According to 447498 D01 General RF Exposure Guidance v05

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
separation distances ≤ 50 mm are determined by:

[(max. power of channel, including tune-up tolerance, mW)/(min. test separation
distance, mm)] •[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,
where

• f(GHz) is the RF channel transmit frequency in GHz

• Power and distance are rounded to the nearest mW and mm before calculation

• The result is rounded to one decimal place for comparison



Worse case is as below: [2462 MHz 9.7dBm(9.3 mW) output power]



(9.3mW /5mm) •[√2.462(GHz)]=2.918 <3.0 for 1-g SAR



Then SAR evaluation is not required