Co-Location Test Report

FCC ID: 2ABYU-RNUC01

Test Report

Download: PDF
FCCID_4192290

RF TEST
REPORT

Report No.: RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
Supersede Report No.: RF_FCC_ SL18113001-RAD-001_Co-Location

  Applicant                  :   Radius Networks, Inc.
  Product Name               :   RadPoint NFC Reader
  Model No.                  :   RNU-C01
                                 FCC 15.247
  Test Standard              :
                                 FCC 15.225

                                 ANSI C63.10 2013
  Test Method                :
                                 KDB 558074 D01 DTS Meas Guidance v05r01
  RFID FCC ID          : 2ABYU-RNUC01
  BT FCC ID                2AA9B10
  Dates of test        : 02/01/2019 - 02/11/2019
  Issue Date           : 03/05/2019
  Test Result          : ☒ Pass             ☐ Fail
  Equipment complied with the specification                               [X]
  Equipment did not comply with the specification                         [ ]




  This Test Report is Issued Under the Authority of:




                        Shuo Zhang                                                           Chen Ge
                      RF Test Engineer                                                   Engineer Reviewer
                                           This test report may be reproduced in full only
                           Test result presented in this test report is applicable to the tested sample only



                                                  Issued By:
                                             SIEMIC Laboratories
                                  775 Montague Expressway, Milpitas, CA 95035




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                               Test report      RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                               No.
                                                               Page             2 of 16




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
           Country/Region                  Accreditation Body                                   Scope
                 USA                            FCC, A2LA                             EMC, RF/Wireless, Telecom
              Canada                         IC, A2LA, NIST                           EMC, RF/Wireless, Telecom
               Taiwan                       BSMI, NCC, NIST                            EMC, RF, Telecom, Safety
             Hong Kong                         OFTA, NIST                                RF/Wireless, Telecom
              Australia                        NATA, NIST                              EMC, RF, Telecom, Safety
               Korea                         KCC/RRA, NIST                           EMI, EMS, RF, Telecom, Safety
               Japan                     VCCI, JATE, TELEC, RFT                        EMI, RF/Wireless, Telecom
               Mexico                    NOM, COFETEL, Caniety                      EMC, RF/Wireless, Telecom, Safety
               Europe                           A2LA, NIST                             EMC, RF, Telecom, Safety
                Israel                          MOC, NIST                              EMC, RF, Telecom, Safety


                                    Accreditations for Product Certifications
               Country                      Accreditation Body                                    Scope
                 USA                          FCC TCB, NIST                                  EMC, RF, Telecom
               Canada                          IC FCB, NIST                                  EMC, RF, Telecom
              Singapore                          iDA, NIST                                   EMC, RF, Telecom
                 EU                                 NB                                      EMC & RED Directive
                Japan                         MIC (RCB 208)                                    RF, Telecom
              Hong Kong                       OFTA (US002)                                     RF, Telecom




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                    Test report           RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                                                    No.
                                                                                    Page                  3 of 16




CONTENTS
1      REPORT REVISION HISTORY .......................................................................................................................................4
2      EXECUTIVE SUMMARY.................................................................................................................................................5
3      CUSTOMER INFORMATION ..........................................................................................................................................5
4      TEST SITE INFORMATION ............................................................................................................................................5
5      MODIFICATION .............................................................................................................................................................5
6      EUT INFORMATION ......................................................................................................................................................6
     6.1    EUT Description ........................................................................................................................................................6
     6.2    Radio Description ......................................................................................................................................................6
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION .........................................................................7
     7.1    Supporting Equipment ...............................................................................................................................................7
     7.2    Cabling Description ...................................................................................................................................................7
     7.3    Test Software Description ..........................................................................................................................................7
8      TEST SUMMARY ...........................................................................................................................................................8
9      MEASUREMENT UNCERTAINTY ...................................................................................................................................9
10          MEASUREMENTS, EXAMINATION AND DERIVED RESULTS .................................................................................. 10
     10.1       Radiated Measurements ...................................................................................................................................... 10
       10.1.1       Radiated Measurements 30MHz to 1GHz ......................................................................................................... 10
       10.1.2       Radiated Spurious Emissions between 1GHz-25GHz ......................................................................................... 12
ANNEX A. TEST INSTRUMENT ........................................................................................................................................... 14
ANNEX B. SIEMIC ACCREDITATION ................................................................................................................................... 15




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                          Visit us at: www.siemic.com; Follow us at:


                                                         Test report       RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                         No.
                                                         Page              4 of 16




1    Report Revision History
                     Report No.                                  Report                 Description                 Issue Date
       RF_FCC_ SL18113001-RAD-001_Co-Location                    Version
                                                                  None                    Original                  02/11/2019
    RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0                  1.0           Updated per TCB comments           03/05/2019




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                             Test report     RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                             No.
                                                             Page            5 of 16




2     Executive Summary

The purpose of this test program was to demonstrate compliance of following product
  Company:          Radius Networks, Inc.
  Product:          RadPoint NFC Reader
  Model:            RNU-C01

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with
the Stipulated Standard listed on 1st page

3     Customer information

  Applicant Name                            Radius Networks, Inc.
  Applicant Address                         3255 Grace St NW, Washington, DC 20007
  Manufacturer Name                         Radius Networks, Inc.
  Manufacturer Address                      3255 Grace St NW, Washington, DC 20007



4     Test site information

Lab performing tests                   :   SIEMIC Laboratories
Lab Address                            :   775 Montague Expressway, Milpitas, CA 95035
FCC Test Site No.                      :   540430
IC Test Site No.                       :   4842D-2
VCCI Test Site No.                     :   A0133



5     Modification

    Index                       Item                                         Description                                 Note
      -                           -                                               -                                       -
      -                           -                                               -                                       -




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                           Test report      RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                           No.
                                                           Page             6 of 16




6       EUT Information

6.1      EUT Description


 Product Name                      RadPoint NFC Reader
  Model No.                        RNU-C01
 Trade Name                        Radius Networks, Inc.
 Serial No.                        N/A
 Input Power                       5V DC via USB
 Date of EUT received              01/01/2019
 Equipment Class/ Category         DTS, RFID
 Port/Connectors                   USB C
                                   The RNU-C01 RadPoint Reader is high performance fully NFC compliant
                                   card reader that enables a connected host computer to read loyalty
 Remark
                                   (VAS) data from Type 2 and Type 4 NFC Tags, Apple Wallet cards, and
                                   Google Pay cards.




6.2      Radio Description

Bluetooth LE:

            Radio Type                                                   Bluetooth (Ver4.1)
        Operating Frequency                                              2402MHz-2480MHz
            Modulation                                                         GFSK
         Channel Spacing                                                       2MHz
          Antenna Type                                                      PCB Antenna
           Antenna Gain                                                        -1 dBi
                Note                                                            N/A

RFID:

Radio:
               Radio Type                  RFID
          Operating Frequency              13.56MHz
               Modulation                  ASK (13.56MHz)
            Channel Spacing                None
              Antenna Type                 Loop
         Antenna Connector Type            N/A




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                               Test report     RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                               No.
                                                               Page            7 of 16




7         Supporting Equipment/Software and cabling Description
 7.1        Supporting Equipment

              Supporting Equipment
    Item                                   Model               Serial Number                 Manufacturer              Note
                  Description
      1                Laptop              N17Q1          NXGNPAA0167300AA1C7600                  Acer           To Power up the EUT
      2          Laptop Power Supply     PA-1450-26                  N/A                         LITEON                  N/A




 7.2        Cabling Description

                             Connection Start                   Connection Stop                Length / shielding Info
          Name                                                                                                                 Note
                            From        I/O Port               To           I/O Port          Length (m)     Shielding
    USB to USB C           Laptop         USB                 EUT            USB C                1          Unshielded         -



7.3        Test Software Description

       Test Item                         Software                                             Description
       RF Testing                        Tera term                      Set the EUT to transmit continuously in different test mode




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                                     Test report        RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                                     No.
                                                                     Page               8 of 16




8      Test Summary
             Test Item                      Test standard                                Test Method/Procedure                            Pass / Fail

     Band Edge and Radiated                        15.247(d)                                  ANSI C63.10:2013                           ☒ Pass
                                    FCC                                FCC
       Spurious Emissions                           15.255                         KDB 558074 D01 15.247 Meas Guidance v05               ☐ N/A

                     1.   All measurement uncertainties do not take into consideration for all presented test results.
    Remark           2.   The applicant shall ensure frequency stability by showing that an emission is maintained within the band of operation under
                          all normal operating conditions as specified in the user’s manual.




             775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                          Test report      RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                          No.
                                                          Page             9 of 16




9   Measurement Uncertainty
                                                         Emissions

             Test Item                     Frequency Range                           Description                        Uncertainty
                                                                   Confidence level of approximately 95% (in the
     AC Conducted Emissions                 150KHz – 30MHz          case where distributions are normal), with a           ±3.5dB
                                                                               coverage factor of 2
                                                                   Confidence level of approximately 95% (in the
    RF conducted measurement                150KHz – 40GHz          case where distributions are normal), with a         ±0.95dB
                                                                               coverage factor of 2
                                                                   Confidence level of approximately 95% (in the case
     Radiated Spurious Emissions             30MHz – 1GHz           where distributions are normal), with a coverage       ±6dB
                                                                      factor of 2 (for EUTs < 0.5m X 0.5m X 0.5m)
                                                                   Confidence level of approximately 95% (in the case
     Radiated Spurious Emissions             1GHz – 40GHz           where distributions are normal), with a coverage       ±6dB
                                                                      factor of 2 (for EUTs < 0.5m X 0.5m X 0.5m)




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                                Test report      RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                                No.
                                                                Page             10 of 16




10 Measurements, examination and derived results
10.1 Radiated Measurements
10.1.1 Radiated Measurements 30MHz to 1GHz
Requirement(s):
 Spec                   Requirement                                                                                       Applicable
                                                Operation within the band 13.110–14.010 MHz:
                             (a) The field strength of any emissions within the band 13.553–13.567 MHz shall
                                               not exceed 15,848 microvolts/meter at 30 meters.
                                (b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field
                               strength of any emissions shall not exceed 334 microvolts/meter at 30 meters.
                                 (c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field
                               strength of any emissions shall not exceed 106 microvolts/meter at 30 meters.
  47 CFR §15.225              (d) The field strength of any emissions appearing outside of the 13.110–14.010                     ☒
                                 MHz band shall not exceed the general radiated emission limits in §15.209.

                                      Frequency range (MHz)                      Field Strength (uV/m)
                                              30 – 88                                     100
                                             88 – 216                                     150
                                             216 960                                      200
                                            Above 960                                     500




    Test Setup




                        1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                        2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                  Maximization of the emissions, was carried out by rotating the EUT, changing the antenna
                                  polarization, and adjusting the antenna height in the following manner:
                                  a.         Vertical or horizontal polarisation (whichever gave the higher emission level over a full
     Procedure                               rotation of the EUT) was chosen.
                                  b.         The EUT was then rotated to the direction that gave the maximum emission.
                                  c.         Finally, the antenna height was adjusted to the height that gave the maximum emission.
                        3.        A Quasi-peak measurement was then made for that frequency point.
                        4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                  measured.
                                                                                               Temperature                   20.1°C
     Test Date          01/28/2019 – 01/30/2019                 Environmental conditions       Relative Humidity             36%
                                                                                               Atmospheric Pressure          1026mbar
        Remark          -

        Result          ☒ Pass            ☐ Fail

Test Data      ☒ Yes (See below)            ☐ N/A
Test Plot      ☒ Yes (See below)            ☐ N/A
Test was done by Shuo Zhang at 10-meter chamber.

            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                            Test report      RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                            No.
                                                            Page             11 of 16




Test specification:                  Radiated Emissions
Mains Power:                         5V USB
Tested by:                           Shuo Zhang                                                                       ☒ Pass
                                                                                                   Result:
                                                                                                                      ☐ Fail
Test Date:                           01/28/2019
Remarks:                             RFID and BLE radio transmit simultaneously

                                         ƒ=30MHz – 1000MHz plot and 3-meter distance




                                              ƒ=30MHz – 1000MHz Measurements

Frequency       Raw        Cable    AF       Level     Measurement                 Hgt      Azt         Limit      Margin      Pass
                                                                            Pol
   MHz         dBµV/m      Loss     dB      dBµV/m        Type                     cm       Deg        dBµV/m       dB         /Fail
  480.01         42.67     14.22   -19.06     37.84       Quasi Max         H      233       56              46     -8.16      Pass
   71.95              47   11.59   -27.95     30.64       Quasi Max         H      260       322             40     -9.36      Pass
  552.01         41.05     14.45   -18.03     37.47       Quasi Max         H      197       283             46     -8.53      Pass
  539.97         40.18     14.49   -18.68      36         Quasi Max         H      195       91              46    -10.01      Pass
  714.67         26.78     15.2    -15.86     26.12       Quasi Max         H      104       298             46    -19.88      Pass
  491.95         37.41     14.21   -18.82     32.79       Quasi Max         H      239       187             46    -13.21      Pass




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                               Test report      RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                               No.
                                                               Page             12 of 16



10.1.2 Radiated Spurious Emissions between 1GHz-25GHz
Requirement(s):
Spec                   Item         Requirement                                                                   Applicable
                                    For non-restricted band, In any 100 kHz bandwidth outside the frequency
                                    band in which the spread spectrum or digitally modulated intentional
                                    radiator is operating, the radio frequency power that is produced by the
                                    intentional radiator shall be at least 20 dB or 30dB below that in the 100
                                                                                                                           ☒
                            a)      kHz bandwidth within the band that contains the highest level of the
                                    desired power, determined by the measurement method on output power
47CFR§15.247(d)                     to be used. Attenuation below the general limits specified in § 15.209(a)
                                    is not required
                                     ☐ 20 dB down           ☒ 30 dB down
                                    or restricted band, emission must also comply with the radiated emission
                            b)                                                                                             ☐
                                    limits specified in 15.209




    Test Setup




                       1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                       2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                 Maximization of the emissions, was carried out by rotating the EUT, changing the antenna polarization,
                                 and adjusting the antenna height in the following manner:
                                 a.        Vertical or horizontal polarisation (whichever gave the higher emission level over a full
    Procedure                              rotation of the EUT) was chosen.
                                 b.        The EUT was then rotated to the direction that gave the maximum emission.
                                 c.        Finally, the antenna height was adjusted to the height that gave the maximum emission.
                       3.        An average measurement was then made for that frequency point.
                       4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                 measured.
                       The EUT was scanned up to 40GHz. Both horizontal and vertical polarities were investigated. The results
     Remark
                       show only the worst case.

       Result          ☒ Pass

Test Data       ☒ Yes (See below)           ☐ N/A

Test Plot       ☐ Yes (See below)          ☒ N/A

Test was done by Shuo Zhang at 10-meter chamber.


            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                               Test report       RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                               No.
                                                               Page              13 of 16




Test specification:                     Radiated Emissions
Mains Power:                            5V USB
Tested by:                              Shuo Zhang                                                                        ☒ Pass
                                                                                                      Result:
                                                                                                                          ☐ Fail
Test Date:                              02/01/2019
Remarks:                                RFID and BLE radio transmit simultaneously




Frequency       Raw       Cable        AF       Level     Measurement                  Hgt      Azt        Limit       Margin      Pass
                                                                               Pol
   MHz         dBµV/m     Loss         dB      dBµV/m        Type                      cm       Deg       dBµV/m        dB         /Fail
  7206.35        40.33     5.15       -0.45      45.03       Peak Max          H       116      209             74     -28.98      Pass
  9607.87        41.47      5.6        0.51      47.58       Peak Max          V       100       79             74     -26.42      Pass
  4803.83        41.35      4.1       -0.93      44.52       Peak Max          V       109      174             74     -29.48      Pass
  7206.35        28.28     5.15       -0.45      32.97     Average Max         H       116      209             54     -21.03      Pass
  9607.87        28.23      5.6        0.51      34.34     Average Max         V       100       79             54     -19.66      Pass
  4803.83        28.53      4.1       -0.93      31.71     Average Max         H       185      305             54      -22.3      Pass




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                       Test report     RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                       No.
                                                       Page            14 of 16




Annex A. TEST INSTRUMENT

         Instrument                     Model             Serial #         Cal Date      Cal Cycle       Cal Due       In use

     Radiated Emissions
      Spectrum Analyzer                N9010A            10SL0219         05/13/2018       1 Year      05/13/2019
 Bi-Log antenna (30MHz~1GHz)             JB1              A030702         03/09/2018       1 Year      03/09/2019
  Horn Antenna (1GHz~18GHz)              3115              100059         11/09/2018       1 Year      11/09/2019
 Horn Antenna (18GHz~40GHz)            PA-840              181251         06/23/2018       1 Year      06/23/2019
  Preamplifier (100KHz-7GHz)          LPA-6-30           11170602         03/09/2018       1 Year      03/09/2019

  Preamplifier (0.01-50 GHz)       RAMP00M50GA         17032300047        02/19/2018       1 Year      02/19/2019




      775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                          Visit us at: www.siemic.com; Follow us at:


                                                           Test report     RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                           No.
                                                           Page            15 of 16




Annex B. SIEMIC Accreditation

        Accreditations         Document                                        Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio Equipment: EN45011:
                                           EN ISO/IEC 17065
EU NB
                                           Electromagnetic Compatibility:
                                           EN45011 – EN ISO/IEC 17065

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
Hong Kong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                          Test report       RF_FCC_ SL18113001-RAD-001_Co-Location_Rev1.0
                                                          No.
                                                          Page              16 of 16




                                           Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                           Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                           1 of the Radio Law

                                           EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                           KN22: Test Method for EMI
                                           EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                           KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                    Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                           RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                           80, RRL Notice 2004-68

                                           Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                           attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                           LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                           PLMN08

Taiwan BSMI CAB Recognition                CNS 13438

                                           R-3083: Radiation 3 meter site
Japan VCCI                                 C-3421: Main Ports Conducted Interference Measurement
                                           T-1597: Telecommunication Ports Conducted Interference Measurement

                                           EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                           61000.6.3, AS/NZS 61000.6.4

                                           Radiocommunications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                           AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                           AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                           Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                           AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                           AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                           AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                 S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                           S043.2




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2019-03-05 12:53:32
Document Modified: 2019-03-05 12:53:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC