RF Exposure

FCC ID: 2ABY6-MOBC150RPA

RF Exposure Info

Download: PDF
FCCID_4087752

Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM180827050-00C

FCC §15.407 (f) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.407(f)and subpart §1.1310, systems operating under the provisions of this
section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy
level in excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                         (B) Limits for General Population/Uncontrolled Exposure
Frequency Range        Electric Field       Magnetic Field        Power Density                Averaging Time
     (MHz)            Strength (V/m)        Strength (A/m)           (mW/cm2)                    (minutes)
    0.3–1.34                614                   1.63                 *(100)                        30
    1.34–30                824/f                 2.19/f               *(180/f²)                      30
    30–300                 27.5                  0.073                   0.2                         30
   300–1500                  /                      /                  f/1500                        30
 1500–100,000                /                      /                    1.0                         30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculation formula:

Prediction of power density at the distance of the applicable MPE limit
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


Calculated Data:

                                             Max. Target Power
                                                                    Evaluation        Power        MPE
       Frequency        Antenna Gain              including
                                                                     Distance        Density       Limit
         Range                                   Tolerance
                                                                      (cm)           (W/m2)       (W/m2)
                      (dBi)    (numeric)     (dBm)       (mW)
       5150-5850       4.5        2.82         18        63.10         20.00          0.035         1.0


Result: Compliance, The device meets MPE requirement for Devices Used by the General Public
(Uncontrolled Environment) at distance ≥20 cm.