Test report

FCC ID: 2ABQ6-K10

Test Report

Download: PDF
FCCID_4384734

                                                   TEST REPORT
Report No. ...................................... :       CHTEW19070050                     Report Verification:

Project No…………………………....:                                 SHT1906080901EW

FCC ID ............................................. :    2ABQ6-K10

Applicant’s name ........................... :            Inspira Technologies LLC

Address ............................................. :   1901 4th Ave, Suite 210, San Diego, CA 92101, USA

Manufacturer.....................................:        Inspira Technologies LLC

Address.............................................:     1901 4th Ave, Suite 210, San Diego, CA 92101, USA

Test item description .................... :              Tablet

Trade Mark ....................................... :      -

Model/Type reference ....................... :            K10

Listed Model(s) ................................. :       -

Standard ......................................... :      47 CFR FCC Part 15 Subpart B

Date of receipt of test sample………..:                      Jun.27, 2019

Date of testing…………………………:                                Jun.27, 2019- Jul.12, 2019

Date of issue…………………………...:                               Jul.15, 2019

Result .................. …………………...:                     Pass

Compiled by

( Position+Printed name+Signature):                       File administrators Fanghui Zhu

Supervised by

(Position+Printed name+Signature):                        Project Engineer Tom Ouyang

Approved by
( position+printed name+signature) .. :                   RF Manager Hans Hu


Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao,
                                                          Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.

The test report merely corresponds to the test sample.


                                                                   Page: 1 of 18


Report No : CHTEW19070050                                                Page 2 of 18                                                          Issued: 2019-07-15




                                                                         Contents

1.       TEST STANDARDS AND REPORT VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1.    Test Standards                                                                                                                                                    3
1.2.    Report version information                                                                                                                                        3

2.       TEST DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4



3.       SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1.    Client Information                                                                                                                                                5
3.2.    Product Description                                                                                                                                               5
3.3.    EUT operation mode                                                                                                                                                5
3.4.    Configuration of Tested System                                                                                                                                    5
3.5.    Support unit used in test configuration                                                                                                                           6

4.       TEST ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4.1.    Address of the test laboratory                                                                                                                                    7
4.2.    Test Facility                                                                                                                                                     7
4.3.    Environmental conditions                                                                                                                                          8
4.4.    Statement of the measurement uncertainty                                                                                                                          8
4.5.    Equipments Used during the Test                                                                                                                                   9

5.       TEST CONDITIONS AND RESULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 0

5.1.    Conducted Emissions Test                                                                                                                                          10
5.2.    Radiated Emissions Test                                                                                                                                           13

6.       TEST SETUP PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7



7.       EXTERNAL AND INTERNAL PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 8




Shenzhen Huatongwei International Inspection Co., Ltd.                                                     Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                         Page 3 of 18                         Issued: 2019-07-15



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014 – American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2019-07-15                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                       Page 4 of 18                               Issued: 2019-07-15



2. TEST DESCRIPTION
               Test Item                         Section in CFR 47                Result       Test Engineer
         Conducted Emissions                          15.107(a)                    PASS          Kang Yang
          Radiated Emissions                          15.109(a)                    PASS          Tony Duan


Note: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : CHTEW 19070050                                   Page 5 of 18                               Issued: 2018—07—15



3. SUMMARY
3.1. Client Information
Applicant:                               Inspira Technologies LLC
Address:                                 1901 4th Ave, Suite 210, San Diego, CA 92101, USA
Manufacturer:                            Inspira Technologies LLC
Address:                                 1901 4th Ave, Suite 210, San Diego, CA 92101, USA
3.2. Product Description
Name of EUT:                             Tablet
Trade Maic:                              —
Model No.:                               10
Listed Model{s)                          —
Power supply:                            DC 3.7V from battery
                                         Model: K—T100502000U

Adapter information:                     Input: 100—240¥a.0., 50—60He, 0.35A Max

                                         Output: 5¥d.5., 2000mA


3.3. EUT operation mode
Test morle      Date           Playing       Record
              me              Video§TF       Video
                                                      Homt     sowiei       wiri     BTEDR    BTBLE    ACAchptor   Earphone
                   /                                                                                                  /

                                                                                                                      /

                                                                                                                      v




    8                                                                                           /          /
Pre—scan all of above modes. Only show data exchange mode which is the worst case on the report.
3.4. Configuration of Tested System



                   Printere                  Poo              EuTe                 Montor




                                         Keyboarde              Mouses



‘Shonghen HuatongwelInternational inspection Co., L1d.                              Report Template Version: VO1 (2018—01)


Report No : CHTEW19070050                     Page 6 of 18                         Issued: 2019-07-15


