Test Report

FCC ID: 2ABY6-MOB55A

Test Report

Download: PDF
FCCID_4312647

                                           FCC PART 15.247
                                               TEST REPORT

                                                              For

                                                 Ingenico Inc.
                            101 Federal Street, Suite 700, Boston, MA,02110 United States



                                       FCC ID: 2ABY6-MOB55A


            Report Type:                                 Product Name:
            Original Report                              Mobile Pay ment Terminal


                  Report Number:           RXM190322051-00C


                      Report Date:         2019-04-23
                                           Jerry Zhang

                                           EMC Manager
                     Reviewed By:

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                         Report No.: RXM190322051-00C




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................7
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................8
SUMMARY OF TEST RESULTS ...............................................................................................................................9
FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE..........................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA INFORMATION AND CONNECTOR CONSTRUCTION.....................................................................................11
FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS ......................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST DATA ................................................................................................................................................................14
FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS .................................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST DATA ................................................................................................................................................................18
FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH .............................................................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................24
FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER ......................................................27
  APPLICABLE STANDARD ............................................................................................................................................27
  TEST PROCEDURE ......................................................................................................................................................27
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................27

                                                                                                                                                            Page 2 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                      Report No.: RXM190322051-00C
 TEST DATA ................................................................................................................................................................27
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................29
  APPLICABLE STANDARD ............................................................................................................................................29
  TEST PROCEDURE ......................................................................................................................................................29
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................29
  TEST DATA ................................................................................................................................................................29
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................31
  APPLICABLE STANDARD ............................................................................................................................................31
  TEST PROCEDURE ......................................................................................................................................................31
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................31
  TEST DATA ................................................................................................................................................................31




                                                                                                                                                           Page 3 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM190322051-00C

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                              EUT Name:      Mobile Payment Terminal
                              EUT Model:     Moby/5500
                                  FCC ID:    2ABY6-MOB55A
                    Operation Frequency:     2402-2480MHz
               Output Power (Conducted):     6.42 dBm
                        Modulation Type:     GFSK
                     Rated Input Voltage:    DC 3.7V from battery or DC5V from USB port
                      External Dimension:    77mm(L)*54mm(W)*16mm(H)
                           Serial Number:    190322051
                      EUT Received Date:     2019.3.25


Objective
This report is prepared on behalf of Ingenico Inc. in accordance with Part 2, Subpart J, Part 15, Subparts
A, and C of the Federal Communications Commission’s rules.

The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15-
Subpart C, section 15.203, 15.205,15.207, 15.209, 15.247 rules.


Related Submittal(s)/Grant(s)
FCC Part C DSS and DXX submissions with FCC ID: 2ABY6-MOB55A.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices and KDB 558074 D01
15.247 Meas Guidance v05r01.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




                                                                                                Page 4 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RXM190322051-00C

Measurement Uncertainty
                   Parameter                               Measurement Uncertainty
           Occupied Channel Bandwidth                                ±5 %
           RF output power, conducted                               ±0.61dB
         Power Spectral Density, conducted                          ±0.61 dB
                                                    30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,
           Unwanted Emissions, radiated               1G~6GHz: 4.98 dB, 6G~18GHz: 5.89 dB,
                                                      18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
          Unwanted Emissions, conducted                             ±1.5 dB
                  Temperature                                         ±1℃
                    Humidity                                          ±5%
          DC and low frequency voltages                              ±0.4%
                   Duty Cycle                                          1%
        AC Power Lines Conducted Emission                 3.12 dB (150 kHz to 30 MHz)


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier: CN0022.




                                                                                              Page 5 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM190322051-00C

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in engineering mode.
For Bluetooth LE mode, 40 channels are provided for testing:

                                    Frequency                                     Frequency
                Channel                                       Channel
                                      (MHz)                                         (MHz)
                   0                   2402                     20                   2442
                   1                   2404                     …                     …
                   …                    …                       …                     …
                   …                    …                       …                     …
                    ..                 …                        38                   2478
                   19                 2440                      39                   2480

EUT was tested with channel 0, 19 and 39.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
Test software: ' RTLBTAPP ' was used in test, the system configured maximum power level as default
setting.

