Test Report

FCC ID: 2ABYNTT350

Test Report

Download: PDF
FCCID_3263882

                                       FCC PART 15.249
                                          TEST REPORT
                                                          For

               GODOX PHOTO EQUIPMENT CO.LTD
           19th Floor,Room 1902,Building Jinshan,5033 Shennan East Road,Luohu
                             District,Shenzhen 518001,China


                                       FCC ID: 2ABYNTT350


            Report T ype:                            Product Name:
            Ori ginal Report                         Thinkl ite TTL Cam era Flash




                 Test Engineer:         Lorin Bian


               Report Number:           RDG161214005B


                    Report Date:        2017-01-04
                                        Henry Ding
                                        EMC Leader
                  Reviewed By:

              Test Laboratory:          Bay Area Compliance Laboratories Corp. (Chengdu)
                                        5040, HuiLongWan Plaza, No. 1, ShaWan Road,
                                        JinNiu District, ChengDu, China
                                        Tel: 028-65523123, Fax: 028-65525125
                                        www.baclcorp.com




Note: This test report was prepared for the customer shown above and for the device described herein. It may not be
      duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.
      (Chengdu). Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
      unlawful and offenders may be prosecuted to the fullest extent of the law. This report was valid only with a valid
      digital signature.


Bay Area Compliance Laboratories Corp. (Chengdu)




                                                 TABLE OF CONTENTS

GENERAL INFORMATION ....................................................................................................................... 3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...................................................................... 3
 OBJECTIVE .............................................................................................................................................. 3
 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................ 3
 TEST METHODOLOGY ............................................................................................................................... 3
 TEST FACILITY ......................................................................................................................................... 4
SYSTEM TEST CONFIGURATION ........................................................................................................... 5
  JUSTIFICATION ......................................................................................................................................... 5
  EUT EXERCISE SOFTWARE ...................................................................................................................... 5
  EQUIPMENT MODIFICATIONS ..................................................................................................................... 5
  SUPPORT EQUIPMENT LIST AND DETAILS.................................................................................................... 6
  BLOCK DIAGRAM OF TEST SETUP .............................................................................................................. 6
SUMMARY OF TEST RESULTS ............................................................................................................... 7
FCC§15.203 - ANTENNA REQUIREMENT ............................................................................................... 8
  APPLICABLE STANDARD ............................................................................................................................ 8
  ANTENNA CONNECTOR CONSTRUCTION ..................................................................................................... 8
FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS ........................................................................ 9
  APPLICABLE STANDARD ............................................................................................................................ 9
  MEASUREMENT UNCERTAINTY .................................................................................................................. 9
  EUT SETUP .......................................................................................................................................... 10
  TEST EQUIPMENT SETUP ........................................................................................................................ 11
  TEST PROCEDURE ................................................................................................................................. 11
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................... 11
  TEST EQUIPMENT LIST AND DETAILS ........................................................................................................ 12
  TEST RESULTS SUMMARY ....................................................................................................................... 12
  TEST DATA ........................................................................................................................................... 12
FCC §15.215(C) – 20 DB BANDWIDTH TESTING .................................................................................. 14
  APPLICABLE STANDARD .......................................................................................................................... 14
  TEST PROCEDURE ................................................................................................................................. 14
  TEST EQUIPMENT LIST AND DETAILS ........................................................................................................ 14
  TEST DATA ........................................................................................................................................... 14




Report No.: RDG161214005B                                                                                                             Page 2 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The GODOX PHOTO EQUIPMENT CO.LTD’s product, model number: TT350s
(FCC ID: 2ABYNTT350) (the "EUT") in this report was a Thinklite TTL Camera Flash, which
was measured approximately: 14.2 cm (L) x 6.2 cm (W) x 3.9 cm (H), rated input voltage: DC 3V
from battery.

Note: The series product, model TT350s, TT350c, TT350n are electrically identical, the difference between
them is the different hotshoe control function, we selected TT350s for fully testing, the details was
explained in the declaration letter.

*All measurement and test data in this report was gathered from final production sample, serial number:
161214005 (assigned by the BACL, Chengdu). It may have deviation from any other sample. The EUT
supplied by the applicant was received on 2016-12-15, and EUT conformed to test requirement.


Objective
This type approval report is prepared on behalf of GODOX PHOTO EQUIPMENT CO.LTD in
accordance with Part 2-Subpart J, and Part 15-Subparts A, B and C of the Federal
Communication Commissions rules.
The tests were performed in order to determine compliance with FCC Part 15, Subpart C, and
section 15.203, 15.205, 15.209 and 15.249 rules.

Related Submittal(s)/Grant(s)
No related submittal(s)/grant(s).

Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American
National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

The uncertainty of any RF tests which use conducted method measurement is ±3.17 dB, the
uncertainty of any radiation on emissions measurement is:

30M~200MHz: ±4.7 dB;
200M~1GHz: ±6.0 dB;
1G~6GHz: ±5.13dB;
6G~25GHz: ±5.47dB;

And the uncertainty will not be taken into consideration for all test data recorded in the report.




Report No.: RDG161214005B                                                                  Page 3 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

Test Facility
The test site used by BACL to collect test data is located in the 5040, HuiLongWan Plaza, No. 1,
ShaWan Road, JinNiu District, ChengDu, China.

Test site at BACL has been fully described in reports submitted to the Federal Communication
Commission (FCC). The details of these reports have been found to be in compliance with the
requirements of Section 2.948 of the FCC Rules on April 24, 2015. The facility also complies
with the radiated and AC line conducted test site criteria set forth in ANSI C63.4-2014.

The Federal Communications Commission has the reports on file and is listed under FCC
Registration No.: 560332. The test site has been approved by the FCC for public use and is listed
in the FCC Public Access Link (PAL) database.




Report No.: RDG161214005B                                                           Page 4 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in Engineering Mode, which was provided by the
manufacturer.
The Engineering mode was switched channel by keys.
The system was configured for testing in a testing mode which was selected by manufacturer.
16 channels are provided for testing: channel 1, 8 and 16 were selected to test.

                                   Frequency                          Frequency
                  Channel                             Channel
                                     (MHz)                              (MHz)
                      1               2413               9               2426
                      2              2414.5             10               2428
                      3               2416              11              2429.5
                      4               2418              12               2431
                      5              2419.5             13               2433
                      6               2421              14              2434.5
                      7               2423              15               2436
                      8              2424.5             16               2438

And channel 1,8, 16 was chose for testing.

EUT Exercise Software
No software was used during testing.


Equipment Modifications
No modifications were made to the EUT.




Report No.: RDG161214005B                                                          Page 5 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

Support Equipment List and Details

      Manufacturer                Description       Model     Serial Number
          Canon                 Digital Camera     DS126131       N/A


Block Diagram of Test Setup




Report No.: RDG161214005B                                            Page 6 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)


SUMMARY OF TEST RESULTS

                FCC Rules                 Description of Test       Result

                  §15.203                 Antenna Requirement     Compliance

                §15.207(a)                Conduction Emissions   Not Applicable

         15.205, §15.209, §15.249          Radiated Emissions     Compliance

                §15.215 (c)                 20 dB Bandwidth       Compliance


Note: It is battery operated equipment.




Report No.: RDG161214005B                                                         Page 7 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
For intentional device, according to §15.203, an intentional radiator shall be designed to ensure
that no antenna other than that furnished by the responsible party shall be used.

Antenna Connector Construction
The EUT has an internal antenna, the antenna gain is 0dBi, fulfill the requirement of this section.
Please refer to the EUT photos.
Result: Compliant.




Report No.: RDG161214005B                                                             Page 8 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS
Applicable Standard

As per FCC§15.249 (a), except as provided in paragraph (b) of this section, the field strength of
emissions from intentional radiators operated within these frequency bands shall comply with the
following:


          Fundamental       Field strength of fundamental    Field strength of harmonics
           frequency               (millivolts/meter)             (microvolts/meter)

          902–928 MHz                    50                              500

        2400–2483.5 MHz                  50                              500

         5725–5875 MHz                   50                              500

         24.0–24.25 GHz                  250                            2500


  As per FCC§15.249 (c), Field strength limits are specified at a distance of 3 meters.

 (d) Emissions radiated outside of the specified frequency bands, except for harmonics, shall be
  attenuated by at least 50 dB below the level of the fundamental or to the general radiated
  emission limits in §15.209, whichever is the lesser attenuation.


Measurement Uncertainty
Compliance or non- compliance with a disturbance limit shall be determined in the following
manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the
disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr),
exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab −
Ucispr), exceeds the disturbance limit.

Based on CISPR 16-4-2-2011, measurement uncertainty of radiated emission at a distance of
3m at Bay Area Compliance Laboratories Corp. (Chengdu) is:
30M~200MHz: ±4.7 dB;
200M~1GHz: ±6.0 dB;
1G~6GHz: ±5.13dB;
6G~25GHz: ±5.47 dB;




Report No.: RDG161214005B                                                            Page 9 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

                                      Table 1 – Values of Ucispr

                                      Measurement                                             Ucispr
Radiated disturbance (electric field strength at an OATS or in a SAC) (30 MHz to 1000 MHz)   6.3 dB
Radiated disturbance (electric field strength in a FAR)           (1 GHz to 6 GHz)           5.2 dB
Radiated disturbance (electric field strength in a FAR)           (6 GHz to 18 GHz)          5.5 dB


EUT Setup
Below 1 GHz:




Above 1 GHz:




The radiated emission and out of band emission tests were performed in the 3 meters chamber
test site, using the setup accordance with the ANSI C63.10-2013 The specification used was the
FCC 15.209/15.205 and FCC 15.249 limits.


Report No.: RDG161214005B                                                                Page 10 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

Test Equipment Setup
The system was investigated from 30 MHz to 25 GHz.
During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with
the following configurations:

            Frequency Range          RBW           Video B/W    IF B/W      Detector
           30 MHz – 1000 MHz        120 kHz         300 kHz    120 kHz         QP
                                     1MHz           3 MHz          /           PK
              Above 1 GHz
                                     1MHz            10 Hz         /           AV


Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied
with all installation combinations.

All data was recorded in the Quasi-peak detection mode from 30 MHz to 1GHz, peak and
average detection mode above 1 GHz.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and
subtracting the Amplifier Gain from the Meter Reading. The basic equation is as follows:
       Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The
equation for margin calculation is as follows:
       Margin = Limit –Corrected Amplitude




Report No.: RDG161214005B                                                           Page 11 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

Test Equipment List and Details

                                                              Serial      Calibration   Calibration
     Manufacturer           Description       Model
                                                             Number          Date        Due Date
         Agilent             Amplifier        8447D        2944A10442     2016-12-02    2017-12-01
   Rohde & Schwarz EMI Test Receiver     ESCI                100028       2016-12-02     2017-12-01
                      Broadband
    Sunol Sciences                       JB3                 A101808      2016-04-10    2019-04-09
                       Antenna
                       Spectrum
   Rohde & Schwarz                     FSEM30                100018       2016-12-02    2017-12-01
                       Analyzer
         ETS        Horn Antenna         3115                003-6076     2016-12-02    2017-12-01
      Ducommun                                               1007726-
                    Horn Antenna     ARH-4223-02                          2014-06-16     2017-06-15
     Technologies                                            0113024
      Mini-circuits    Amplifier     ZVA-183-S+             771001215     2016-05-20    2017-05-19
          HP           Amplifier        8449B              3008A00277     2016-12-02    2017-12-01
                    Semi-Anechoic
        EMCT                             966                   N/A        2015-04-24     2018-04-23
                       Chamber
                       RF Cable
          N/A                           NO.1                   N/A        2016-11-10     2017-11-09
                    (below 1GHz)
                       RF Cable
          N/A                           NO.4                   N/A        2016-11-10     2017-11-09
                    (below 1GHz)
                       RF Cable
          N/A                           NO.2                   N/A        2016-11-10     2017-11-09
                    (above 1GHz)

* Statement of Traceability: BACL (Chengdu) attested that all calibrations have been performed,
traceable to National Primary Standards and International System of Units (SI).


Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209 &15.205
& 15.249.

Test Data
    Environmental Conditions
                                         o
            Temperature:          24.6 C
       Relative Humidity:          42 %
          ATM Pressure:          101.1 kPa

    The testing was performed by Lorin Bian on 2016-12-26.

    Test Mode: Transmitting




Report No.: RDG161214005B                                                                 Page 12 of 16


  Bay Area Compliance Laboratories Corp. (Chengdu)

  30MHz-25GHz:

                Receiver           Rx Antenna       Cable Amplifier   Corrected
Frequency                                                                           Limit    Margin
            Reading              Polar     Factor    loss    Gain     Amplitude
  (MHz)              Detector                                                     (dBμV/m)    (dB)
            (dBμV)               (H/V) (dB(1/m)) (dB)        (dB)     (dBμV/m)
                                        frequency: 2413 MHz
  2413       55.76      PK         H       23.50     3.00    0.00       82.26      114.00    31.74
  2413       43.37      AV         H       23.50     3.00    0.00       69.87       94.00    24.13
  2413       58.82      PK         V       23.50     3.00    0.00       85.32      114.00    28.68
  2413       45.69      AV         V       23.50     3.00    0.00       72.19       94.00    21.81
  2400       24.27      PK         V       23.54     3.00    0.00       50.81       74.00    23.19
  2400       12.92      AV         V       23.54     3.00    0.00       39.46       54.00    14.54
  4826       39.46      PK         V       30.84     5.11    26.87      48.54       74.00    25.46
  4826       26.75      AV         V       30.84     5.11    26.87      35.83       54.00    18.17
  7239       34.02      PK         V       34.78     6.18    26.37      48.61       74.00    25.39
  7239       22.73      AV         V       34.78     6.18    26.37      37.32       54.00    16.68
  2102       33.55      PK         V       24.55     3.04    26.83      34.31       74.00    39.69
  2102       21.09      AV         V       24.55     3.04    26.83      21.85       54.00    32.15
 468.44      42.25      QP         V       17.74     1.54    28.63      32.90       46.00    13.10
 519.85       40        QP         V       18.30     1.66    28.82      31.14       46.00    14.86
                                       frequency: 2424.5 MHz
 2424.5      56.41      PK         H       23.46     3.00    0.00       82.87      114.00    31.13
 2424.5      44.27      AV         H       23.46     3.00    0.00       70.73       94.00    23.27
 2424.5      59.48      PK         V       23.46     3.00    0.00       85.94      114.00    28.06
 2424.5      46.54      AV         V       23.46     3.00    0.00       73.00       94.00    21.00
  4849       39.81      PK         V       30.92     5.10    26.87      48.96       74.00    25.04
  4849       27.23      AV         V       30.92     5.10    26.87      36.38       54.00    17.62
 7273.5      34.08      PK         V       34.85     6.20    26.38      48.75       74.00    25.25
 7273.5      22.79      AV         V       34.85     6.20    26.38      37.46       54.00    16.54
  2145       33.14      PK         V       24.41     3.03    26.84      33.74       74.00    40.26
  2145       20.85      AV         V       24.41     3.03    26.84      21.45       54.00    32.55
  3012       32.55      PK         V       24.27     3.45    26.41      33.86       74.00    40.14
  3012       20.13      AV         V       24.27     3.45    26.41      21.44       54.00    32.56
 468.44      42.22      QP         V       17.74     1.54    28.63      32.87       46.00    13.13
 519.85      40.29      QP         V       18.30     1.66    28.82      31.43       46.00    14.57
                                        frequency: 2438 MHz
  2438       55.71      PK         H       23.41     3.00    0.00       82.12      114.00    31.88
  2438       43.86      AV         H       23.41     3.00    0.00       70.27       94.00    23.73
  2438       59.25      PK         V       23.41     3.00    0.00       85.66      114.00    28.34
  2438       45.56      AV         V       23.41     3.00    0.00       71.97       94.00    22.03
 2483.5      25.59      PK         V       23.26     2.99    0.00       51.84       74.00    22.16
 2483.5      13.25      AV         V       23.26     2.99    0.00       39.50       54.00    14.50
  4876       39.22      PK         V       31.00     5.09    26.87      48.44       74.00    25.56
  4876       27.03      AV         V       31.00     5.09    26.87      36.25       54.00    17.75
  7314       34.47      PK         V       34.93     6.21    26.40      49.21       74.00    24.79
  7314       22.34      AV         V       34.93     6.21    26.40      37.08       54.00    16.92
  3045       33.48      PK         V       24.45     3.50    26.43      35.00       74.00    39.00
  3045       21.37      AV         V       24.45     3.50    26.43      22.89       54.00    31.11
 468.44      42.39      QP         V       17.74     1.54    28.63      33.04       46.00    12.96
 519.85      41.08      QP         V       18.30     1.66    28.82      32.22       46.00    13.78




  Report No.: RDG161214005B                                                         Page 13 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

FCC §15.215(c) – 20 dB BANDWIDTH TESTING
Applicable Standard
Intentional radiators operating under the alternative provisions to the general emission limits, as
contained in §§ 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure
that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in
the specific rule section under which the equipment operates, is contained within the frequency
band designated in the rule section under which the equipment is operated.

Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a
   known signal from an external generator.
2. Position the EUT on the test table without connection to measurement instrument. Turn on
   the EUT. Then set it to any one convenient frequency within its operating range. Set a
   reference level on the measuring instrument equal to the highest peak value.
3. Measure the frequency difference of two frequencies that were attenuated 20 dB from the
   reference level. Record the frequency difference as the emission bandwidth.
4. Repeat above procedures until all frequencies measured were complete.


Test Equipment List and Details

                                                               Serial     Calibration   Calibration
    Manufacturer         Description          Model
                                                              Number         Date        Due Date
       Rohde &
                       Signal Analyzer       FSIQ26          831929/005   2016-09-21    2017-09-20
       Schwarz
         N/A                RF Cable           N/A              N/A        Each Time          /

* Statement of Traceability: BACL (Chengdu) attested that all calibrations have been performed,
traceable to National Primary Standards and International System of Units (SI).


Test Data
    Environmental Conditions
                                       o
            Temperature:         26.3 C
       Relative Humidity:         34 %
          ATM Pressure:         101.8 kPa


    The testing was performed by Lorin Bian on 2016-12-28.

      Test Result: Compliant.
      Please refer to following tables and plots




Report No.: RDG161214005B                                                                 Page 14 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)

   Test Mode: Transmitting

                                                  Frequency                  20 dB Bandwidth
                         Channel
                                                    (MHz)                         (MHz)
                            Low                      2413                          0.79
                           Middle                      2424.5                           0.90
                            High                        2438                            0.81



                                                     Low Channel
                                      Delta 1 [T1]              RBW    30 kHz         RF Att     30 dB
                      Ref Lvl                        1.22 dB    VBW   100 kHz
                       10 dBm              787.57515031 kHz     SWT   8.5 ms          Unit          dBm
                 10
                        0.5 dB Offset                                       1 [T1]           -23.41 dBm
                                                                                                           A
                                                                                       2.41259419 GHz
                  0
                                                                            1 [T1]             1.22 dB
                       D1 -3.11 dBm
                                                                                     787.57515031 kHz
                -10                                                        OPB       793.58717435 kHz
                                                                            T1 [T1]          -22.70 dBm
                                                                                       2.41260020 GHz
                -20                              T1                   1
                                                 1                          T2 [T1]          -24.77 dBm
                                                                      T2
                       1MAX D2
                            D -23.11 dBm                                                                  1MA
                                                                                       2.41339379 GHz
                -30



                -40



                -50



                -60



                -70



                -80



                -90
                      Center 2.413 GHz                   300 kHz/                            Span 3 MHz

               Date:        28.DEC.2016    09:49:57




Report No.: RDG161214005B                                                                                       Page 15 of 16


Bay Area Compliance Laboratories Corp. (Chengdu)


                                                    Middle Channel
                                      Delta 1 [T1]                 RBW       30 kHz         RF Att      30 dB
                      Ref Lvl                       -0.41 dB       VBW   100 kHz
                       10 dBm              895.79158317 kHz        SWT   8.5 ms             Unit           dBm
                 10
                        0.5 dB Offset                                             1 [T1]           -23.91 dBm
                                                                                                                  A
                                                                                             2.42399800 GHz
                  0
                                                                                  1 [T1]             -0.41 dB
                       D1 -3.49 dBm
                                                                                           895.79158317 kHz
                -10                                                           OPB          913.82765531 kHz
                                                                                  T1 [T1]          -26.01 dBm
                                                                                             2.42406413 GHz
                -20
                                               1                         1        T2 [T1]          -25.70 dBm
                       1MAX D2
                            D -23.49 dBm           T1                        T2                                  1MA
                                                                                             2.42497796 GHz
                -30



                -40



                -50



                -60



                -70



                -80



                -90
                      Center 2.4245 GHz                     300 kHz/                               Span 3 MHz

               Date:        28.DEC.2016    09:53:32

                                                        High Channel
                                      Delta 1 [T1]                 RBW       30 kHz         RF Att      30 dB
                      Ref Lvl                           0.96 dB    VBW   100 kHz
                       10 dBm              811.62324650 kHz        SWT   8.5 ms             Unit           dBm
                 10
                        0.5 dB Offset                                             1 [T1]           -23.88 dBm
                                                                                                                  A
                                                                                             2.43757615 GHz
                  0
                                                                                  1 [T1]             0.96 dB
                       D1 -3.49 dBm
                                                                                           811.62324650 kHz
                -10                                                           OPB          997.99599198 kHz
                                                                                  T1 [T1]          -26.04 dBm
                                                                                             2.43750401 GHz
                -20                                                      1
                                                    1                          T2 [T1]             -25.65 dBm
                       1MAX D2
                            D -23.49 dBm       T1                            T2                                  1MA
                                                                                             2.43850200 GHz
                -30



                -40



                -50



                -60



                -70



                -80



                -90
                      Center 2.438 GHz                      300 kHz/                               Span 3 MHz

               Date:        28.DEC.2016    09:57:36



                                           ***** END OF REPORT *****


Report No.: RDG161214005B                                                                                              Page 16 of 16



Document Created: 2017-01-13 20:33:38
Document Modified: 2017-01-13 20:33:38