Test Report

FCC ID: 2AC3T-B36T10RA

Test Report

Download: PDF
FCCID_2398344

                             849 NW State Road 45
                             Newberry, FL 32669 USA
                             Ph: 888.472.2424 or 352.472.5500
                             Fax: 352.472.2030
                             Email: info@timcoengr.com
                             Website: www.timcoengr.com



FCC PART 15.249 & IC RSS-210 (i8) ANNEX A2.9
      UNLICENSED INTENTIONAL RADIATOR
                COMBINED TEST REPORT

            Applicant     BUILDING 36 TECHNOLOGIES, LLC
                              35 HIGHLAND CIRCLE
             Address               SUITE 300
                             NEEDHAM MA 02494 USA
              FCC ID             2AC3T-B36T10RA
      IC Certification
                                12323A-B36T10RA
             Number
       Model Number                    B36-T10
  Product Description              THERMOSTAT
FCC Standard Applied              47 CFR §15.249
    Industry Canada
                            RSS-210 Issue 8 Annex A2.9
    Standard Applied
Date Sample Received                  9/11/2014
         Date Tested                   9/18/14
           Tested By                  Sid Sanders
        Approved By                Cory Leverett
      Report Number          1611AUT14TestReport.docx
         Test Results          PASS                 FAIL


THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL
 WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC.


                                      Table of Contents


GENERAL REMARKS L. ....0.0.000 00e ce ce ce ce cce n m n n n n n n nc cce n mm n n n e n nc cn www en ce 3
GENERAL INFORMATION: .2 .2.0.00 00e ce ce ce n en n n e e e enc enc cce ww www en n nc cce ce ww n ww e en 4
TEST RESULTS SUMMARY .
TEST PROCEDURES ..
RADIATION INTERFERENCE.
99% POWER OCCUPIED BANDWIDTH
LOWER BANDEDGE ..
UPPER BANDEDGE
DUTY CYOLE:
POWER LINE CONDUCTED INTERFERENCE
EMC EQUIPMENT LIST




APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                                       Page 2 of 14


GENERAL REMARKS

The attached report shall not be reproduced         except    in   full without the written
permission of Timco Engineering Inc.

Summ ary

The device under test does:
K     fulfill the general approval requirements as identified in this test report
C     not fulfill the general approval requirements as identified in this test report

Attestations

This equipment has been tested in accordance with the standards identified in this
test report. To the best of my knowledge and belief, these tests were performed using
the measurement procedures described in this report.

All instrumentation and accessories used to test products for compliance to the
indicated standards are calibrated regularly in accordance with 1SO 17025: 2005
requirements.




| attest that the necessary measurements were made, under my supervision, at:

Timco Engineering Inc.
849 NW State Road 45
Newberry, FI 32669

Authorized Signatory Name:




Sid Sanders
Project Manager
Date: 9/ 20/ 14


Contents

APPLILCANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:     2AC3T—B36T10RA
1C:          12323A—B36T10RA
REPORT:     V:\B\BUILDING 3611611 AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                             Page 3 of 14


GENERAL INFORMATI ON

EUT Specification
                       The test results relate only to the items tested.
      Applicable Standards       FCC Part 15.249 & 1C RSS—210 (i8), RSS—GEN (i3)
            EUT Description     WIRELESS THERMOSTAT
                      FCCID     2AC3T—B36T1ORA
   1C Certification Number       12323A—B36T1 ORA
             Model Number        B36—T10
      Operating Frequency       TX:     908.4 & 916 MHz            RX: Same
            No. of Channels      2                Modulations
                                C] 110—120vac/50— 60Hz when Charging
         EUT Power Source       |:| DC Power

                                K Battery Operated Exclusively

                                 C] Prototype           C Pre—                E] Production
                    Test Item                           Production

         Type of Equipment [X] Fixed                    C Mobite              CJ Portable
                                 FCC Rules require that the antenna connector be unique.
        Antenna Connector       There is no antenna connector, it has an integrated PCB
                                antenna
                                Timco Engineering Inc. located at 849 NW State Road 45
                Test Facility
                                 Newberry, FL 32669 USA.
     Conditions in the Test     Temperature: 26°C
                laboratory       Relative humidity: 50%
                                 Placed into continuous transmit mode with 100% duty
              Test Exercise
                                cycle
    Revision History of EUT      None

TEST RESULTS SUMMARY

     FCC Rules Part No.              Industry Canada Rules             RESULTS — Pass/ Fail/ NA
 15.249 Fundamental Emission           RSS—210 (i8) ANNEX                           Pass
                                       A2.9, RSS—GEN (i3)
15.249 & 15.209 Harmonics &            RSS—210 (i8) ANNEX                           Pass
Spurious                               A2.9, RSS—GEN (i3)
   15.205 & 2.202 Occupied              RSS—GEN (i3), 4.6                           Pass
          Bandwidth
  15.249 & 15.205 Bandedge               RSS—GEN (i3), 4.6                          Pass
         Compliance
 15.207 Power Line Emissions            RSS—GEN (13),    7.2.4                      N/A
Table of Contents
APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                                     Page 4 of 14


TEST PROCEDURES

Radiation Interference: ANSI ©63.4—2003 using a spectrum analyzer, a preselector, a
quasi—peak adapter, and an appropriate antenna. The analyzer was calibrated in dB above a
microvolt at the output of the antenna. The resolution bandwidth was 100 kHz with an
appropriate sweep speed and the video bandwidth was 300 kHz up to 1 GHz and 1 MHz with a
video BW of 3 MHz above 1      GHz. When an emission was found, the table was rotated to
produce the maximum signal strength. The antenna was placed in both the horizontal and
vertical planes and the worst case emissions were reported. The spectrum was searched to at
least the tenth (10) harmonic of the fundamental. Emissions were scanned from 30MHz to the
tenth harmonic of the fundamental frequency at three places in the band. All emissions
greater than 20 dB from the limit are not reported.

Formula Of Conversion Factors: The field strength at 3m was established by adding the
meter reading of the spectrum analyzer (which is set to read in units of dBuV) to the antenna
correction factor supplied by the antenna manutacturer. The antenna correction factors are
stated in terms of dB. The gain of the preselector was accounted for in the spectrum analyzer
meter reading.

       Example:
       Freq (MHz)    Meter Reading        + ACF             L = FS
       33            20 dBuV              + 10.36 dB    + 0.5 = 30.86 dBuV/m @ 3m

Power Line Conducted Interference: The procedure used was ANSI C63.4—2003 using a
50uH LISN. Both lines were observed. The bandwidth of the spectrum analyzer was 10kHz
with an appropriate sweep speed. The spectrum was scanned from 0.15 to 30 MHz.

Occupied Bandwidth:       A small sample of the transmitter output was fed into the spectrum
analyzer and the attached plot was printed. The vertical scale is set to —10 dBm per division.

ANSI C63.4—2003 10.1 Measurement Procedures: The EUT was placed on a table 80 cm
high and with dimensions of 1m by 1.5m. The EUT was placed in the center of the table (1.5m
side). The table used for radiated measurements is capable of continuous rotation..

When an emission was found, the table was rotated to produce the maximum signal strength.
At this point, the antenna was raised and lowered from 1m to 4m. The antenna was placed in
both the horizontal and vertical planes. Emissions attenuated more than 20 dB below the
permissible value are not reported.




Table of Contents




APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                             Page 5 of 14


RADIATION I NTERFERENCE

Rules Part No.:    FCC 15.249, 15.209 & IC RSS—210 (i8) ANNEX A2.9, RSS—GEN (i3)

Requirements:
                   Frequency              |                 Limits
                               Part 15.209 & RSS—GEN (i3)
                 9 to 490 kHz                 2400/F (kHz) uV/m @300 meters
               490 to 1705 kHz                24000/F (kHz) uV/m @ 30 meters
              1705 kHz to 30 MHz                 29.54 dBuV/m @ 30 meters
                     30 — 88                      40.0 dBuV/m @3 meters
                    80 — 216                      43.5 dBuV/m @3 meters
                   216 — 960                      46.0 dBuV/m @3 meters
                   Above 960                      54.0 dBuV/m @3 meters
                       Part 15.249 & RSS—210     (i8) ANNEX A.2.9
          Fundamental 902 — 928 MHz              94.0 dBuV/m @3 meters
         Fundamental 2.4 — 2.4835 GHz            94.0 dBuV/m @3 meters
                  Harm onics                     54.0 dBuV/m @3 meters

Test Data: Peak Detector Used for all Measurement‘s.

 Tuned     Emission     Meter        Ant.        Coax     Correction      Field      Margin
 Freq.       Freq.     Reading     Polarity      Loss       Factor      Strength       dB
  MHz        MHz        dBuV                      dB         dB/m       dBuV/m
 908.9      908.90      52.7          H          2.89        23.30          78.39    15.61
 908.9      908.90      60.3          v          2.89        23.30          85.99     8.01
 908.9     1,817.90      2.9          H          2.96        30.62          36.48    17.52
 908.9     1,817.90      5.2          v          2.96        30.62          38.78    15,22
 908.9     2,725.50      5.8          H          341         33.06          41.77    12.28
 908.9     2,725.50     10.2          v          341         33.06          46.67    7.38
 908.9     3,633,20      6.1          H          4.17        33.39          43.66    10.34
 908.9     3,633,.20     9.7          v          4.17        33.39          47.26     6.74
 908.9     4,542.10      8.7          v          4.77        34.10          47.57     6.43
 908.9     4,546.10      0.1          H          4.77        34.10          38.97    15.08
 908.9     5,453,.50     1.2          H          5.14        34.64          40.97    13.08
 908.9     5,453,.60     1.0          v          5.14        34.64          40.78    18,22
 908.9     5,962,60      4.4          H          5.29        35.44          45.13     8.87
 908.9     6,262,40     11.1          v          5.398       35.71          52.19     1L.81
 908.9     6,326,.60     1.2          H          5.40        35.76          42.35    11.65
 908.9     6,871.50      0.5          H          5.56        35.90          41.96    12.04
 908.9     7,271.50      L1           H          5.76        35.79          42.60    11.40
 908.9     7,780.50      5.1          H          6.07        35.81          46.98    7.02
 908.9     8,180,50      L1           H          6.27        35.94          43.26    10.74
 908.9     8,180,50      T.5          v          6.27        35.94          49.71    4.29
 908.9     8,690.70      1.5          H          6.48        36.04          44.02     9.98
 908.9     9,089.40      0.5          v          6.63        36.19          49.32    10.68
 908.9     9,089.40      0.8          H          6.63        36.19          493.62   10.38


APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                             Page 6 of 14


RADIATI ON | NTERFERENCE

 Tuned      Emission    Meter      Ant.     Coax   Correction     Field      Margin
 Freq.        Freq.    Reading   Polarity   Loss     Factor     Strength       dB
  MHz         MHz       dBuV                 dB      dB/m       dBuV/m
  916.0      916.00     45.4        H       240      23.36          7116     22.84
  916.0      916.00     53.6        v       240      23.36          79.36    14.64
  916.0     1,832,00     4.3        v       2.99     30.69          37.98    16.02
  916.0     1,832,00     5.6        H       2.99     30.69          39.28    14.72
  916.0     2,748.00    10.3        v       3.42     33.10          46.82     7.18
  916.0     2,748.00    14.2        H       3.42     33.10          50.68     3.32
  916.0     3,664.00     9.3        v       4.20     33.48          46.93     7.07
  916.0     3,664.00    15.1        H       4.20     33.48          52.76     1.24
  916.0     3,664.00    15.1        H       4.20     33.48          52.76     1.24
  916.0     4,580.00     4.1        v       4.79     34.10          42.99    11.01
  916.0     4,580.00    10.2        H       4.79     34.10          49.09     4.91
  916.0     5,496.00     L1         v       5.15     34.70          40.95    18.05
  916.0     5,496.00     1.6        H       5.15     34.70          41.45    12,55
  916.0     6,412,00     5.8        H       5.42     35.83          46.55     7.45
  916.0     6,412,00     6.4        v       5.42     35.83          47.65     6.35
  916.0     7,328.00     2.7        v       5.80     35.77          44.27     9.73
  916.0     7,328.00     4.0        H       5.80     35.77          45.57     8.483
  916.0     8,244.00     3.2        H       6.30     35.95          45.45     8.55
  916.0     8,244.00     4.3        v       6.30     35.95          46.55    7.A5
  916.0     9,160.00     0.6        H       6.65     36.26          498.51   10.49
  916.0     9,160,00     0.6        v       6.65     36.26          498.51   10,.49




Results: EUT meets the FCC & Industry Canada Requirements.


Table of Contents




APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                     Page 7 of 14


99% POWER OCCUPIED BANDWIDTH

Rules Part No.:         15.249 (d)

Requirements: The field strength of any emissions appearing outside the bandedges and up
to 10 kHz above and below the band edges shall be attenuated at least 50 dB below the level
of the carrier or to the general limits of 15.249.

Test Data:
CH 1 99% OBW = 93.05 KHz



                                                           sos
                                                       ow ds
                                                        Temp|1

                                                             ads .
                                                          temp |2




      Center   908.4192308 iz                               Span     365.1825 kiz




Date: 17.9E9.2014—   16146153



Table of Contents


APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                            Page 8 of 14


99% POWER OCCUPIED BANDWIDTH

Rules Part No.:         RSS—GEN (i3), 4.6

Requirements:       . Emissions radiated outside of the specified frequency bands, except for the
harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the
highest general field strength limits listed in RSS—GEN, whicheveris less stringent.


Test Data:

CH 2 99% OBW = 115.44 KHz




     Center   o16 itz                  s6—2007 kite/             Span 262.007   Jate




Results: EUT meets the FCC & Industry Canada Requirements.
Table of Contents

APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                                Page 9 of 14


LOW ER BANDEDGE


& _ rec   62 asuv      *ace   10 as
                                       *rew 100 ki
                                            300 Jate
                                        SWt 5 me




                                             H                            &




    stare. so1.5 i2               12180 i/               stop s13.38 im




RESULTS: MEETS FCC REQUIREMENTS




APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                       Page 10 of 14


UPPER BANDEDGE




      Rres   62 aBuy              *ace   10 as           10 ms




                                                                                    »a
                                                                                    #s




                                                                                    ane




      stare 910.06 mtc                       1804 mme/              stop 928.5 iz




Date: 22.9E9.2014      15102142




RESULTS: MEETS FCC REQUIREMENTS




APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                                 Page 11 of 14


DUTY CYCLE:


 NOT APPLICABLE




Table of Contents




APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                    Page 12 of 14


POW ER LINE CONDUCTED I NTERFERENCE

Rules Part No.:     15.207, & RSS—GEN (i3), 7.2.4

Requirements:
                    Frequency           Quasi Peak Limits            Average Limits
                      (MHz)                  (dBuv)                         (dBuV)
                    0.15 — 0.5               66 — 56                    56 — 46

                    0.5 — 5.0                  56                             46

                     5.0 — 30                  60                             50


Test Data: NOT APPLICABLE EUT is Battery powered.




Table of Contents



APPLICANT:   BUILDING 36 TECHNOLOGIES LLC.
             2AC3T—B36T1ORA
             12323A—B36T1 0RA
             V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                            Page 13 of 14


EMC EQUIPMENT LIST

  Device       Manufacturer         Model          Serial        Cal/ Char   Due Date
                                                  Number            Date
 Antenna:             Eaton       94455—1          1057         06/ 14/ 13   06/ 14/ 15
Biconnical          Chamber
Antenna:             Eaton         96005           1243         05/ 31/13    05/31/15
    Log—
  Periodic
  3—Meter           Panashield       N/ A           N/ A        12/ 31713    12/31/15
   Sem i—
 Anechoic
 Chamber
 Antenna:      ETS—Lindgren         3117        00035923        O6/13/14     06/13/16
  Double—        Chamber
  Ridg ed
 Horn/ ETS
  Horn 1
 EMI Test            Rohde &       ESIB 40        100274        08/12/14     08/12/16
Receiver R           Schw arz
 & S ESIB
     40
 EMI Test            Rohde &       ESU 40         100320        03/11/14     03/11/16
Receiver R           Schw arz
 & S ESU
    40

* EMI RECEIVER SOFTWARE VERSION
The receiver firmware used was version 4.43 Service Pack 3




Table of Contents




APPLICANT: BUILDING 36 TECHNOLOGIES LLC.
FCC ID:    2AC3T—B36T1ORA
1C:        12323A—B36T1 0RA
REPORT:    V:\B\BUILDING 361161 1AUT14\161 1 AUT14TESTREPORTREV1.DOCX

                                                             Page 14 of 14



Document Created: 2019-06-07 04:45:52
Document Modified: 2019-06-07 04:45:52

© 2024 FCC.report