3.5. Support unit used in test configuration
                                                             FCC ID /
Item    Equipment      Manufacturer        Model No.                     Data Cable     Power Cord
                                                             FCC DoC
                                                                                        Unshielded
 1          PC             DELL         OptiPlex 3020 MT     FCC DoC         N/A
                                                                                          1.8m
                                                                                        Unshielded
 2        Monitor          DELL             E1912Hf          FCC DoC         N/A
                                                                                          1.8m
                                                                         Unshielded,
 3       Keyboard          DELL             SK8115           FCC DoC                        N/A
                                                                           1.5m
                                                                         Unshielded,
 4        Mouse            DELL             MS111-T          FCC DoC                        N/A
                                                                           1.5m
                                                                                        Unshielded
 5        Printer         EPSON               L101           FCC DoC         N/A
                                                                                          1.8m




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                          Page 7 of 18                             Issued: 2019-07-15



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377A

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377A.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                      Page 8 of 18                              Issued: 2019-07-15



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba



4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

                                                                       Measurement
                Test                             Range                                     Notes
                                                                        Uncertainty
Radiated Emissions                         30~1000MHz                     4.90 dB           (1)
Radiated Emissions                           1~18GHz                      4.96 dB           (1)
Conducted Disturbance                      0.15~30MHz                     3.02 dB           (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                         Page 9 of 18                              Issued: 2019-07-15

4.5. Equipments Used during the Test
●      Conducted Emission
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)

 ●     Shielded Room         Albatross projects        N/A             N/A        2018/09/28       2023/09/27

 ●     EMI Test Receiver           R&S                 ESCI          101247       2018/10/27       2019/10/26

 ●     Artificial Mains      SCHWARZBECK            NNLK 8121          573        2018/10/27       2019/10/26

 ●     Pulse Limiter               R&S               ESH3-Z2         100499       2018/10/27       2019/10/26

 ●     RF Connection Cable   HUBER+SUHNER             EF400            N/A        2018/11/15       2019/11/14

 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A
       Single Balanced
 ○                                 FCC            FCC-TLISN-T2-02    20371        2018/10/28       2019/10/27
       Telecom Pair ISN
       Two Balanced
 ○                                 FCC            FCC-TLISN-T4-02    20373        2018/10/28       2019/10/27
       Telecom Pairs ISN
       Four Balanced
 ○                                 FCC            FCC-TLISN-T8-02    20375        2018/10/28       2019/10/27
       Telecom Pairs ISN
 ○     V-Network                   R&S               ESH3-Z6         100211       2018/10/27       2019/10/26

 ○     V-Network                   R&S               ESH3-Z6         100210       2018/10/27       2019/10/26

 ○     2-Line V-Network            R&S               ESH3-Z5         100049       2018/10/27       2019/10/26


 ●     Radiated Emission-6th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-02          N/A        2018/09/30       2021/09/29
       Chamber
 ●     EMI Test Receiver           R&S                 ESCI          100900       2018/10/28       2019/10/27

 ●     Loop Antenna                R&S               HFH2-Z2         100020       2017/11/20       2020/11/19
       Ultra-Broadband
 ●                           SCHWARZBECK             VULB9163          546        2017/04/05       2020/04/04
       Antenna
 ●     Pre-Amplifer          SCHWARZBECK             BBV 9742          N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER              N/A             N/A        2018/09/28       2019/09/27
 ●     RF Connection Cable   HUBER+SUHNER          SUCOFLEX104      501184/4      2018/09/28       2019/09/27
 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A


 ●     Radiated emission-7th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-01          N/A        2018/09/30       2021/09/29
       Chamber
 ●     Spectrum Analyzer           R&S                FSP40          100597       2018/10/27       2019/10/26

 ●     Horn Antenna          SCHWARZBECK              9120D           1011        2017/03/27       2020/03/26

 ●     Pre-amplifier              BONN             BLWA0160-2M      1811887       2018/11/14       2019/11/13

 ●     Pre-amplifier                CD               PAP-0102        12004        2018/11/14       2019/11/13
       Broadband Pre-
 ●                           SCHWARZBECK             BBV 9718       9718-248      2019/04/26       2020/04/25
       amplifier
 ●     RF Connection Cable   HUBER+SUHNER            RE-7-FH           N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER             RE-7-FL          N/A        2018/11/15       2019/11/14

 ●     Test Software               Audix                E3             N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A

Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                      Page 10 of 18                            Issued: 2019-07-15



5. TEST CONDITIONS AND RESULTS
5.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart B Section 15.107:
                                                                      Limit (dBuV)
          Frequency range (MHz)
                                                      Quasi-peak                        Average
                  0.15-0.5                             66 to 56*                        56 to 46*
                    0.5-5                                 56                               46
                    5-30                                  60                               50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4:2014
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 80 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


  Level [dBpV)
so




                                                      s}——




                                                                                  #L——
                          300k   400k     600k   8 O0k 1




                                                                       n
                                                                         2



                                                                                  &
                                                                     Frequency [Hz]
x x xae                cx1807015032_Ein


MEASUREMENT RESULT:                                        "GM1907015032_fin"

     Frequency                          Level        Transd           Limit              Margin   Detector   Line    PE
                          MHz            dBuv                  dB       dBuy                 ds

                      204000            40.40                 9.9            63            23.0   QP         L1     GND
      to n ta i o o




                      366000            35. 60                9.9            59            23.0   QP         L1     GND
                      756500            31.80                 9.9            56            24.2   QP         L1     GND
                      742000            19.70                 9.9            56            36.3   QP         L1     GND
                      298000            28.40                10 .0           60            31.6   QP         L1     GND
                      144500            27.00                10 .2           60            33.0   QP         L1     GND




MEASUREMENT RESULT:                                        "GM1907015032_fin2"


     Frequency                          Level        Transd           Limit              Margin   Detector   Line    PE
           MHz                           dBuv                  dB       dBuvy                dB

                      330000            26.20                 9.9            50            23.3   AV         L1     GND
      to n Io 0 0 o




                      397500            22.60                 9.9            48            25.3   AV         L1     GND
                      &942000            9. 60                9.9            46            26.4   AV         L1     GND
                      674500            17.20                 9.9            46            28.8   AV         L1     GND
                      194500            16.80                10 .0           50            33.2   AV         L1     GND
                      932000            17.80                10 .2           50            32.2   AV         L1     GND


  Level [dBpV)




                                                Frequency [Hz]
x x xiEs    em1907018031_fin

 MEASUREMENT RESULT:                   "GM1907015031_fin"


      Frequency            Level      Transd     Limit           Margin   Detector      Line        PE
                 MHz           dBuy       dB       dBuv              dB

        0.204000           42.80         9.9           63          20.6   P                        GND




                                                                                     2 2 2 5 9R
       0. 352500           27. 90        9.9           59          31.0   QP                       GND
       0. 852000           26. 90        9.9           56          29.1   QP                       GND
       3. 421500           20.00         9. 9          56          36.0   QP                       GND
      10896000             17.80        10.1           60          42.2   QP                       GND
      23.320500            17.40        10.3           60          42.6   QP                       GND




 MEASUREMENT RESULT:                   "GM1907015031_fin2"


      Frequency            Level      Transd     Limit           Margin   Detector      Line        PE
            MBz             dBuV          dB      dBuv               dB

        0.334500           29.10         9. 9          49          20.2   AV                       GND
                                                                                     2 2 2 2 5 9




        0. 352500          15. 90        9. 9          49          33.0   AV                       GND
        0. 915000          17.30         9. 9          46          28.7   AV                       GND
       3.565500            14.20         9.9           46          31.8   AV                       GND
       5.154000            12.10        10 .0          50          37.9   AV                       GND
      19.261500             6.40        10.2           50          43.6   AV                       GND


Report No : CHTEW19070050                       Page 13 of 18                              Issued: 2019-07-15



5.2. Radiated Emissions Test
LIMIT

FCC CFR Title 47 Part 15 Subpart B Section 15.109
              Frequency                       Limit (dBuV/m @3m)                              Value
             30MHz-88MHz                                   40.00                           Quasi-peak
             88MHz-216MHz                                  43.50                           Quasi-peak
            216MHz-960MHz                                  46.00                           Quasi-peak
             960MHz-1GHz                                   54.00                           Quasi-peak
                                                           54.00                             Average
              Above 1GHz
                                                           74.00                              Peak

TEST CONFIGURATION

    30MHz ~ 1GHz




    Above 1GHz




TEST PROCEDURE

1.   The EUT was tested according to ANSI C63.4:2014.
2.   The EUT is placed on a turn table which is 0.8 meter above ground.
3.   The turn table is rotated 360 degrees to determine the position of the maximum emission level.
4.   The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
5.   The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
     repeated for both horizontal and vertical polarization of the antenna.
6.   Use the following spectrum analyzer settings
     (1) Span shall wide enough to fully capture the emission being measured;
     (2) Below 1GHz,
          RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, theemission measurement will be repeated using
          the quasi-peak detector and reported.
     (3) From 1GHz to 5th harmonic, RBW=1MHz, VBW=3MHz

Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                     Page 14 of 18                           Issued: 2019-07-15


TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable


Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Shenzhen Huatongwei International Inspection Co., Ltd.            Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                     Page 15 of 18                              Issued: 2019-07-15


Polarization:                                            Horizontal




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                     Page 16 of 18                            Issued: 2019-07-15


Polarization:                                            Vertical




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                     Page 17 of 18                      Issued: 2019-07-15



6. TEST SETUP PHOTOS OF THE EUT
Conducted Emissions (AC Mains)




Radiated Emissions (30MHz-1GHz)




Radiated Emissions (Above 1GHz)




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19070050                     Page 18 of 18                        Issued: 2019-07-15




7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT

    Reference to the test report No.: CHTEW19070046.


                                        --------End of Report--------




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)



Document Created: 2019-07-26 15:11:47
Document Modified: 2019-07-26 15:11:47

© 2024 FCC.report