Test report

FCC ID: 2ABOSSKYPLATB5

Test Report

Download: PDF
FCCID_3940348

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE180601105

1        Cover Page

                                      FCC REPORT
Applicant:                                 Sky Phone LLC

Address of Applicant:                      1348 Washington Av. Suite 350, Miami Beach, Florida, United
                                           States
Equipment Under Test (EUT)

    Product Name:                          Smart phone

    Model No.:                             Platinum B5

    Trade mark:                            SKY DEVICES

FCC ID:                                    2ABOSSKYPLATB5

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    04 Jun., 2018

Date of Test:                              05 Jun., to 26 Jun., 2018

Date of report issued:                     27 Jun., 2018

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE180601105

2      Version
      Version No.                        Date                                    Description
            00                     27 Jun., 2018                                   Original




    Tested by:                                                           Date:          27 Jun., 2018

                                       Test Engineer

    Reviewed by:                                                         Date:          27 Jun., 2018

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 2 of 18


                                                                                                                           Report No: CCISE180601105

3         Contents
                                                                                                                                                                                Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1   CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2   GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3   TEST MODE.................................................................................................................................................................... 5
    5.4   MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5   DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6   RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7   LABORATORY FACILITY ...................................................................................................................................................... 6
    5.8   LABORATORY LOCATION ................................................................................................................................................... 6
    5.9   TEST INSTRUMENTS LIST.................................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1   CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2   RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                              Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                       Page 3 of 18


                                                                              Report No: CCISE180601105

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


c c I s                                                                       Report No: CCISE180601105

5       General Information
5.1 Client Information
       Applicant:                              Sky Phone LLC
       Address of Applicant:                   1348 Washington Av. Suite 350, Miami Beach, Florida, United States
       Manufacturer/ Factory:                  Sky Phone LLC
       Address:                                1348 Washington Av. Suite 350, Miami Beach, Florida, United States

5.2 General Description of E.U.T.
       Product Name:                           Smart phone
       Madel No.:                              Platinum B5
       Power supply:                           Rechargeable Li—ion Battery DC3.7V—2000mAh
                                               Model: TPA—46B050100UU
       AC adapter :                            Input: AC100—240V, 50/60H2z, 0.2A
                                               Output: DC 5.0V, 1000mA


5.3 Test Mode
         Operating mode                Detail description
             PC made                   Keep the EUT in Downloading made(Worst case)
    Charging+Recording mode            Keep the EUT in Charging+Recording mode
     Charging+Playing made             Keep the EUT in Charging+Playing made
             FM made                   Keep the EUT in FM receiver mode
            GPS mode                   Keep the EUT in GPS receiver mode
The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
vertical polarities were performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying
antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst—case are shown
in Test Results of the following pages.

5.4 Measurement Uncertainty
                   Parameters                                             Expanded Uncertainty
       Conducted Emission (@kHz ~ 30MHz)                                     £2.22 dB (k=2)
        Radiated Emission (QkHz ~ SOMHz)                                     +2.76 dB (k=2)
      Radiated Emission (30MHz ~ 1000MHz)                                    +4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     +5.72 dB (k=2)
       Radiated Emission (18GHz ~ 40GHz)                                     +2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1806011
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                           Page 5 of 18


                                                                           Report No: CCISE180601105

5.5 Description of Support Units
      Manufacturer                 Description                 Model     Serial Number         FCC ID/DoC
           DELL                         PC                OPTIPLEX745          N/A                  DoC
           DELL                     MONITOR                  E178FPC           N/A                  DoC
           DELL                   KEYBOARD                    SK-8115          N/A                  DoC
           DELL                      MOUSE                   MOC5UO            N/A                  DoC
         LENOVO                       Laptop                   SL510        2847A65                 DoC

5.6 Related Submittal(s) / Grant (s)
        This is an original grant, no related submittals and grants.

5.7 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
         FCC - Registration No.: 727551
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
        (Federal Communications Commission). The Registration No. is 727551.
         IC - Registration No.: 10106A-1
        The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
        with Registration No.: 10106A-1.
         CNAS - Registration No.: CNAS L6048
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of
        testing. The Registration No. is CNAS L6048.
         A2LA - Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.8 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                        Page 6 of 18


                                                                               Report No: CCISE180601105

5.9 Test Instruments list
Radiated Emission:
                                                                            Inventory     Cal. Date     Cal. Due date
Item     Test Equipment          Manufacturer              Model No.
                                                                               No.       (mm-dd-yy)      (mm-dd-yy)
 1          3m SAC                 SAEMC                9(L)*6(W)* 6(H)    CCIS0001      07-22-2017     07-21-2020
 2     BiConiLog Antenna       SCHWARZBECK                VULB9163         CCIS0005      03-16-2018     03-15-2019
 3       Horn Antenna          SCHWARZBECK               BBHA9120D         CCIS0006      03-16-2018     03-15-2019
          Pre-amplifier
 4                                    HP                     8447D         CCIS0003      03-07-2018     03-06-2019
        (10kHz-1.3GHz)
          Pre-amplifier      Compliance Direction
 5                                                        PAP-1G18         CCIS0011      03-07-2018     03-06-2019
         (1GHz-18GHz)           Systems Inc.
       Spectrum analyzer
 6                            Rohde & Schwarz               FSP30          CCIS0023      03-07-2018     03-06-2019
           9k-30GHz
 7     EMI Test Receiver      Rohde & Schwarz               ESRP7          CCIS0167      03-07-2018     03-06-2019
 8     EMI Test Software            AUDIX                     E3              N/A           N/A            N/A
 9       Coaxial Cable                N/A                     N/A          CCIS0018      03-07-2018     03-06-2019
10       Coaxial Cable                N/A                     N/A          CCIS0020      03-07-2018     03-06-2019


