Test Report

FCC ID: 2ABYNX2T

Test Report

Download: PDF
FCCID_4366516

                                          FCC PART 15.249
                                              TEST REPORT
                                                             For

               GODOX PHOTO EQUIPMENT CO.LTD
19th Floor,Room 1902,Building Jinshan,5033 Shennan East Road,Luohu District,Shenzhen 518001,China


                                           FCC ID: 2ABYNX2T


            Report Type:                                Product Name:
            Original Report                             TTL Wireless Flash Trigger



                 Report Number:           RDG190529001-00B


                      Report Date:        2019-06-19


                                          Jerry Zhang
                     Reviewed By:         EMC Manager
                                          Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:         No.69 Pulongcun, Puxinhu Industry Area,
                                          Tangxia, Dongguan, Guangdong, China
                                          Tel: +86-769-86858888
                                          Fax: +86-769-86858891
                                          www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government.
* This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG190529001-00B




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  ANTENNA CONNECTOR CONSTRUCTION ......................................................................................................................8
FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS ......................................................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  EUT SETUP ..................................................................................................................................................................9
  TEST EQUIPMENT SETUP ............................................................................................................................................10
  TEST PROCEDURE ......................................................................................................................................................11
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................11
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................11
  TEST DATA ................................................................................................................................................................12
FCC §15.215(C) – 20 DB BANDWIDTH TESTING ................................................................................................17
  APPLICABLE STANDARD ............................................................................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................17
  TEST DATA ................................................................................................................................................................17




                                                                                                                                                            Page 2 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190529001-00B

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                                  EUT Name:        TTL Wireless Flash Trigger
                                  EUT Model:       X2TC
                             Multiple Models:      X2TN, X2TS, X2TO, X2TF, X2TP
                         Operation Frequency:      2412.99-2464.52 MHz
                            Modulation Type:       MSK
                          Rated Input Voltage:     DC3V from battery
                          External Dimension:      72mm(L)*70mm(W)*58mm(H)
                               Serial Number:      190529001
                          EUT Received Date:       2019-06-03

Notes: Model X2TC was selected for fully testing, the detailed information about the difference among X2TN, X2TS,
X2TO, X2TF, X2TP and model X2TC can be referred to the declaration letter which was stated and guaranteed by
the manufacturer.


Objective
This type approval report is prepared on behalf of GODOX PHOTO EQUIPMENT CO.LTD in
accordance with Part 2-Subpart J, and Part 15-Subparts A and C of the Federal Communication
Commissions rules.

The tests were performed in order to determine compliance with FCC Rules Part 15, Subpart C, and
section 15.203, 15.205, 15.209 and 15.249 rules.


Related Submittal(s)/Grant(s)
FCC Part 15.247 DTS submission with FCC ID: 2ABYNX2T


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




                                                                                                      Page 3 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190529001-00B

Measurement Uncertainty
               Parameter                                 Measurement Uncertainty
       Occupied Channel Bandwidth                                   ±5 %
                                            30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical
       Unwanted Emissions, radiated          200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical
                                                  1G~6GHz: 4.45 dB, 6G~26.5GHz: 5.23 dB
               Temperature                                          ±1℃
                 Humidity                                           ±5%
       DC and low frequency voltages                               ±0.4%
                Duty Cycle                                           1%
        AC Power Lines Conducted                          3.12 dB (150 kHz to 30 MHz)
                 Emission


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier: CN0022.




                                                                                                Page 4 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190529001-00B

SYSTEM TEST CONFIGURATION
Justification
The EUT was configured in operating mode for testing which was provided by the manufacturer.

The device employs total 32 channels, please refer the circuit description.

2412.99MHz, 2437.99 MHz, 2464.52 MHz was selected for test.


EUT Exercise Software
No software was used in test.


Equipment Modifications
No modifications were made to the EUT.


Local Support Equipment List and Details

        Manufacturer                   Description             Model               Serial Number
           Cannon                        Camera                   /                      /
           GODOX             Wireless Original Flash Trigger   TT585C                    /



Support Cable List and Details

          Cable            Shielding                     Length
                                        Ferrite Core                     From Port                 To
        Description          Type                         (m)
             /                  /             /             /                  /                   /




                                                                                                   Page 5 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190529001-00B

Block Diagram of Test Setup

Radiated Emissions:




                                                                      Page 6 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190529001-00B


SUMMARY OF TEST RESULTS

                  FCC Rules                      Description of Test         Result

                    §15.203                     Antenna Requirement        Compliance

                  §15.207(a)                    Conduction Emissions     Not Applicable

           15.205, §15.209, §15.249              Radiated Emissions        Compliance

                  §15.215 (c)                        20 dB Bandwidth       Compliance


Not Applicable: this device is powered by battery.




                                                                                          Page 7 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG190529001-00B

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
For intentional device, according to §15.203, an intentional radiator shall be designed to ensure that no
antenna other than that furnished by the responsible party shall be used.


Antenna Connector Construction
The EUT has one internal antenna arrangement, and the antenna gain is 0 dBi, fulfill the requirement of
this section. Please refer to the EUT photos.

Result: Compliant.




                                                                                                  Page 8 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190529001-00B

FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS
Applicable Standard

As per FCC§15.249 (a), except as provided in paragraph (b) of this section, the field strength of emissions
from intentional radiators operated within these frequency bands shall comply with the following:


            Fundamental         Field strength of fundamental       Field strength of harmonics
             frequency                 (millivolts/meter)                (microvolts/meter)

            902–928 MHz                       50                                500

          2400–2483.5 MHz                     50                                500

           5725–5875 MHz                      50                                500

           24.0–24.25 GHz                    250                                2500


  As per FCC§15.249 (c), Field strength limits are specified at a distance of 3 meters.

 (d) Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated
  by at least 50 dB below the level of the fundamental or to the general radiated emission limits in §15.209,
  whichever is the lesser attenuation.


EUT Setup
Below 1 GHz:




                                                                                                  Page 9 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG190529001-00B

Above 1 GHz:




The radiated emission below 1GHz tests were performed in the 3 meters chamber test site A, above 1GHz
tests were performed in the 3 meters chamber test site B, using the setup accordance with the ANSI
C63.10-2013. The specification used was the FCC 15.209, and FCC 15.249 limits.


Test Equipment Setup
The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

               Frequency Range           RBW         Video B/W        IF B/W        Measurement
             30 MHz – 1000 MHz          120 kHz        300 kHz       120 kHz             QP
                                         1MHz          3 MHz             /               PK
                Above 1 GHz
                                         1MHz           10 Hz            /               AV

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.




                                                                                              Page 10 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190529001-00B

Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

All data was recorded in the Quasi-peak detection mode from 30 MHz to 1GHz, peak and average
detection mode above 1 GHz.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude


Test Equipment List and Details

                                                                       Serial       Calibration    Calibration
    Manufacturer           Description             Model
                                                                      Number           Date         Due Date
        R&S            EMI Test Receiver           ESCI                100224       2018-12-10     2019-12-10
        Farad            Test Software           EZ-EMC               V1.1.4.2         N/A            N/A
    Sunol Sciences          Antenna                 JB3              A060611-1      2017-11-10     2020-11-10
      Unknown            Coaxial Cable          C-NJNJ-50            C-0400-01      2018-09-05     2019-09-05
      Unknown            Coaxial Cable          C-NJNJ-50            C-0075-01      2018-09-05     2019-09-05
      Unknown            Coaxial Cable          C-NJNJ-50            C-1400-01      2018-09-05     2019-09-05
         HP                Amplifier              8447D             2727A05902      2018-09-05     2019-09-05
       Agilent         Spectrum Analyzer         E4440A             SG43360054      2019-01-04     2020-01-04
    ETS-Lindgren         Horn Antenna              3115              000 527 35     2018-10-12     2021-10-12
                                            AFS42-00101800-25-
        MITEQ               Amplifier                                 2001271       2018-09-05     2019-09-05
                                                   S-42
        Unknown            Coaxial Cable        C-SJSJ-50              C-0800-01     2018-09-05 2019-09-05
        Unknown            Coaxial Cable       C-2.4J2.4J-50           C-0700-02     2018-06-27 2019-06-27
       Ducommun                                                       1007726-01
                           Horn Antenna          ARH-4223-02                         2016-11-18 2019-11-18
      Technolagies                                                        1304
        Quinstar             Amplifier        QLW-18405536-JO 15964001001 2018-06-27 2019-06-27
     E-Microwave         Band-stop Filters OBSF-2400-2483.5-S OE01601525 2018-06-16 2019-06-16
     Micro-tronics       High Pass Filter         HPM50111             S/N-G217      2018-06-16 2019-06-16
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                     Page 11 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190529001-00B

Test Data
     Environmental Conditions

              Temperature:              26.4oC
         Relative Humidity:              64 %
            ATM Pressure:              101.0kPa

* The testing was performed by Lucy Lu on 2019-06-05.

Test Mode: Transmitting

1) 30MHz-1GHz (High channel is the worst):
Horizontal:




                    Receiver                      Correction     Cord.
    Frequency                                                                 Limit        Margin
                    Reading         Detector       Factor        Amp.
      (MHz)                                                                 (dBuV/m)        (dB)
                    (dBuV)                         (dB/m)      (dBuV/m)
     30.9700         27.85            peak           0.91        28.76         40.00        11.24
    126.0300         27.27            peak          -4.69        22.58         43.50        20.92
    385.9900         31.11            peak          -2.38        28.73         46.00        17.27
    574.1700         28.28            peak           1.07        29.35         46.00        16.65
    796.3000         27.40            peak           4.31        31.71         46.00        14.29
    977.6900         33.22            peak           1.29        34.51         54.00        19.49




                                                                                           Page 12 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190529001-00B

Vertical:




                   Receiver                     Correction     Cord.
   Frequency                                                                Limit        Margin
                   Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                   (dBuV)                        (dB/m)      (dBuV/m)

     35.8200         32.02          peak            -2.59     29.43          40.00        10.57
    200.7200         36.12          peak            -5.88     30.24          43.50        13.26
    362.7100         30.18          peak            -2.81     27.37          46.00        18.63
    438.3700         31.60          peak            -1.22     30.38          46.00        15.62
    534.4000         29.79          peak            0.32      30.11          46.00        15.89
    905.9100         33.04          peak            0.20      33.24          46.00        12.76




                                                                                         Page 13 of 19


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190529001-00B

 2) 1GHz-25GHz

                 Receiver            Rx Antenna       Cable Amplifier   Corrected
Frequency                                                                             Limit    Margin
            Reading                Polar    Factor      loss    Gain    Amplitude
  (MHz)               Detector                                                      (dBμV/m)    (dB)
            (dBμV)                 (H/V) (dB/m)        (dB)     (dB)    (dBμV/m)
                                         Low Channel: 2412.99 MHz
 2412.99      69.39       PK         H      28.13      1.81      0.00     99.33      113.98     14.65
 2412.99      54.27       AV         H      28.13      1.81      0.00     84.21      93.98       9.77
 2412.99      59.29       PK         V      28.13      1.81      0.00     89.23      113.98     24.75
 2412.99      44.35       AV         V      28.13      1.81      0.00     74.29      93.98      19.69
 2400.00      34.43       PK         H      28.10      1.80      0.00     64.33      74.00       9.67
 2400.00      12.94       AV         H      28.10      1.80      0.00     42.84      54.00      11.16
 4825.98      53.03       PK         H      32.95      3.20     37.20     51.98      74.00      22.02
 4825.98      39.61       AV         H      32.95      3.20     37.20     38.56      54.00      15.44
 7238.97      44.00       PK         H      35.82      4.76     37.27     47.31      74.00      26.69
 7238.97      31.40       AV         H      35.82      4.76     37.27     34.71      54.00      19.29
                                       Middle Channel: 2437.99 MHz
 2437.99      68.77       PK         H      28.18      1.82      0.00     98.77      113.98     15.21
 2437.99      53.65       AV         H      28.18      1.82      0.00     83.65      93.98      10.33
 2437.99      60.64       PK         V      28.18      1.82      0.00     90.64      113.98     23.34
 2437.99      45.56       AV         V      28.18      1.82      0.00     75.56      93.98      18.42
 4875.98      54.30       PK         H      33.05      3.27     37.21     53.41      74.00      20.59
 4875.98      40.38       AV         H      33.05      3.27     37.21     39.49      54.00      14.51
 7313.97      44.26       PK         H      36.02      4.63     37.37     47.54      74.00      26.46
 7313.97      31.29       AV         H      36.02      4.63     37.37     34.57      54.00      19.43
                                         High Channel: 2464.52 MHz
 2464.52      68.36       PK         H      28.23      1.83      0.00     98.42      113.98     15.56
 2464.52      54.21       AV         H      28.23      1.83      0.00     84.27      93.98       9.71
 2464.52      60.05       PK         V      28.23      1.83      0.00     90.11      113.98     23.87
 2464.52      44.92       AV         V      28.23      1.83      0.00     74.98      93.98      19.00
 2483.50      31.00       PK         H      28.27      1.84      0.00     61.11      74.00      12.89
 2483.50      14.56       AV         H      28.27      1.84      0.00     44.67      54.00       9.33
 4929.04      55.20       PK         H      33.16      3.27     37.23     54.40      74.00      19.60
 4929.04      41.64       AV         H      33.16      3.27     37.23     40.84      54.00      13.16
 7393.56      44.73       PK         H      36.22      4.50     37.47     47.98      74.00      26.02
 7393.56      31.89       AV         H      36.22      4.50     37.47     35.14      54.00      18.86




                                                                                         Page 14 of 19


    Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190529001-00B

    Test plots (High channel):
    Horizontal


Fundamental
test with Filter




                                                                         Page 15 of 19


    Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190529001-00B

    Vertical




Fundamental
test with Filter




                                                                         Page 16 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190529001-00B


FCC §15.215(c) – 20 dB BANDWIDTH TESTING
Applicable Standard
Intentional radiators operating under the alternative provisions to the general emission limits, as contained
in §§ 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB
bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section
under which the equipment operates, is contained within the frequency band designated in the rule section
under which the equipment is operated.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference
   level. Record the frequency difference as the emission bandwidth.
3. Repeat above procedures until all frequencies measured were complete.


Test Equipment List and Details

                                                                    Serial        Calibration    Calibration
     Manufacturer           Description              Model
                                                                   Number            Date         Due Date

          R&S           Spectrum Analyzer            FSV40          101474        2019-01-09      2020-01-09

       Unknown             Coaxial Cable           C-SJ00-0010     C0010/04        Each time         N/A


* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                 26.1 oC
         Relative Humidity:                 52 %
            ATM Pressure:               100.5 kPa

    The testing was performed by Carrie He on 2019-06-07.

Test Result: Compliant.

Please refer to following tables and plots




                                                                                                     Page 17 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)                  Report No.: RDG190529001-00B

Test Mode: Transmitting

                                             Frequency      20 dB Bandwidth
                          Channel
                                               (MHz)             (MHz)
                           Low                2412.99             0.810
                          Middle              2437.99             0.808
                           High               2464.52             0.800

                                              Low Channel




                                                                                    Page 18 of 19


Bay Area Compliance Laboratories Corp. (Dongguan)             Report No.: RDG190529001-00B


                                             Middle Channel




                                              High Channel




                                  ***** END OF REPORT *****