Test report

FCC ID: 2ABOSSKYTANK2

Test Report

Download: PDF
FCCID_4338738

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE190411303

1        Cover Page

                                      FCC REPORT
Applicant:                                 Sky Phone LLC

Address of Applicant:                      1348 Washington Av.Suite 350 ,Miami Beach,Florida,United
                                           States
Equipment Under Test (EUT)

    Product Name:                          Feature Phone

    Model No.:                             SKY TANK2

    Trade mark:                            SKY DEVICES

FCC ID:                                    2ABOSSKYTANK2

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    26 Apr., 2019

Date of Test:                              26 Apr., to 08 May., 2019

Date of report issued:                     09 May., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE190411303

2      Version
      Version No.                            Date                                  Description
             00                        09 May., 2019                                 Original




    Tested by:                                                           Date:          09 May., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          09 May., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1904113
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 18


                                                                                                                            Report No: CCISE190411303

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1904113
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE190411303

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1904113
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                              Report No: CCISE190411303

5      General Information
5.1 Client Information
        Applicant:                        Sky Phone LLC
        Address:                          1348 Washington Av. Suite 350, Miami Beach, Florida, United States
        Manufacturer:                     Sky Phone LLC
        Address:                          1348 Washington Av. Suite 350, Miami Beach, Florida, United States

5.2 General Description of E.U.T.
        Product Name:                           Feature Phone
        Model No.:                              SKY TANK2
        Power supply:                           Rechargeable Li-ion Battery DC3.7V-2500mAh
                                                Model: SKY Tank2
        AC adapter :                            Input: AC100-240V, 50/60Hz, 0.15A
                                                Output: DC 5.0V, 500mA
        Test Sample Condition:                  The test samples were provided in good working order with no
                                                visible defects.

5.3 Test Mode
           Operating mode               Detail description
              PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode             Keep the EUT in Charging+Recording mode
      Charging+Playing mode             Keep the EUT in Charging+Playing mode
             FM mode                  Keep the EUT in FM receiver mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                    Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                    ±1.60 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                    ±3.12 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                   ±4.54 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     ±5.84 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                    ±3.36 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1904113
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 5 of 18


CCIS                                                                            Report No: CCISE190411303

5.5 Description of Support Units
      Manufacturer                Description                 Model          Serial Number           FCC ID/DoC

          DELL                         PC                 OPTIPLEX745               N/A                  DoC
          DELL                     MONITOR                   E178FPC                N/A                  DoC
          DELL                    KEYBOARD                   SK—8115                N/A                  DoC
          DELL                      MOUSE                    MOCSUO                 N/A                  DoC
        LENOVO                       Laptop                   SL510              2B47A65                 DoC

5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
        Cable Type                     Description                 Length           From                  To
   Detached USB Cable                   Unshielded                  0.8m             EUT              PC/Adapter

5.8 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ®   FCC — Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
       ®   IC — Registration No.: 10106A—1
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A—1.
       ® CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of testing.
       The Registration No. is CNAS L6048.
       ® A2LA — Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https:{portal.a2la.ora/scopepdf/4348—0 LLpdf

5.9 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
       Email: info@ccis—cb.com, Website: http//www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1904113
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 6 of 18


                                                                                  Report No: CCISE190411303

5.10 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m               966         07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-18-2019         03-17-2020
   BiConiLog Antenna         SCHWARZBECK               VULB9163               497         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D               916         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358       03-18-2019         03-17-2020
     Pre-amplifier                 CD                  PAP-1G18             11804         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070        03-18-2019         03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458        03-18-2019         03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5       03-18-2019         03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE       03-18-2019         03-17-2020


 Conducted Emission:
                                                                                         Cal. Date          Cal. Due date
   Test Equipment             Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189       03-18-2019           03-17-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731        03-18-2019           03-17-2020
        LISN                    CHASE                 MN2050D               1447        03-18-2019           03-17-2020
        LISN                Rohde & Schwarz           ESH3-Z5            8438621/010    07-21-2018           07-20-2019
       Cable                      HP                   10503A                N/A        03-18-2019           03-17-2020
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1904113
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                              Report No: CCISE190411303

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Method:                     ANSI C63.4:2014
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                Average
                                                 0.15-0.5                   66 to 56*               56 to 46*
                                                   0.5-5                       56                      46
                                                  0.5-30                       60                      50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1904113
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


CCIS                                                                                           Report No: CCISE190411303

Measurement data:

 Product name:                         Feature Phone                     Product model:              SKY TANK2

 Test by:                              Yuro                              Test mode:                  PC mode

 Test frequency:                       150 kHz ~ 30 MHz                  Phase:                      Line

 Test voltage:                         AC 120 V/60 Hz                    Environment:                Temp: 22.5°C        Huni: 55%


    80 Level (dBuV)



    70

    60                                                                                                           FCC PART1S B QP

    50   ~~~—
           J  ».fi__xq_k                       —                                                                  FCC PART15B AV
                                                         g               y
    40                                        |
                                              N
    30|| —                                                   0            h
             ’\J 4\         v"'l‘mw,
    20            Papogt|          N                             WA          WMM   xX
    10                                                                          itt C

         156 .2                                                         2                  5                10           20        30
 ,,,,, a~=                                                        Frequency (MHz)


                                   Read   LISN         Cable             Limit       Over
                      Freq        Level Factor           Loss    Level    Line      Limit Remark

              ______MHz dBu¥y — dB — dB dBu¥f dBu¥ —                                       dB
      1               D.154       40.14       —0.456   10.78     50.47   65.78    —15.31   QP
      2               0.154       20.09       —O.4§    10.78     30.42   55.78    —25.36   Average
      3               D.186       35.96       —0.42    10.76     46.30   64.20    —17.90   qP
      4               D.461       18.04       —0.38    10.74     28.40   46.67    —18.27   Average
      5               D.558       33.54       —0.39    10.76     43.91   56.00    —12.09   qP
      6               D.558       22.00       —0.39%   10.76     32.37   46.00    —13.63   Average
      7               0.598       34.13       —0.38    10.77     44.52   56.00    —11.48   QP
      8               0.598       20.36       —0.38    10.77     30.75   46.00    —15.25   Average
      9               1.016       I1.14       —0.38    10.87     41.63   56.00    —14.37   QP
     10               1.111       17.93       —0.38    10.88     28.43   46.00    —17.57   Average
     11               2.144       33.02       —0.42    10.95     43.55   56.00    —12.45   QP
     12               2.178       18.02       —0.42    10.956    28.55   46.00    —17.45   Average



 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                           Project No.: CCISE1904113
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                             Page 9 of 18


CCIS                                                                               Report No: CCISE190411303


 Product name:               Feature Phone                     Product model:            SKY TANK2

 Test by:                    Yuro                              Test mode:                PC mode

 Test frequency:             150 kHz ~ 30 MHz                  Phase:                    Neutral

 Test voltage:               AC 120 V/60 Hz                    Environment:              Temp: 22.5°C       Huni: 55%


          Level (dBuV)
     80

     70

                                                                                                   FCC PART15 B QP
     50\
                                                                                                   FCC PART15B AV
     5011

     40

     30

     20

     10




 Trumee 4 5                                             Frequency (MHz)

                           Read       LISN     Cable               Limit        Over
                  Freq    Level Factor           Loss    Level       Line     Linmit Remark

                   MHz     dBu¥y         dB        dB      dBu¥      dBu¥         dB

     1           0.158    37.34     —0.68      10.77     47.43     65.56    —18.13     qP
     2           0.194    19.30     —0.69      10.76     29.37     53.84    —24.47     &verage
     3           0. 581   39.79     —0.65      10.76     49.90     56.00     —6.10     qP
     4           0.561    23.08     —0.65      10.76     33.18     46.00    —12.81     Average
     5           0.595    38.62     —O.64      10.77     48.75     56.00     —T.25     qP
     &           0.595    24.22     —0.64      10.77     34.35     46.00    —11.65     &verage
     T           1.088    I6.41     —0.63      10.88     46.66     56.00     —8.3%     QP
     8           l.111    18.96     —O0.64     10.88     29.20     46.00    —16.80     Awerage
     9           2.167    38.38     —O.67      10.95§    48.66     56.00     —7.34     QP
    10           2.249    20.68     —O.67      10.95     30.96     46.00    —15.04     Average
    11           3.720    36.89     —0.89      10.90     47.10     56.00     —8.90     qP
    12           3.720    17.37     —0.68      10.90     27.58     46.00    —18.42     &verage


 Notes:
 1. An initial pre—scan was performed on the line and neutrallines with peak detector.
 2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1904113
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                Page 10 of 18


                                                                         Report No: CCISE190411303

6.2 Radiated Emission
        Test Requirement:             FCC Part 15 B Section 15.109
        Test Method:                  ANSI C63.4:2014
        Test Frequency Range:         30MHz to 6000MHz
        Test site:                    Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                 Frequency       Detector        RBW      VBW           Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz    Quasi-peak Value
                                                         Peak           1MHz     3MHz       Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz      Average Value
        Limit:                               Frequency           Limit (dBuV/m @3m)          Remark
                                           30MHz-88MHz                    40.0           Quasi-peak Value
                                          88MHz-216MHz                    43.5           Quasi-peak Value
                                          216MHz-960MHz                   46.0           Quasi-peak Value
                                           960MHz-1GHz                    54.0           Quasi-peak Value
                                                                          54.0            Average Value
                                            Above 1GHz
                                                                          74.0             Peak Value
        Test setup:                   Below 1GHz




                                      Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1904113
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                    Page 11 of 18


                                                                               Report No: CCISE190411303


        Test Procedure:                 1. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the ground at a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of
                                           the EUT would be reported. Otherwise the emissions that did not have
                                           10dB margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
        Test environment:               Temp.:        24 C         Humid.:    57%         Press.:    1 01kPa
        Test Instruments:               Refer to section 5.9 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         All of the observed value above 6GHz ware the niose floor , which were
                                        no recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1904113
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


CCIS                                                                                      Report No: CCISE190411303

Measurement Data:
Below 1GHz:

 Product Name:               Feature Phone                              Product Model:          SKY TANK2

 Test By:                    Yuro                                       Test mode:              PC mode

 Test Frequency:             30 MHz ~ 1 GHz                             Polarization:           Vertical

 Test Voltage:               AC 120/60Hz                                Environment:            Temp: 24°C       Huni: 57%


      so Level (dBuV/im)


      70

      60
                                                                                                    FCC PART1S CLASS B
      50                                                                                          z                   ’V

      40

      30

      20

      10


       030             50                      100                     200                          500             1000
                                                            Frequency (MHz)

                             Readantenna         Cable Preamp                    Linmit      Over
                 Freq       Level Factor             Loss Factor        Level     Line      Limit Remark

           ______NHz        dBu¥ dB/m                 dB — dB dBu¥/m dBuV/m —                         dB
      1       60.704        53.94    11.12           1.38     29.77    36.67     40.00 —3.33 QP
      2      120.699        51.31    10.85           2.18     29.39    34.95     43.50 —8.55 qQP
      3      148.441        49.61      8. 97         2.50      29.23   31.85     43.50 —11.65 qQP
      4      293.081        42.66    13.50           292      28.46    30.62     46.00 —15.38 QP
      5      480.528        §2.80    17. 52          3.46     28.92    44.86     46.00 —1.14 QP
      6      996.500        36.71    22.79           4.45     27.45    36.52     54.00 —17.48 QP


 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1904113
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                     Page 13 of 18


c c I s                                                                                   Report No: CCISE190411303



 Product Name:               Feature Phone                              Product Model:            SKY TANK2

Test By:                     Yuro                                       Test mode:                PC mode

Test Frequency:              30 MHz ~ 1 GHz                             Polarization:             Horizontal

Test Voltage:                AC 120/60H2z                               Environment:              Temp: 24°C      Huni: 57%


      so Level (dBuV/im)



      70

      60
                                                                                                       FCC PART1S CLASS B
      50                                                                                               <

      40

      30

      20

      10


       030              50                      100                     200                            500             1000
                                                             Frequency (MHz)

                              Read&intenna        Cable Preamp                    Limit         Over
                   Freq      Level Factor             Loss Factor        Level          Line   Limit Remark

             ______NHz       dBu¥ dB/m — dB _dB dBuV/m dBu¥/m                                       dB
       1        60.492       42.13     11.21          1.38     29.77     24.95    40.00 —15.05             QP
       2       180. 017      47. 91     9. 98         2.13     28.97     G31.65   43.50—11.85              QP
       3       239.987       44.49     12.30          2.82     38.59.    31.02    46.00 —14.98             QP
       4       289.002       45.87     13.41          2.91     28.47     33.72    46.00 —12.28             QP
       5       480.528       §3.02     17.52          3.46     28.92     45.08    46.00 —0.92              QP
       6      1000. 000      35. 84    22. 80         4.47     21.43     35.68    54.00 —18.32             QP


 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   _The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1904113
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                      Page 14 of 18


c c I s                                                                                                    Report No: CCISE190411303

Above 1GHz:

 Product Name:                    Feature Phone                                           Product Model:         SKY TANK2

 Test By:                         Yuro                                                    Test mode:             PC mode

 Test Frequency:                  1 GHz ~ 6 GHz                                           Polarization:          Vertical

 Test Voltage:                    AC 120/60Hz                                             Environment:           Temp: 24°C           Huni: 57%


    8[}Level (dBuV/im})
                                                                                                                        FCC PART 15 (PK)
    70

    60
                                                                                                                        FCC PART 15 (AV)
    50

    40

    30

    20

    10


            G‘llf)Ol]   1200          1500                       2000                                                          5000       6000
                                                                                Frequency (MHz)

                                  Readintenna          Cable Preamp                                Limit      Over
                          Freq   Level Factor            Loss Factor                      Level      Line    Limit Remark



                                                                          «21    41.57)   31.93    74.00    —36.07   Fesk
     s Cn BC3 o +




                                                       —1 —1 0 o) on on




                                                                          «27    41.57    28.28    54.00    —25.72   Average
                                                                          34.    41.81    42.21    74.00    —31.79   Pesk
                                                                          «34    41.81    32.11    54.00    —21.89   Average
                    Ees
                    —
                    C
                    Co
                          C
                          —
                          to

                                 Co
                                 —1

                                      ho
                                      on

                                             Co
                                             C
                                                  Co
                                                  Co




                                                                          &23    41.82    45.38    74.00    —28.62   Peak
                                                                          &23    41.82    35.10    54.00    —18.90   Average


 Remark:
 1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                     Project No.: CCISE1904113
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                       Page 15 of 18


c c I s                                                                                Report No: CCISE190411303



 Product Name:              Feature Phone                             Product Model:            SKY TANKZ2

 Test By:                   Yuro                                      Test mode:                 PC mode

 Test Frequency:            1 GHz ~ 6 GHz                             Polarization:             Horizontal
 Test Voltage:              AC 120/60Hz                               Environment:              Temp: 24°C          Huni: 57%


      so Level (dBuV/im)
                                                                                                       FCC PART 15 (PK)
      70

      60
                                                                                                       FCC PART 15 (AV)
      50                                                                                                                5

      40

      30

      20

      10


           1000   1200          1500               2000                                                      5000       6000
                                                          Frequency (MHz)

                            Read&ntenna        Cable Preamp                   Limit      Over
                  Freq     Level Factor          Loss Factor        Level       Line    Linit Remark

           ______NHz       dBu¥ dB/m — dB — dB dBuV/m dBu¥/m                               dB
      1      2930.156      47.29     28.36       5.28     41.56     39.37     74.00    —34.63    Peak
      2      2930.156      37.33     28.36       5.28     41.56     29.41     54.00    —24.59    Average
      3       4030.897     48.60     30.31       6.15     41.81     43.25     74.00    —30.75    Peak
      4      4030.897      37.51     30.31       6.15     41.81     32.16     54.00    —21.84    Average
      5      5T88. T96     4T.86     32.66       T.89     42.02     46.39     74.00    —27.61    Peak
      6      5788. 796     37.37     32.66       T.89     42.02     35.90     54.00    —18.10    Average


 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1904113
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                     Page 16 of 18



Document Created: 2019-06-26 18:03:46
Document Modified: 2019-06-26 18:03:46

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC