Test reports

FCC ID: 2ABY9-GRAVITY-2

Test Report

Download: PDF
FCCID_4392186

                                          Page 1 of 20            Report No.: HK1907231828-1E




                         FCC TEST REPORT



                                 Test report
                                 On Behalf of
                     Adam Elements International Co., LTD.
                                     For
                  GRAVITY 2 10W Wireless Charging Power Bank
                             Model No.: GRAVITY 2

                                  FCC ID: 2ABY9-GRAVITY-2




 Prepared for :   Adam Elements International Co., LTD.
                  10F.-3, No.54, Songjiang Rd., Zhongshan Dist., Taipei City, 104, Taiwan




 Prepared By :    Shenzhen HUAK Testing Technology Co., Ltd.
                  1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street,
                  Bao'an District, Shenzhen City, China




Date of Test:     July 23, 2019 ~ July 30, 2019
Date of Report:   July 30, 2019
Report Number:    HK1907231828-1E


                                                                 Page 2 of 20             Report No.: HK1907231828-1E



                                         TEST RESULT CERTIFICATION

Applicant’s name ................. : Adam Elements International Co., LTD.
                                                 10F.-3, No.54, Songjiang Rd., Zhongshan Dist., Taipei City,
Address ................................. :
                                                 104, Taiwan
Manufacture's Name ............ : Adam Elements International Co., LTD.
                                                 10F.-3, No.54, Songjiang Rd., Zhongshan Dist., Taipei City,
Address ................................. :
                                                 104, Taiwan
Product description
Trade Mark:                                      ADAM elements
Product name ........................... : GRAVITY 2 10W Wireless Charging Power Bank
Model and/or type reference : GRAVITY 2
                                                 FCC Rules and Regulations Part 15 Subpart C (Section 15.209),
Standards ............................. :
                                                 ANSI C63.10: 2013
This publication may be reproduced in whole or in part for non-commercial purposes as long as
the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source
of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced
material due to its placement and context.
Date of Test ............................................ :
Date (s) of performance of tests ............. :                July 23, 2019 ~ July 30, 2019
Date of Issue ........................................... :     July 30, 2019
Test Result ............................................... :   Pass




                          Testing Engineer                  :


                                                                            (Gary Qian)

                          Technical Manager                 :

                                                                             (Eden Hu)


                          Authorized Signatory :


                                                                           (Jason Zhou)


                                        Page 3 of 20   Report No.: HK1907231828-1E




                             Table of Contents                          Page

1 . TEST SUMMARY                                                             4
     1.1 TEST PROCEDURES AND RESULTS                                         4
     1.2 TEST FACILITY                                                       4
     1.3 MEASUREMENT UNCERTAINTY                                             4
2. GENERAL INFORMATION                                                       5
     2.1 General Description of EUT                                          5
     2.2. Carrier Frequency of Channels                                      6
     2.3 Operation of EUT during testing                                     6
     2.4 Description of Test Setup                                           6
     2.5 Measurement Instruments List                                        7
3.   CONDUCTED EMISSION TEST                                                 8
     3.1 Block Diagram of Test Setup                                         8
     3.2 Conducted Power Line Emission Limit                                 8
     3.3 Test Procedure                                                      8
     3.4 Test Result                                                         8
4.   Occupied Bandwidth                                                    11
     4.1 Block Diagram of Test Setup                                       11
     4.2 Rules and specifications                                          11
     4.3 Test Procedure                                                    11
     4.4 Test Result                                                       11
5.   RADIA TED EMISSIONS                                                   13
     5.1 Block Diagram of Test Setup                                       13
     5.2 Rules and specifications                                          14
     5.3 Test Procedure                                                    15
     5.4   Test Result                                                     15
6 ANTENNA REQUIREMENT                                                      18
7. PHOTOGRAPH OF TEST                                                      19
     7.1 Radiated Emission                                                 19
     7.2 Conducted Emission                                                20


                                       Page 4 of 20             Report No.: HK1907231828-1E



1. TEST SUMMARY

1.1 TEST PROCEDURES AND RESULTS

  DESCRIPTION OF TEST                                       RESULT
  CONDUCTED EMISSIONS TEST                                 COMPLIANT
  RADIATED EMISSION TEST                                   COMPLIANT
  OCCUPIED BANDWIDTH MEASUREMENT                           COMPLIANT
  ANTENNA REQUIREMENT                                      COMPLIANT




1.2 TEST FACILITY

 Test Firm      : Shenzhen HUAK Testing Technology Co., Ltd.


