Test report

FCC ID: 2ABOSSKYPLATC55

Test Report

Download: PDF
FCCID_4303297

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE190308005

1        Cover Page

                                      FCC REPORT
Applicant:                                 SKY PHONE LLC

Address of Applicant:                      1348 Washington Av. Suite 350, Miami Beach, FL 33139

Equipment Under Test (EUT)

    Product Name:                          3G Smart Phone

    Model No.:                             Platinum C55

    Trade mark:                            SKY DEVICES

FCC ID:                                    2ABOSSKYPLATC55

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    26 Mar., 2019

Date of Test:                              26 Mar., to 28 Apr., 2019

Date of report issued:                     29 Apr., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE190308005

2      Version
      Version No.                            Date                                  Description
             00                         29 Apr., 2019                                Original




    Tested by:                                                           Date:          29 Apr., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          29 Apr., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1903080
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 18


                                                                                                                            Report No: CCISE190308005

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1903080
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE190308005

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1903080
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                              Report No: CCISE190308005

5      General Information
5.1 Client Information
        Applicant:                        SKY PHONE LLC
        Address:                          1348 Washington Av. Suite 350, Miami Beach, FL 33139
        Manufacturer:                     SKY PHONE LLC
        Address:                          1348 Washington Av. Suite 350, Miami Beach, FL 33139

5.2 General Description of E.U.T.
        Product Name:                     3G Smart Phone
        Model No.:                        Platinum C55
        Power supply:                     Rechargeable Li-ion Battery DC3.8V-2500mAh
                                          Model: S5519
        AC adapter :                      Input: AC100-240V, 50/60Hz, 0.2A
                                          Output: DC 5.0V, 1A
        Test Sample Condition:            The test samples were provided in good working order with no visible
                                          defects.

5.3 Test Mode
           Operating mode               Detail description
              PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode             Keep the EUT in Charging+Recording mode
      Charging+Playing mode             Keep the EUT in Charging+Playing mode
              FM mode                   Keep the EUT in FM receiver mode
            GPS mode                  Keep the EUT in GPS receiver mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                    Parameters                                             Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                     ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                     ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                    ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                      ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                     ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1903080
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 5 of 18


CCIS                                                                            Report No: CCISE190308005

5.5 Description of Support Units
      Manufacturer                Description                 Model          Serial Number          FCC ID/DoC

           DELL                        PC                 OPTIPLEX745              N/A                  DoC
           DELL                    MONITOR                   E178FPC               N/A                  DoC
           DELL                   KEYBOARD                   SK—8115               N/A                  DoC
           DELL                     MOUSE                    MOCSUO                N/A                  DoC
        LENOVO                       Laptop                   SL510              2B47A65                DoC

5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
        Cable Type                     Description                 Length           From                 To
   Detached USB Cable                    Shielding                  1.0m             EUT             PC/Adapter
  Detached headset cable                Unshielded                  1.0m             EUT              Headset

5.8 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ®   FCC — Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
       ®    IC — Registration No.: 10106A—1
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A—1.
       ® CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of testing.
       The Registration No. is CNAS L6048.
       ® A2LA — Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la. org/scopepdf/4346—0 1 .pdf

5.9 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
       Email: info@ccis—cb.com, Website: http//www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1903080
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 6 of 18


                                                                                  Report No: CCISE190308005

5.10 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m               966         07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-18-2019         03-17-2020
   BiConiLog Antenna         SCHWARZBECK               VULB9163               497         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D               916         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358       03-18-2019         03-17-2020
     Pre-amplifier                 CD                  PAP-1G18             11804         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070        03-18-2019         03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458        03-18-2019         03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5       03-18-2019         03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE       03-18-2019         03-17-2020


 Conducted Emission:
                                                                                         Cal. Date          Cal. Due date
   Test Equipment             Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189       03-18-2019           03-17-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731        03-18-2019           03-17-2020
        LISN                    CHASE                 MN2050D               1447        03-18-2019           03-17-2020
        LISN                Rohde & Schwarz           ESH3-Z5            8438621/010    07-21-2018           07-20-2019
       Cable                      HP                   10503A                N/A        03-18-2019           03-17-2020
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1903080
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                              Report No: CCISE190308005

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Method:                     ANSI C63.4:2014
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                Average
                                                 0.15-0.5                   66 to 56*               56 to 46*
                                                   0.5-5                       56                      46
                                                  0.5-30                       60                      50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1903080
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


c c I s                                                                                      Report No: CCISE190308005

Measurement data:
 Product name:                        3G Smart Phone                      Product model:           Platinum C55

 Test by:                             Carey                               Test mode:               PC mode

 Test frequency:                      150 kHz ~ 30 MHz                    Phase:                   Line

 Test voltage:                        AC 120 V/60 Hz                      Environment:             Temp: 22.5°C     Huni: 55%


      so Level (dBuV)


      70
      60                                                                                                  FCC PART1S B OP

           ~——               3\              _8                                                           FCC PARTIS B AV
      50                      E—i                      9|11          12
                    l            4)       NJ i         m
      40        4                                 lg

      30    [                         (                |


      20   at “‘U*A'LJV |                                      M’          ,
                                                                                                             *
      10                                                                                                          *~“\»A“M

       "1s 3                                5                1         2                    5         10            20      30
                                            Read            LISN   Cable                   Limit      Over
                         Freq         Level Factor                  Loss       Level        Line    Linit Remark

            ______NHz                     dBu¥ — dB _ dB dBu¥ dBu¥ —                                          dB
       1                0.194         40.09                —O.41   10.76       50.44       63.84   —13.40     QP
       2                0.194         27.90                —O.41   10.76       38.25       53.84   —15.59     Average
       3                0. 377        39.63                —O.37   10.72       49.98       58.34    —8.36     QP
       4                0. 393        30.57                —0.37   10.72       40.92       47.99    —7.07     Average
       5                0.461         28.06                —0.38   10.74       38.42       46.67    —8.25     Average
       6                0.502         40.29                —0.39   10.76       50.66       56.00    —5.34     QP
       T                0.505         29.10                —0.39   10.76       39.47       46.00    —6.53     Average
       8                0. 654        24.85                —0.38   10.77       35.24       46.00   —10.76     &verage
       9                0. 759        36.24                —0.38   10.80       46.66       56.00    —9.34     QP
      10                0.923         22.95                —0.38   10.85       33.42       46.00   —12.58     Average
      11                1.010         36.02                —0.38   10.87       46.51       56.00    —9.49     QP
      12                1.888         35.07                —O.41   10.95       45.61       56.00   —10.39     QP

 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.    Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1903080
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 9 of 18


c c I s                                                                              Report No: CCISE190308005


 Product name:               3G Smart Phone                    Product model:             Platinum C55

Test by:                     Carey                             Test mode:                 PC mode

Test frequency:              150 kHz ~ 30 MHz                  Phase:                     Neutral

Test voltage:                AC 120 V/60 Hz                    Environment:               Temp: 22.5°C       Huni: 55%


  80 Level (dBuV)


  70

  6o                                                                                                FCC PART1S B QP
                        35     6
  50       1                                                                                        FCC PART15B AV


  40   W!umlmw's
  *&JM»NV W'W
      o




  10

      "As 3                   5       1                    2                     5           10      20               30
                              Read    LISN             Cable                     Limnit       Over
                  Freq       Level Factor                Loss       Level          Line     Linit Remark

          """"WHz dBu¥y — dB _ dB dBu¥ dBu¥ —                                                            dB
   1            0. 190       39.68        —0.69         10.76       49.75        64.02    —14.27         QP
   2            0.194        27.02        —0.69         10.76       37.09        53.84    —16.75         &verage
   3            0.3717       42.99        —0.64         10.72       53.07        58.3      —5.27         9P
   4            0.377        30.63        —0.64         10.72       40.71        48.34     —7.63         Average
   5            0.402        42.57        —0.64         10.72       52.656       57.81     —5.16         qP
   6            0.502        43.71        —0.65         10.76       53.82        56.00     —2.18         qP
   T            0.502        30.45        —0.65         10.76       40.56        46.00     —5.44         Average
   8            0. 759       39.62        —O.64         10.830      49.78        56.00     —6.22         qP
   9            0. 7569      24.66        —0.64         10.80       34.82        46.00    —11.18         Average
  10            1.000        39.20        —0.63         10.87       49.44        56.00     —6.56         qP
  11            1.0056       24.97        —0.63         10.87       35.21        46.00    —10.79         Average
  12            1.698        21.56        —0.66         10.94       31.84        46.00    —14.16         &Average

 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1903080
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                 Page 10 of 18


                                                                         Report No: CCISE190308005

6.2 Radiated Emission
        Test Requirement:             FCC Part 15 B Section 15.109
        Test Method:                  ANSI C63.4:2014
        Test Frequency Range:         30MHz to 6000MHz
        Test site:                    Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                 Frequency       Detector        RBW      VBW           Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz    Quasi-peak Value
                                                         Peak           1MHz     3MHz       Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz      Average Value
        Limit:                               Frequency           Limit (dBuV/m @3m)          Remark
                                           30MHz-88MHz                    40.0           Quasi-peak Value
                                          88MHz-216MHz                    43.5           Quasi-peak Value
                                          216MHz-960MHz                   46.0           Quasi-peak Value
                                           960MHz-1GHz                    54.0           Quasi-peak Value
                                                                          54.0            Average Value
                                            Above 1GHz
                                                                          74.0             Peak Value
        Test setup:                   Below 1GHz




                                      Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1903080
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                    Page 11 of 18


                                                                               Report No: CCISE190308005


        Test Procedure:                 1. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the ground at a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of
                                           the EUT would be reported. Otherwise the emissions that did not have
                                           10dB margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
        Test Instruments:               Refer to section 5.9 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         All of the observed value above 6GHz ware the niose floor , which were
                                        no recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1903080
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


c c I s                                                                                    Report No: CCISE190308005

Measurement Data:
Below 1GHz:

 Product Name:                  3G Smart Phone                            Product model:            Platinum C§5

Test By:                        Carey                                     Test mode:                PC mode

Test Frequency:                 30 MHz ~1 GHz                             Polarization:             Vertical

Test Voltage:                   AC 120/60Hz                               Environment:              Temp: 24°C      Huni: 57%


  so Level (dBuVim)


  70

  60
                                                                                                       FCC PART1S CLASS B
  50

  40

  30

  20

  10


      030                50                     100                    200                             500               1000
                                                           Frequency (MHz)
                                Read&ntenna            Cable Preamp                       Limit       Over
                     Freq      Level Factor              Loss Factor          Level         Line     Limit Remark

             """NHz —dBu¥y                   dB/mn          dB _        dB dBu¥/m dBu¥/n                     dB
      1           30.000        54.99      10.60         0.72      29.98      36.33       40.00      —3.67 QP
      2         207.850        49.21       10.96         2.86      28.18      M.25        43.50      —9.25 QP
      3         416.179        51.86       15.69         3.12      28.81      41.86       46.00      —4.14 QP
      4         480.528        45.69       17.52         3.46      28.92      37.7T5      46.00      —8.25 QP
      5          T2l.726       40.33       20.49        4.26       28.58      36.50       46.00      —9.50 QP
      6          962.162       40.74       22.73        4.27       27.65      40.09       54.00 —13.91 QP


 Remark:
 1.       Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.       The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1903080
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 13 of 18


c c I s                                                                                   Report No: CCISE190308005



 Product Name:                  3G Smart Phone                           Product model:              Platinum C55

 Test By:                       Carey                                    Test mode:                  PC mode

 Test Frequency:                30 MHz ~ 1 GHz                           Polarization:               Horizontal

 Test Voltage:                  AC 120/60Hz                              Environment:                Temp: 24°C     Huni: 57%


            Level (dBuVim)
      80,

      70

      60
                                                                                                      FCC PART1S CLASS B
      50

      40
            }|                                                                                   3                        ¢

      30


      20

      10


            30            50                    100                    200                            500                1000
                                                           Frequency (MHz)
                                 Readintenna          Cable Preamp                       Limit         Over
                     Freq      Level Factor              Loss Factor         Level         Line       Linit Remark

                       MHz        dBu¥        dB/n         dB          dB dBu¥/m dBu¥/m                     dB
      1          207.850       55.03       10.96        2.86      28.78       40.07      43.50 —3.43 QP
      2          263.819       43.28       12.97        2.85      28.51       30.59      46.00 —15.41 QP
      3          416.179       51.03       15.69        3.12      28.81       41.03      46.00 —4.97 QP
      4          480.528       46.05       17.52        3.46      28.92       38.11      46.00 —7.89 QP
      5          625.078       40.80       19.61        3.90      28.86       35.45      46.00 —10.55 QP
      6          962.162       43.51       22.73        4.27      27.65       42.86      54.00 —11.14 qP

 Remark:
 1.       Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.       The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1903080
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 14 of 18


CCIS                                                                                       Report No: CCISE190308005

Above 1GHz:
 Product Name:                  3G Smart Phone                            Product model:            Platinum C55

 Test By:                       Carey                                     Test mode:                PC mode

 Test Frequency:                1 GHz ~ 6 GHz                             Polarization:             Vertical

 Test Voltage:                  AC 120/60Hz                               Environment:              Temp: 24°C          Huni: 57%


  80I_evel (dBuVim)
                                                                                                           FCC PART 15 (PK)
  70

  60
                                                                                                           FCC PART 15 (AV)
  50                                                                                                4               5
                                                                                       1
  40

  30

  20

  10


      G1000        1200           1500               2000                                                        5000       6000
                                                            Frequency (MHz)
                                Readintenna            Cable Preamp                        Limit         Over
                     Freq      Level Factor              Loss Factor           Level         Line       Limit Remark

                  _WEz _ dBu¥y               db/m           dB          dB dBu¥/m dBu¥/m —dB _
      1        3239.211        49.01       28.55         5.47      41.40       43.68       74.00 —30.32 Peak
      2        3239.211        40.73       28.55         5.47      41.40       35.40       54.00 —18.60 Average
      3         3981.251       49.94       30.23         6.11      41.81       46.67       74.00 —27.33 Peak
      4        3981.251        40.73       30.23         6.11      41.81       37.46       54.00 —16.54 Average
      5        5248. 359       49.46       32.02         T.09      41.93       49.22       74.00 —24.78 Peak
      6        5248. 359       39.76       32.02         T.09      41.93       39.52       54.00 —14.48 Average

 Remark:
 1.       Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
 2.       The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1903080
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 15 of 18


CCIS                                                                                       Report No: CCISE190308005


 Product Name:                  3G Smart Phone                            Product model:            Platinum C§5

Test By:                        Carey                                     Test mode:                PC mode

Test Frequency:                 1 GHz ~6 GHz                              Polarization:             Horizontal

Test Voltage:                   AC 120/60Hz                               Environment:              Temp: 24°C          Huni: 57%


      so Level (dBuVim)
                                                                                                           FCC PART 15 (PK)
      70

      60
                                                                                                           FCC PART 15 (AV)
      50

  AOWWM
                                                                                 3
      30


      20


      10


       G1000       1200           1500               2000                                                        5000       6000
                                                            Frequency (MHz)

                                Readintenna            Cable Preamp                        Linit        Over
                     Freq      Level Factor              Loss Factor           Level        Line       Limit Renark

            ——————WHz dBu¥y dB/m — dB _ dB dBu¥/m dBu¥/m                                                  dB
      1       3002.482         46.81       28.50         5.35      41.51       41.05       74.00     —32.95      Peak
      2        3002.482        36.75       28.50         5.35      41.51       30.99       54.00     —23.01      Average
      3        3675.958        46.86       29.22         5.96      41.63       42.61       74.00     —31.39      Peak
      4        3675.958        36.78       29.22         5.96      41.63       32.53       54.00     —21.47      Average
      §        4941.121        46.98       31.29         6.90      41.86       45.79       74.00     —28.21      Peak
      6        4941.121        36.84       31.29         6.90      41.86       35.65       54.00     —18.35      Average

 Remark:
 1.       Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.       The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1903080
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 16 of 18



Document Created: 2019-05-28 18:00:08
Document Modified: 2019-05-28 18:00:08

© 2025 FCC.report