The duty cycle as below:

                            Ton                     Ton+off             Duty Cycle
                           (ms)                     (ms)                   (%)
                           0.135                    0.625                  21.6




                                                                                              Page 6 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                    Report No.: RXM190322051-00C




Support Equipment List and Details


      Manufacturer             Description              Model             Serial Number
         HUAWEI                  Adapter            KA25-0501000US              N/A


Support Cable List and Details

                        Shielding                        Length
   Cable Description                  Ferrite Core                     From               To
                          Type                            (m)
      USB Cable            Yes               No            1          Adapter             EUT




                                                                                          Page 7 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RXM190322051-00C

Block Diagram of Test Setup




                                                                      Page 8 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM190322051-00C

SUMMARY OF TEST RESULTS

               FCC Rules                            Description of Test               Result

       FCC §15.247 (i) & §1.1310 &
                                                       RF Exposure                  Compliance
                §2.1093
                §15.203                         Antenna Requirement                 Compliance

               §15.207 (a)                  AC Line Conducted Emissions             Compliance
            §15.205, §15.209,
                                                    Spurious Emissions              Compliance
               §15.247(d)
             §15.247 (a)(2)                          6 dB Bandwidth                 Compliance

             §15.247(b)(3)                Maximum Conducted Output Power            Compliance

               §15.247(d)             100 kHz Bandwidth of Frequency Band Edge      Compliance

               §15.247(e)                       Power Spectral Density              Compliance




                                                                                               Page 9 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM190322051-00C

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline.

According to KDB447498 D01 General RF Exposure Guidance v06:

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        • f(GHz) is the RF channel transmit frequency in GHz
        • Power and distance are rounded to the nearest mW and mm before calculation
        • The result is rounded to one decimal place for comparison
        • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.

When an antenna qualifies for the standalone SAR test exclusion of 4.3.1 and also transmits
simultaneously with other antennas, the standalone SAR value must be estimated according to the
following to determine the simultaneous transmission SAR test exclusion criteria: [(max. power of channel,
including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)/x] W/kg, for test
separation distances ≤ 50 mm; where x = 7.5 for 1-g SAR and x = 18.75 for 10-g SAR.


Measurement Result

The max conducted power including tune-up tolerance is 6.5 dBm (4.47 mW).
[(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)]
=4.47/5*(√2.480) = 1.4< 3.0

So the SAR test is not necessary.




                                                                                               Page 10 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RXM190322051-00C

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct
   antenna is employed with the unit.


Antenna Information And Connector Construction
The EUT has one PCB antenna arrangement for BT, and the antenna gain is 0.5 dBi, fulfill the requirement
of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 11 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RXM190322051-00C

FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207(a)


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with a 120 V/60 Hz AC power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                              Page 12 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RXM190322051-00C

Test Procedure

During the conducted emission test, the adapter was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial        Calibration    Calibration
      Manufacturer              Description           Model
                                                                    Number            Date         Due Date
           R&S               EMI Test Receiver      ESCS 30        830245/006      2018-12-11      2019-12-11
         Unknown               Coaxial Cable       C-NJNJ-50        C-0200-01      2018-09-05      2019-09-05
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614        2018-12-08      2019-12-08

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 13 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                Report No.: RXM190322051-00C

Test Data
    Environmental Conditions

                          Temperature:                  26.7 C
        Relative Humidity:                               67 %
                         ATM Pressure:                 101.4 kPa

     The testing was performed by Lily Xie on 2019-03-29.

     Test Mode: BLE low channel transmitting-worst case

    AC120 V, 60 Hz, Line:


                         80

                         70
                                                                                                          Quasi-Peak Limit
                         60
                                                                                                             Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                          10

                          0
                          150k       300   400 500      800 1M         2M     3M     4M 5M 6     8 10M          20M     30M
                                                                   Frequency in Hz



    Frequency                    QuasiPeak           Bandwidth                Corr.      Margin       Limit
                                                                     Line                                             Comment
      (MHz)                       (dBμV)               (kHz)                  (dB)        (dB)       (dBμV)
     0.150000                       40.4               9.000          L1      11.2        25.6         66.0           Compliance
     0.264490                      28.8                9.000          L1       10.3       32.5           61.3         Compliance
     0.382209                      25.7                9.000          L1       10.0       32.5           58.2         Compliance
     0.490157                      25.3                9.000          L1       9.9        30.9           56.2         Compliance
     0.814189                      21.1                9.000          L1       9.8        34.9           56.0         Compliance
     3.515338                      17.5                9.000          L1       9.8        38.5           56.0         Compliance

    Frequency                     Average            Bandwidth                Corr.      Margin       Limit
                                                                     Line                                             Comment
      (MHz)                       (dBμV)               (kHz)                  (dB)        (dB)       (dBμV)
     0.167350                       20.1               9.000          L1      10.9        34.9         55.0           Compliance
     0.382209                      12.5                9.000          L1       10.0       35.7           48.2         Compliance
     0.471031                      14.9                9.000          L1       9.9        31.6           46.5         Compliance
     1.130656                      13.2                9.000          L1       9.8        32.8           46.0         Compliance
     1.286792                      13.5                9.000          L1       9.8        32.5           46.0         Compliance
     4.163230                       8.1                9.000          L1       9.8        37.9           46.0         Compliance


                                                                                                                         Page 14 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RXM190322051-00C

    AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                       Quasi-Peak Limit
                         60
                                                                                                          Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k       300   400 500      800 1M       2M     3M     4M 5M 6     8 10M          20M     30M
                                                                Frequency in Hz



    Frequency                   QuasiPeak           Bandwidth              Corr.      Margin       Limit
                                                                  Line                                             Comment
      (MHz)                      (dBμV)               (kHz)                (dB)        (dB)       (dBμV)
     0.150000                      43.2               9.000        N       11.2        22.8         66.0           Compliance
     0.259279                     30.8                9.000        N        10.3       30.7           61.5         Compliance
     0.471031                     34.6                9.000        N        9.9        21.9           56.5         Compliance
     0.552321                     26.3                9.000        N        9.8        29.7           56.0         Compliance
     0.814189                     29.4                9.000        N        9.8        26.6           56.0         Compliance
     2.116299                     23.7                9.000        N        9.8        32.3           56.0         Compliance

    Frequency                    Average            Bandwidth              Corr.      Margin       Limit
                                                                  Line                                             Comment
      (MHz)                      (dBμV)               (kHz)                (dB)        (dB)       (dBμV)
     0.430682                      28.4               9.000        N        9.9        18.8         47.2           Compliance
     0.461750                     32.0                9.000        N        9.9        14.7           46.7         Compliance
     0.557844                     25.0                9.000        N        9.8        21.0           46.0         Compliance
     0.729777                     25.1                9.000        N        9.8        20.9           46.0         Compliance
     0.814189                     27.6                9.000        N        9.8        18.4           46.0         Compliance
     0.890466                     23.6                9.000        N        9.8        22.4           46.0         Compliance




                                                                                                                      Page 15 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RXM190322051-00C

FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205

EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission tests were performed in the 3 meters chamber A test site for the range 30MHz to
1GHz and the 3 meters chamber B test site for above 1GHz, using the setup accordance with the ANSI
C63.10-2013. The specification used was the FCC 15.209, and FCC 15.247 limits.

The spacing between the peripherals was 10 cm.




                                                                                            Page 16 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RXM190322051-00C

EMI Test Receiver & Spectrum Analyzer Setup

The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

30MHz-1000MHz:

                      Measurement           RBW           Video B/W       IF B/W
                          QP               120 kHz         300 kHz        120kHz

Above 1GHz:

                       Measurement           Duty cycle        RBW         Video B/W
                           PK                   Any            1MHz          3 MHz
                                               >98%            1MHz          10 Hz
                           Ave.
                                               <98%            1MHz            1/T

Note: T is minimum transmission duration


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




                                                                                             Page 17 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RXM190322051-00C

Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
    Manufacturer           Description                 Model
                                                                     Number            Date         Due Date
         R&S           EMI Test Receiver            ESCI              100035        2018-08-03     2019-08-03
        Farad            Test Software             EZ-EMC            V1.1.4.2          N/A            N/A
    Sunol Sciences          Antenna                  JB3            A060611-3       2017-07-21     2019-07-21
       Unknown           Coaxial Cable            C-NJNJ-50         C-0400-02       2018-09-05     2019-09-05
       Unknown           Coaxial Cable            C-NJNJ-50         C-0075-02       2018-09-05     2019-09-05
       Unknown           Coaxial Cable            C-NJNJ-50         C-2200-01       2018-09-05     2019-09-05
          HP               Amplifier                8447F          2443A01912       2018-09-05     2019-09-05
        Agilent        Spectrum Analyzer           E4440A          SG43360054       2019-01-04     2020-01-04
    ETS-Lindgren         Horn Antenna                3115           000 527 35      2019-01-04     2020-01-04
      Ducommun                                                     1007726-01
                          Horn Antenna          ARH-4223-02                         2016-11-18     2019-11-18
     Technolagies                                                      1304
                                               AFS42-00101800-
        MITEQ               Amplifier                                 2001271       2018-09-05     2019-09-05
                                                   25-S-42
       Quinstar            Amplifier          QLW-18405536-JO      15964001001      2018-06-27     2019-06-27
       Unknown            Coaxial Cable           C-SJSJ-50         C-0800-01       2018-09-05     2019-09-05
       Unknown            Coaxial Cable         C-2.4J2.4J-50       C-0700-02       2018-06-27     2019-06-27
                                              OBSF-2400-2483.5-
     E-Microwave        Band-stop Filters                          OE01601525       2018-06-16     2019-06-16
                                                      S
     Micro-tronics       High Pass Filter        HPM50111            S/N-G217       2018-06-16     2019-06-16

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

     Environmental Conditions

              Temperature:               26.9~27.1C
         Relative Humidity:               43~56 %
            ATM Pressure:                  99.6 kPa

     * The testing was performed by Tyler Pan & Vito Chen from 2019-03-28 to 2019-04-05.

Test Mode: Transmitting




                                                                                                    Page 18 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RXM190322051-00C

1) 30MHz-1GHz (High Channel was the worst):
Horizontal:




                    Receiver                          Correction     Cord.
  Frequency                                                                         Limit       Margin
                    Reading           Detector         Factor        Amp.
    (MHz)                                                                         (dBuV/m)       (dB)
                    (dBuV)                             (dB/m)      (dBuV/m)
    30.9700           27.47             peak               0.91     28.38           40.00        11.62
   320.0300           34.95             peak               -3.45    31.50           46.00        14.50
   419.9400           35.68             peak               -1.56    34.12           46.00        11.88
   540.2200           31.38             peak               0.31     31.69           46.00        14.31
   711.9100           28.00             peak               3.19     31.19           46.00        14.81
   965.0800           11.85             peak               22.90    34.75           54.00        19.25

Note: Peak meets QP limit, so QP value was not recorded.




                                                                                               Page 19 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RXM190322051-00C

Vertical:




                    Receiver                          Correction     Cord.
  Frequency                                                                         Limit       Margin
                    Reading           Detector         Factor        Amp.
    (MHz)                                                                         (dBuV/m)       (dB)
                    (dBuV)                             (dB/m)      (dBuV/m)

    30.9700           28.58             peak               0.91     29.49           40.00        10.51
    44.5500           41.26             peak               -8.96    32.30           40.00         7.70
   360.7700           31.42             peak               -2.80    28.62           46.00        17.38
   419.9400           30.70             peak               -1.56    29.14           46.00        16.86
   640.1300           29.04             peak               2.27     31.31           46.00        14.69
   969.9300           11.58             peak               23.00    34.58           54.00        19.42

Note: Peak meets QP limit, so QP value was not recorded.




                                                                                               Page 20 of 33


  Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM190322051-00C

 2) 1-25GHz:

                  Receiver             Rx Antenna      Cable Amplifier    Corrected
Frequency                                                                               Limit     Margin
            Reading    Detector       Polar Factor       loss    Gain     Amplitude
  (MHz)                                                                               (dBμV/m)     (dB)
            (dBμV) (PK/QP/AV)         (H/V) (dB/m)      (dB)     (dB)     (dBμV/m)
                                          Low Channel: 2402 MHz
 2402.00      53.09         PK          H     28.10     1.80      0.00      82.99        N/A        N/A
 2402.00      51.96         AV          H     28.10     1.80      0.00      81.86        N/A        N/A
 2402.00      59.54         PK          V     28.10     1.80      0.00      89.44        N/A        N/A
 2402.00      58.34         AV          V     28.10     1.80      0.00      88.24        N/A        N/A
 2390.00      25.67         PK          V     28.08     1.80      0.00      55.55       74.00      18.45
 2390.00      13.24         AV          V     28.08     1.80      0.00      43.12       54.00      10.88
 4804.00      47.03         PK          V     32.91     3.17     37.20      45.91       74.00      28.09
 4804.00      34.50         AV          V     32.91     3.17     37.20      33.38       54.00      20.62
 7206.00      45.67         PK          V     35.74     4.82     37.23      49.00       74.00      25.00
 7206.00      33.10         AV          V     35.74     4.82     37.23      36.43       54.00      17.57
                                         Middle Channel: 2440 MHz
 2440.00      54.57         PK          H     28.18     1.82      0.00      84.57        N/A        N/A
 2440.00      53.50         AV          H     28.18     1.82      0.00      83.50        N/A        N/A
 2440.00      61.15         PK          V     28.18     1.82      0.00      91.15        N/A        N/A
 2440.00      60.21         AV          V     28.18     1.82      0.00      90.21        N/A        N/A
 4880.00      47.43         PK          V     33.06     3.27     37.21      46.55       74.00      27.45
 4880.00      34.89         AV          V     33.06     3.27     37.21      34.01       54.00      19.99
 7320.00      46.10         PK          V     36.03     4.62     37.37      49.38       74.00      24.62
 7320.00      33.57         AV          V     36.03     4.62     37.37      36.85       54.00      17.15
                                          High Channel: 2480 MHz
 2480.00      55.26         PK          H     28.26     1.84      0.00      85.36        N/A        N/A
 2480.00      54.10         AV          H     28.26     1.84      0.00      84.20        N/A        N/A
 2480.00      62.02         PK          V     28.26     1.84      0.00      92.12        N/A        N/A
 2480.00      60.89         AV          V     28.26     1.84      0.00      90.99        N/A        N/A
 2483.50      25.69         PK          V     28.27     1.84      0.00      55.80       74.00      18.20
 2483.50      13.30         AV          V     28.27     1.84      0.00      43.41       54.00      10.59
 4960.00      47.88         PK          V     33.22     3.23     37.25      47.08       74.00      26.92
 4960.00      35.31         AV          V     33.22     3.23     37.25      34.51       54.00      19.49
 7440.00      45.98         PK          V     36.34     4.41     37.52      49.21       74.00      24.79
 7440.00      33.45         AV          V     36.34     4.41     37.52      36.68       54.00      17.32




                                                                                          Page 21 of 33


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RXM190322051-00C

    Worst plots (High Channel)
    Horizontal


Fundamental
Test with Band
Rejection Filter




                                                                          Page 22 of 33


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RXM190322051-00C

    Vertical


Fundamental
Test with Band
Rejection Filter




                                                                          Page 23 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM190322051-00C


FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH
Applicable Standard
According to FCC §15.247(a) (2)

Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure

a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3×RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
   maximum level measured in the fundamental emission.


                                EUT                                Signal Analyzer



Test Equipment List and Details

                                                                   Serial        Calibration     Calibration
    Manufacturer           Description               Model
                                                                  Number            Date          Due Date

         R&S           EMI Test Receiver             ESPI          100120         2018-12-11      2019-12-11

      Unknown             Coaxial Cable        C-SJ00-0010       C0010/01         Each time          N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                28.8 C
         Relative Humidity:                57 %
            ATM Pressure:                100.2 kPa

    * The testing was performed by Andy Huang on 2019-03-27.




                                                                                                    Page 24 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                     Report No.: RXM190322051-00C

   Test Mode: Transmitting

  Test Result: Compliance. Please refer to the following table and plots.


                                               Frequency                  6 dB Bandwidth                  Limit
                          Channel
                                                 (MHz)                        (MHz)                      (MHz)
                             Low                        2402                      0.708                   ≥0.5
                            Middle                      2440                      0.556                   ≥0.5
                             High                       2480                      0.544                   ≥0.5



                                                               Low Channel
                                                                   * RBW 100 kHz       Delta 1 [T1 ]
                                                                   * VBW 300 kHz                  -0.02 dB
                      Ref    20 dBm            * Att     30 dB       SWT 2.5 ms           708.000000000 kHz
                      20    Offset    0.5 dB                                           Marker 1 [T1 ]
                                                                                                  -1.38 dBm
                                                                                            2.401676000 GHz   A
                      10

               1 PK            D1 4.63 dBm
               MAXH                                 1                              1
                      0
                                     D2 -1.37 dBm                                                             LVL


                      -10



                      -20



                      -30

                                                                                                              3DB
                      -40



                      -50



                      -60



                      -70


                      -80

                      Center 2.402 GHz                         200 kHz/                          Span 2 MHz




               Date: 27.MAR.2019           20:05:36




                                                                                                                       Page 25 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RXM190322051-00C


                                                          Middle Channel
                                                                * RBW 100 kHz   Delta 1 [T1 ]
                                                                * VBW 300 kHz              -0.27 dB
                      Ref    20 dBm            * Att    30 dB     SWT 2.5 ms       556.000000000 kHz
                      20    Offset    0.5 dB                                    Marker 1 [T1 ]
                                                                                           -0.63 dBm
                                                                                     2.439676000 GHz   A
                      10

               1 PK            D1 5.32 dBm
               MAXH                                 1                  1
                      0              D2 -0.68 dBm                                                      LVL


                      -10



                      -20



                      -30

                                                                                                       3DB
                      -40



                      -50



                      -60



                      -70


                      -80

                      Center 2.44 GHz                       200 kHz/                      Span 2 MHz




              Date: 27.MAR.2019            20:07:21


                                                            High Channel
                                                                * RBW 100 kHz   Delta 1 [T1 ]
                                                                * VBW 300 kHz               0.25 dB
                      Ref    20 dBm            * Att    30 dB     SWT 2.5 ms       544.000000000 kHz
                      20    Offset    0.5 dB                                    Marker 1 [T1 ]
                                                                                           -0.09 dBm
                                                                                     2.479676000 GHz   A
                      10
                               D1 5.95 dBm
               1 PK
                                                    1                  1
               MAXH
                      0              D2 -0.05 dBm
                                                                                                       LVL


                      -10



                      -20



                      -30

                                                                                                       3DB
                      -40



                      -50



                      -60



                      -70


                      -80

                      Center 2.48 GHz                       200 kHz/                      Span 2 MHz




              Date: 27.MAR.2019            20:08:53




                                                                                                                Page 26 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM190322051-00C

FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure
1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test
   equipment.
3. Add a correction factor to the display.
4. Set the power Meter to test Peak output power, record the result as peak power.
5. Set the power meter to test average output power, record the result as average power.


                                                                         Power
                                EUT                                      Meter



Test Equipment List and Details

                                                                   Serial        Calibration     Calibration
    Manufacturer           Description               Model
                                                                  Number            Date          Due Date
                         USB Wideband
        Agilent                                 U2022XA         MY5417006         2018-12-11      2019-12-11
                          Power Sensor
      Unknown             Coaxial Cable        C-SJ00-0010       C0010/03         Each time          N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                28.8 C
         Relative Humidity:                57 %
            ATM Pressure:                100.2 kPa

    * The testing was performed by Andy Huang on 2019-03-27.




                                                                                                    Page 27 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RXM190322051-00C

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table.

                                                        Max Peak
                                      Frequency      Conducted Output     Limit
                       Channel
                                        (MHz)             Power          (dBm)
                                                          (dBm)
                         Low             2402              5.08            30
                        Middle           2440              5.75            30
                         High            2480              6.42            30




                                                                                         Page 28 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM190322051-00C

FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If
the transmitter complies with the conducted power limits based on the use of RMS averaging over a time
interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph
shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not
required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


Test Equipment List and Details

                                                                   Serial        Calibration     Calibration
    Manufacturer           Description               Model
                                                                  Number            Date          Due Date

         R&S           EMI Test Receiver             ESPI          100120         2018-12-11      2019-12-11

       Unknown            Coaxial Cable        C-SJ00-0010       C0010/01         Each time          N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

              Temperature:                28.8 C
         Relative Humidity:                57 %
            ATM Pressure:                100.2 kPa

    * The testing was performed by Andy Huang on 2019-03-27.




                                                                                                    Page 29 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                 Report No.: RXM190322051-00C

Test mode: Transmitting
Test Result: Compliance. Please refer to following plots.
                                                       Band Edge, Left Side
                                                                    * RBW 100 kHz   Marker 2 [T1 ]
                                                                    * VBW 300 kHz             -44.35 dBm
                      Ref    20 dBm            * Att    30 dB        SWT 2.5 ms          2.399984000 GHz
                      20    Offset    0.5 dB                                        Marker 1 [T1 ]
                                                                                                4.61 dBm
                                                                                         2.401760000 GHz   A
                      10
                                                                                    1
               1 PK
               MAXH
                      0
                                                                                                           LVL


                      -10
                      -15.39dBm

                      -20



                      -30

                                                                                                           3DB
                      -40
                                                                2


                      -50



                      -60



                      -70


                      -80

                      Center 2.4 GHz                        800 kHz/                          Span 8 MHz




               Date: 27.MAR.2019          20:06:53


                                                       Band Edge, Right Side
                                                                    * RBW 100 kHz   Marker 2 [T1 ]
                                                                    * VBW 300 kHz             -48.54 dBm
                      Ref    20 dBm            * Att    30 dB        SWT 2.5 ms          2.484816000 GHz
                      20    Offset    0.5 dB                                        Marker 1 [T1 ]
                                                           -14.03dBm                            5.97 dBm
                                                                                         2.479776000 GHz   A
                      10                  1
               1 PK
               MAXH
                      0
                                                                                                           LVL


                      -10



                      -20



                      -30

                                                                                                           3DB
                      -40

                                                                         2
                      -50



                      -60



                      -70


                      -80

                      Center 2.4835 GHz                     1.4 MHz/                         Span 14 MHz




               Date: 27.MAR.2019          20:10:06




                                                                                                                   Page 30 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM190322051-00C

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
According to FCC§15.247(e):For digitally modulated systems, the power spectral density conducted from
the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
interval of continuous transmission. This power spectral density shall be determined in accordance with
the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and
   connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one
   measured frequency within its operating range, and make sure the instrument is operated in its linear
   range.
3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth.
4. Use the peak marker function to determine the maximum amplitude level.


Test Equipment List and Details

                                                                   Serial        Calibration     Calibration
    Manufacturer           Description               Model
                                                                  Number            Date          Due Date

         R&S           EMI Test Receiver             ESPI          100120         2018-12-11      2019-12-11

      Unknown             Coaxial Cable        C-SJ00-0010       C0010/01         Each time          N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

              Temperature:                28.8 C
         Relative Humidity:                57 %
            ATM Pressure:                100.2 kPa

    * The testing was performed by Andy Huang on 2019-03-27.




                                                                                                    Page 31 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RXM190322051-00C

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots


                                                     Frequency              PSD                 Limit
                              Channel
                                                       (MHz)             (dBm/3kHz)          (dBm/3kHz)
                                Low                      2402               -13.28                 ≤8
                               Middle                    2440               -12.29                 ≤8
                               High                      2480               -11.66                 ≤8



                                            Power Spectral Density, Low Channel
                                                                 * RBW 3 kHz    Marker 1 [T1 ]
                                                                 * VBW 10 kHz             -13.28 dBm
                        Ref    20 dBm            * Att   30 dB     SWT 120 ms        2.401800344 GHz
                        20    Offset    0.5 dB

                                                                                                       A
                        10

                 1 PK
                 MAXH
                        0
                                                                                                       LVL


                        -10                      1


                        -20



                        -30

                                                                                                       3DB
                        -40



                        -50



                        -60



                        -70


                        -80

                        Center 2.402 GHz                    106.2 kHz/                Span 1.062 MHz




                 Date: 27.MAR.2019          20:06:21




                                                                                                                Page 32 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                  Report No.: RXM190322051-00C


                                        Power Spectral Density, Middle Channel
                                                                     * RBW 3 kHz    Marker 1 [T1 ]
                                                                     * VBW 10 kHz             -12.29 dBm
                      Ref    20 dBm                 * Att   30 dB       SWT 95 ms        2.439821524 GHz
                      20    Offset    0.5 dB

                                                                                                           A
                      10

               1 PK
               MAXH
                      0
                                                                                                           LVL


                      -10                       1



                      -20



                      -30

                                                                                                           3DB
                      -40



                      -50



                      -60



                      -70


                      -80

                      Center 2.44 GHz                           83.4 kHz/                   Span 834 kHz




              Date: 27.MAR.2019           20:08:00


                                         Power Spectral Density, High Channel
                                                                     * RBW 3 kHz    Marker 1 [T1 ]
                                                                     * VBW 10 kHz             -11.66 dBm
                      Ref    20 dBm                 * Att   30 dB       SWT 95 ms        2.480009792 GHz
                      20    Offset    0.5 dB

                                                                                                           A
                      10

               1 PK
               MAXH
                      0
                                                                                                           LVL


                                                                    1
                      -10



                      -20



                      -30

                                                                                                           3DB
                      -40



                      -50



                      -60



                      -70


                      -80

                      Center 2.48 GHz                           81.6 kHz/                   Span 816 kHz




              Date: 27.MAR.2019           20:09:31



                                               ***** END OF REPORT *****


                                                                                                                    Page 33 of 33



Document Created: 2019-06-11 06:14:44
Document Modified: 2019-06-11 06:14:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC