RF Exposure Appendix B-2

FCC ID: 2ABZ2-GM1915

RF Exposure Info

Download: PDF
FCCID_4226405

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.02


49_GSMS850_GPRS(4 Tx slots)_Back_15mm_Ch251


Communication System: UID 0, GPRS/EDGE12 (0); Frequency: 848.8 MHz;Duty Cycle: 1:2.08
Medium: MSL_835_190202 Medium parameters used: £= 849 MHz; 0= 0.988 S/m; e,= 54.127; p=
1000 kg/m}
Ambient Temperature : 23.4 °C; Liquid Temperature : 22.6 °C

DASY 5 Configuration:
— Probe: EX3DV4 — SN3753; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.05.29;
— Sensor—Surface: 2mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
— Phantom: SAM2; Type: QDO0OP40CD: Serial: TP:1671
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch251/Area Scan (71x121x1): Interpolated grid: dx=1 Smm, dy=1 5mm
Maximum value of SAR (interpolated) = 0.788 W/kg

Ch251/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=4.120 V/m; Power Drift =—0.05 dB
Peak SAR (extrapolated) = 0.888 Wkg
SAR(1 g) = 0.457 W/kg; SAR(10 g) = 0.310 W/kg
Maximum value of SAR (measured) =0.740 W/kg

   dB
   0

    —2.14

    —5.49

    —8.23

    —10.98


    —13.72
               0 dB =0.740 Wikg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.30


50_GSM1900_GPRS(3 Tx slots)_Back_15mm_Ch661


Communication System: UID 0, GPRS/EDGE1 1 (0); Frequency: 1880 MHz;Duty Cycle: 1:2.77
Medium: MSL_1900_190130 Medium parameters used: £= 1880 MHz; a= 1.513 S/m; & = 54.609; p
=1000 kg/m®
Ambient Temperature : 23.5 °C; Liquid Temperature : 22.4 °C

DASY 5 Configuration:
— Probe: EX3DV4 — SN3753; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.05.29;
— Sensor—Surface: 2mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
— Phantom: SAM2; Type: QDO0OP40CD: Serial: TP:1671
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch661/Area Scan (71x121x1): Interpolated grid: dx=1 Smm, dy=1 5mm
Maximum value of SAR (interpolated) = 0.295 W/kg

Ch661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=4.195 V/m; Power Drift =—0.09 dB
Peak SAR (extrapolated) = 0.357 Wkg
SAR(1 g) = 0.224 W/kg; SAR(10 g) = 0.138 W/kg
Maximum value of SAR (measured) =0.291 W/kg




    —3.21

    —6.42

    —9.63

    —12.84


    —16.05
               0 dB =0.291 Wikg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.02

51_WCDMA V_RMC 12.2Kbps_Back_15mm_Ch4132



Communication System: UID 0, UMTS (0); Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: MSL_835_190202 Medium parameters used: f = 826.4 MHz; σ = 0.966 S/m; εr = 54.313; ρ
= 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch4132/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.563 W/kg

Ch4132/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 2.133 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 0.665 W/kg
SAR(1 g) = 0.448 W/kg; SAR(10 g) = 0.290 W/kg
Maximum value of SAR (measured) = 0.565 W/kg




               0 dB = 0.565 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.31

52_WCDMA IV_RMC 12.2Kbps_Back_15mm_Ch1312



Communication System: UID 0, UMTS (0); Frequency: 1712.4 MHz;Duty Cycle: 1:1
Medium: MSL_1750_190131 Medium parameters used: f = 1712.4 MHz; σ = 1.47 S/m; εr = 52.06; ρ
= 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.7 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(7.76, 7.76, 7.76); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch1312/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.512 W/kg

Ch1312/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 5.559 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 0.590 W/kg
SAR(1 g) = 0.406 W/kg; SAR(10 g) = 0.275 W/kg
Maximum value of SAR (measured) = 0.494 W/kg




               0 dB = 0.494 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.30

53_WCDMA II_RMC 12.2Kbps_Back_15mm_Ch9262



Communication System: UID 0, UMTS (0); Frequency: 1852.4 MHz;Duty Cycle: 1:1
Medium: MSL_1900_190130 Medium parameters used: f = 1852.4 MHz; σ = 1.475 S/m; εr = 54.674;
ρ = 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch9262/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.701 W/kg

Ch9262/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 6.128 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 0.817 W/kg
SAR(1 g) = 0.492 W/kg; SAR(10 g) = 0.296 W/kg
Maximum value of SAR (measured) = 0.644 W/kg




               0 dB = 0.644 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.02

54_CDMA2000 BC0_RC3 SO32 (F+SCH)_Back_15mm_Ch384



Communication System: UID 0, CDMA2000 (0); Frequency: 836.52 MHz;Duty Cycle: 1:1
Medium: MSL_835_190202 Medium parameters used: f = 837 MHz; σ = 0.976 S/m; εr = 54.233; ρ =
1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch384/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.682 W/kg

Ch384/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 2.200 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 0.794 W/kg
SAR(1 g) = 0.527 W/kg; SAR(10 g) = 0.338 W/kg
Maximum value of SAR (measured) = 0.669 W/kg




               0 dB = 0.669 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.30

55_CDMA2000 BC1_RC3 SO32 (F+SCH) _Back_15mm_Ch600



Communication System: UID 0, CDMA2000 (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: MSL_1900_190130 Medium parameters used: f = 1880 MHz; σ = 1.513 S/m; εr = 54.609; ρ
= 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch600/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.595 W/kg

Ch600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 5.175 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 0.697 W/kg
SAR(1 g) = 0.463 W/kg; SAR(10 g) = 0.302 W/kg
Maximum value of SAR (measured) = 0.585 W/kg




               0 dB = 0.585 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.01

56_LTE Band 71_20M_QPSK_1RB_0Offset_Back_15mm_Ch133322



Communication System: UID 0, LTE (0); Frequency: 683 MHz;Duty Cycle: 1:1
Medium: MSL_750_190201 Medium parameters used: f = 683 MHz; σ = 0.91 S/m; εr = 55.617; ρ =
1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(9.58, 9.58, 9.58); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch133322/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.394 W/kg

Ch133322/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 1.487 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.452 W/kg
SAR(1 g) = 0.314 W/kg; SAR(10 g) = 0.210 W/kg
Maximum value of SAR (measured) = 0.389 W/kg




               0 dB = 0.389 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.01

57_LTE Band 12_10M_QPSK_1RB_49Offset_Back_15mm_Ch23095



Communication System: UID 0, LTE (0); Frequency: 707.5 MHz;Duty Cycle: 1:1
Medium: MSL_750_190201 Medium parameters used: f = 707.5 MHz; σ = 0.933 S/m; εr = 55.184; ρ
= 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(9.58, 9.58, 9.58); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch23095/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.541 W/kg

Ch23095/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 1.871 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 0.627 W/kg
SAR(1 g) = 0.434 W/kg; SAR(10 g) = 0.288 W/kg
Maximum value of SAR (measured) = 0.538 W/kg




               0 dB = 0.538 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.01

58_LTE Band 13_10M_QPSK1RB_25Offset_Back_15mm_Ch23230



Communication System: UID 0, LTE (0); Frequency: 782 MHz;Duty Cycle: 1:1
Medium: MSL_750_190201 Medium parameters used: f = 782 MHz; σ = 0.988 S/m; εr = 53.552; ρ =
1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(9.58, 9.58, 9.58); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch23230/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.590 W/kg

Ch23230/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 1.662 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 0.694 W/kg
SAR(1 g) = 0.471 W/kg; SAR(10 g) = 0.309 W/kg
Maximum value of SAR (measured) = 0.593 W/kg




               0 dB = 0.593 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.02

59_LTE Band 5_10M_QPSK_1RB_0Offset_Back_15mm_Ch20525



Communication System: UID 0, LTE (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium: MSL_835_190202 Medium parameters used: f = 836.5 MHz; σ = 0.976 S/m; εr = 54.24; ρ =
1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20525/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.627 W/kg

Ch20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 1.871 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 0.714 W/kg
SAR(1 g) = 0.479 W/kg; SAR(10 g) = 0.311 W/kg
Maximum value of SAR (measured) = 0.606 W/kg




               0 dB = 0.606 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.02

60_LTE Band 26_15M_QPSK_1RB_0Offset_Back_15mm_Ch26965



Communication System: UID 0, LTE (0); Frequency: 841.5 MHz;Duty Cycle: 1:1
Medium: MSL_835_190202 Medium parameters used: f = 841.5 MHz; σ = 0.98 S/m; εr = 54.194; ρ =
1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch26965/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.532 W/kg

Ch26965/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 1.677 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 0.603 W/kg
SAR(1 g) = 0.405 W/kg; SAR(10 g) = 0.262 W/kg
Maximum value of SAR (measured) = 0.514 W/kg




               0 dB = 0.514 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.31

61_LTE Band 66_20M_QPSK_1RB_0Offset_Back_15mm_Ch132322



Communication System: UID 0, LTE (0); Frequency: 1745 MHz;Duty Cycle: 1:1
Medium: MSL_1750_190131 Medium parameters used: f = 1745 MHz; σ = 1.506 S/m; εr = 52.003; ρ
= 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.7 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(7.76, 7.76, 7.76); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch132322/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.524 W/kg

Ch132322/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 5.216 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 0.617 W/kg
SAR(1 g) = 0.417 W/kg; SAR(10 g) = 0.276 W/kg
Maximum value of SAR (measured) = 0.522 W/kg




               0 dB = 0.522 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.30

62_LTE Band 25_20M_QPSK_1RB_0Offset_Back_15mm_Ch26140



Communication System: UID 0, LTE (0); Frequency: 1860 MHz;Duty Cycle: 1:1
Medium: MSL_1900_190130 Medium parameters used: f = 1860 MHz; σ = 1.486 S/m; εr = 54.647; ρ
= 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch26140/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.580 W/kg

Ch26140/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 3.174 V/m; Power Drift = -0.17 dB
Peak SAR (extrapolated) = 0.685 W/kg
SAR(1 g) = 0.401 W/kg; SAR(10 g) = 0.246 W/kg
Maximum value of SAR (measured) = 0.526 W/kg




               0 dB = 0.526 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.30

63_LTE Band 2_20M_QPSK_1RB_0Offset_Back_15mm_Ch18900



Communication System: UID 0, LTE (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: MSL_1900_190130 Medium parameters used: f = 1880 MHz; σ = 1.513 S/m; εr = 54.609; ρ
= 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch18900/Area Scan (71x121x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.598 W/kg

Ch18900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 4.683 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 0.753 W/kg
SAR(1 g) = 0.432 W/kg; SAR(10 g) = 0.245 W/kg
Maximum value of SAR (measured) = 0.578 W/kg




               0 dB = 0.578 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.23


64_LTE Band 30_10M_QPSK_1RB_0Offset_Back_15mm_Ch27710


Communication System: UID 0, LTE (0); Frequency: 2310 MHz;Duty Cycle: 1:1
Medium: MSL_2300_190223 Medium parameters used: £= 2310 MHz; 0= 1.773 S/m; e = 53.718; p
=1000 kg/m®
Ambient Temperature : 23.5 °C; Liquid Temperature : 22.9 °C

DASY 5 Configuration:
— Probe: EX3DV4 — SN3935; ConvF(7.86, 7.86, 7.86); Calibrated: 2018.11.26;
— Sensor—Surface: 2mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn715; Calibrated: 2019.01.23
— Phantom: SAM (Front) with CRP v5.0; Type: QDO0OP40CD; Serial: TP: 1795
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch27710/Area Sean (01x161x1): Interpolated grid: dx=12mm, dy=12mm
Maximum value of SAR (interpolated) = 0.362 W/kg

