Test Report DFS

FCC ID: 2ABZ2-GM1925

Test Report

Download: PDF
FCCID_4317145

            FCC RF Test Report                                                      Report No. : FZ942205




DYNAMIC FREQUENCY SELECTION
                                  DFS Test Report
      APPLICANT                         :   OnePlus Technology (Shenzhen) Co., Ltd
      EQUIPMENT                         :   Smart Phone
      BRAND NAME                        :   ONEPLUS
      MODEL NAME                        :   GM1925
      FCC ID                            :   2ABZ2-GM1925
      STANDARD                          : FCC Part 15 Subpart E
      CLASSIFICATION                    : (NII) Unlicensed National Information Infrastructure

      The product was received on Apr. 22, 2019 and completely tested on May 09, 2019. We,
      Sporton International (Shenzhen) Inc., would like to declare that the tested sample has been
      evaluated in accordance with the procedures and shown to be compliant with the applicable
      technical standards.
      The test results in this report apply exclusively to the tested model / sample. Without written
      approval of Sporton International (Shenzhen) Inc., the test report shall not be reproduced
      except in full.




      Reviewed by: Derreck Chen / Supervisor




          Approved by: Eric Shih / Manager

                              Sporton International (ShenZhen) Inc.
   1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen, 518055
                                             People’s Republic of China

Sporton International (Shenzhen) Inc.                                     Page Number        : 1 of 21
TEL : +86-755-86379589                                                    Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                    Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


             FCC RF Test Report                                                                                               Report No. : FZ942205



                                                 TABLE OF CONTENTS

1   GENERAL DESCRIPTION .......................................................................................................................... 5
     1.1     Applicant ........................................................................................................................................... 5
     1.2     Feature of Equipment Under Test .................................................................................................... 5
     1.3     Product Specification of Equipment Under Test ............................................................................... 6
     1.4     Testing Site ....................................................................................................................................... 7
     1.5     Applied Standards ............................................................................................................................ 7
     1.6     Support Unit used in test configuration and system ......................................................................... 7
2   REQUIREMENTS AND PARAMETERS FOR DFS TEST .......................................................................... 8
     2.1     Applicability of DFS Requirements ................................................................................................... 8
     2.2     Interference Threshold values, Master or Client incorporating In-Service Monitoring ................... 10
     2.3     DFS Response requirement values ................................................................................................ 11
     2.4     Short Pulse Radar Test Waveforms ............................................................................................... 12
3   CALIBRATION SETUP AND DFS TEST RESULTS ................................................................................ 13
     3.1     Calibration of Radar Waveform ...................................................................................................... 13
     3.2     In-Service Monitoring: Channel Move Time, Channel Closing Transmission Time and
             Non-Occupancy Period ................................................................................................................... 15
4   LIST OF MEASURING EQUIPMENT ........................................................................................................ 21

APPENDIX A. SETUP PHOTOGRAPHS




Sporton International (Shenzhen) Inc.                                                                           Page Number        : 2 of 21
TEL : +86-755-86379589                                                                                          Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                                                          Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                       Report No. : FZ942205




                                           REVISION HISTORY

   REPORT NO.           VERSION                              DESCRIPTION                     ISSUED DATE

     FZ942205            Rev. 01        Initial issue of report                              Jun. 10, 2019




Sporton International (Shenzhen) Inc.                                      Page Number        : 3 of 21
TEL : +86-755-86379589                                                     Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                     Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                           Report No. : FZ942205




      SUMMARY OF DYNAMIC FREQUENCY SELECTION TEST

                        Bandwidth
        UNII               and             Description         Measured                Limit                Result
                         Channel

                                        Channel Move Time     0.438815 sec            10 sec                 Pass

                          80MHz                                 <200ms +            200 ms +
    U-NII-2C                             Channel Closing
                         (CH106)                                  2.4 ms     aggregate of 60 ms over         Pass
 5470-5725MHz                           Transmission time
                         5530MHz                              (aggregate)     remaining 10 s period
                                         Non-Occupancy       No transmission
                                         Period and Client     or Beacons          30 minutes                Pass
                                           Beacon Test          occurred
     Note: Since the product is client without radar detection function, only Channel Move Time, Channel
     Closing Transmission Time and Non-Occupancy Period Test are required to be performed.




Sporton International (Shenzhen) Inc.                                          Page Number        : 4 of 21
TEL : +86-755-86379589                                                         Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                         Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                      Report No. : FZ942205


1 General Description
1.1 Applicant
       OnePlus Technology (Shenzhen) Co., Ltd
       18C02, 18C03, 18C04 and 18C05, Shum Yip Terra Building, Binhe Avenue North, Futian District,
       Shenzhen




1.2 Feature of Equipment Under Test
                                                  Product Feature
        Equipment                               Smart Phone
        Brand Name                              ONEPLUS
        Model Name                              GM1925
        FCC ID                                  2ABZ2-GM1925
                                                GSM/CDMA/WCDMA/LTE/5G NR
                                                WLAN 2.4GHz 802.11b/g/n HT20/HT40
                                                WLAN 5GHz 802.11a/n HT20/HT40
        EUT supports Radios application
                                                WLAN 5GHz 802.11ac VHT20/VHT40/VHT80
                                                Bluetooth BR / EDR / LE
                                                NFC/GNSS
        IMEI Code                               990013610023140
        HW Version                              31
        SW Version                              9.5.5.GM25CC
        EUT Stage                               Production Unit
       Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications
       or user's manual for more detailed description.




Sporton International (Shenzhen) Inc.                                     Page Number        : 5 of 21
TEL : +86-755-86379589                                                    Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                    Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                           Report No. : FZ942205


1.3       Product Specification of Equipment Under Test
                                        Product Specification subjective to this standard
        DFS Function                                Client without radar detection function
                                                    5260 MHz ~ 5320 MHz
        Tx/Rx Channel Frequency Range
                                                    5500 MHz ~ 5720 MHz
                                                    <5260 MHz ~ 5320 MHz>
                                                    802.11a
                                                    802.11n HT20
                                                    802.11n HT40
                                                    802.11ac VHT20
                                                    802.11ac VHT40
                                                    802.11ac VHT80
        EUT support WLAN function
                                                    <5500 MHz ~ 5720 MHz >
                                                    802.11a
                                                    802.11n HT20
                                                    802.11n HT40
                                                    802.11ac VHT20
                                                    802.11ac VHT40
                                                    802.11ac VHT80
                                                    802.11a/n : OFDM (BPSK / QPSK / 16QAM / 64QAM)
        Type of Modulation
                                                    802.11ac : OFDM (BPSK / QPSK / 16QAM / 64QAM / 256QAM)




Sporton International (Shenzhen) Inc.                                          Page Number        : 6 of 21
TEL : +86-755-86379589                                                         Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                         Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


             FCC RF Test Report                                                       Report No. : FZ942205


1.4 Testing Site
       Sporton International (Shenzhen) Inc. is accredited to ISO/IEC 17025:2017 by American Association for

       Laboratory Accreditation with Certificate Number 5145.01.

        Test Firm               Sporton International (Shenzhen) Inc.
                           1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen,
                           518055 People’s Republic of China
        Test Site Location TEL: +86-755-86379589
                           FAX: +86-755-86379595

                                   Sporton Site No.       FCC Designation No.     FCC Test Firm Registration No.
        Test Site No.
                                        DFS01-SZ                 CN1256                         421272



1.5 Applied Standards
       According to the specifications of the manufacturer, the EUT must comply with the requirements of the
       following standards:
             FCC Part 15 Subpart E
             FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02
             FCC KDB 905462 D03 UNII Clients Without Radar Detection New Rules v01r02


       Remark: All test items were verified and recorded according to the standards and without any deviation
       during the test.



1.6 Support Unit used in test configuration and system
        Item Equipment Trade Name           Model Name          FCC ID    HW / FW Version       Power Cord

        1.     WLAN AP          Cisco     Air-CAP3702E-A-K9   LDK102087         N/A           Shielded, 1.8 m

                                                                                                   AC I/P:

                                                                                             Unshielded, 1.2 m
        2.     Notebook        Lenovo           G450              N/A           N/A
                                                                                                  DC O/P:

                                                                                              Shielded, 1.8 m




Sporton International (Shenzhen) Inc.                                      Page Number        : 7 of 21
TEL : +86-755-86379589                                                     Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                     Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                            Report No. : FZ942205


2 Requirements and Parameters for DFS Test
2.1 Applicability of DFS Requirements
       EUT is client and operates as client without radar detection function.

           Table 1: Applicability of DFS Requirements Prior to Use of a Channel

                                                                        Operational Mode

                                                                                Client             Client With
                       Requirement
                                                         Master           Without Radar               Radar
                                                                            Detection               Detection

                 Non-Occupancy Period                      Yes             Not required                 Yes


                DFS Detection Threshold                    Yes             Not required                 Yes

           Channel Availability Check Time                 Yes             Not required            Not required

               U-NII Detection Bandwidth                   Yes             Not required                 Yes



            Table 2: Applicability of DFS requirements during normal operation

                                                                        Operational Mode
                                                                                Client                 Client
                       Requirement
                                                         Master           Without Radar            With Radar
                                                                            Detection               Detection
                DFS Detection Threshold                    Yes             Not required                 Yes
         Channel Closing Transmission Time                 Yes                   Yes                    Yes
                   Channel Move Time                       Yes                   Yes                    Yes
               U-NII Detection Bandwidth                   Yes             Not required                 Yes
                    Client Beacon Test                     N/A                   Yes                    Yes




Sporton International (Shenzhen) Inc.                                           Page Number        : 8 of 21
TEL : +86-755-86379589                                                          Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                          Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                         Report No. : FZ942205




                                                                        Operational Mode
         Additional requirements for devices                Master or
                                                                                              Client
            with multiple bandwidth modes                  Client With
                                                                                  Without Radar Detection
                                                        Radar Detection
            U-NII Detection Bandwidth and                All BW modes
                                                                                          Not required
            Statistical Performance Check                must be tested
                                                                                      Test using the widest
           Channel Move Time and Channel              Test using widest BW
                                                                                      BW mode available
               Closing Transmission Time                 mode available
                                                                                            for the link
                       All other tests                Any single BW mode                  Not required
        Note
        Frequencies selected for statistical performance check (Section 7.8.4) should include
        several frequencies within the radar detection bandwidth and frequencies near the edge of
        the radar detection bandwidth. For 802.11 devices it is suggested to select frequencies in
        each of the bonded 20 MHz channels and the channel center frequency.




Sporton International (Shenzhen) Inc.                                        Page Number        : 9 of 21
TEL : +86-755-86379589                                                       Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                       Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                           Report No. : FZ942205


2.2 Interference Threshold values, Master or Client incorporating
    In-Service Monitoring
                      Maximum Transmit Power                             Value (see notes 1, 2, and 3)
        EIRP ≥ 200 milliwatt                                                        -64 dBm
        EIRP < 200 milliwatt and
                                                                                    -62 dBm
        power spectral density < 10 dBm/MHz
        EIRP < 200 milliwatt that do not meet the power
                                                                                    -64 dBm
        spectral density requirement
        Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
        Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the
        test transmission waveforms to account for variations in measurement equipment. This will ensure
        that the test signal is at or above the detection threshold level to trigger a DFS response.
        Note 3: EIRP is based on the highest antenna gain. For MIMO devices refer to KDB Publication
        662911 D01.
       The radar Detection Threshold, lowest antenna gain is the parameter of Interference radar DFS
       detection threshold, The Interference Detection Threshold is the ( -62dBm) + (0) [dBi]+ 1 dB= -61 dBm.




Sporton International (Shenzhen) Inc.                                          Page Number        : 10 of 21
TEL : +86-755-86379589                                                         Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                         Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                              Report No. : FZ942205


2.3 DFS Response requirement values
                         Parameter                                               Value
        Non-occupancy period                          Minimum 30 minutes
        Channel Availability Check Time               60 seconds
        Channel Move Time                             10 seconds See Note 1.
        Channel Closing Transmission Time             200 milliseconds + an aggregate of 60 milliseconds over
                                                      remaining 10 second period. See Notes 1 and 2.
        U-NII Detection Bandwidth                     Minimum 100% of the 99% power bandwidth
                                                      See Note 3.
        Note 1: The instant that the Channel Move Time and the Channel Closing Transmission Time begins
        is as follows:
           • For the Short pulse radar Test Signals this instant is the end of the Burst.
           • For the Frequency Hopping radar Test Signal, this instant is the end of the last radar Burst
           generated.
           • For the Long Pulse radar Test Signal this instant is the end of the 12 second period defining the
           radar transmission.
        Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the
        beginning of the Channel Move Time plus any additional intermittent control signals required to
        facilitate Channel changes (an aggregate of 60 milliseconds) during the remainder of the 10 second
        period. The aggregate duration of control signals will not count quiet periods in between
        transmissions.
        Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 is used and for each
        frequency step the minimum percentage of detection is 90%. Measurements are performed with no
        data traffic.




Sporton International (Shenzhen) Inc.                                           Page Number        : 11 of 21
TEL : +86-755-86379589                                                          Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                          Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                         Report No. : FZ942205


2.4 Short Pulse Radar Test Waveforms
       As the EUT is a Client Device with no Radar Detection, only one type radar pulse is required for the
       testing. Radar Pulse type 0 was used in the evaluation of the Client device for the purpose of
       measuring the Channel Move Time and the Channel Closing Transmission Time.


                                                                                Minimum
                     Pulse
        Radar                                                                 Percentage of          Minimum
                     Width        PRI (µsec)     Number of Pulses
         Type                                                                  Successful               Trials
                     (µsec)
                                                                                Detection
           0            1               1428             18                         60%                  30



                                        Test A
           1            1                                                          60%                   30
                                        Test B



           2           1-5         150-230             23-29                        60%                  30
           3          6-10         200-500             16-18                        60%                  30
           4          11-20        200-500             12-16                        60%                  30
        Aggregate (Radar Types 1-4)                                                 80%                  120


       Test A: 15 unique PRI values randomly selected from the list of 23 PRI values in Table 5a
       Test B: 15 unique PRI values randomly selected within the range of 518-3066 μsec, with a minimum
       increment of 1 μsec, excluding PRI values selected in Test A


       A minimum of 30 unique waveforms are required for each of the short pulse radar types 2 through 4.
       For short pulse radar type 1, the same waveform is used a minimum of 30 times. If more than 30
       waveforms are used for short pulse radar types 2 through 4, then each additional waveform must also
       be unique and not repeated from the previous waveforms.


       If more than 30 waveforms are used for Short Pulse Radar Type 1, then each additional waveform is
       generated with Test B and must also be unique and not repeated from the previous waveforms in Tests
       A or B.


       The aggregate is the average of the percentage of successful detections of short pulse radar types 1-4.




Sporton International (Shenzhen) Inc.                                        Page Number        : 12 of 21
TEL : +86-755-86379589                                                       Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                       Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                         Report No. : FZ942205


3 Calibration Setup and DFS Test Results
3.1 Calibration of Radar Waveform
3.1.1 Radar Waveform Calibration Procedure
       The Interference Radar Detection Threshold Level is (-62dBm) + (0) [dBi]+ 1 dB= -61dBm that had
       been taken into account the output power range and antenna gain. The following equipment setup was
       used to calibrate the radiated Radar Waveform. A vector signal generator was utilized to establish the
       test signal level for radar type 0. During this process there were no transmissions by either the Master
       or Client Device. The spectrum analyzer was switched to the zero span (Time Domain) at the frequency
       of the Radar Waveform generator. Peak detection was used. The spectrum analyzer resolution
       bandwidth (RBW) and video bandwidth (VBW) were set to 3 MHz to measure the type 0 radar
       waveform. The spectrum analyzer had offset -8.26dB to compensate receiving horn antenna gain
       11.80dBi and RF cable loss 3.54dB. The vector signal generator amplitude was set so that the power
       level measured at the spectrum analyzer was (-62dBm) + (0) [dBi]+ 1 dB= -61 dBm. Capture the
       spectrum analyzer plots on short pulse radar waveform.


3.1.2 Radiated Calibration Setup




3.1.3 Calibration Deviation
       There is no deviation with the original standard.




Sporton International (Shenzhen) Inc.                                        Page Number        : 13 of 21
TEL : +86-755-86379589                                                       Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                       Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                      Report No. : FZ942205


3.1.4 Radar Waveform Calibration Result

                                    <80MHz / 5530 MHz> In-Service Monitoring

        Radar / DFS detection threshold level and the burst of pulses on the Channel frequency




Sporton International (Shenzhen) Inc.                                     Page Number        : 14 of 21
TEL : +86-755-86379589                                                    Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                    Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                     Report No. : FZ942205


3.2 In-Service Monitoring: Channel Move Time, Channel Closing
    Transmission Time and Non-Occupancy Period
3.2.1 Limit of In-Service Monitoring
      The EUT has In-Service Monitoring function to continuously monitor the radar signals, If radar is
detected, it must leave the channel (Shutdown). The Channel Move Time to cease all transmissions on the
current Channel upon detection of a Radar Waveform above the DFS Detection Threshold within 10 sec. The
total duration of Channel Closing Transmission Time is comprised of 200 milliseconds starting at the
beginning of the Channel Move Time plus any additional intermittent control signals required to facilitate
Channel changes (an aggregate of 60 milliseconds) during the remainder of the 10 second period. The
aggregate duration of control signals will not count quiet periods in between transmissions.
      Non-Occupancy Period time is 30 minute during which a Channel will not be utilized after a Radar
Waveform is detected on that Channel. The non-associated Client Beacon Test is during the 30 minutes
observation time. The EUT should not make any transmissions in the DFS band after EUT power up.




Sporton International (Shenzhen) Inc.                                    Page Number        : 15 of 21
TEL : +86-755-86379589                                                   Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                   Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


              FCC RF Test Report                                                           Report No. : FZ942205


3.2.2 Test Procedures


         1.    The radar pulse generator is setup to provide a pulse at frequency that the Master and Client are
               operating. A type 0 radar pulse with a 1us pulse width and a 1428 us PRI is used for the testing.
         2.    The vector signal generator is adjusted to provide the radar burst (18 pulses) at a level of
               approximately -62dBm at the antenna of the Master device.
         3.    A trigger is provided from the pulse generator to the DFS monitoring system in order to capture
               the traffic and the occurrence of the radar pulse.
         4.    A U-NII device operating as a Client Device will associate with the Master at Channel. The
               MPEG file “TestFile.mpg” specified by the FCC is streamed from the “file computer” through the
               Master to the Client Device and played in full motion video using Media Player Classic Ver.
               6.4.8.6 in order to properly load the network for the entire period of the test.
         5.    When a radar Burst with a level equal to the DFS Detection Threshold + 1dB is generated on the
               Operating Channel of the U-NII device. At time T0 the Radar Waveform generator sends a Burst
               of pulse of the radar waveform at Detection Threshold + 1dB.
         6.    Observe the transmissions of the EUT at the end of the radar Burst on the Operating Channel.
               Measure and record the transmissions from the EUT during the observation time (Channel Move
               Time). One 12 seconds plot is reported for the Short Pulse Radar Types 1. The plot for the Short
               Pulse Radar Types start at the end of the radar burst. The Channel Move Time will be calculated
               based on the zoom in 600ms plot of the Short Pulse Radar Type.
         7.    Measurement of the aggregate duration of the Channel Closing Transmission Time method.
               With the spectrum analyzer set to zero span tuned to the center frequency of the EUT operating
               channel at the radar simulated frequency, peak detection, and max hold, the dwell time per bin is
               given by: Dwell (0.4ms)= S (12000ms) / B (30000); where Dwell is the dwell time per spectrum
               analyzer sampling bin, S is the sweep time and B is the number of spectrum analyzer sampling
               bins. An upper bound of the aggregate duration of the intermittent control signals of Channel
               Closing Transmission Time is calculated by: C (ms)= N X Dwell (0.4 ms); where C is the Closing
               Time, N is the number of spectrum analyzer sampling bins (intermittent control signals) showing
               a U-NII transmission and Dwell is the dwell time per bin.
         8.    Measure the EUT for more than 30 minutes following the channel move time to verify that no
               transmissions or beacons occur on this Channel.




Sporton International (Shenzhen) Inc.                                            Page Number        : 16 of 21
TEL : +86-755-86379589                                                           Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                           Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                         Report No. : FZ942205


3.2.3 Test Setup
      Radiated Test Setup Photo




3.2.4 Test Deviation
         There is no deviation with the original standard.




Sporton International (Shenzhen) Inc.                        Page Number        : 17 of 21
TEL : +86-755-86379589                                       Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                       Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                            Report No. : FZ942205


3.2.5 Result of Channel Move Time, Channel Closing Transmission Time and
Non-Occupancy Period for Client Beacon Test
Test Mode :         Client without radar detection                 Temperature :              24.5℃
Test Engineer : Gao jian                                           Relative Humidity : 46%


   BW / Channel                         Test Item                 Test Result              Limit         Pass/Fail

                                   Channel Move Time               0.438815s              < 10s             Pass
                                                                    200ms +
 80MHz / 5530MHz         Channel Closing Transmission Time                              < 260ms             Pass
                                                                     2.4ms
                                 Non-Occupancy Period                    ≥ 30            ≥ 30 min           Pass
Note: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning of
the Channel Move Time plus any additional intermittent control signals required to facilitate a Channel move
(an aggregate of 60 milliseconds) during the remainder of the 10 seconds period. The aggregate duration of
control signals will not count quiet periods in between transmissions.




Sporton International (Shenzhen) Inc.                                           Page Number        : 18 of 21
TEL : +86-755-86379589                                                          Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                          Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                        Report No. : FZ942205


3.2.6 Channel Move Time, Channel Closing Transmission Time and Non-Occupancy
Period for Client Beacon Test Plots
                                        <80MHz / 5530 MHz> In-Service Monitoring
                                              Channel Move Time &
                                        Channel Closing Transmission Time




                                                                        Non-associated test
                Non-Occupancy Period
                                                                    Master was off. (beacon test)




Note:
Dwell (0.4 ms)= Sweep Time (12000 ms) / Sweep Point Bins (30000)
Channel Closing Transmission Time ( 200 + 2.4ms) = 200 + Number (6) X Dwell (0.4 ms) < 260ms




Sporton International (Shenzhen) Inc.                                       Page Number        : 19 of 21
TEL : +86-755-86379589                                                      Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                      Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


            FCC RF Test Report                                                      Report No. : FZ942205


3.2.7 Data Traffic and Noise Floor Plots
                EUT data traffic (Client)                      Access Point data traffic (Master)




                                        Noise Floor (No transmission)




Sporton International (Shenzhen) Inc.                                     Page Number        : 20 of 21
TEL : +86-755-86379589                                                    Report Issued Date : Jun. 10, 2019
FAX : +86-755-86379595                                                    Report Version     : Rev. 01
FCC ID : 2ABZ2-GM1925


                FCC RF Test Report                                                                    Report No. : FZ942205


  4 List of Measuring Equipment
                                                                           Calibration
Instrument      Manufacturer   Model No.    Serial No.   Characteristics                  Test Date      Due Date      Remark
                                                                              Date

   Signal                                                                                                              Conducted
                    R&S          FSV7        101473       10Hz~7GHz        Dec. 22, 2018 May 09, 2019 Dec. 21, 2019
  Analyzer                                                                                                            (DFS01-SZ)

 MXG-B RF
                                                                                                                       Conducted
Vector Signal     Keysight      N5182B     MY56200424     9kHz~6GHz        Dec. 22, 2018 May 09, 2019 Dec. 21, 2019
                                                                                                                      (DFS01-SZ)
 Generator
                  BEIJING      XB-WDB-                                                                                 Conducted
Horn Antenna                                 040504       1GHz~18GHz       Oct. 18, 2018 May 09, 2019 Oct. 17, 2019
                   XIBAO         1-18                                                                                 (DFS01-SZ)
                  BEIJING      XB-WDB-                                                                                 Conducted
Horn Antenna                                 040506       1GHz~18GHz       Oct. 18, 2018 May 09, 2019 Oct. 17, 2019
                   XIBAO         1-18                                                                                 (DFS01-SZ)




  Sporton International (Shenzhen) Inc.                                                  Page Number        : 21 of 21
  TEL : +86-755-86379589                                                                 Report Issued Date : Jun. 10, 2019
  FAX : +86-755-86379595                                                                 Report Version     : Rev. 01
  FCC ID : 2ABZ2-GM1925



Document Created: 2019-08-29 10:17:34
Document Modified: 2019-08-29 10:17:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC