Test report

FCC ID: 2ABQ6-DCG-N10

Test Report

Download: PDF
FCCID_4066373

                                                   TEST REPORT
Report Reference No. .................... :               TRE1810009704                    R/C…….: 66746

FCC ID ............................................. :    2ABQ6-DCG-N10

Applicant’s name ........................... :            Inspira Technologies LLC

Address ............................................. :   1901 4th Ave, Suite 210, San Diego, CA 92101, USA

Manufacturer......................................:       Inspira Technologies LLC

Address...............................................:   1901 4th Ave, Suite 210, San Diego, CA 92101, USA

Test item description .................... :              Tablet PC

Trade Mark ....................................... :      datecode genie

Model/Type reference ....................... :            DCG-N10

Listed Model(s) ................................. :       -

Standard ......................................... :      47 CFR FCC Part 15 Subpart B

Date of receipt of test sample………..:                      Oct.15,2018

Date of testing…………………………:                                Oct.15,2018 ~ Oct.25,2018

Date of issue…………………………...:                               Oct.25,2018

Result .................. …………………...:                     Pass

Compiled by
( position+printed name+signature) .. :                   File administrators Yueming Li
Supervised by
( position+printed name+signature) .. :                   Project Engineer Tom Ouyang
Approved by
( position+printed name+signature) .. :                   RF Manager Hans Hu


Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao,
                                                          Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.

The test report merely corresponds to the test sample.




                                                                 Page: 1 of 18


Report No : TRE1810009704                                                Page 2 of 18                                                          Issued: 2018-10-25




                                                                         Contents

1.       TEST STANDARDS AND REPORT VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1.    Test Standards                                                                                                                                                    3
1.2.    Report version information                                                                                                                                        3

2.       TEST DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4



3.       SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1.    Client Information                                                                                                                                                5
3.2.    Product Description                                                                                                                                               5
3.3.    EUT operation mode                                                                                                                                                5
3.4.    Configuration of Tested System                                                                                                                                    5
3.5.    Support unit used in test configuration                                                                                                                           6

4.       TEST ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4.1.    Address of the test laboratory                                                                                                                                    7
4.2.    Test Facility                                                                                                                                                     7
4.3.    Environmental conditions                                                                                                                                          8
4.4.    Statement of the measurement uncertainty                                                                                                                          8
4.5.    Equipments Used during the Test                                                                                                                                   9

5.       TEST CONDITIONS AND RESULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 0

5.1.    Conducted Emissions Test                                                                                                                                          10
5.2.    Radiated Emissions Test                                                                                                                                           13

6.       TEST SETUP PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7



7.       EXTERNAL AND INTERNAL PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 8




Shenzhen Huatongwei International Inspection Co., Ltd.                                                     Report Template Version: V01 (2018-01)


Report No : TRE1810009704                         Page 3 of 18                         Issued: 2018-10-25



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014 – American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2018-10-25                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : TRE1810009704                       Page 4 of 18                               Issued: 2018-10-25



2. TEST DESCRIPTION
               Test Item                         Section in CFR 47                Result       Test Engineer
         Conducted Emissions                          15.107(a)                    PASS          Tony Duan
          Radiated Emissions                          15.109(a)                    PASS         Michael Jie


Note: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : TRE1810009704                      Page 5 of 18                             Issued: 2018-10-25



3. SUMMARY
3.1. Client Information
Applicant:                    Inspira Technologies LLC

Address:                      1901 4th Ave, Suite 210, San Diego, CA 92101, USA

Manufacturer:                 Inspira Technologies LLC

Address:                      1901 4th Ave, Suite 210, San Diego, CA 92101, USA

3.2. Product Description
Name of EUT:                  Tablet PC

Trade Mark:                   datecode genie

Model No.:                    DCG-N10
Listed Model(s)               -
Power supply:                 3.7 V from battery
                              Model No:K-T100502000U
Adapter information:          Input:100-240Va.c.50-60Hz 0.35A Max
                              Output:5Vd.c.2000mA


3.3. EUT operation mode
Test mode                                                       Describe
Burnin test mode              Keep the EUT in work at burnin test vis the brunin software status.
Data exchange mode            Keep the EUT in data exchange with mobilephone status.
Pre-scan all of above modes. Only show data exchange mode which is the worst case on the report.
3.4. Configuration of Tested System




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : TRE1810009704                     Page 6 of 18                         Issued: 2018-10-25


3.5. Support unit used in test configuration
                                                             FCC ID /
Item    Equipment      Manufacturer        Model No.                     Data Cable     Power Cord
                                                             FCC DoC
                                                                                        Unshielded
 1          PC             DELL         OptiPlex 3020 MT     FCC DoC         N/A
                                                                                          1.8m
                                                                                        Unshielded
 2        Monitor          DELL             E1912Hf          FCC DoC         N/A
                                                                                          1.8m
                                                                         Unshielded,
 3       Keyboard          DELL             SK8115           FCC DoC                        N/A
                                                                           1.5m
                                                                         Unshielded,
 4        Mouse            DELL             MS111-T          FCC DoC                        N/A
                                                                           1.5m
                                                                                        Unshielded
 5        Printer         EPSON               L101           FCC DoC         N/A
                                                                                          1.8m




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)


Report No : TRE1810009704                          Page 7 of 18                             Issued: 2018-10-25



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377B-1

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B-1.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : TRE1810009704                      Page 8 of 18                              Issued: 2018-10-25



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba



4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

                                                                       Measurement
                Test                             Range                                     Notes
                                                                        Uncertainty
Radiated Emissions                         30~1000MHz                     4.28 dB           (1)
Radiated Emissions                           1~18GHz                      5.16 dB           (1)
Conducted Disturbance                      0.15~30MHz                     3.35 dB           (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : TRE1810009704                       Page 9 of 18                        Issued: 2018-10-25



4.5. Equipments Used during the Test
Conducted Emissions

        Test                                                                Last Cal.     Next Cal.
Item                       Manufacturer         Model No.      Serial No.
        Equipment                                                           (mm-dd-yy)    (mm-dd-yy)
        EMI Test
1                          R&S                  ESCI           101247       11/11/2017    11/10/2018
        Receiver
2       Artificial Mains   SCHWARZBECK          NNLK 8121      573          11/11/2017    11/10/2018
        2-Line V-
3                          R&S                  ESH3-Z5        100049       11/11/2017    11/10/2018
        Network
4       Pulse Limiter      R&S                  ESH3-Z2        101488       11/11/2017    11/10/2018
        RF
5       Connection         HUBER+SUHNER         EF400          N/A          11/21/2017    11/20/2018
        Cable
6       Test Software      R&S                  ES-K1          N/A          N/A           N/A


Radiated Emissions

        Test                                                                Last Cal.     Next Cal.
Item                       Manufacturer         Model No.      Serial No.
        Equipment                                                           (mm-dd-yy)    (mm-dd-yy)
        Semi-
1       Anechoic           Albatross projects   SAC-3m-01      C11121       10/16/2016    10/15/2019
        Chamber
        EMI Test
2                          R&S                  ESCI           100900       11/11/2017    11/10/2018
        Receiver
3       Loop Antenna       R&S                  HFH2-Z2        100020       11/20/2017    11/19/2020
        Ultra-
4       Broadband          SCHWARZBECK          VULB9163       538          4/5/2017      4/4/2020
        Antenna
5       Horn Antenna       SCHWARZBECK          9120D          1011         3/27/2017     3/26/2020
        Broadband                                              BBHA9170
6                          SCHWARZBECK          BBHA9170                    3/27/2017     3/26/2020
        Horn Antenna                                           472
7       Pre-amplifier      SCHWARZBECK          BBV 9743       9743-0022    10/18/2018    10/17/2019
        Broadband
8                          SCHWARZBECK          BBV 9718       9718-248     10/18/2018    10/17/2019
        Pre-amplifier
        Spectrum
9                          R&S                  FSP40          100597       11/11/2017    11/10/2018
        Analyzer
        RF Connection      HUBER+SUHNE
10                                              RE-7-FL        N/A          11/21/2017    11/20/2018
        Cable              R
        RF Connection      HUBER+SUHNE
11                                              RE-7-FH        N/A          11/21/2017    11/20/2018
        Cable              R
12      Test Software      Audix                E3             N/A          N/A           N/A
13      Test Software      R&S                  ES-K1          N/A          N/A           N/A
14      Turntable          Maturo Germany       TT2.0-1T       N/A          N/A           N/A
15      Antenna Mast       Maturo Germany       CAM-4.0-P-12   N/A          N/A           N/A




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)


Report No : TRE1810009704                      Page 10 of 18                            Issued: 2018-10-25



5. TEST CONDITIONS AND RESULTS
5.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart B Section 15.107:
                                                                      Limit (dBuV)
          Frequency range (MHz)
                                                      Quasi-peak                        Average
                  0.15-0.5                             66 to 56*                        56 to 46*
                    0.5-5                                 56                               46
                    5-30                                  60                               50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4:2014
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 80 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


  Level {dBpV)




                                              Frequency [Hz]
x x xHEs    RTWLO175044_fin



MEASUREMENT RESULT:                   "HTW10175044_fin"
10/17/2018   5112PM
   Frequency     Level               Transd   Limit      Margin       Detector   Line    PE
                 MHz          dBuv       dB    dBuv              dB

       0. 226500          52.30        10.2       63                  gP         L1     GND
       0. 456000          37. 60       10.1       57                  gP         L1     GND
       1.990500           33.10        10.0       56                  QP         l      GND
       2. 656500          34.50        10.0       56                  QP         LL     GND
      5.914500            31.80        10.0       60                  QP         LL     GND
     14.091000            31.50        10.2       60                  gP         L1     GND



MEASUREMENT RESULT:                   "HTWIO1l 75044_fin2"

10/17/2018             5:12PM
     Frequency            Level      Transd   Limit      Margin       Detector   Line    PE
                 MHz          dBuy       dB    dBuy              dB

       0. 226500          44.30        10.2       53            8.3   AV         L1     GND
       0.883500           26.70         9.9       46           19.3   aVv        L1     GND
       2.040000           28.20        10.0       46           17.8    AV        LL     GND
      2.850000            29.70        10.0       46           16.3   AV         L1     GND
      5.928000            25.90        10.0       50           24.1    AV        L1     GND
     13. 996500           25.70        10.2       50           24.3    AV        l      GND


  Level {dBpM]
80 ———




                                           s}—




                                                                                    3}—
                                60Ok   800k 1




                                                        is
                                                           2



                                                                  &
                                                                       E

                                                                           a&
                                                                            2
                                                                                a
                                                                                2
                                                                                    a
                                                      Frequency [Hz]
x x xmzs mnwio175045_fin


MEASUREMENT RESULT:                       "HTW1OL 75045_fi1: ""

10/17/2018             5:15PM
    Frequency             Level         Transd        Limit      Margin         Detector   Line    PE
                 MEz       dBuV                  dB    dBpV                dB
     0226500              51.30            10.2           63           11.3     P          N      GND
     0.640500             39.50            10 .0          56           16.5     oP         N      GND
     1.023000             36.10            10.0           56           19.9      QP        N      GND
     2.242500             36.10            10 .0          56           19.9      oP        N      GND
      207000              31.40            10.0           60           28.6      QP        N      GND
    13.974000             30 .00           10 .2          60           30.0      oP        N      GND




MEASUREMENT RESULT:                       "HTW10175045_fin2"

10/17/2018             5:15PM
    Frequency             Level         Transd        Limit      Margin         Detector   Line    PE
                 MEz       dBuV                  dB    dBpV                dB
     0.226500             43. 60           10.2           53            9.0         aV     N      GND
     0.753000             29.80             9. 9          46           16.2         AV     N      GND
     1.810500             29.40            10 .0          46           16.6         AV     N      GND
     2.746500             28.40            10 .0          46           17.6         AV     N      GND
      211500              26.00            10 .0          50           24.0         AV     N      GND
    14.041500             23.90            10 .2          50           26.1         AV     N      GND


Report No : TRE1810009704                       Page 13 of 18                              Issued: 2018-10-25



5.2. Radiated Emissions Test
LIMIT

FCC CFR Title 47 Part 15 Subpart B Section 15.109
              Frequency                       Limit (dBuV/m @3m)                              Value
             30MHz-88MHz                                   40.00                           Quasi-peak
             88MHz-216MHz                                  43.50                           Quasi-peak
            216MHz-960MHz                                  46.00                           Quasi-peak
             960MHz-1GHz                                   54.00                           Quasi-peak
                                                           54.00                             Average
              Above 1GHz
                                                           74.00                              Peak

TEST CONFIGURATION

    30MHz ~ 1GHz




    Above 1GHz




TEST PROCEDURE

1.   The EUT was tested according to ANSI C63.4:2014.
2.   The EUT is placed on a turn table which is 0.8 meter above ground.
3.   The turn table is rotated 360 degrees to determine the position of the maximum emission level.
4.   The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
5.   The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
     repeated for both horizontal and vertical polarization of the antenna.
6.   Use the following spectrum analyzer settings
     (1) Span shall wide enough to fully capture the emission being measured;
     (2) Below 1GHz,
          RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, theemission measurement will be repeated using
          the quasi-peak detector and reported.
     (3) From 1GHz to 5th harmonic, RBW=1MHz, VBW=3MHz

Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : TRE1810009704                     Page 14 of 18                           Issued: 2018-10-25


TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable


Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Shenzhen Huatongwei International Inspection Co., Ltd.            Report Template Version: V01 (2018-01)


         L evel        [dBuVim]
 so
 To
 co
 5o
 40
 30
 20
 10                         i       i                           i                                         i                       i
     o                      i.      i.                       i.                                         i.                    i.
                  om      40M      50M GOM 70M             Toom                       200M            3com        400M 500M 600M             800M 1G
                                                                             Frequency [z]
 x x xmes cmsromteiesrea


MEASUREMENT RESULT:                                 "GM1810176144_red"

10/18/2018   12:00aM
   Frequency     Level                             Transd           Limit      Margin        Det.         Height        Azimuth       Polarization
         MHz    dBpV/m                                 dB           dBuV/m         as                         cm            deg
        66.860000                        26.50      —11.9            40 .0        13.5       op               300.0      223.00        HORIZONTAL
       142.520000                        29.30      —13.7            43.5         14.2       op               300.0      122.00        HORIZONTAL
       204. 600000                       39.40      —10.1            43.5          4.1       oP               100.0      100.00        HORIZONTAL
       222.060000                        32.40       —9.5            46.0          6.6       oPp              100.0       88.00       HORIZONTAL
       251.160000                        34.10       —8.1            46.0         11.9       op               100.0      295.00        HORIZONTAL
       982.540000                        36.30        8.4            53.9         17.6       op               100.0      283.00        HORIZONTAL


                   80
                        Level (dBuVim)
                                                                                                                               ECC CLASS—B PK
                   70

                   60
                                                                                                                               FCC CLASS—B AV




                   20

                   10


                       61000      1200           1500                2000                                                             5000      6000
                                                                             Frequency (MHz)
Mark                    Frequency        Reading        Antenna       Cable        Preamp            Level             Limit      Over         Remark
                       MBZ               dBuy/m           dB            dB          dB              dBuy/m            dBuv/m     limit
                   1278.22                49.0           26.2           4.8        $7.%            42.8                74.0     ~§1:2           Peak
  o or e w to m




                   1584.84                 46.5          25.0           5.5        37.2            39.8                74.0     ~34.2           Peak
                   2338.00                 43.4          27.9           6.7        37.6            40.4                74.0     ~33.6           Peak
                   2737.29                 43.2          28.1           T.4        37.6            40.9                74.0     ~88.1           Peak
                   4052. 62                38.4          29.8           8.8        36.7            40.3                74.0     +38.7           Peak
                   4988.86                 33.6          31.5           Bd         35.4            39.4                74.0     —34.6           Peak


    Level [4ByVim]
  so
  70
  60

  50

  40                                       t

  30                                      1
  20                                      4
                   1                       1               1                                        1
  10               i
                   1
                             i
                             1
                                           i1              i1                                       i1          i
                                                                                                                1
                                                                                                                              i
                                                                                                                              1
   o               :         :             :               :                                        :           :             :
       30M     40M         50M     GOM 70M                100M                     200M          300M         400M     500M 600M     800M    1G
                                                                          Frequency [Hz]

 x x xmes              omle10176143_rea


MEASUREMENT RESULT:                              "GM1810176143_red"
10/17/2018                11: 549M
    Frequency                    Level          Transd           Limit     Margin       Det.    Height         Azimuth        Polarization
               MHz           dBpV/m                 dB          dBpV/m           ds                      cm            deg
   35. 820000                    35.10           —11.6            40.0         4.9      P           100.0           333.00     VERTICAL
   61.040000                     27 .30          ~10.2            40.0        12.7      P           100.0           344.00     VERTICAL
   94.020000                     27 .90          ~11.4            43.5        15.6      P           100.0            78.00    VERTICAL
  127.000000                     36.60           ~12.8            43.5         6.9      P           100.0            68.00     VERTICAL
  198.780000                     33.10            —9.5            43.5        10.4      P           100.0           248.00    VERTICAL
 1000.000000                     36.70             8. 6           53.9        17.2      oP          100.0            52.00    VERTICAL



            Level (dBuVim)
       80
                                                                                                                             ECC CLASS—B PK
       70

       60
                                                                                                                             FCC CLASS—B AV




       20

       10


            1000        1200              1500                    2000                                                             5000      6000
                                                                         Frequency (MHz)
Mark         Frequency            Reading          Antenna          Cable        Preamp         Level               Limit     Over          Remark
                MHZ               dBuv/m             dB              dB           dB           dBuv/m          dBuv/m        limit
   1        1280.52                 47.8            26.2             4.8         37.2        41.6                   74.0     —32.4           Peak
   2        1607.72                 43.6            24.9             5.6         37.2        36.9                   74.0     ~87.1           Peak
   3        2489.31                 42.8            27.2             6.8         37.6        39.2                   74.0     —34.8           Peak
   4        3108.64                 39.5            28.8             7.6         37.5        38.4                   74.0     ~35.6           Peak
   5        3646.07                 39.1            29.3             8.3         37.0        39.7                   74.0     —34.3           Peak
   6        4988.86                 35.8            31.5             $.7         35.4        41.6                   74.0     —32.4           Peak




                                                                                                    mlopes someemien n ne es


Report No : TRE1810009704                     Page 17 of 18                      Issued: 2018-10-25



6. TEST SETUP PHOTOS OF THE EUT
Conducted Emissions (AC Mains)




Radiated Emissions (30MHz-1GHz)




Radiated Emissions (Above 1GHz)




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : TRE1810009704                     Page 18 of 18                        Issued: 2018-10-25



7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT
    Reference to the test report No.: TRE1810009701.


                                        --------End of Report--------




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)



Document Created: 2018-11-09 08:31:25
Document Modified: 2018-11-09 08:31:25

© 2024 FCC.report