 Address          1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai
                  Street, Bao'an District, Shenzhen City, China




1.3 MEASUREMENT UNCERTAINTY

  Measurement Uncertainty
  Conducted Emission Expanded Uncertainty                   =    2.23dB, k=2
  Radiated emission expanded uncertainty(9kHz-30MHz)        =    3.08dB, k=2
  Radiated emission expanded uncertainty(30MHz-1000MHz)     =    4.42dB, k=2
  Radiated emission expanded uncertainty(Above 1GHz)        =    4.06dB, k=2


                                         Page 5 of 20         Report No.: HK1907231828-1E


 2. GENERAL INFORMATION

  2.1 General Description of EUT


Equipment             GRAVITY 2 10W Wireless Charging Power Bank
Model Name            GRAVITY 2
Serial No.            N/A
Model Difference      N/A
Trade Mark            ADAM elements
FCC ID                2ABY9-GRAVITY-2
Antenna Type          Coil Antenna
Antenna Gain          1dBi
Operation frequency   110-205KHz
Number of Channels    1
Modulation Type       FSK
Power Source          DC voltage
                      Built-in battery:DC3.7V
                      Micro-B Input voltage: DC5V 2.1A or DC9V 2A
                      USB-C Input voltage: DC5V 2.5A or DC9V 2A
Power Rating
                      USB-A Output voltage: DC 5V 2.4A or DC9V 2A or 12V 1.5A
                      USB-c Output voltage: DC 5V 3A or DC9V 2A or 12V 1.5A
                      Wireless Output voltage: DC5V 1A or DC9V 1.1A


                                            Page 6 of 20    Report No.: HK1907231828-1E

2.2. Carrier Frequency of Channels
Operation Frequency each of channel
Channel       Frequency
1             125KHz



    2.3 Operation of EUT during testing
                     Operating Mode
                     The mode is used: Transmitting mode

    2.4 Description of Test Setup

        Operation of EUT during testing




                 AC 120V/60Hz               Adapter            EUT




    Setup: Transmission mode
                                                           Mobile
    ●   Adapter information                                phones
        Model: UP0920
        Input: AC100-240V~, 50/60Hz, 0.5A
        Output: 5VDC, 2A / 9VDC,2A

    ● Mobile phones information
      Model: S6
      Input: 5VDC


                                             Page 7 of 20         Report No.: HK1907231828-1E

2.5 Measurement Instruments List
                                                                                           Cal.
Item      Equipment         Manufacturer      Model No.     Serial No.     Last Cal.
                                                                                         Interval
            L.I.S.N.
 1.     Artificial Mains        R&S            ENV216       HKE-002      Dec. 27, 2018   1 Year
           Network
 2.        Receiver             R&S             ESCI 7      HKE-010      Dec. 27, 2018   1 Year
         RF automatic
 3.                           Tonscend         JS0806-2     HKE-060      Dec. 27, 2018   1 Year
          control unit
 4.    Spectrum analyzer        R&S             FSP40       HKE-025      Dec. 27, 2018   1 Year
 5.    Spectrum analyzer       Agilent         N9020A       HKE-048      Dec. 27, 2018   1 Year
 6.       Preamplifier      Schwarzbeck       BBV 9743      HKE-006      Dec. 27, 2018   1 Year
 7.    EMI Test Receiver   Rohde & Schwarz      ESCI 7      HKE-010      Dec. 27, 2018   1 Year
       Bilog Broadband
 8.                         Schwarzbeck       VULB9163      HKE-012      Dec. 27, 2018   1 Year
           Antenna
                                              FMZB 1519
 9.      Loop Antenna        Schwarzbeck                    HKE-014      Dec. 27, 2018   1 Year
                                                 B
10.      Horn Antenna       Schewarzbeck        9120D       HKE-013      Dec. 27, 2018   1 Year
                                             EMC051845
11.      Pre-amplifier          EMCI                        HKE-015      Dec. 27, 2018   1 Year
                                                SE
12.      Pre-amplifier         Agilent          83051A      HKE-016      Dec. 27, 2018   1 Year
       EMI Test Software                       JS1120-B
13.                           Tonscend                      HKE-083      Dec. 27, 2018    N/A
           EZ-EMC                               Version
14.      Power Sensor          Agilent         E9300A       HKE-086      Dec. 27, 2018   1 Year
15.    Spectrum analyzer       Agilent         N9020A       HKE-048      Dec. 27, 2018   1 Year
16.     Signal generator       Agilent         N5182A       HKE-029      Dec. 27, 2018   1 Year
17.    Signal Generator        Agilent          83630A      HKE-028      Dec. 27, 2018   1 Year
18.     Shielded room        Shiel Hong          4*3*3      HKE-039      Dec. 27, 2018   3 Year


                                                 Page 8 of 20             Report No.: HK1907231828-1E

3.   CONDUCTED EMISSION TEST

 3.1 Block Diagram of Test Setup




3.2 Conducted Power Line Emission Limit

According to FCC Part 15.207(a)




* Decreasing linearly with the logarithm of the frequency
For intentional device, according to §15.207Line Conducted Emission Limit is same as
above table.
3.3 Test Procedure
     1, The equipment was set up as per the test configuration to simulate typical actual usage per the
        user’s manual. The EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and
        is placed on the ground plane as per ANSI C63.10.
     2, Support equipment, if needed, was placed as per ANSI C63.10.
     3, All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
     4, If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received
        AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied power
        source and was grounded to the ground plane.
     5, All support equipments received AC power from a second LISN, if any.
     6, The EUT test program was started. Emissions were measured on each current carrying line of the
        EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has
        two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with
        Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan
        had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
     7, Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes

3.4 Test Result
       PASS


                                             Page 9 of 20          Report No.: HK1907231828-1E


      Remark: We tested all mode, the worst(Wireless Output voltage DC9V ) case was recorded.
                           Please refer to following diagram for individual



Test Specification: Line




     Remark: Margin = Limit – Level
     Correction factor = Cable lose + LISN insertion loss
     Level=Test receiver reading + correction factor


                                           Page 10 of 20   Report No.: HK1907231828-1E




Test Specification: Neutral




   Remark: Margin = Limit – Level
   Correction factor = Cable lose + LISN insertion loss
   Level=Test receiver reading + correction factor


                                                 Page 11 of 20               Report No.: HK1907231828-1E


4.   Occupied Bandwidth

 4.1 Block Diagram of Test Setup




4.2 Rules and specifications
     CFR 47 Part 15.215(c)
     ANSI C63.10-2013
4.3 Test Procedure
Intentional radiators operating under the alternative provisions to the general emission limits, as contained
in §§15.217 through 15.257 and in subpart E of this part, must be designed to ensure that 20dB bandwidth
of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which
the equip compliance with the 20dB attenuation specification may base on measurement at the intentional
radiator’s antenna output terminal unless the intentional radiator uses a permanently attached antenna, in
which case compliance shall be.deomonstrated by measuring the radiated emissions.




4.4 Test Result
         PASS

                      Freq       20dB Bandwidth
      Mode                                                  Limit (kHz)           Conclusion
                     (KHz)           (KHz)
     Tx Mode          125               2.701                     /                  PASS


Page 12 of 20   Report No.: HK1907231828-1E


                                   Page 13 of 20   Report No.: HK1907231828-1E


5.   RADIA TED EMISSIONS

 5.1 Block Diagram of Test Setup


                                                Page 14 of 20               Report No.: HK1907231828-1E

5.2 Rules and specifications
    CFR 47 Part 15, section 15.205
    Only spurious emissions are permitted in any of the frequency bands listed the tables in these sections.




    CFR 47 Part 15, section 15.209
    The emissions from an intentional radiator shall not exceed the limits in the tables in these sections using an
    average detector




    CFR 47 Part 15, section 15.35
    When average radiated emission measurements are specified, the limit on the peak level of the radio
    Frequency emission is 20dB above the maximum permitted average emission limit.

                             Transmitter Spurious Emissions 9KHz-30MHz
                           9-150KHz                    150-490KHz                 490KHz-30MHz
   Resolution Bandwidth    200Hz                       9KHz                       9KHz
   Video Bandwidth         2KHz                        100KHz                     100KHz
   Detector                Peak                        Peak                       Peak
   Trace Mode              Max Hold                    Max Hold                   Max Hold
   Sweep Time              Auto                        Auto                       Auto


                                              Page 15 of 20            Report No.: HK1907231828-1E




5.3 Test Procedure
Measurement distance 3m
For the measurement range up to 30MHz in the following plots the field strength result from 3m
Distance measurement are extrapolated to 300m and 30m distance respectively, by 40dB/decade,
According to part 15.31(f)(2), per antenna factor scaling.
Measurements below 1000MHz are performed with a peak detector and compared to average limits,
Measurements with an average detector are not required.
Note:
     For battery operated equipment, the equipment tests shall be performed using a new battery.

5.4    Test Result

          PASS


   For 9KHz-30MHz
Remark: We tested 3 ANTENNAS and the voltage in 5VDC and 9VDC, the worst case ANTENNA 3 (5VDC)
                                              was recorded.
                               Please refer to following diagram for individual

               Detector
                                          Factor
      Freq.     Mode        Reading                  Actual FS Limits 3m        Margin
                                           (dB)
      (MHz)    (PK/QP)      (dBuV)                   (dBuV/m) (dBuV/m)         (dBuV/m)

      0.110      Peak         21.44         24.8        46.24       126.77        80.53
      0.125      Peak         46.18         24.8        70.98       125.67        54.69
      0.486      Peak         25.54        25.03        50.57       113.71        63.14
      0.500      Peak         26.17        25.03        51.2        113.62        62.42


                                              Page 16 of 20         Report No.: HK1907231828-1E


For 30MHz-1GHz

      Remark: We tested all mode, the worst(Wireless Output voltage DC9V ) case was recorded.
                           Please refer to following diagram for individual



Antenna polarity: H




   Remark: Margin = Limit – Level
   Correction factor = Cable lose + LISN insertion loss
   Level=Test receiver reading + correction factor


                                              Page 17 of 20   Report No.: HK1907231828-1E



Antenna polarity: V




   Remark: Margin = Limit – Level
   Correction factor = Cable lose + LISN insertion loss
   Level=Test receiver reading + correction factor


                                               Page 18 of 20              Report No.: HK1907231828-1E




6 ANTENNA REQUIREMENT

 Standard Applicable
 For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be
 designed to ensure that no antenna other than that furnished by the responsible party shall be used
 with the device.

 Refer to statement below for compliance.
 The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
 standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
 intentional radiators that must be professionally installed.

 Antenna Connected Construction
 The antenna used in this product is a Coil Antenna, The directional gains of antenna used for
 transmitting is 1dBi.

 ANTENNA


                          Page 19 of 20   Report No.: HK1907231828-1E


7. PHOTOGRAPH OF TEST

  7.1 Radiated Emission


                                          Page 20 of 20              Report No.: HK1907231828-1E


 7.2 Conducted Emission




8. PHOTOGRAPH OF TEST

Reference to the reporter : ANNEX A of external photos and ANNEX B of internal photos



                              ---------End of test report---------