Ch27710/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=mm, da=5mm
Reference Value=2.971 V/m; Power Drift =—0.16 dB
Peak SAR (extrapolated) = 0.468 Wikg
SAR(1 g) = 0.254 W/kg; SAR(10 g) = 0.138 W/kg
Maximum value of SAR (measured) = 0.358 W/kg




    ~4.27

    —8.55

    —12.02

    —17.10


    —21.37
               0 dB =0.358 Wikg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.03


65_LTE Band 7_20M_QPSK_1RB_990ffset_Back_15mm_Ch20850


Communication System: UID 0, LTE (0); Frequency: 2510 MHz;Duty Cycle: 1:1
Medium: MSL_2600_190203 Medium parameters used: £= 2510 MHz; a= 2.075 S/m; & = 51.267;
P= 1000 kg/m>
Ambient Temperature : 23.6 °C; Liquid Temperature : 22.8 °C

DASY 5 Configuration:
— Probe: EX3DV4 — SN3935; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.11.26;
— Sensor—Surface: 2mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn715; Calibrated: 2019.01.23
— Phantom: SAM (Front) with CRP v5.0; Type: QDO0OP40CD; Serial: TP: 1795
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20850/Area Sean (01x161x1): Interpolated grid: dx=12mm, dy=12mm
Maximum value of SAR (interpolated) = 0.386 W/kg

Ch20850/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=mm, da=5mm
Reference Value=3.030 V/m; Power Drift =—0.02 dB
Peak SAR (extrapolated) = 0.518 Wkg
SAR(1 g) = 0.272 W/kg; SAR(10 g) = 0.147 W/kg
Maximum value of SAR (measured) =0.389 W/kg




    —4.48

    —8.96

    —13.45

    —17.93


    —22.41
               0 dB =0.389 Wikg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.20


66_LTE Band 41_20M_QPSK_1RB_49Offset_Back_15mm_Ch40620


Communication System: UID 0, LTE (0); Frequency: 2593 MHz;Duty Cycle: 1:2.331
Medium: MSL_2600_190220 Medium parameters used: £= 2593 MHz; a= 2.173 S/m; & = 50.754; p
=1000 kg/m®
Ambient Temperature : 23.6 °C; Liquid Temperature : 22.8 °C

DASY 5 Configuration:
— Probe: EX3DV4 — SN3935; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.11.26;
— Sensor—Surface: 2mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
— Phantom: SAM (Front) with CRP v5.0; Type: QDO0OP40CD; Serial: TP: 1795
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch40620/Area Sean (01x161x1): Interpolated grid: dx=12mm, dy=12mm
Maximum value of SAR (interpolated) = 0.320 W/kg

Ch40620/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=mm, daz=5mm
Reference Value=3.975 V/m; Power Drift =—0.06 dB
Peak SAR (extrapolated) = 0.472 Wikg
SAR(1 g) = 0.215 W/kg; SAR(10 g) = 0.101 W/kg
Maximum value of SAR (measured) =0.335 W/kg




    5.15

    —10.30

    —15.44

    —20.59


    —25.14
               0 dB =0.335 Wikg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.28

67_LTE Band 48_20M_QPSK_1RB_0Offset_Front_15mm_Ch56150


Communication System: UID 0, LTE (0); Frequency: 3641 MHz;Duty Cycle: 1:1
Medium: MSL_3500-3700_190228 Medium parameters used: f = 3641 MHz; σ = 3.47 S/m; εr =
50.459; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3857; ConvF(6.71, 6.71, 6.71); Calibrated: 2018.05.31;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch56150/Area Scan (91x191x1): Interpolated grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 0.548 W/kg

Ch56150/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 0.8670 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.740 W/kg
SAR(1 g) = 0.311 W/kg; SAR(10 g) = 0.133 W/kg
Maximum value of SAR (measured) = 0.559 W/kg




               0 dB = 0.559 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.24

68_WLAN2.4GHz_802.11b 1Mbps_Back_15mm_Ch6


Communication System: UID 0, WIFI (0); Frequency: 2437 MHz;Duty Cycle: 1:1.008
Medium: MSL_2450_180224 Medium parameters used: f = 2437 MHz; σ = 2.024 S/m; εr = 51.922;
ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3911; ConvF(7.54, 7.54, 7.54); Calibrated: 2019.01.22;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch6/Area Scan (81x151x1): Interpolated grid: dx=12mm, dy=12mm
Maximum value of SAR (interpolated) = 0.281 W/kg

Ch6/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 6.409 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 0.365 W/kg
SAR(1 g) = 0.200 W/kg; SAR(10 g) = 0.110 W/kg
Maximum value of SAR (measured) = 0.280 W/kg




               0 dB = 0.280 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.25

69_WLAN5GHz_802.11a_6Mbps_Back_15mm_Ch52


Communication System: UID 0, WIFI (0); Frequency: 5260 MHz;Duty Cycle: 1:1.022
Medium: MSL_5250_190225 Medium parameters used: f = 5260 MHz; σ = 5.399 S/m; εr = 46.875;
ρ = 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.9 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3911; ConvF(4.67, 4.67, 4.67); Calibrated: 2019.01.22;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch52/Area Scan (91x181x1): Interpolated grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 1.25 W/kg

Ch52/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 0 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 2.03 W/kg
SAR(1 g) = 0.539 W/kg; SAR(10 g) = 0.178 W/kg
Maximum value of SAR (measured) = 1.26 W/kg




               0 dB = 1.26 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.25

70_WLAN5GHz_802.11a_6Mbps_Back_15mm_Ch132


Communication System: UID 0, WIFI (0); Frequency: 5660 MHz;Duty Cycle: 1:1.022
Medium: MSL_5600_190225 Medium parameters used: f = 5660 MHz; σ = 5.917 S/m; εr = 46.174;
ρ = 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.9 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3911; ConvF(4.04, 4.04, 4.04); Calibrated: 2019.01.22;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch132/Area Scan (91x181x1): Interpolated grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 0.878 W/kg

Ch132/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 0.7900 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 1.70 W/kg
SAR(1 g) = 0.407 W/kg; SAR(10 g) = 0.162 W/kg
Maximum value of SAR (measured) = 0.956 W/kg




               0 dB = 0.956 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.25

71_WLAN5GHz_802.11a_6Mbps_Back_15mm_Ch157


Communication System: UID 0, WIFI (0); Frequency: 5785 MHz;Duty Cycle: 1:1.022
Medium: MSL_5750_190225 Medium parameters used: f = 5785 MHz; σ = 6.086 S/m; εr = 45.962;
ρ = 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3911; ConvF(4.16, 4.16, 4.16); Calibrated: 2019.01.22;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch157/Area Scan (91x181x1): Interpolated grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 0.744 W/kg

Ch157/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 0.7000 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 1.48 W/kg
SAR(1 g) = 0.329 W/kg; SAR(10 g) = 0.113 W/kg
Maximum value of SAR (measured) = 0.819 W/kg




               0 dB = 0.819 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.24


72_Bluetooth_DHS 1Mbps_Back_15mm_Ch39



Communication System: UID 0, Bluetooth (0); Frequency: 2441 MHz;Duty Cycle: 1:1.302
Medium: MSL_2450_180224 Medium parameters used: £=2441 MHz; a = 2.029 S/m; e = 51.905;
p = 1000 kg/m?
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.6 °C

DASY3 Configuration:
— Probe: EX3DV4 — SN3911; ConvF(7.54, 7.54,7.54); Calibrated: 2019.01.22;
— Sensor—Surface: 2mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn715; Calibrated: 2019.01.23
— Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch39/Area Scan (81x151x1): Interpolated grid: dx=12mm, dy=12mm
Maximum value of SAR (interpolated) = 0.0271 W/kg

Ch39/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=Smm, dy=5mm, dz=5mm
Reference Value = 0.8350 V/m; Power Drift= 0.07 dB
Peak SAR (extrapolated) =0.0270 W/kg
SAR( g) = 0.014 W/kg; SAR(10 g) = 0.00704 W/kg
Maximum value of SAR (measured)= 0.0202 W/kg




    —10.00

    —20.00

    —30.00

    ~40.00

    —50.00
               0 dB =0.0202 Wkg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.22

73_WCDMA IV_RMC 12.2Kbps_Bottom Side_0mm_Ch1513


Communication System: UID 0, UMTS (0); Frequency: 1752.6 MHz;Duty Cycle: 1:1
Medium: MSL_1750_190222 Medium parameters used: f = 1753 MHz; σ = 1.528 S/m; εr = 52.273;
ρ = 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.7 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3935; ConvF(8.45, 8.45, 8.45); Calibrated: 2018.11.26;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch1513/Area Scan (41x81x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 8.59 W/kg

Ch1513/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 3.091 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 12.8 W/kg
SAR(1 g) = 5.71 W/kg; SAR(10 g) = 2.65 W/kg
Maximum value of SAR (measured) = 9.63 W/kg




               0 dB = 9.63 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.21


74_WCDMA II_RMC 12.2Kbps_Bottom Side_Omm_Ch9538


Communication System: UID 0, UMTS (0); Frequency: 1907.6 MHz;Duty Cycle: 1:1
Medium: MSL_1900_190221 Medium parameters used: £= 1908 MHz; a= 1.571 S/m; s = 55.2; p
=1000 kg/m>
Ambient Temperature : 23.7 °C; Liquid Temperature : 22.7 °C

DASY3 Configuration:
— Probe: EX3DV4 — SN3935; ConvF(8.07, 8.07, 8.07); Calibrated: 2018.11.26;
— Sensor—Surface: 2mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn715; Calibrated: 2019.01.23
— Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch9538/Area Scan (41x81x1): Interpolated grid: dx=1 5mm, dy=15mm
Maximum value of SAR (interpolated) =7.45 W/kzg

Ch9538/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=2.318 V/m; Power Drift= 0.04 dB
Peak SAR (extrapolated) =11.0 W/kg
SAR( g) = 5.04 W/kg:; SAR(10 g) = 2.36 W/kg
Maximum value of SAR (measured)= 8.45 W/kg

   dB
   0

    ~4.59

    —9.18

    —13.76

    ~18.35

    —22.94
               0 dB =8.45 We


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.21

75_CDMA2000 BC1_RTAP 153.6Kbps_Back_0mm_Ch1175


Communication System: UID 0, CDMA2000 (0); Frequency: 1908.75 MHz;Duty Cycle: 1:1
Medium: MSL_1900_190221 Medium parameters used: f = 1909 MHz; σ = 1.573 S/m; εr = 55.197;
ρ = 1000 kg/m3
Ambient Temperature:23.7 ℃; Liquid Temperature:22.7 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3935; ConvF(8.07, 8.07, 8.07); Calibrated: 2018.11.26;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch1175/Area Scan (71x131x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 8.67 W/kg

Ch1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 0.9830 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 15.3 W/kg
SAR(1 g) = 6.1 W/kg; SAR(10 g) = 2.72 W/kg
Maximum value of SAR (measured) = 9.30 W/kg




               0 dB = 9.30 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.31

76_LTE Band 66_20M_QPSK_50RB_24Offset_Bottom Side_0mm_Ch132322



Communication System: UID 0, LTE (0); Frequency: 1745 MHz;Duty Cycle: 1:1
Medium: MSL_1750_190131 Medium parameters used: f = 1745 MHz; σ = 1.506 S/m; εr = 52.003; ρ
= 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.7 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(7.76, 7.76, 7.76); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch132322/Area Scan (41x81x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 8.00 W/kg

Ch132322/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 2.480 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 23.4 W/kg
SAR(1 g) = 6.36 W/kg; SAR(10 g) = 2.69 W/kg
Maximum value of SAR (measured) = 13.1 W/kg




               0 dB = 13.1 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.01.30

77_LTE Band 25_20M_QPSK_50RB_24Offset_Bottom Side_0mm_Ch26140



Communication System: UID 0, LTE (0); Frequency: 1860 MHz;Duty Cycle: 1:1
Medium: MSL_1900_190130 Medium parameters used: f = 1860 MHz; σ = 1.486 S/m; εr = 54.647; ρ
= 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3753; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.05.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1437; Calibrated: 2018.10.15
- Phantom: SAM2; Type: QD000P40CD; Serial: TP:1671
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch26140/Area Scan (41x81x1): Interpolated grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 8.62 W/kg

Ch26140/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 2.896 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 27.5 W/kg
SAR(1 g) = 6.07 W/kg; SAR(10 g) = 2.67 W/kg
Maximum value of SAR (measured) = 16.0 W/kg




               0 dB = 16.0 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.20

78_LTE Band 7_20M_QPSK_1RB_99Offset_Bottom Side_10mm_Ch20850


Communication System: UID 0, LTE (0); Frequency: 2510 MHz;Duty Cycle: 1:1
Medium: MSL_2600_190220 Medium parameters used: f = 2510 MHz; σ = 2.075 S/m; εr = 51.267;
ρ = 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.8 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3935; ConvF(7.52, 7.52, 7.52); Calibrated: 2018.11.26;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20850/Area Scan (41x91x1): Interpolated grid: dx=12mm, dy=12mm
Maximum value of SAR (interpolated) = 9.49 W/kg

Ch20850/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 56.72 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 16.8 W/kg
SAR(1 g) = 5.68 W/kg; SAR(10 g) = 1.86 W/kg
Maximum value of SAR (measured) = 10.6 W/kg

Ch20850/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 56.72 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 13.9 W/kg
SAR(1 g) = 4.02 W/kg; SAR(10 g) = 1.6 W/kg
Maximum value of SAR (measured) = 8.79 W/kg




               0 dB = 9.49 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.25

79_WLAN5GHz_802.11a_6Mbps_Back_0mm_Ch52


Communication System: UID 0, WIFI (0); Frequency: 5260 MHz;Duty Cycle: 1:1.022
Medium: MSL_5250_190225 Medium parameters used: f = 5260 MHz; σ = 5.399 S/m; εr = 46.875;
ρ = 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.9 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3911; ConvF(4.67, 4.67, 4.67); Calibrated: 2019.01.22;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch52/Area Scan (91x181x1): Interpolated grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 31.8 W/kg

Ch52/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 0 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 82.9 W/kg
SAR(1 g) = 11.5 W/kg; SAR(10 g) = 2.2 W/kg
Maximum value of SAR (measured) = 37.5 W/kg




               0 dB = 31.8 W/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.02.25

80_WLAN5GHz_802.11a_6Mbps_Back_0mm_Ch100


Communication System: UID 0, WIFI (0); Frequency: 5500 MHz;Duty Cycle: 1:1.022
Medium: MSL_5600_190225 Medium parameters used: f = 5500 MHz; σ = 5.694 S/m; εr = 46.439;
ρ = 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.8 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3911; ConvF(4.04, 4.04, 4.04); Calibrated: 2019.01.22;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn715; Calibrated: 2019.01.23
- Phantom: SAM (Front) with CRP v5.0; Type: QD000P40CD; Serial: TP:1795
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch100/Area Scan (91x181x1): Interpolated grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 13.8 W/kg

Ch100/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 0 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 42.8 W/kg
SAR(1 g) = 6.52 W/kg; SAR(10 g) = 1.52 W/kg
Maximum value of SAR (measured) = 22.6 W/kg

Ch100/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 0 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 33.2 W/kg
SAR(1 g) = 5.82 W/kg; SAR(10 g) = 1.21 W/kg
Maximum value of SAR (measured) = 18.0 W/kg




               0 dB = 13.8 W/kg