RF Test Report -CDMA

FCC ID: 2ABZ2-A3000

Test Report

Download: PDF
FCCID_3202539

                                  TEST REPORT

                             No.I16N00975-EMC02
                                                       for

                      OnePlus Technology(Shenzhen) Co., Ltd.

                                              Mobile Phone

                               Model Name: ONEPLUS A3000

                                       FCC ID: 2ABZ2-A3000

                                                      with

                                       Hardware Version: 28

                               Software Version: oxygen 3.5.1

                                     Issued Date: 2016-10-31
Test Laboratory:
FCC 2.948 Listed: No.342690
Note:
The test results in this test report relate only to the devices specified in this report. This report shall not be
reproduced except in full without the written approval of CTTL.
Test Laboratory:
CTTL, Telecommunication Technology Labs, Academy of Telecommunication Research, MIIT
No.52, HuayuanNorth Road, Haidian District, Beijing, P. R. China 100191.
Tel:+86(0)10-62304633, Fax:+86(0)10-62304633Email:cttl@chinattl.com, website:www.chinattl.com




                                                                         ©Copyright. All rights reserved by CTTL.


                                               No.I16N00975-EMC02
                                                      Page 2 of 15


REPORT HISTORY
Report Number     Revision   Description                Issue Date
I16N00975-EMC02   Rev.0      1st edition                2016-10-31




                                           ©Copyright. All rights reserved by CTTL.


                                                                                                          No.I16N00975-EMC02
                                                                                                                 Page 3 of 15

CONTENTS
1.     TEST LABORATORY ..............................................................................................................................4
1.1.      TESTING LOCATION .........................................................................................................................4
1.2.      TESTING ENVIRONMENT ................................................................................................................4
1.3.      PROJECT DATA ...................................................................................................................................4
1.4.      SIGNATURE ..........................................................................................................................................4
2.     CLIENT INFORMATION ........................................................................................................................5
2.1.      APPLICANT INFORMATION ............................................................................................................5
2.2.      MANUFACTURER INFORMATION .................................................................................................5
3.     EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ..................................6
3.1.      ABOUT EUT ..........................................................................................................................................6
3.2.      INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST..........................................6
3.3.      INTERNAL IDENTIFICATION OF AE USED DURING THE TEST ............................................6
3.4.      GENERAL DESCRIPTION .................................................................................................................7
3.5.      EUT SET-UPS ........................................................................................................................................7
4.     REFERENCE DOCUMENTS ..................................................................................................................8
4.1.      REFERENCE DOCUMENTS FOR TESTING ..................................................................................8
5.     LABORATORY ENVIRONMENT..........................................................................................................9
6.     SUMMARY OF TEST RESULTS ..........................................................................................................10
6.1.      SUMMARY OF TEST RESULTS ......................................................................................................10
7. TEST EQUIPMENTS UTILIZED ............................................................................................................. 11
   A.1   EMISSION LIMT............................................................................................................................12
ANNEX B: TEST LAYOUT .............................................................................................................................15




                                                                                                       ©Copyright. All rights reserved by CTTL.


                                                                     No. 1 6N00975—EMCO2
                                                                              Page 4 of 15


1. Test Laboratory
1.1. Testing Location
  Address:                    TCL International E city No. 1001 Zhongshanyuan Road, Nanshan
                              District, Shenzhen, Guangdong, China
  Postal Code:                518048
  Telephone:                  +86(755)33322000
  Fax:                        +86(755)33322001


1.2. Testing Environment
  Normal Temperature:          15—35°C
  Relative Humidity:           20—75%


1.3. Project data
  Testing Start Date:         2016—08—31
  Testing End Date:           2016—10—29


1.4.   Signature




                     Liang Yong
             (Prepared this test report)



                     iO _A
                _ZL_ufin"\;‘umhuin C
          (Reviewed this test report)




               4).
                      Cao Junfei
              Director of the laboratory
          (Approved this test report)




                                                              ©Copyright. All rights reserved by CTTL


                                                          No.I16N00975-EMC02
                                                                 Page 5 of 15


2. Client Information
2.1. Applicant Information
 Company Name:       OnePlus Technology(Shenzhen) Co., Ltd.
 Address:            18/F, Tower C, Tai Ran Building,No.8 Tai Ran Road, Shenzhen, China


2.2. Manufacturer Information
 Company Name:       OnePlus Technology(Shenzhen) Co., Ltd.
 Address:            18/F, Tower C, Tai Ran Building,No.8 Tai Ran Road, Shenzhen, China




                                                      ©Copyright. All rights reserved by CTTL.


                                                                          No.I16N00975-EMC02
                                                                                 Page 6 of 15


3. Equipment Under Test (EUT) and Ancillary Equipment (AE)
3.1. About EUT
  Description                    Mobile Phone
  Model Name                     ONEPLUS A3000
  FCC ID                         2ABZ2-A3000
Remark: The above EUT’s information is declared by manufacturer. Please refer to the
specifications or user’s manual for more detailed information.


3.2. Internal Identification of EUT used during the test

  EUT ID*     SN or IMEI
  EUT          860046039212719
*EUT ID: is used to identify the test sample in the lab internally.


3.3. Internal Identification of AE used during the test

  AE ID*        Description                                  SN
  AE1           Battery                                      /
  AE2           Travel charger                               /
  AE3           USB cable                                    /
AE1
  Model                                BLP633
  Manufacturer                         DESAY
  Capacitance                          3400mAh
  Nominal Voltage                      3.85V
AE2-1
  Model                                HK0504
  Manufacturer                         SHENZHEN HUNTKEY ELECTRIC CO., LTD
  SN                                   HC1608500001
AE2-2
  Model                                DC0504A5
  Manufacturer                         SHENZHEN HUNTKEY ELECTRIC CO., LTD
  SN                                   H11619000004
AE2-3
  Model                                DC0504B5GB
  Manufacturer                         LITEON TECHNOLOGY CORPORATION
  SN                                   LCYYWWWSSSSSS
AE3
  Model                                /
  Manufacturer                         /
  Length of cable                      102cm
*AE ID: is used to identify the test sample in the lab internally.


                                                                      ©Copyright. All rights reserved by CTTL.


                                                             No.I16N00975-EMC02
                                                                    Page 7 of 15


3.4. General Description
Equipment Under Test (EUT) is a model of Mobile Phone with integrated antenna. It supports
GSM 850/1900;UMTS FDD Band II(W1900)/IV(W1700)/Band V(W850); CDMA Band 0;LTE Band
2/4/5/7/12/17/30/41
It has FM, Camera, MP3, USB, WiFi, Bluetooth, GPS;
Samples undergoing test were selected by the Client.


3.5. EUT set-ups

 EUT set-up No.           Combination of EUT and AE                 Remarks
 Set.1                    EUT+ AE1                                   ERP/EIRP/RSE tests




                                                         ©Copyright. All rights reserved by CTTL.


                                                                      No.I16N00975-EMC02
                                                                             Page 8 of 15


4. Reference Documents

4.1. Reference Documents for testing
The following documents listed in this section are referred for testing.
       Reference                                      Title                                  Version
                                                                                            10-1-2015
      FCC Part 22                        PUBLIC MOBILE SERVICES
                                                                                             Edition
                           Methods of Measurement of Radio-Noise Emissions from
      ANSI C63.4            Low-Voltage Electrical and Electronic Equipment in the             2014
                                         Range of 9 kHz to 40 GHz
                             Land Mobile FM or PM Communications Equipment
    ANSI/TIA-603-D                                                                             2010
                                 Measurement and Performance Standards




                                                                 ©Copyright. All rights reserved by CTTL.


                                                                         No.16N00975—EMCO2
                                                                                     Page 9 of 15



5. LABORATORY ENVIRONMENT
Semi—anechoic chamber did not exceed following limits along the EMC testing:
Temperature                                 Min. = 15 °C, Max.=30 °C
Relative humidity                           Min. = 35 %, Max. = 60 %

Shielding effectiveness                     0.014MHz—1IMHz,>60dB;
                                            1MHz—18000MHz,>90dB
Electrical insulation                       > 2MQ
Ground system resistance                    <4 Q
Normalised site attenuation (NSA)           < +4 dB, 3 m distance, from 30 to 1000 MHz
Shield room did not exceed following limits along the EMC testing:
Temperature                                 Min. = 15 °C, Max.=30 °C
Relative humidity                           Min. =35 %, Max. = 60 %
Shielding effectiveness                     0.014MHz—1MHz,>60dB;
                                            1MHz—10000MHz,>90dB
Electrical insulation                       > 2MQ
Ground system resistance                    <4 Q
Fully—anechoic chamber did not exceed following limits along the EMC testing:
Temperature                                 Min. = 15 °C, Max.=30 °C
Relative humidity                           Min. = 35 %, Max. = 60 %

Shielding effectiveness                     0.014MHz—1MHz,>60dB;
                                            1MHz—18000MHz,>90dB
Electrical insulation                       > 2MQ
Ground system resistance                    <4 Q
Voltage Standing Wave Ratio    (VSWR)       < 6 dB, from 1 to 18 GHz, 3 m distance
Uniformity of field strength                Between 0 and 6 dB, from 80 to 3000 MHz




                                                                     ©Copyright. All rights reserved by CTTL


                                                                 No.I16N00975-EMC02
                                                                       Page 10 of 15


6. SUMMARY OF TEST RESULTS
6.1. Summary of test results

     Abbreviations used in this clause:
                                P          Pass
                                F          Fail
      Verdict Column
                                NA         Not applicable
                                NM         Not measured


7.
     CDMA800
                                          Clause in         Section in
      Items         Test Name                                              Verdict
                                          FCC rules         this report
        1      Emission Limit         22.917(a), 2.1051        5.5            P




                                                             ©Copyright. All rights reserved by CTTL.


                                                              No.I16N00975-EMC02
                                                                    Page 11 of 15


       7. Test Equipments Utilized
                                                          SERIES             CAL. DUE           CAL.
NO.        NAME               TYPE        PRODUCER
                                                          NUMBER               DATE     INTERVAL
  1.      Test Receiver         ESCI          R&S           100702           2017-06-26   1 Years
  2.      BiLog Antenna       VULB9163    Schwarzbeck       9163 330         2017-04-22        3Years
  3.        Horn Antenna         3117       ETS-Lindgre      00066577         2019-04-05        3 Years
  5. Fully Anechoic Chamber   FACT5-2.0          n
                                          ETS-Lindgren        4166           2018-05-13         3Year
  6.   Spectrum Analyzer       FSP40         R&S             100378          2016-12-18         1 Year
         Universal Radio
  7.                          CMU200         R&S             114540          2016-12-24         1 Year
       Communication Tester




                                                          ©Copyright. All rights reserved by CTTL.


                                                                  No.I16N00975-EMC02
                                                                        Page 12 of 15

ANNEX A: MEASUREMENT RESULTS

A.1 EMISSION LIMT

Reference
FCC: CFR 2.1051, Part 22.917(a),

A.2.1 Measurement Method
The measurements procedures in TIA-603-D-2010 are used. This measurement is carried out in
fully-anechoic chamber 3.
The spectrum was scanned from 30 MHz to the 10th harmonic of the highest frequency generated
within the equipment, which is the transmitted carrier that can be as high as 1910 MHz. The
resolution bandwidth is set 1MHz as outlined in Part 22.917(a). The spectrum was scanned with the
mobile station transmitting at carrier frequencies that pertain to low, mid and high channels of
CDMA800 .

The procedure of radiated spurious emissions is as follows:
1. EUT was placed on a 1.5 meter high non-conductive stand at a 3 meter test distance from the
   receive antenna. A receiving antenna was placed on the antenna mast 3 meters from the EUT
   for emission measurements. The height of receiving antenna is 1.5m. The test setup refers to
   figure below. Detected emissions were maximized at each frequency by rotating the EUT
   through 360°and adjusting the receiving antenna polarization. The radiated emission
   measurements of all non-harmonic and harmonics of the transmit frequency through the 10th
   harmonic were measured with peak detector.




2. The EUT is then put into continuously transmitting mode at its maximum power level during the
   test. And the maximum value of the receiver should be recorded as (Pr).
3. The EUT shall be replaced by a substitution antenna. The test setup refers to figure below.




                                                                ©Copyright. All rights reserved by CTTL.


                                                                      No.I16N00975-EMC02
                                                                            Page 13 of 15


     In the chamber, an substitution antenna for the frequency band of interest is placed at the
     reference point of the chamber. An RF Signal source for the frequency band of interest is
     connected to the substitution antenna with a cable that has been constructed to not interfere
     with the radiation pattern of the antenna. A power (PMea) is applied to the input of the
     substitution antenna. Adjust the level of the signal generator output until the value of the
     receiver reaches the previously recorded (Pr). The power of signal source (PMea) is recorded.
    The test should be performed by rotating the test item and adjusting the receiving antenna
    polarization.
 4. The Path loss (Ppl) between the Signal Source with the Substitution Antenna and the
     Substitution Antenna Gain (Ga) should be recorded after test.
     An amplifier should be connected in for the test.
     The Path loss (Ppl) is the summation of the cable loss and the gain of the amplifier.
     The measurement results are obtained as described below:
     Power (EIRP) = PMea- Ppl + Ga
 5. This value is EIRP since the measurement is calibrated using an antenna of known gain (unit:
    dBi) and known input power.
 6. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP = EIRP -2.15dB.

