SET2018-12562 EMC Report

FCC ID: 2AC6AP80

Test Report

Download: PDF
FCCID_4063977

                                                                  Report No.: SET2018-12562




             EMC TEST REPORT
      Report No.: SET2018-12562
  Product Name: Industrial tablet
          FCC ID: 2AC6AP80
      Model No. : P80
       Applicant: Shenzhen Chainway Information Technology Co.,Ltd.
       Address: 9/F, Building 2, Daqian Industrial Park, Longchang Rd., District 67,
                 Bao'an, Shenzhen
  Received Date: 2018-08-23
     Tested Date: 2018-08-23—2018-10-15
       Issued by: CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd.

                     Building 28/29, East of Shigu Xili Industrial Zone, Nanshan District
   Lab Location:
                     Shenzhen, Guangdong 518055, China

                     Tel: 86 755 26627338        Fax: 86 755 26627238




    This test report consists of 18 pages in total. It may be duplicated completely for legal
use with the approval of the applicant. It should not be reproduced except in full, without
the written approval of our laboratory. The client should not use it to claim product
endorsement by CCIC-SET. The test results in the report only apply to the tested sample.
The test report shall be invalid without all the signatures of testing engineers, reviewer and
approver. Any objections must be raised to CCIC-SET within 15 days since the date when
the report is received. It will not be taken into consideration beyond this limit.




CCIC-SET/T(00)                                                                  Page 1 of 18


                                                                                  Report No.: SET2018-12562



                                                    Test Report

Product Name ....................... :        Industrial tablet

Model No. ............................ :      P80

Applicant ............................... :   Shenzhen Chainway Information Technology Co.,Ltd.

Applicant Address................ :           9/F, Building 2, Daqian Industrial Park, Longchang Rd.,
                                              District 67, Bao'an, Shenzhen

Manufacturer ........................ :       Shenzhen Chainway Information Technology Co.,Ltd.

Manufacturer Address ......... :              9/F, Building 2, Daqian Industrial Park, Longchang Rd.,
                                              District 67, Bao'an, Shenzhen

Test Standards...................... :        47 CFR Part 15 Subpart B: Radio Frequency Devices

Test Result ............................ :    PASS

Tested by ............................. :

                                              Yun Lei Fang        Test Engineer                2018.10.15

Reviewed by ......................... :


                                              Chris You    Senior Engineer                    2018.10.15

Approved by ......................... :


                                                                                              2018.10.15
                                              Zhu Qi, Manager




CCIC-SET/T(00)                                                                                Page 2 of 18


                                                                                                            Report No.: SET2018-12562


                                                    TABLE OF CONTENTS
1.      GENERAL INFORMATION ....................................................................................................4

1.1     EUT Description .........................................................................................................................4
1.2     Test Standards and Results ........................................................................................................5
1.3     Facilities and Accreditations ......................................................................................................6
1.3.1      Facilities ....................................................................................................................................6
1.3.2      Test Environment Conditions ....................................................................................................6
1.3.3      Measurement Uncertainty .........................................................................................................6

2.      TEST CONDITIONS SETTING...............................................................................................7

2.1     Test Peripherals ..........................................................................................................................7
2.2     Test Mode ....................................................................................................................................7
2.3     Test Setup and Equipments List ................................................................................................7
2.3.1      Conducted Emission..................................................................................................................7
2.3.2      Radiated Emission .....................................................................................................................9

3.      47 CFR PART 15B REQUIREMENTS .................................................................................. 11

3.1     Conducted Emission ................................................................................................................. 11
3.1.1      Requirement ............................................................................................................................ 11
3.1.2      Test Description ...................................................................................................................... 11
3.1.3      Test Result ............................................................................................................................... 11
3.2     Radiated Emission ....................................................................................................................14
3.2.1      Requirement ............................................................................................................................14
3.2.2      Test Description ......................................................................................................................15
3.2.3      Test Result ...............................................................................................................................15


                                                                Change History
        Issue                   Date                                                      Reason for change
         1.0                 2018.10.15                                                     First edition




CCIC-SET/T(00)                                                                                                                       Page 3 of 18


                                                                       Report No.: SET2018-12562



1.          GENERAL INFORMATION

1.1         EUT Description
EUT Name .......................... .:       Industrial tablet
FCC ID ................................ .:   2AC6AP80
Trade Name…………………:                           CHAINWAY
Brand Name…………………:                           CHAINWAY
Hardware Version ................ .:         N/A
Software Version .................. :        N/A

Note1:The EUT is a Industrial tablet, it supports the following operating frequency band:
      GSM/WCDMA/LTE, 2.4GHz/4GHz WLAN, Bluetooth, NFC,GPS;
Note2:The EUT is equipped with a T-Flash card slot; equipped with a USB port which can be
        connected to the ancillary equipments.
Note 3:The highest operation frequency or processor operate frequency is 1.3GHz.
Note 4:The two models have been tested and were recorded in this report.
Note 5:For a more detailed description, please refer to Specification or User’s Manual supplied by the
       applicant and/or manufacturer.




CCIC-SET/T(00)                                                                          Page 4 of 18


                                                                        Report No.: SET2018-12562


1.2        Test Standards and Results
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

          No.        Identity                       Document Title
          1          47 CFR Part 15                 Radio Frequency Devices
                     Subpart B 2017

Test detailed items/section required by FCC rules and results are as below:

          No.   Section     Description                                              Result
          1     15.107      Conducted Emission                                       PASS
          2     15.109      Radiated Emission                                        PASS

NOTE:

      (1) The EUT has been tested according to 47 CFR Part 15 Subpart B,Class B.The test procedure
      is according to ANSI C63.4:2014.




CCIC-SET/T(00)                                                                             Page 5 of 18


                                                                      Report No.: SET2018-12562


1.3       Facilities and Accreditations

1.3.1     Facilities

      CNAS-Lab Code: L1659

      CCIC-SET is a third party testing organization accredited by China National Accreditation
      Service for Conformity Assessment (CNAS) according to ISO/IEC 17025. The accreditation
      certificate number is L1659.

      FCC-Registration No.: CN5031

      CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd. EMC Laboratory has been
      registered and fully described in a report filed with the FCC (Federal Communications
      Commission). The acceptance letter from the FCC is maintained in our files. Designation
      Number: CN5031, valid time is until December 31, 2018.

      ISED Registration: 11185A-1

      CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd. EMC Laboratory has been
      registered by Certification and Engineering Bureau of Industry Canada for the performance of
      radiated measurements with Registration No. 11185A-1 on Aug. 04, 2016, valid time is until
      Aug. 03, 2019.

      NVLAP Lab Code: 201008-0

      CCIC-SET is a third party testing organization accredited by NVLAP according to ISO/IEC
      17025. The accreditation certificate number is 201008-0.

1.3.2     Test Environment Conditions

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                      15°C - 35°C
 Relative Humidity (%):                 25% -75%
 Atmospheric Pressure (kPa):            86kPa-106kPa

1.3.3     Measurement Uncertainty

The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.

 Uncertainty of Conducted Emission:     Uc = 3.6 dB (k=2)
 Uncertainty of Radiated Emission:      Uc = 4.5 dB (k=2)



CCIC-SET/T(00)                                                                        Page 6 of 18


                                                                                    Report No.: SET2018-12562



2.        TEST CONDITIONS SETTING

2.1       Test Peripherals
The following is a listing of the EUT and peripherals utilized during the performance of EMC test:

Support Equipment:

             Description            Brand name             Model              Serial No.           FCCID
              Notebook                   ThinkPad          E430C              A131101550            N/A
            Micro SD card                SanDisk               N/A                  N/A             N/A
                Mouse                    Logitech          M100r               25011051             DOC

Support Cable:

                    Description                Shield Type           Ferrite Core         Length
                PC Power adapter Cable         Un- shielding             No                1.2m
                     Mouse Cable               Un- shielding             No                1m

2.2       Test Mode
        The EUT configuration of the emission tests is T TransFlash Card + EUT + PC+Mouse.


2.3       Test Setup and Equipments List

2.3.1     Conducted Emission




CCIC-SET/T(00)                                                                                     Page 7 of 18


                                                                     Report No.: SET2018-12562




A. Test Setup:



      < 40cm >                 < 80cm >
                                                                          Common
                                                                          Antenna



                   EUT

                                                              Pulse Limiter
     < 80cm >                                      LISN
                                                                          Receiver


                                                                           System
                                                                          Simulator

The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains
through a LISN which provides 50Ω/50µH of coupling impedance for the measuring instrument. The
Common Antenna is used for the call between the EUT and the System Simulator (SS). A Pulse
Limiter is used to protect the measuring instrument. The factors of the whole test system are
calibrated to correct the reading.

B. Equipments List:

                                                                       Calibration     Calibration
  Description         Manufacturer         Model        Serial No.
                                                                          Date         Due. Date
 Test Receiver        KEYSIGHT            N9038A      A141202036       2017.12.13      2018.12.12
    LISN         ROHDE&SCHWARZ            ENV216      A140701847       2018.01.08      2019.01.07
    Cable         MATCHING PAD              W7            /            2018.04.02      2019.04.01




CCIC-SET/T(00)                                                                        Page 8 of 18


                                                  Report No.: SET2018-12562


2.3.2   Radiated Emission

A. Test Setup:

    1) For radiated emissions from 30MHz to1GHz




    2) For radiated emissions above 1GHz




CCIC-SET/T(00)                                                  Page 9 of 18


                                                                    Report No.: SET2018-12562


B. Test Procedure

    The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on
    of the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high
    insulating Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a
    variable-height antenna master tower.

    For the test Antenna:

1) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
   Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
   varied from 1m to 4m above the ground to determine the maximum value of the field strength.
   The emission levels at both horizontal and vertical polarizations should be tested.

C. Equipments List:

                                                                        Calibration   Calibration
  Description          Manufacturer          Model        Serial No.
                                                                           Date       Due. Date
 Test Receiver    ROHDE&SCHWARZ              ESIB7        A0501375      2018.08.05    2019.08.05
Semi-Anechoic
                            Albatross     9m*6m*6m        A0412372      2018.05.09    2019.05.09
   Chamber
Test Antenna -
                              ETC         MCTD 2786      A150402239     2018.06.10    2019.06.10
    Bi-Log
Test Antenna –
                  ROHDE&SCHWARZ              HF906        A0304225      2018.05.26    2019.05.25
     Horn
                                          SAC-5MAC
   Anechoic
                            Albatross     12.8x6.8x6.4    A0304210      2018.05.09    2019.05.09
   Chamber
                                               m
                                            MITEQ
   Amplifier
                  ROHDE&SCHWARZ           AFS42-0010      A0509366      2018.06.04    2019.06.04
  1G~18GHz
                                              1800
  Amplifier        Compliance Direction
                                          PAP-0203H       A0509377      2018.06.04    2019.06.04
 20M~3GHz                System
                                          SUCOFLEX
    Cable               SUNHNER                                /        2018.06.04    2019.06.04
                                             100
                                          SUCOFLEX
    Cable               SUNHNER                           MY1758/4      2018.06.04    2019.06.04
                                             104




CCIC-SET/T(00)                                                                    Page 10 of 18


                                                                       Report No.: SET2018-12562



3.       47 CFR PART 15B REQUIREMENTS

3.1      Conducted Emission

3.1.1    Requirement

According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

                                                    Conducted Limit (dBµV)
 Frequency range (MHz)
                                       Quasi-peak                              Average
        0.15 - 0.50                     66 to 56                               56 to 46
         0.50 - 5                          56                                     46
          5 - 30                           60                                     50
Note:
a) The limit subjects to the Class B digital device.
b) The lower limit shall apply at the band edges.
c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

3.1.2    Test Description

See section 2.3.1 of this report.

3.1.3    Test Result

The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average
(AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins
from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and
N phase lines of the power mains connected to the EUT are performed. All test modes are considered,
refer to recorded points and plots below.

Note:
  Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a
Nominal 120V AC,50/60Hz) for which the device is capable of operation. A device rated for 50/60
Hz operation need not be tested at both frequencies provided the radiated and line conducted
emissions are the same at both frequencies.




CCIC-SET/T(00)                                                                        Page 11 of 18


                                                                                            Report No.: SET2018-12562


Test voltage and frequency (120V AC,60Hz)

A. Mains terminal disturbance voltage, L phase



         Level in dB¦Ì
        100

         90                                                                                456.000 kHz
               190.500 kHz                             312.000 kHz                         43.617 dB¦Ì
         80    48.661 dB¦Ì                             44.977 dB¦Ì

         70

                                                                           FCC Part 15 Class B Voltage on Mains QP
         60

                                                                           FCC Part 15 Class B Voltage on Mains AV
         50

         40

         30

         20

         10
                  613.500 kHz                   1.000500 MHz                            1.653000 MHz
          0       43.461 dB¦Ì                    42.762 dB¦Ì                             42.312 dB¦Ì

         -10



          150k           300    400 500     800 1M            2M      3M    4M 5M 6       8 10M            20M       30M
                                                        Frequency in Hz



                                                     (Plot A: L Phase)

                                 Conducted Disturbance at Mains Terminals
                                                       L Test Data
                       QP                                                                AV
   Frequen              Measurem                                   Frequen                Measurem
                 Cable                            Limits                           Cable                               Limits
      cy                ent Value                                     cy                   ent Value
                 Loss                            (dBV)                            Loss                               (dBV)
    (MHz)                (dBV)                                     (MHz)                   (dBV)
    0.1905        0.10    45.13                      64.00           0.1905         0.10     33.62                     54.00
    0.3120        0.15    43.42                      59.90           0.3120         0.15     34.80                     49.90
    0.4560        0.15    39.37                      56.80           0.4560         0.15     31.52                     46.80
    0.6135        0.18              38.43            56.00           0.6135         0.18             29.50             46.00
    1.0005        0.23              34.33            56.00           1.0005         0.23             26.84             46.00
    1.6530        0.26              36.82            56.00           1.6530         0.26             27.53             46.00

CCIC-SET/T(00)                                                                                                   Page 12 of 18


                                                                                           Report No.: SET2018-12562


B. Mains terminal disturbance voltage, N phase



         Level in dB¦Ì
        100

         90
                     496.500 kHz                    654.000 kHz                  874.500 kHz
                     43.130 dB¦Ì                    42.345 dB¦Ì                  40.493 dB¦Ì
         80

         70

                                                                          FCC Part 15 Class B Voltage on Mains QP
         60

                                                                          FCC Part 15 Class B Voltage on Mains AV
         50

         40

         30

         20

         10
                      1.063500 MHz                      1.459500 MHz                      1.779000 MHz
                       40.052 dB¦Ì                       40.747 dB¦Ì                       41.816 dB¦Ì
            0

         -10



            150k          300   400 500    800 1M            2M     3M     4M 5M 6       8 10M            20M       30M
                                                        Frequency in Hz



                                                (Plot B: N Phase)

                                 Conducted Disturbance at Mains Terminals
                                                       N Test Data
                         QP                                                               AV
  Frequen                 Measureme                                                        Measureme
                   Cable                         Limits           Frequency         Cable              Limits
     cy                    nt Value                                                          nt Value
                   Loss                         (dBV)              (MHz)           Loss              (dBV)
   (MHz)                    (dBV)                                                           (dBV)
   0.4965           0.10     40.90                  56.10          0.4965            0.10     31.87    46.10
   0.6540          0.15            39.02            56.00          0.6540            0.15            29.63                46.00
   0.8745          0.15            36.80            56.00          0.8745            0.15            28.01                46.00
   1.0635          0.18            37.61            56.00          1.0635            0.18            27.75                46.00
   1.4595          0.23            36.69            56.00          1.4595            0.23            25.91                46.00
    1.7790     0.26                38.36            56.00          1.7790            0.26            26.61                46.00
Test Result: PASS


CCIC-SET/T(00)                                                                                                  Page 13 of 18


                                                                         Report No.: SET2018-12562


3.2        Radiated Emission

3.2.1      Requirement

According to FCC section 15.109, the field strength of radiated emissions from unintentional
radiators at a distance of 3 meters shall not exceed the following values:

        Frequency           Field Strength          Field Strength Limitation at 3m Measurement Dist
      range (MHz)          µV/m            Dist             (uV/m)                  (dBuV/m)
      0.009 - 0.490     2400/F(kHz)       300m       10000* 2400/F(kHz)      20log 2400/F(kHz) + 80
      0.490 - 1.705     2400/F(kHz)        30m        100* 2400/F(kHz)       20log 2400/F(kHz) + 40
      1.705 - 30.00         30             30m              100*30                 20log 30 + 40
       30.0 - 88.0          100             3m                100                    20log 100
       88.0 - 216.0         150             3m                150                    20log 150
      216.0 - 960.0         200             3m                200                    20log 200
      Above 960.0           500             3m                500                    20log 500

      a)     As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength
           limits are based on average detector. When average radiated emission measurements are
           specified in this part, including emission measurements below 1000MHz, there also is a limit
           on the radio frequency emissions, as measured using instrumentation with a peak detector
           function, corresponding to 20dB above the maximum permitted average limit for the
           frequency being investigated unless a different peak emission limit is otherwise specified in
           the rules.

      b)    Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m
           above the ground to determine the maximum value of the field strength.

      c) For below 1G :QP detector RBW 120kHz ,VBW 300kHz.

      d) For Above 1G: PK detector RBW 1MHz,VBW 3MHz for PK value ;AV detector RBW
         1MHz, VBW 10Hz for AV value.

Note:
1) The tighter limit shall apply at the boundary between two frequency range.
2) Limitation expressed in dBuV/m is calculated by 20log Emission Level(uV/m).
3) If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by using
   the formula of Ld1 = Ld2 * (d2/d1)2.
   Example:
   F.S Limit at 30m distance is 30uV/m, then F.S Limitation at 3m distance is adjusted as
   Ld1 = L1 = 30uV/m * (10)2 = 100 * 30uV/m.




CCIC-SET/T(00)                                                                          Page 14 of 18


                                                                         Report No.: SET2018-12562


3.2.2    Test Description

See section 2.3.2 of this report.

3.2.3    Test Result

The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
more than the limits, and that have narrow margins from the limits will be re-measured with AV and
QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered to
perform the tests. All test modes are considered, refer to recorded points and plots below.

The amplitude of spurious emissions which are attenuated more than 20 dB below the permissible
value need not be reported.

Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis test
condition was recorded in this test report.




CCIC-SET/T(00)                                                                          Page 15 of 18


                                                                                             Report No.: SET2018-12562


C. Radiation disturbances, antenna polarization:Vertical

    Marker:                     30 MHz                      33.5 dBµV/m

     Level [dBµV/m]
   80

   70

   60

   50

   40

   30

   20

   10

     0
          30M         50M         70M        100M                     200M        300M          500M        700M        1G
                                                Frequency [Hz]

          MES 18-13393 V4
          LIM FCC Cl.B F QP/AV           FCC ClassB, field strength




                                    (Plot C: Test Antenna Vertical 30M - 1G)


                                                       Antenna
        Frequency     QuasiPeak         Bandwidth                       Limit       Margin
                                                        height                                   Antenna           Verdict
          (MHz)       (dBμV/m)            (kHz)                        (dBμV/m)      (dB)
                                                         (cm)

          30.41         33.15            120.000         208.0          40.00        6.85        Vertical           Pass

          36.25         32.24            120.000         129.0          40.00        7.76        Vertical           Pass

          70.82         22.88            120.000         147.0          40.00        17.12       Vertical           Pass

         157.58         26.59            120.000         241.0          43.50        16.91       Vertical           Pass

         276.19         28.97            120.000         169.0          46.00        17.03       Vertical           Pass

         931.96         37.18            120.000         207.0          46.00        8.82        Vertical           Pass




CCIC-SET/T(00)                                                                                               Page 16 of 18


                                                                                             Report No.: SET2018-12562


D. Radiation disturbances, antenna polarization: Horizontal

    Marker:                 267.154309 MHz                               39.25 dBµV/m

     Level [dBµV/m]
   80

   70

   60

   50

   40

   30

   20

   10

     0
          30M         50M         70M        100M                     200M        300M          500M         700M        1G
                                                Frequency [Hz]

          MES 18-13393 H4
          LIM FCC Cl.B F QP/AV           FCC ClassB, field strength




                                  (Plot D:          Test Antenna Horizontal 30M - 1G)



                                                       Antenna
        Frequency     QuasiPeak         Bandwidth                       Limit       Margin
                                                        height                                   Antenna            Verdict
          (MHz)       (dBμV/m)            (kHz)                        (dBμV/m)      (dB)
                                                         (cm)

          30.00         30.86            120.000         223.0          40.00        9.14       Horizontal           Pass

          35.66         26.13            120.000         209.0          40.00        13.87      Horizontal           Pass

         267.87         39.60            120.000         126.0          46.00        6.40       Horizontal           Pass

         347.13         29.67            120.000         268.0          46.00        16.33      Horizontal           Pass

         560.68         31.80            120.000         214.0          46.00        14.20      Horizontal           Pass

         657.88         33.91            120.000         364.0          46.00        12.09      Horizontal           Pass




Test Result: PASS




CCIC-SET/T(00)                                                                                                Page 17 of 18


                                                                      Report No.: SET2018-12562


E. Radiation disturbances, antenna polarization: Horizontal




                          (Plot E: Test Antenna Horizontal 1G – 18G)

F. Radiation disturbances, antenna polarization: Vertical




                           (Plot F: Test Antenna Vertical 1G – 18G)




CCIC-SET/T(00)                                                                     Page 18 of 18



Document Created: 2018-11-07 15:33:10
Document Modified: 2018-11-07 15:33:10

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC