Test Report_PCE

FCC ID: 2ABOSSKYMUSIC

Test Report

Download: PDF
FCCID_4120403

                            Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE181109303

1. Cover Page
                                                FCC REPORT
                                                                  (GSM)

Applicant:                                 Sky Phone LLC
                                           1348 Washington Av.Suite 350, Miami Beach, Florida, United
Address of Applicant:
                                           States
Equipment Under Test (EUT)

     Product Name:                         Feature Phone

     Model No.:                            SKY F2C, SKY MUSIC

     Trade mark:                           SKY DEVICES

FCC ID:                                    2ABOSSKYMUSIC
                                           FCC CFR Title 47 Part 2
Applicable standards:                      FCC CFR Title 47 Part 22 Subpart H
                                           FCC CFR Title 47 Part 24 Subpart E
Date of sample receipt:                    04 Sep., 2018

Date of Test:                              04 Sep., to 11 Sep., 2018

Date of report issued:                     30 Nov., 2018

Test Result:                               PASS*

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




         Bruce Zhang
       Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE181109303


2. Version
     Version No.                         Date                                    Description
                                                                   This report was amended on FCC ID:
                                                                  2ABOSSKYMUSIC follow FCC Class II
                                                                           Permissive Change.
            00                     30 Nov., 2018                 The differences between them as below:
                                                                   Add model .: SKY F2C . SKY F2C is a
                                                                single SIM card, before SKY MUSIC was a
                                                                          dual SIM card. So re-test RE




  Tested by:                                                             Date:           30 Nov., 2018

                                       Test Engineer

  Reviewed by:                                                           Date:           30 Nov., 2018

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 2 of 18


                                                                                                                           Report No: CCISE181109303

3. Contents
                                                                                                                                                                               Page
1.     COVER PAGE .............................................................................................................................................................. 1
2.     VERSION ....................................................................................................................................................................... 2
3.     CONTENTS................................................................................................................................................................... 3
4.     TEST SUMMARY ......................................................................................................................................................... 4
5.     GENERAL INFORMATION ........................................................................................................................................ 5
     5.1       CLIENT INFORMATION ............................................................................................................................................ 5
     5.2       GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
     5.3       TEST MODES .......................................................................................................................................................... 6
     5.4       DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
     5.5       MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
     5.6       LABORATORY FACILITY.......................................................................................................................................... 6
     5.7       LABORATORY LOCATION ....................................................................................................................................... 6
     5.8       TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6.     TEST RESULTS ........................................................................................................................................................... 8
     6.1       CONDUCTED OUTPUT POWER, ERP AND EIRP .................................................................................................. 8
     6.2       OCCUPY BANDWIDTH ............................................................................................................................................ 9
     6.3       PEAK-TO-AVERAGE POWER RATIO .................................................................................................................... 10
     6.4       MODULATION CHARACTERISTIC .......................................................................................................................... 11
     6.5       OUT OF BAND EMISSION AT ANTENNA TERMINALS .............................................................................................. 11
     6.6       FIELD STRENGTH OF SPURIOUS RADIATION MEASUREMENT............................................................................... 12
     6.7       FREQUENCY STABILITY V.S. TEMPERATURE MEASUREMENT............................................................................. 15
     6.8       FREQUENCY STABILITY V.S. VOLTAGE MEASUREMENT ..................................................................................... 16
7      TEST SETUP PHOTO ............................................................................................................................................... 17
8      EUT CONSTRUCTIONAL DETAILS ...................................................................................................................... 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                  Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                            Page 3 of 18


                                                                                     Report No: CCISE181109303

4. Test Summary
                      Test Item                                    Section in CFR 47                   Result
                                                                                                        Pass
                                                                          Part 1.1307
                RF Exposure (SAR)                                                                  (Please refer to
                                                                          Part 2.1093
                                                                                                    SAR Report)
                                                                      Part 2.1046
                  RF Output Power                                   Part 22.913 (a)(2)                 Pass*
                                                                     Part 24.232 (c)
           Peak-to-Average Power Ratio                                   Part 24.232 (d)               Pass*
             Modulation Characteristics                                   Part 2.1047                  Pass*
                                                                          Part 2.1049
        99% & -26 dB Occupied Bandwidth                                  Part 22.917(b)                Pass*
                                                                         Part 24.238(b)
                                                                          Part 2.1051
     Spurious Emissions at Antenna Terminal                              Part 22.917 (a)               Pass*
                                                                         Part 24.238 (a)
                                                                          Part 2.1053
       Field Strength of Spurious Radiation                              Part 22.917 (a)                Pass
                                                                         Part 24.238 (a)
                                                                         Part 22.917 (a)
         Out of band emission, Band Edge                                                               Pass*
                                                                         Part 24.238 (a)
                                                                       Part 22.355
        Frequency stability vs. temperature                            Part 24.235                     Pass*
                                                                   Part 2.1055(a)(1)(b)
                                                                       Part 22.355
           Frequency stability vs. voltage                             Part 24.235                     Pass*
                                                                     Part 2.1055(d)(2)
 Pass: The EUT complies with the essential requirements in the standard.
  Pass*: Please refer to the report No.: CCISE180900401




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 4 of 18


                                                                                   Report No: CCISE181109303

5. General Information
5.1 Client Information
       Applicant:                         Sky Phone LLC
       Address:                           1348 Washington Av.Suite 350 ,Miami Beach, Florida, United States
       Manufacturer                       Hunan Huigao electronics technology co., ltd.
       Address:                           Yaodu RD north jianghua industrial park Jianghua Yaozu autonomous
                                          county, Yongzhou, Hunan province, China

5.2 General Description of E.U.T.
        Product Name:                     Feature Phone
        Model No.:                        SKY F2C, SKY MUSIC
        Operation Frequency range:        GSM 850: 824.20MHz-848.80MHz
                                          PCS1900: 1850.20MHz-1909.80MHz
        Modulation type:                  GSM/GPRS: GMSK
        Antenna type:                     Internal Antenna
        Antenna gain:                     GSM 850: -3.3 dBi
                                          PCS 1900: -1.2 dBi
       Power supply:                      Rechargeable Li-ion Battery DC3.7V-600mAh
        AC adapter:                       Model: SKY Music
                                          Input: AC100-240V, 50/60Hz, 0.2A
                                          Output: DC 5.0V, 500mA
                                          The model No.: SKY F2C, SKY MUSIC were identical inside, the
                                          electrical circuit design, layout, components used and internal wiring,
       Remark:                            Different model. The PCB function is the same, only difference is as
                                          below:
                                          SKY MUSIC is a double SIM card, SKY F2C is a single SIM card


Operation Frequency List:
                    GSM 850                                                           PCS1900
         Channel            Frequency (MHz)                              Channel                 Frequency (MHz)
           128                   824.20                                    512                       1850.20
           129                   824.40                                    513                       1850.40
           ….                      ….                                      ….                          ….
           189                   836.40                                    660                       1879.80
           190                   836.60                                    661                       1880.00
           191                   836.80                                    662                       1880.20
            …                      …                                        …                          …
           250                   848.60                                    809                       1909.60
           251                   848.80                                    810                       1909.80

Regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the
highest frequency of channel were selected to perform the test, and the selected channel see below:
                           GSM850                                                     PCS1900
             Channel                     Frequency(MHz)                    Channel                   Frequency(MHz)
  Lowest channel             128             824.20             Lowest channel            512            1850.20
  Middle channel             190             836.60             Middle channel            661            1880.00
  Highest channel            251             848.80             Highest channel           810            1909.80

Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 5 of 18


c c I s                                                                              Report No: CCISE181109303

5.3 Test modes
        Operating Environment:
        Temperature:                 Normal: 15°C ~35°C, Extreme: —30°C ~+50°C
        Humidity:                    20 % ~ 75 % RH
        Atmospheric Pressure:         1008 mbar
        Voltage:                     Nominal: 3.7V¥de, Extreme: Low 3.5 Vde, High 4.2 Vde
        Test mode:
        GSM mode               Keep the EUT communication with simulated station in GSM mode
        GPRS mode              Keep the EUT communication with simulated station in GPRS mode
        Remark: The EUT has been tested under continuous transmitting mode. Channel Low, Mid and High
        for each type band with rated data rate were chosen for full testing. The field strength of spurious
        radiation emission was measured as EUT stand—up position (H mode) and lie down position (E1, E2
        mode) for these modes with power adaptor, earphone and Data cable. Just the worst case position (H
        mode) shown in report.

5.4 Description of Support Units
     Test Equipment                  Manufacturer                        Model No.                  Serial No.
     Simulated Station                   Anritsu                         MT8820C                    6201026545

5.5 Measurement Uncertainty
                    Parameters                                                 Expanded Uncertainty
         Radiated Emission (OkHz ~ S3OMHz)                                        +2.76 dB (k=2)
       Radiated Emission (3OMHz ~ 1000MHz)                                        +4.28 dB (k=2)
         Radiated Emission (1GHz ~ 18GHz)                                         +5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                         +2.88 dB (k=2)
5.6 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
       ® FCC — Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
       ® 1C — Registration No.: 10106A—1
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
        Registration No.: 10106A—1.
       ® CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of
        testing. The Registration No. is CNAS L6048.
       ®     A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https/portal.a?la.org/scopepdf/4346—01.pdf

5.7 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
        Email: info@ccis—cb.com, Website: http:/www.ccis—cb.com


Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1811093
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 6 of 18


                                                                                     Report No: CCISE181109303

5.8 Test Instruments list
                                                                                            Cal. Date     Cal. Due date
    Test Equipment           Manufacturer            Model No.             Serial No.
                                                                                           (mm-dd-yy)      (mm-dd-yy)
       3m SAC                 SAEMC                  9m*6m*6m                966           07-22-2017      07-21-2020
  BiConiLog Antenna        SCHWARZBECK               VULB9163                497           03-16-2018      03-15-2019
  Biconical Antenna        SCHWARZBECK               VUBA9117                359           06-22-2017      06-21-2020
    Horn Antenna           SCHWARZBECK              BBHA9120D                916           03-16-2018      03-15-2019
    Horn Antenna           SCHWARZBECK              BBHA9120D                1805          06-22-2017      06-21-2020
                                                                                           11-21-2017      11-20-2018
     Horn Antenna          SCHWARZBECK              BBHA 9170            BBHA9170582
                                                                                           11-21-2018      11-20-2019
   EMI Test Software           AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier               HP                   8447D               2944A09358     03-07-2018        03-06-2019
     Pre-amplifier               CD                  PAP-1G18                11804       03-07-2018        03-06-2019
   Spectrum analyzer       Rohde & Schwarz            FSP30                 101454       03-07-2018        03-06-2019
                                                                                         11-21-2017        11-20-2018
   Spectrum analyzer       Rohde & Schwarz             FSP40                100363
                                                                                         11-21-2018        11-20-2019
   EMI Test Receiver       Rohde & Schwarz            ESRP7                 101070         03-07-2018     03-06-2019
                                                                                           11-10-2017     11-09- 2018
  Spectrum Analyzer             Agilent               N9020A              MY50510123
                                                                                           11-21-2018     11-20-2019
   Signal Generator        Rohde & Schwarz            SMX                 835454/016     03-07-2018        03-06-2019
   Signal Generator             R&S                  SMR20                1008100050     03-07-2018        03-06-2019
    RF Switch Unit           MWRFTEST                MW200                   N/A             N/A               N/A
    Test Software            MWRFTEST               MTS8200                            Version: 2.0.0.0
        Cable                  ZDECL              Z108-NJ-NJ-81             1608458      03-07-2018        03-06-2019
        Cable               MICRO-COAX              MFR64639                K10742-5     03-07-2018        03-06-2019
        Cable                 SUHNER              SUCOFLEX100              58193/4PE     03-07-2018        03-06-2019
                                                                                         10-31-2017        10-30-2018
   DC Power Supply             XinNuoEr            WYK-10020K            1409050110020
                                                                                         10-31-2018        10-30-2019
     Temperature                                                                         09-24-2017        09-23-2018
                                HengPu              HPGDS-500             20140828008
   Humidity Chamber                                                                      10-31-2018        10-30-2019
   Simulated Station       Rohde & Schwarz           CMW500                  140493      06-24-2018        06-23-2019




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 7 of 18


                                                                               Report No: CCISE181109303

6. Test results
6.1 Conducted Output Power, ERP and EIRP
        Test Requirement:                FCC part 22.913(a)(2), FCC part 24.232(c)
        Test Method:                     ANSI/TIA-603-D 2010
        Limit:                           GSM 850: 7W, PCS 1900: 2W
        Test setup:




        Test Procedure:                  The transmitter output was connected to a calibrated attenuator, the other
                                         end of which was connected to the simulated station. Transmitter output
                                         power was read off in dBm.
        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Please refer to the report No.: CCISE180900401




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 8 of 18


                                                                              Report No: CCISE181109303

6.2 Occupy Bandwidth
        Test Requirement:                FCC part 22.917(b), FCC part 24.238(b)
        Test Method:                     ANSI/TIA-603-D 2010
        Test setup:




        Test Procedure:                  1.   The EUT’s output RF connector was connected with a short cable to
                                              the spectrum analyzer
                                         2.   RBW was set to about 1% of emission BW, VBW= 3 times RBW.
                                         3.   -26dBc display line was placed on the screen (or 99% bandwidth),
                                              the occupied bandwidth is the delta frequency between the two
                                              points where the display line intersects the signal trace.
        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Please refer to the report No.: CCISE180900401




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 9 of 18


                                                                             Report No: CCISE181109303


6.3 Peak-to-Average Power Ratio
        Test Requirement:                FCC part 24.232(d)
        Test Method                      ANSI/TIA-603-D 2010
                                         The peak-to-average ratio (PAR) of the transmission may not exceed 13
        Limit:
                                         dB.
        Test setup:




        Test Procedure:                  1    The RF output of the transceiver was connected to a spectrum
                                              analyzer through appropriate attenuation.
                                         2    Set the CCDF option in spectrum analyzer, RBW ≥ OBW,
                                         3    Set the EUT working in highest power level, measured and recorded
                                              the 0.1% as PAPR level.
                                         4    Repeat step 1~3 at other frequency and modulations.
        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Please refer to the report No.: CCISE180900401




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 10 of 18


                                                                             Report No: CCISE181109303

6.4 Modulation Characteristic
    According to FCC § 2.1047(d), Part 22H & 24E there is no specific requirement for digital modulation,
    therefore modulation characteristic is not presented.

6.5 Out of band emission at antenna terminals
        Test Requirement:                FCC part 22.917(a), FCC part 24.238(a)
        Test Method:                     ANSI/TIA-603-D 2010
        Limit:                           -13dBm
        Test setup:




        Test Procedure:                  1    The RF output of the transceiver was connected to a spectrum
                                              analyzer through appropriate attenuation.
                                         2    The resolution bandwidth of the spectrum analyzer was set at 100
                                              kHz when below 1GHz, 1MHz when above 1 GHz; sufficient scans
                                              were taken to show the out of band Emissions if any up to 10th
                                              harmonic.
                                         3    For the out of band: Set the RBW=100 kHz, VBW=300 kHz when
                                              below 1 GHz, RBW =1 MHz, VBW=3 MHz when above 1 GHz,
                                              Start=30MHz, Stop= 10th harmonic.
                                         4    Band Edge Requirements: In the 1 MHz bands immediately outside
                                              and adjacent to the frequency block, a resolution bandwidth of at
                                              least 1 percent of the emission bandwidth of the fundamental
                                              emission of the transmitter may be employed to measure the out of
                                              band Emissions.
        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Please refer to the report No.: CCISE180900401




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 11 of 18


                                                                              Report No: CCISE181109303


6.6 Field strength of spurious radiation measurement
        Test Requirement:                FCC part 22.917(a), FCC part 24.238(a)
        Test Method:                     ANSI/TIA-603-D 2010
        Limit:                           -13dBm
        Test setup:                      Below 1GHz




                                         Above 1GHz




        Test Procedure:                  1.   The EUT was placed on an non-conductive turntable using a non-
                                              conductive support. The radiated emission at the fundamental
                                              frequency was measured at 3 m with a test antenna and EMI
                                              spectrum analyzer.
                                         2.   During the tests, the antenna height and the EUT azimuth were
                                              varied in order to identify the maximum level of emissions from the
                                              EUT. This maximization process was repeated with the EUT
                                              positioned in each of its three orthogonal orientations.
                                         3.   The frequency range up to tenth harmonic was investigated for each
                                              of three fundamental frequency (low, middle and high channels).
                                              Once spurious emission was identified, the power of the emission
                                              was determined using the substitution method.
                                         4.   The spurious emissions attenuation was calculated as the difference
                                              between radiated power at the fundamental frequency and the
                                              spurious emissions frequency.
                                               ERP / EIRP = S.G. output (dBm) + Antenna Gain(dB/dBi) –
                                               Cable Loss (dB)
        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details.
        Test results:                    PASS




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 12 of 18


                                                                                     Report No: CCISE181109303

Measurement Data (worst case):
                                                          GSM850
                                                      Lowest channel
                                            Spurious Emission
      Frequency (MHz)                                                               Limit (dBm)              Result
                                  Polarization             Level (dBm)
          1648.40                   Vertical                  -38.13
          2472.60                       V                     -39.27
                                                                                       -13.00                 Pass
          3296.80                       V                     -37.89
          4121.00                       V                     -36.65
          1648.40                  Horizontal                 -41.72
          2472.60                      H                      -39.32
                                                                                       -13.00                 Pass
          3296.80                      H                      -39.27
          4121.00                      H                      -32.66
                                                      Middle channel
                                            Spurious Emission
      Frequency (MHz)                                                               Limit (dBm)              Result
                                  Polarization             Level (dBm)
          1673.20                   Vertical                  -40.12
          2509.80                       V                     -44.92
                                                                                       -13.00                 Pass
          3346.40                       V                     -37.27
          4183.00                       V                     -40.11
          1673.20                  Horizontal                 -39.64
          2509.80                      H                      -42.23
                                                                                       -13.00                 Pass
          3346.40                      H                      -36.64
          4183.00                      H                      -41.87
                                                      Highest channel
                                            Spurious Emission
      Frequency (MHz)                                                               Limit (dBm)              Result
                                  Polarization             Level (dBm)
          1697.60                   Vertical                  -40.67
          2546.40                       V                     -45.72
                                                                                       -13.00                 Pass
          3395.20                       V                     -38.33
          4244.00                       V                     -30.79
          1697.60                  Horizontal                 -41.41
          2546.40                      H                      -42.84
                                                                                       -13.00                 Pass
          3395.20                      H                      -36.26
          4244.00                      H                      -31.34
 Remark:
 1.     The emission levels of below 1 GHz are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 13 of 18


                                                                                     Report No: CCISE181109303


                                                          PCS1900
                                                      Lowest channel
                                            Spurious Emission
      Frequency (MHz)                                                               Limit (dBm)              Result
                                  Polarization             Level (dBm)
          3700.40                   Vertical                  -33.84
                                                                                       -13.00                 Pass
          5550.60                       V                     -36.43
          3700.40                  Horizontal                 -35.53
                                                                                       -13.00                 Pass
          5550.60                      H                      -33.42
                                                      Middle channel
                                            Spurious Emission
      Frequency (MHz)                                                               Limit (dBm)              Result
                                  Polarization             Level (dBm)
          3760.00                   Vertical                  -35.83
                                                                                       -13.00                 Pass
          5640.00                       V                     -33.57
          3760.00                  Horizontal                 -35.86
                                                                                       -13.00                 Pass
          5640.00                      H                      -33.93
                                                      Highest channel
                                            Spurious Emission
      Frequency (MHz)                                                               Limit (dBm)              Result
                                  Polarization             Level (dBm)
          3819.60                   Vertical                  -36.69
                                                                                       -13.00                 Pass
          5729.40                       V                     -33.87
          3819.60                  Horizontal                 -32.86
                                                                                       -13.00                 Pass
          5729.40                      H                      -33.13
 Remark:
 1.     The emission levels of below 1 GHz are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 14 of 18


c c I s                                                                             Report No: CCISE181109303



6.7 Frequency stability V.S. Temperature measurement
        Test Requirement:                FCC Part 22.355, FCC Part 24.235, FCC Part 2.1055(a)(1)(b)
        Test Method:                     ANSVTIA—6—3—D 2010
        Limit:                           +2.5 ppm



        CCC                              D—|_q
                                               SS




                                               SA




                                                                                           Temperature & Humidity Chamber




                                                                            Power Source

        Test procedure:                  1.    The equipment under test was connected to an external DC power
                                               supply and input rated voltage.
                                         2.    RF output was connected to a frequency counter or spectrum
                                               analyzer via feed through attenuators.
                                         3.    The EUT was placed inside the temperature chamber.
                                         4.     Set the spectrum analyzer RBW low enough to obtain the desired
                                               frequency resolution and measure EUT 25°C operating frequency as
                                               reference frequency.
                                         5..   Turn EUT off and set the chamber temperature to —30°C. After the
                                               temperature stabilized for approximately 30 minutes recorded the
                                               frequency.
                                         6.    Repeat step measure with 10°C increased per stage until the highest
                                               temperature of +50°C reached
        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Please refer to the report No.: CCISE180900401




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1811093
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 15 of 18


c c I s                                                                               Report No: CCISE181109303

6.8 Frequency stability V.S. Voltage measurement
        Test Requirement:                FCC Part 22.355, FCC Part 24.235, FCC Part 2.1055(d)(2)
        Test Method:                     ANSVTIA—608—D 2010
        Limit:                           +2.5ppm
        Test setup:




                                         D_I_q                              pivider




                                                                                            Temperature & Humidity Chamber




                                                                            Power Source


        Test procedure:                  1.   Set chamber temperature to 25°C. Use a variable DC power source
                                              to power the EUT and set the voltage to rated voltage.
                                         2.    Set the spectrum analyzer RBW low enough to obtain the desired
                                              frequency resolution and recorded the frequency.
                                         3.    Reduce the input voltage to specify extreme voltage variation (+/—
                                              15%) and endpoint, record the maximum frequency change.
        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Please refer to the report No.: CCISE180900401




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1811093
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                      Page 16 of 18


                                                                         Report No: CCISE181109303


7 Test Setup Photo
                                         Radiated Spurious Emission




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 17 of 18


                                                                           Report No: CCISE181109303

8 EUT Constructional Details
     Reference to the test report No. CCISE181109301



                                               ------End of report------




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1811093
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                     Page 18 of 18



Document Created: 2018-12-21 09:13:06
Document Modified: 2018-12-21 09:13:06

© 2025 FCC.report