Note: the result contains vertical part and Horizontal part

 A.2.2 Measurement Limit
 Part 22.917(a) specify that the power of any emission outside of the authorized operating frequency
 ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB.
 The specification that emissions shall be attenuated below the transmitter power (P) by at least 43 +
 10 log (P) dB, translates in the relevant power range (1 to 0.001 W) to
 -13 dBm. At 1 W the specified minimum attenuation becomes 43 dB and relative to a 30 dBm (1 W)
 carrier becomes a limit of -13 dBm. At 0.001 W (0 dBm) the minimum attenuation is 13 dB, which
 again yields a limit of -13 dBm. In this way a translation of the specification from relative to absolute
 terms is carried out.

 A.2.3 Measurement Results
 Radiated emissions measurements were made only at the upper, middle, and lower carrier
 frequencies of the CDMA BC0 (836.52MHz, 848.31MHz and 824.7MHz). It was decided that
 measurements at these three carrier frequencies would be sufficient to demonstrate compliance with
 emissions limits because it was seen that all the significant spurs occur well outside the band and no
 radiation was seen from a carrier in one block of the CDMA BC0 into any of the other blocks. The
 equipment must still, however, meet emissions requirements with the carrier at all frequencies over
 which it is capable of operating and it is the manufacturer's responsibility to verify this.




                                                                      ©Copyright. All rights reserved by CTTL.


                                                               No.116N00975—EMCO2
                                                                          Page 14 of 15


  The worst case
  CDMA BCO, Channel 384/836.52MHz
  Frequency         PMea        Pol          Ga           Peak            Limit          Polarit
   (MHz)        (dBm)       (dB)            (dBi)         ERP            (dBm>             ciarty
    7351       ~54.98      1.80             11.91        47.02           13.00           Vertical
   75285       <53.41      1.80             11.91        ~45.45          13.00           Vertical
    8369       —5514       1.90             1217         47.02           13.00           Vertical
   8727.5      —55.67      1.90              12.7        —47.02          13.00           Vertical
    9201       —50.94      210              12.89        —42.30          —13.00          Vertical
   9366.5      —55.06      210              12.89        ~46.42          13.00           Vertical
  CDMA BCO, Channel 777/848.31MHz
  Frequency         PMea        Ppl          Ga           Peak            Limit                .
   (MHz)        (dBm)       (dB)            (dBi)         ERP            (dBm)>          Polarity
    8501       ~56.20      1.90              12.7        47.55           13.00           Vertical
    8650       —55.94      1.90              12.7        47.29           —13.00          Vertical
   8689.5      —56.26      1.90              12.7        ~47.61          13.00           Vertical
    9173       ~55.86      200              12.89        4712            13.00           Vertical
    9204       —54.88      210              12.89        ~46.24          —13.00          Vertical
    9344       —55.76      210              12.96        —47.05          13.00           Vertical
  CDMA BCO, Channel 1013/824.7MHz
  Frequency         PMea        Ppl          Ga        Peak ERP           Limit          Polarity
   (MHz)            (dBm)       (dB)        (dBi)         (dBm)          (dBm>
    7422           ~54.31      1.80         11.91        ~46.35          13.00          Vertical
   81755           ~55.21      1.80         1217         —46.99          —13.00         Vertical
   9073.5          152.37      2.00         12.89        —43.63          13.00          Vertical
   92125           —55.73      210          12.89        47.09           13.00         Horizontal
    9406           —55.83      210          12.96        4712            13.00          Vertical
   99015           ~557        220          1341         ~46.95          —13.00         Vertical
Note: Expanded measurement uncertainty for CDMA800 (BC0O) is : below 3GHz: 3.14dB (k=2);
Above 3GHz: 4.86 dB (k=2)




                                                                 ©Copyright. All rights reserved by CTTL.


                                              No.I16N00975-EMC02
                                                    Page 15 of 15


ANNEX B: TEST LAYOUT




              Pic.1 Radiated spurious emission(below 3GHz)




              Pic.1 Radiated spurious emission(Above 3GHz)
                     ***END OF REPORT***



                                          ©Copyright. All rights reserved by CTTL.



Document Created: 2019-07-09 20:40:01
Document Modified: 2019-07-09 20:40:01

© 2024 FCC.report