Conducted Emission:
                                                                             Inventory     Cal.Date     Cal.Due date
Item     Test Equipment          Manufacturer              Model No.
                                                                                No.      (mm-dd-yy)     (mm-dd-yy)
 1      Shielding Room       ZhongShuo Electron      11.0(L)x4.0(W)x3.0(H) CCIS0061      07-22-2017     07-21-2020
 2     EMI Test Receiver      Rohde & Schwarz                ESCI           CCIS0002     03-07-2018     03-06-2019
 3           LISN                 CHASE                    MN2050D          CCIS0074     03-19-2018     03-18-2019
 4           LISN             Rohde & Schwarz              ESH3-Z5         8438621/010   07-21-2017     07-20-2018
 5      Coaxial Cable               CCIS                      N/A          CCIS0086      03-07-2018     03-06-2019
 6     EMI Test Software            AUDIX                     E3             N/A            N/A            N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 7 of 18


                                                                               Report No: CCISE180601105

6      Test results and Measurement Data
6.1 Conducted Emission
        Test Requirement:                FCC Part 15 B Section 15.107
        Test Method:                     ANSI C63.4:2014
        Test Frequency Range:            150kHz to 30MHz
        Class / Severity:                Class B                 Class B
        Receiver setup:                  RBW=9kHz, VBW=30kHz
        Limit:                                                                         Limit (dBµV)
                                           Frequency range (MHz)
                                                                           Quasi-peak               Average
                                                  0.15-0.5                   66 to 56*              56 to 46*
                                                    0.5-5                       56                     46
                                                   0.5-30                       60                     50
                                         * Decreases with the logarithm of the frequency.
        Test setup:




        Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network(L.I.S.N.). The provide a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                         2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refers to the block diagram of the test setup and
                                            photographs).
                                         3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
        Test environment:                Temp.:       23 C         Humid.:   56%         Press.:    101kPa
        Test Instruments:                Refer to section 5.9 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


                                                                            Report No: CCISE180601105

Measurement data:
Test Phase: Line




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 9 of 18


                                                                            Report No: CCISE180601105


Test Phase: Neutral




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 10 of 18


                                                                           Report No: CCISE180601105

6.2 Radiated Emission
       Test Requirement:                 FCC Part 15 B Section 15.109
       Test Method:                      ANSI C63.4:2014
       Test Frequency Range:             30MHz to 6000MHz
       Test site:                        Measurement Distance: 3m (Semi-Anechoic Chamber)
       Receiver setup:                    Frequency       Detector        RBW     VBW          Remark
                                         30MHz-1GHz      Quasi-peak      120kHz  300kHz    Quasi-peak Value
                                                           Peak           1MHz    3MHz       Peak Value
                                         Above 1GHz
                                                           RMS            1MHz    3MHz      Average Value
       Limit:                                 Frequency          Limit (dBuV/m @3m)          Remark
                                            30MHz-88MHz                   40.0          Quasi-peak Value
                                           88MHz-216MHz                   43.5          Quasi-peak Value
                                           216MHz-960MHz                  46.0          Quasi-peak Value
                                            960MHz-1GHz                   54.0          Quasi-peak Value
                                                                          54.0            Average Value
                                             Above 1GHz
                                                                          74.0             Peak Value
       Test setup:                       Below 1GHz




                                         Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                     Page 11 of 18


                                                                               Report No: CCISE180601105


       Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                           ground at a 3 meter semi-anechoic camber. The table was rotated 360
                                           degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and Specified
                                           Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of the
                                           EUT would be reported. Otherwise the emissions that did not have 10dB
                                           margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
       Test environment:                Temp.:       25 C         Humid.:     55%         Press.:    1 01kPa
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          All of the observed value above 6GHz ware the niose floor , which were no
                                        recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


                                                                                     Report No: CCISE180601105

Measurement Data:
Below 1GHz
Test Polarization: Horizontal




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 13 of 18


                                                                                     Report No: CCISE180601105


Test Polarization: Vertical




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 14 of 18


                                                                                     Report No: CCISE180601105


Above 1GHz
Test Polarization: Horizontal




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 15 of 18


                                                                                     Report No: CCISE180601105


Test Polarization: Vertical




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1806011
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 16 of 18



Document Created: 2018-07-24 17:21:32
Document Modified: 2018-07-24 17:21:32

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC