Test Report

FCC ID: 2ABYNAMI

Test Report

Download: PDF
FCCID_3885558

                                           FCC PART 15.247
                                               TEST REPORT

                                                              For

               GODOX PHOTO EQUIPMENT CO.LTD
          19th Floor,Room 1902,Building Jinshan,5033 Shennan, East Road,Luohu District,
                                    Shenzhen 518001,China


                                            FCC ID: 2ABYNAMI


            Report Type:                                 Product Name:
            Original Report                              S martphone Flash


                  Report Number:           RDG180503003-00B


                      Report Date:         2018-05-25

                                           Jerry Zhang
                                           EMC Manager
                     Reviewed By:

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG180503003-00B




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................7
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................8
SUMMARY OF TEST RESULTS ...............................................................................................................................9
FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE..........................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA INFORMATION AND CONNECTOR CONSTRUCTION.....................................................................................11
FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS ......................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST DATA ................................................................................................................................................................14
FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS .................................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST DATA ................................................................................................................................................................18
FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH .............................................................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................24
FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER ......................................................27
  APPLICABLE STANDARD ............................................................................................................................................27
  TEST PROCEDURE ......................................................................................................................................................27
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................27

FCC Part 15.247                                                                                                                                         Page 2 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG180503003-00B


    TEST DATA ................................................................................................................................................................28
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................29
  APPLICABLE STANDARD ............................................................................................................................................29
  TEST PROCEDURE ......................................................................................................................................................29
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................29
  TEST DATA ................................................................................................................................................................29
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................31
  APPLICABLE STANDARD ............................................................................................................................................31
  TEST PROCEDURE ......................................................................................................................................................31
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................31
  TEST DATA ................................................................................................................................................................31




FCC Part 15.247                                                                                                                                          Page 3 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG180503003-00B

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                          EUT Name:      Smartphone Flash
                          EUT Model:     Ami
                              FCC ID:    2ABYNAMI
                  Rated Input Voltage:   DC 3.8V from battery or DC 5V from USB port
                  External Dimension:    Length (60 mm)*Width (46 mm)*High (17 mm)
                       Serial Number:    180503003
                  EUT Received Date:     2018.05.03


Objective
This report is prepared on behalf of GODOX PHOTO EQUIPMENT CO.LTD in accordance with Part 2,
Subpart J, Part 15, Subparts A, and C of the Federal Communications Commission’s rules.

The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15-
Subpart C, section 15.203, 15.205,15.207, 15.209, 15.247 rules.


Related Submittal(s)/Grant(s)
N/A


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices and KDB 558074 D01
DTS Meas Guidance v04.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




FCC Part 15.247                                                                           Page 4 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG180503003-00B


Measurement Uncertainty
            Parameter                                      Measurement Uncertainty
    Occupied Channel Bandwidth                                     ±5 %
    RF output power, conducted                                    ±0.61dB
  Power Spectral Density, conducted                               ±0.61 dB
                                          30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
    Unwanted Emissions, radiated
                                            6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
   Unwanted Emissions, conducted                                    ±1.5 dB
           Temperature                                                ±1℃
             Humidity                                                 ±5%
   DC and low frequency voltages                                     ±0.4%
            Duty Cycle                                                 1%
 AC Power Lines Conducted Emission                        3.12 dB (150 kHz to 30 MHz)


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 897218,the FCC Designation No. : CN1220.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D.




FCC Part 15.247                                                                            Page 5 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180503003-00B

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in engineering mode.
For Bluetooth LE mode, 40 channels are provided for testing:

                                    Frequency                                    Frequency
                  Channel                                     Channel
                                      (MHz)                                        (MHz)
                    0                  2402                     20                  2442
                    1                  2404                     …                    …
                    …                   …                       …                    …
                    …                   …                       …                     …
                     ..                 …                       38                   2478
                    19                 2440                     39                   2480

EUT was tested with channel 0, 19 and 39.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
No EUT software was used for testing, the test channels were switched by key in the test engineering
sample.

The duty cycle as below:

                             Ton                    Ton+off             Duty Cycle
                            (ms)                    (ms)                   (%)
                            100                      100                   100




FCC Part 15.247                                                                              Page 6 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RDG180503003-00B

                                                                       RBW 3 MHz
                                                                      * VBW 3 MHz
                        Ref    20.5 dBm          * Att   30 dB         SWT 100 ms
                        20    Offset   0.5 dB

                                                                                                   A
                        10
                                                                                                  SGL
               1 RM *
               CLRWR
                        0                                                                         LVL


                        -10



                        -20



                        -30

                                                                                                  3DB
                        -40



                        -50



                        -60



                        -70




                        Center 2.44 GHz                          10 ms/




              Date: 25.MAY.2018             13:10:05




Local Support Equipment List and Details

       Manufacturer                             Description                         Model                Serial Number
           TEKA                                  Adapter                   PS05A050K1000EU                     N/A


Support Cable List and Details

                                                                                      Length
Cable Description             Shielding Type             Ferrite Core                                   From                To
                                                                                       (m)
  USB CABLE                            No                        N0                    1.08             Adapter            EUT




FCC Part 15.247                                                                                                      Page 7 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG180503003-00B

Block Diagram of Test Setup




FCC Part 15.247                                                     Page 8 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG180503003-00B

SUMMARY OF TEST RESULTS

               FCC Rules                            Description of Test               Result

         §15.247 (i) & §1.1310 &
                                                       RF Exposure                  Compliance
                §2.1093
                   §15.203                      Antenna Requirement                 Compliance

               §15.207 (a)                  AC Line Conducted Emissions             Compliance
            §15.205, §15.209,
                                                    Spurious Emissions              Compliance
               §15.247(d)
             §15.247 (a)(2)                          6 dB Bandwidth                 Compliance

             §15.247(b)(3)                Maximum Conducted Output Power            Compliance

                  §15.247(d)          100 kHz Bandwidth of Frequency Band Edge      Compliance

                  §15.247(e)                    Power Spectral Density              Compliance




FCC Part 15.247                                                                           Page 9 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180503003-00B

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline.

According to KDB447498 D01 General RF Exposure Guidance v06:

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        • f(GHz) is the RF channel transmit frequency in GHz
        • Power and distance are rounded to the nearest mW and mm before calculation
        • The result is rounded to one decimal place for comparison
        • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


Measurement Result

The max conducted power including tune-up tolerance is -4 dBm (0.4 mW).
[(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)]
=0.4/5*(√2.480) = 0.1< 3.0

So the stand-alone SAR evaluation is not necessary.




FCC Part 15.247                                                                               Page 10 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG180503003-00B

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct
   antenna is employed with the unit.


Antenna Information And Connector Construction
The EUT has one internal PCB antenna arrangement for BT, and the antenna gain is 5.3 dBi, fulfill the
requirement of this section. Please refer to the EUT photos.

Result: Compliance.




FCC Part 15.247                                                                                 Page 11 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG180503003-00B

FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207(a)


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with a 120 V/60 Hz AC power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




FCC Part 15.247                                                                              Page 12 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG180503003-00B

Test Procedure

During the conducted emission test, the adapter was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial         Calibration   Calibration
      Manufacturer              Description           Model
                                                                    Number             Date        Due Date
           R&S               EMI Test Receiver      ESCS 30        830245/006       2017-12-11     2018-12-11
           R&S              Two-line V-network      ENV 216          101614         2017-12-08     2018-12-08
         Unknown               Coaxial Cable       C-NJNJ-50        C-0200-01       2017-09-05     2018-09-05
           R&S                    L.I.S.N           ESH2-Z5        892107/021       2017-09-25     2018-09-25
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




FCC Part 15.247                                                                                    Page 13 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RDG180503003-00B

Test Data
    Environmental Conditions

                          Temperature:               26.6 C
        Relative Humidity:                            57 %
                         ATM Pressure:           100.5 kPa

     The testing was performed by Sider Huang on 2018-05-16.

