Marker 1 [T1 ]
                                                                        * VBW 10 kHz               -13.31 dBm
                         Ref    30 dBm              * Att   40 dB           SWT 225 ms      849.024000000 MHz
                         30    Offset    4 dB

                                                                                                                A
                         20

                1 RM *
                MAXH
                         10
                                                                                                                LVL


                         0



                         -10                                            1
                                  D1 -13 dBm

                         -20

                                                                                                                3DB
                         -30



                         -40



                         -50



                         -60


                         -70

                         Center 849 MHz                         200 kHz/                           Span 2 MHz




                Date: 25.DEC.2018               22:14:01


                                                       GSM 1900, Left Band Edge
                                                                        * RBW 3 kHz      Marker 1 [T1 ]
                                                                        * VBW 10 kHz               -23.53 dBm
                         Ref    30 dBm              * Att   40 dB           SWT 225 ms        1.849980000 GHz
                         30    Offset    4 dB

                                                                                                                A
                         20

                1 RM *
                MAXH
                         10
                                                                                                                LVL


                         0



                         -10
                                  D1 -13 dBm

                         -20                                        1

                                                                                                                3DB
                         -30



                         -40



                         -50



                         -60


                         -70

                         Center 1.85 GHz                        200 kHz/                           Span 2 MHz




                Date: 25.DEC.2018               22:28:42




                                                                                                                          Page 26 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                                    Report No.: RDG181211003-00C


                                                      GSM 1900, Right Band Edge
                                                                    * RBW 3 kHz      Marker 1 [T1 ]
                                                                    * VBW 10 kHz               -21.22 dBm
                         Ref    30 dBm              * Att   40 dB       SWT 225 ms        1.910020000 GHz
                         30    Offset    4 dB

                                                                                                            A
                         20

                1 RM *
                MAXH
                         10
                                                                                                            LVL


                         0



                         -10
                                  D1 -13 dBm

                                                                    1
                         -20

                                                                                                            3DB
                         -30



                         -40



                         -50



                         -60


                         -70

                         Center 1.91 GHz                        200 kHz/                       Span 2 MHz




                Date: 25.DEC.2018               22:29:45




                                                                                                                      Page 27 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG181211003-00C

FCC §2.1055, §22.355 & §24.235 - FREQUENCY STABILITY
Applicable Standard
FCC § 2.1055 (a), § 2.1055 (d), §22.355, §24.235

According to §22.355, the carrier frequency of each transmitter in the Public Mobile Services must be
maintained within the tolerances given in Table below:

                    Frequency Tolerance for Transmitters in the Public Mobile Services

             Frequency Range         Base, fixed       Mobile>3 watts        Mobile ≤ 3 watts
                  (MHz)                (ppm)               (ppm)                 (ppm)
                   25 to 50              20.0               20.0                   50.0
                  50 to 450               5.0                5.0                   50.0
                 450 to 512              2.5                 5.0                   5.0
                 821 to 896              1.5                 2.5                   2.5
                 928 to 929.             5.0                N/A                    N/A
                 929 to 960.             1.5                N/A                    N/A
                2110 to 2220             10.0               N/A                    N/A

According to §24.235, the frequency stability shall be sufficient to ensure that the fundamental emissions
stays within the authorized frequency block.


Test Procedure
Frequency Stability vs. Temperature: The equipment under test was connected to an external DC power
supply and the RF output was connected to communication test set via feed-through attenuators. The EUT
was placed inside the temperature chamber. The DC leads and RF output cable exited the chamber through
an opening made for the purpose.

After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the
communication test set.

Frequency Stability vs. Voltage: An external variable DC power supply was connected to the battery
terminals of the equipment under test. The voltage was set from 85% to 115% of the nominal value and was
then decreased until the transmitter light no longer illuminated; i.e., the battery end point. The output
frequency was recorded for each battery voltage.



                         Temperature
                          Chamber


                                   EUT                           Test
                                                               Equipment




                                                                                                 Page 28 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG181211003-00C

Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
      Manufacturer             Description            Model
                                                                     Number            Date         Due Date
                             Universal Radio
           R&S               Communication           CMU200          106 891        2018-12-14      2019-12-14
                                  Tester
                           Constant temperature
          ESPEC                                      ESX-4CA         018 463        2018-03-26      2019-03-26
                           and humidity Tester
         Unknown              Coaxial Cable         C-SJ00-0010      C0010/01        Each time         N/A

          UNI-T                 Multimeter            UT39A        M130199938       2018-07-24      2019-07-24

      Pro instrument        DC Power Supply          pps3300         3300012           N/A             N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                25 C
         Relative Humidity:               44%
            ATM Pressure:               100.4 kPa

     * The testing was performed by Andy Huang on 2018-12-25.

     Test Result: Compliance.




                                                                                                      Page 29 of 30


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG181211003-00C

    Cellular Band

                                  GMSK, Middle Channel, fc = 836.6 MHz
                                                    Frequency   Frequency
                     Temperature        Voltage                               Limit
                                                      Error       Error
                           ℃             VDC           Hz         ppm          ppm
                          -30                           1        0.00120
                          -20                          -2       -0.00239
                          -10                           3        0.00359
                           0                            1        0.00120
                           10             3.7           3        0.00359
                           20                           0        0.00000        2.5
                           30                          -2       -0.00239
                           40                           1        0.00120
                           50                          -1       -0.00120
                           20             3.5           1        0.00120
                           20             4.2           3        0.00359

    PCS Band

                                  GMSK, Middle Channel, fc = 1880.0 MHz
                                                    Frequency   Frequency
                     Temperature        Voltage
                                                      Error       Error       Results
                           ℃             VDC           Hz         ppm
                          -30                          -2       -0.00106
                          -20                           4        0.00213
                          -10                           2        0.00106
                           0                            3        0.00160
                           10             3.7           1        0.00053
                           20                           0        0.00000       Pass
                           30                           4        0.00213
                           40                          -3       -0.00160
                           50                           1        0.00053
                           20             3.5          -1       -0.00053
                           20             4.2           2        0.00106



                                   ***** END OF REPORT *****




                                                                                             Page 30 of 30



Document Created: 2019-01-24 13:39:48
Document Modified: 2019-01-24 13:39:48

© 2024 FCC.report