     Test Result: Compliance
     Test Mode: Charging

    AC120 V, 60 Hz, Line:


                         80

                         70

                                                                                                        Quasi-Peak Limit
                         60
                                                                                                           Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                          10

                          0
                          150k       300   400 500      800 1M       2M     3M     4M 5M 6     8 10M          20M     30M

                                                                 Frequency in Hz


    Frequency                    QuasiPeak           Bandwidth              Corr.      Margin       Limit
                                                                   Line                                             Comment
      (MHz)                       (dBμV)               (kHz)                (dB)        (dB)       (dBμV)
     0.241949                       41.0               9.000        L1      10.4        21.0         62.0           Compliance
     1.209904                      32.2                9.000        L1       9.8        23.8           56.0         Compliance
     1.259081                      34.1                9.000        L1       9.8        21.9           56.0         Compliance
     1.787792                      35.9                9.000        L1       9.7        20.1           56.0         Compliance
     4.957528                      35.8                9.000        L1       9.8        20.2           56.0         Compliance
     5.454959                      42.0                9.000        L1       9.8        18.0           60.0         Compliance

    Frequency                     Average            Bandwidth              Corr.      Margin       Limit
                                                                   Line                                             Comment
      (MHz)                       (dBμV)               (kHz)                (dB)        (dB)       (dBμV)
     0.372042                       20.3               9.000        L1      10.0        28.2         48.5           Compliance
     1.162648                      26.0                9.000        L1       9.8        20.0           46.0         Compliance
     1.209904                      25.2                9.000        L1       9.8        20.8           46.0         Compliance
     1.259081                      26.0                9.000        L1       9.8        20.0           46.0         Compliance
     4.957528                      20.1                9.000        L1       9.8        25.9           46.0         Compliance
     5.454959                      21.9                9.000        L1       9.8        28.1           50.0         Compliance

FCC Part 15.247                                                                                                       Page 14 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RDG180503003-00B

    AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                       Quasi-Peak Limit
                         60

                                                                                                          Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k       300   400 500      800 1M       2M     3M     4M 5M 6     8 10M          20M     30M
                                                                Frequency in Hz



    Frequency                   QuasiPeak           Bandwidth              Corr.      Margin       Limit
                                                                  Line                                             Comment
      (MHz)                      (dBμV)               (kHz)                (dB)        (dB)       (dBμV)
     0.154858                      43.1               9.000        N       11.1        22.6         65.7           Compliance
     0.171759                     42.1                9.000        N        10.9       22.8           64.9         Compliance
     0.180171                     40.4                9.000        N        10.8       24.1           64.5         Compliance
     3.841741                     38.3                9.000        N        9.8        17.7           56.0         Compliance
     9.995211                     48.4                9.000        N        9.9        11.6           60.0         Compliance
    10.484680                     47.7                9.000        N        9.9        12.3           60.0         Compliance

    Frequency                    Average            Bandwidth              Corr.      Margin       Limit
                                                                  Line                                             Comment
      (MHz)                      (dBμV)               (kHz)                (dB)        (dB)       (dBμV)
     0.175915                      26.4               9.000        N       10.8        28.3         54.7           Compliance
     0.192030                     22.4                9.000        N        10.7       31.5           53.9         Compliance
     0.541050                     25.0                9.000        N        9.9        21.0           46.0         Compliance
     1.162648                     25.3                9.000        N        9.8        20.7           46.0         Compliance
     1.259081                     28.2                9.000        N        9.8        17.8           46.0         Compliance
     3.841741                     32.5                9.000        N        9.8        13.5           46.0         Compliance




FCC Part 15.247                                                                                                      Page 15 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG180503003-00B

FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205

EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission tests were performed in the 3 meters chamber test site A for the range 30MHz to
1GHz and the 3 meters chamber B test site for above 1GHz, using the setup accordance with the ANSI
C63.10-2013. The specification used was the FCC 15.209, and FCC 15.247 limits.

The spacing between the peripherals was 10 cm.




FCC Part 15.247                                                                            Page 16 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG180503003-00B

EMI Test Receiver & Spectrum Analyzer Setup

The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

30MHz-1000MHz:

                      Measurement           RBW           Video B/W       IF B/W
                          QP               120 kHz         300 kHz        120kHz

1GHz- 25GHz:

                       Measurement           Duty cycle        RBW         Video B/W
                           PK                   Any            1MHz          3 MHz
                                               >98%            1MHz          10 Hz
                           Ave.
                                               <98%            1MHz            1/T

Note: T is minimum transmission duration


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




FCC Part 15.247                                                                             Page 17 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG180503003-00B

Test Equipment List and Details

                                                                       Serial       Calibration    Calibration
    Manufacturer           Description             Model
                                                                      Number           Date         Due Date
    Sunol Sciences         Antenna                  JB3              A060611-1      2017-11-10     2020-11-10
        R&S            EMI Test Receiver            ESCI              100224        2017-12-11     2018-12-11
         HP               Amplifier                8447D            2727A05902      2017-09-05     2018-09-05
       Agilent         Spectrum Analyzer        E4440A              SG43360054      2018-01-04     2019-01-04
     ETS-Lindgren        Horn Antenna             3115               000 527 35     2016-01-05     2019-01-04
                                             AFS42-00101800-
        MITEQ               Amplifier                                 2001271       2017-09-05     2018-09-05
                                                 25-S-42
      Ducommun                                                      1007726-01
                          Horn Antenna         ARH-4223-02                          2016-11-18     2019-11-18
     Technolagies                                                      1304
       Quinstar             Amplifier       QLW-18405536-JO        15964001001      2017-06-27     2018-06-27
                                            OBSF-2400-2483.5-
     E-Microwave        Band-stop Filters                          OE01601525       2017-06-16     2018-06-16
                                                   S
     Micro-tronics       High Pass Filter      HPM50111              S/N-G217       2017-06-16     2018-06-16
      Unknown             Coaxial Cable          C-NJNJ-50           C-0400-01      2017-09-05     2018-09-05
      Unknown             Coaxial Cable          C-NJNJ-50           C-0075-01      2017-09-05     2018-09-05
       Unknown            Coaxial Cable         C-NJNJ-50            C-1000-01      2017-09-05     2018-09-05
       Unknown            Coaxial Cable         C-SJSJ-50            C-0800-01      2017-09-05     2018-09-05
       Unknown            Coaxial Cable        C-2.4J2.4J-50         C-0700-02      2017-06-27     2018-06-27
         Farad            Test Software           EZ-EMC              V1.1.4.2         N/A            N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

     Environmental Conditions

              Temperature:            24.1~24.9 C
         Relative Humidity:             34~43 %
            ATM Pressure:            100.8~100.9 kPa

     * The testing was performed by Sunny Cen&Blake Yang on 2018-05-15 and 2018-05-17.

Test Result: Compliance

Test Mode: Transmitting




FCC Part 15.247                                                                                    Page 18 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG180503003-00B

1) 30MHz-1GHz(Low Channel was the worst):
Horizontal:




                  Receiver                     Correction     Cord.
   Frequency                                                               Limit        Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                               (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)      (dBuV/m)
     30.9700       27.69            QP            0.81        28.50        40.00         11.50
    428.6700       37.85            QP           -1.45        36.40        46.00         9.60
    503.3600       32.73            QP           -0.23        32.50        46.00         13.50
    572.2300       38.85            QP            0.85        39.70        46.00         6.30
    609.0900       33.47            QP            1.03        34.50        46.00         11.50
    644.9800       33.42            QP            2.28        35.70        46.00         10.30




FCC Part 15.247                                                                        Page 19 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG180503003-00B

Vertical:




                  Receiver                     Correction      Cord.
   Frequency                                                                Limit        Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)       (dBuV/m)

     52.3100        47.09           QP              -11.89    35.20         40.00         4.80
    428.6700        34.85           QP               -1.45    33.40         46.00         12.60
    500.4500        35.42           QP               -0.32    35.10         46.00         10.90
    575.1400        38.77           QP                0.93    39.70         46.00         6.30
    611.0300        35.64           QP                1.06    36.70         46.00         9.30
    644.0100        35.21           QP                2.29    37.50         46.00         8.50




FCC Part 15.247                                                                         Page 20 of 33


  Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG180503003-00B

 2) 1-25GHz:

                  Receiver             Rx Antenna      Cable Amplifier   Corrected
Frequency                                                                              Limit      Margin
            Reading    Detector       Polar Factor       loss    Gain    Amplitude
  (MHz)                                                                              (dBμV/m)      (dB)
            (dBμV) (PK/QP/AV)         (H/V) (dB/m)      (dB)     (dB)    (dBμV/m)
                                          Low Channel: 2402 MHz
 2402.00      58.65         PK          H     28.10     1.80      0.00     88.55         N/A        N/A
 2402.00      57.40         AV          H     28.10     1.80      0.00     87.30         N/A        N/A
 2402.00      57.16         PK          V     28.10     1.80      0.00     87.06         N/A        N/A
 2402.00      56.04         AV          V     28.10     1.80      0.00     85.94         N/A        N/A
 2390.00      25.45         PK          H     28.08     1.80      0.00     55.33        74.00      18.67
 2390.00      14.26         AV          H     28.08     1.80      0.00     44.14        54.00       9.86
 4804.00      52.12         PK          H     32.91     3.17     37.20     51.00        74.00      23.00
 4804.00      46.08         AV          H     32.91     3.17     37.20     44.96        54.00      9.04
 7206.00      47.22         PK          H     35.74     4.82     37.23     50.55        74.00      23.45
 7206.00      41.27         AV          H     35.74     4.82     37.23     44.60        54.00      9.40
                                         Middle Channel: 2440 MHz
 2440.00      57.38         PK          H     28.18     1.82      0.00     87.38         N/A        N/A
 2440.00      56.31         AV          H     28.18     1.82      0.00     86.31         N/A        N/A
 2440.00      56.41         PK          V     28.18     1.82      0.00     86.41         N/A        N/A
 2440.00      55.18         AV          V     28.18     1.82      0.00     85.18         N/A        N/A
 4880.00      52.74         PK          H     33.06     3.27     37.21     51.86        74.00      22.14
 4880.00      46.58         AV          H     33.06     3.27     37.21     45.70        54.00       8.30
 7320.00      45.97         PK          H     36.03     4.62     37.37     49.25        74.00      24.75
 7320.00      40.13         AV          H     36.03     4.62     37.37     43.41        54.00      10.59
                                          High Channel: 2480 MHz
 2480.00      56.85         PK          H     28.26     1.84      0.00     86.95         N/A        N/A
 2480.00      55.57         AV          H     28.26     1.84      0.00     85.67         N/A        N/A
 2480.00      55.37         PK          V     28.26     1.84      0.00     85.47         N/A        N/A
 2480.00      54.18         AV          V     28.26     1.84      0.00     84.28         N/A        N/A
 2483.50      26.52         PK          H     28.27     1.84      0.00     56.63        74.00      17.37
 2483.50      14.24         AV          H     28.27     1.84      0.00     44.35        54.00       9.65
 4960.00      52.99         PK          H     33.22     3.23     37.25     52.19        74.00      21.81
 4960.00      46.68         AV          H     33.22     3.23     37.25     45.88        54.00      8.12
 7440.00      46.62         PK          H     36.34     4.41     37.52     49.85        74.00      24.15
 7440.00      40.87         AV          H     36.34     4.41     37.52     44.10        54.00      9.90




  FCC Part 15.247                                                                        Page 21 of 33


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG180503003-00B

    Worst plots (Low Channel)
    Horizontal


Fundamental
Test with Band
Rejection Filter




     FCC Part 15.247                                                     Page 22 of 33


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG180503003-00B

    Vertical



Fundamental
Test with Band
Rejection Filter




     FCC Part 15.247                                                     Page 23 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG180503003-00B


FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH
Applicable Standard
According to FCC §15.247(a) (2)

Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure

a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3×RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
   maximum level measured in the fundamental emission.


                                EUT                                Signal Analyzer



Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer            Description            Model
                                                                  Number             Date         Due Date

         R&S            Spectrum Analyzer          FSP 38          100478         2017-12-08      2018-12-08

       Unknown            Coaxial Cable          C-SJ00-0010      C0010/01         Each time           /


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

            Temperature:              28.3 C
       Relative Humidity:              60 %
          ATM Pressure:              100.8 kPa

     The testing was performed by Kami Zhou on 2018-05-07.

      Test Result: Compliance.



FCC Part 15.247                                                                                    Page 24 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RDG180503003-00B

   Test Mode: Transmitting

  Test Result: Compliant. Please refer to the following table and plots.


                                               Frequency               6 dB Bandwidth              Limit
                          Channel
                                                 (MHz)                     (MHz)                  (MHz)
                             Low                     2402                      0.69                ≥0.5
                            Middle                   2440                      0.69                ≥0.5
                             High                    2480                      0.69                ≥0.5



                                                            Low Channel
                                                                * RBW 100 kHz   Delta 1 [T1 ]
                                                                * VBW 300 kHz               0.30 dB
                      Ref    10 dBm            * Att   20 dB      SWT 2.5 ms       692.000000000 kHz
                      10    Offset    0.5 dB                                    Marker 1 [T1 ]
                                                                                          -10.88 dBm
                                                                                     2.401604000 GHz   A
                      0

               1 PK            D1 -4.81 dBm
               MAXH                             1                         1
                      -10            D2 -10.81 dBm                                                     LVL


                      -20



                      -30



                      -40

                                                                                                       3DB
                      -50



                      -60



                      -70



                      -80


                      -90

                      Center 2.402 GHz                      200 kHz/                      Span 2 MHz




               Date: 7.MAY.2018          14:01:34




FCC Part 15.247                                                                                                Page 25 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RDG180503003-00B


                                                         Middle Channel
                                                               * RBW 100 kHz   Delta 1 [T1 ]
                                                               * VBW 300 kHz               0.03 dB
                      Ref    10 dBm            * Att   20 dB     SWT 2.5 ms       688.000000000 kHz
                      10    Offset    0.5 dB                                   Marker 1 [T1 ]
                                                                                         -11.39 dBm
                                                                                    2.439600000 GHz   A
                      0

               1 PK            D1 -5.37 dBm
               MAXH                             1                       1
                      -10
                                     D2 -11.37 dBm                                                    LVL


                      -20



                      -30



                      -40

                                                                                                      3DB
                      -50



                      -60



                      -70



                      -80


                      -90

                      Center 2.44 GHz                      200 kHz/                      Span 2 MHz




              Date: 7.MAY.2018           14:09:40


                                                           High Channel
                                                               * RBW 100 kHz   Delta 1 [T1 ]
                                                               * VBW 300 kHz              -0.24 dB
                      Ref    10 dBm            * Att   20 dB     SWT 2.5 ms       692.000000000 kHz
                      10    Offset    0.5 dB                                   Marker 1 [T1 ]
                                                                                         -11.57 dBm
                                                                                    2.479588000 GHz   A
                      0

               1 PK            D1 -5.66 dBm
               MAXH                            1                        1
                      -10
                                     D2 -11.66 dBm                                                    LVL


                      -20



                      -30



                      -40

                                                                                                      3DB
                      -50



                      -60



                      -70



                      -80


                      -90

                      Center 2.48 GHz                      200 kHz/                      Span 2 MHz




              Date: 7.MAY.2018           14:12:18




FCC Part 15.247                                                                                               Page 26 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG180503003-00B

FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure
1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test
   equipment.
3. Add a correction factor to the display.
4. Set the power Meter to test Peak output power, record the result as peak power.
5. Set the power meter to test average output power, record the result as average power.


                                                                         Power
                                EUT                                      Meter



Test Equipment List and Details

                                                                   Serial       Calibration     Calibration
     Manufacturer            Description           Model
                                                                  Number           Date          Due Date
                        USB Wideband Power
         Agilent                                  U2022XA       MY5417006        2017-12-11      2018-12-11
                             Sensor
        Unknown             Coaxial Cable       C-SJ00-0010       C0010/01       Each time            /


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).




FCC Part 15.247                                                                                    Page 27 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG180503003-00B

Test Data
     Environmental Conditions

            Temperature:            28.3 C
       Relative Humidity:            60 %
          ATM Pressure:            100.8 kPa

     The testing was performed by Kami Zhou on 2018-05-07.

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table.

                                                        Max Peak
                                      Frequency      Conducted Output    Limit
                       Channel
                                        (MHz)             Power         (dBm)
                                                          (dBm)
                         Low             2402              -4.86          30
                        Middle           2440              -5.29          30
                         High            2480              -5.75          30




FCC Part 15.247                                                                         Page 28 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG180503003-00B

FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If
the transmitter complies with the conducted power limits based on the use of RMS averaging over a time
interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph
shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not
required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer            Description            Model
                                                                  Number             Date         Due Date

         R&S            Spectrum Analyzer          FSP 38          100478         2017-12-08      2018-12-08

       Unknown            Coaxial Cable          C-SJ00-0010      C0010/01         Each time           /


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

            Temperature:              28.3 C
       Relative Humidity:              60 %
          ATM Pressure:              100.8 kPa

     The testing was performed by Kami Zhou on 2018-05-07.




FCC Part 15.247                                                                                    Page 29 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                Report No.: RDG180503003-00B

Test mode: Transmitting
Test Result: Compliance. Please refer to following plots.
                                                       Band Edge, Left Side
                                                                 * RBW 100 kHz   Marker 2 [T1 ]
                                                                 * VBW 300 kHz             -36.95 dBm
                      Ref    10 dBm            * Att    20 dB     SWT 2.5 ms          2.399184000 GHz
                      10    Offset    0.5 dB                                     Marker 1 [T1 ]
                                                                                             -5.15 dBm
                                                                                       2.402192000 GHz   A
                      0
                                                                                     1
               1 PK
               MAXH
                      -10
                                                                                                         LVL


                      -20
                      -25.15dBm

                      -30
                                                        2

                      -40

                                                                                                         3DB
                      -50



                      -60



                      -70



                      -80


                      -90

                      Center 2.4 GHz                        800 kHz/                       Span 8 MHz




               Date: 7.MAY.2018          14:06:16


                                                       Band Edge, Right Side
                                                                 * RBW 100 kHz   Marker 2 [T1 ]
                                                                 * VBW 300 kHz             -46.62 dBm
                      Ref    10 dBm            * Att    20 dB     SWT 2.5 ms          2.485712000 GHz
                      10    Offset    0.5 dB                                     Marker 1 [T1 ]
                                                            -26.04dBm                       -6.04 dBm
                                                                                      2.479664000 GHz    A
                      0
                                         1
               1 PK
               MAXH
                      -10
                                                                                                         LVL


                      -20



                      -30



                      -40
                                                                           2
                                                                                                         3DB
                      -50



                      -60



                      -70



                      -80


                      -90

                      Center 2.4835 GHz                     1.4 MHz/                      Span 14 MHz




               Date: 7.MAY.2018          14:14:18




FCC Part 15.247                                                                                                  Page 30 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG180503003-00B

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
According to FCC§15.247(e):For digitally modulated systems, the power spectral density conducted from
the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
interval of continuous transmission. This power spectral density shall be determined in accordance with
the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and
   connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one
   measured frequency within its operating range, and make sure the instrument is operated in its linear
   range.
3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth.
4. Use the peak marker function to determine the maximum amplitude level.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer            Description            Model
                                                                  Number             Date         Due Date

         R&S            Spectrum Analyzer          FSP 38          100478         2017-12-08      2018-12-08

       Unknown            Coaxial Cable          C-SJ00-0010      C0010/01         Each time           /


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

            Temperature:              28.3 C
       Relative Humidity:              60 %
          ATM Pressure:              100.8 kPa

     The testing was performed by Kami Zhou on 2018-05-07.




FCC Part 15.247                                                                                    Page 31 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RDG180503003-00B

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots


                                                    Frequency               PSD                 Limit
                              Channel
                                                      (MHz)              (dBm/3kHz)          (dBm/3kHz)
                                Low                      2402               -16.38                 ≤8
                               Middle                    2440               -17.02                 ≤8
                               High                      2480               -17.15                 ≤8



                                            Power Spectral Density, Low Channel
                                                                 * RBW 3 kHz    Marker 1 [T1 ]
                                                                 * VBW 10 kHz             -16.38 dBm
                        Ref    10 dBm            * Att   20 dB     SWT 115 ms        2.402051750 GHz
                        10    Offset    0.5 dB

                                                                                                       A
                        0

                 1 PK
                 MAXH
                        -10
                                                                                                       LVL
                                                                   1

                        -20



                        -30



                        -40

                                                                                                       3DB
                        -50



                        -60



                        -70



                        -80


                        -90

                        Center 2.402 GHz                    103.5 kHz/                Span 1.035 MHz




                 Date: 7.MAY.2018          14:05:53




FCC Part 15.247                                                                                                Page 32 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                               Report No.: RDG180503003-00B


                                        Power Spectral Density, Middle Channel
                                                                * RBW 3 kHz      Marker 1 [T1 ]
                                                                * VBW 10 kHz               -17.02 dBm
                      Ref    10 dBm             * Att   20 dB       SWT 115 ms        2.440022770 GHz
                      10    Offset    0.5 dB

                                                                                                        A
                      0

               1 PK
               MAXH
                      -10
                                                                                                        LVL
                                                                1

                      -20



                      -30



                      -40

                                                                                                        3DB
                      -50



                      -60



                      -70



                      -80


                      -90

                      Center 2.44 GHz                      103.5 kHz/                  Span 1.035 MHz




              Date: 7.MAY.2018           14:10:56


                                         Power Spectral Density, High Channel
                                                                * RBW 3 kHz      Marker 1 [T1 ]
                                                                * VBW 10 kHz               -17.15 dBm
                      Ref    10 dBm             * Att   20 dB       SWT 115 ms        2.480012420 GHz
                      10    Offset    0.5 dB

                                                                                                        A
                      0

               1 PK
               MAXH
                      -10
                                                                                                        LVL
                                                                1

                      -20



                      -30



                      -40

                                                                                                        3DB
                      -50



                      -60



                      -70



                      -80


                      -90

                      Center 2.48 GHz                      103.5 kHz/                  Span 1.035 MHz




              Date: 7.MAY.2018           14:13:48



                                               ***** END OF REPORT *****


FCC Part 15.247                                                                                                 Page 33 of 33



Document Created: 2019-09-03 19:45:13
Document Modified: 2019-09-03 19:45:13

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC