Test report

FCC ID: 2ABOSSKYELITET55

Test Report

Download: PDF
FCCID_4164484

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE181210406

1        Cover Page

                                      FCC REPORT
Applicant:                                 SKY PHONE LLC

Address of Applicant:                      1348 Washington Av. Suite 350, Miami Beach, FL 33139

Equipment Under Test (EUT)

    Product Name:                          4G Smart Phone

    Model No.:                             Elite T55

    Trade mark:                            SKY DEVICES

FCC ID:                                    2ABOSSKYELITET55

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    20 Dec., 2018

Date of Test:                              20 Dec., 2018 to 21 Jan., 2019

Date of report issued:                     21 Jan., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE181210406

2      Version
      Version No.                        Date                                    Description
            00                     21 Jan., 2019                                   Original




    Tested by:                                                           Date:          21 Jan., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          21 Jan., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1812104
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 2 of 18


                                                                                                                            Report No: CCISE181210406

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1812104
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE181210406

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1812104
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                               Report No: CCISE181210406

5      General Information
5.1 Client Information
       Applicant:                              SKY PHONE LLC
       Address of Applicant:                   1348 Washington Av. Suite 350, Miami Beach, FL 33139
       Manufacturer:                           SKY PHONE LLC
       Address:                                1348 Washington Av. Suite 350, Miami Beach, FL 33139

5.2 General Description of E.U.T.
       Product Name:                           4G Smart Phone
       Model No.:                              Elite T55
       Power supply:                           Rechargeable Li-ion Battery DC3.8V, 2500mAh
                                               Model: Elite T55
       AC adapter :                            Input: AC100-240V, 50/60Hz, 0.15A
                                               Output: DC 5.0V, 500mA
       Test Sample Condition:                  The test samples were provided in good working order with no visible
                                               defects.

5.3 Test Mode
         Operating mode                Detail description
             PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode            Keep the EUT in Charging+Recording mode
     Charging+Playing mode             Keep the EUT in Charging+Playing mode
             FM mode                   Keep the EUT in FM receiver mode
            GPS mode                 Keep the EUT in GPS receiver mode
The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
vertical polarities were performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying
antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown
in Test Results of the following pages.

5.4 Measurement Uncertainty
                   Parameters                                              Expanded Uncertainty
       Conducted Emission (9kHz ~ 30MHz)                                      ±2.22 dB (k=2)
        Radiated Emission (9kHz ~ 30MHz)                                      ±2.76 dB (k=2)
      Radiated Emission (30MHz ~ 1000MHz)                                     ±4.28 dB (k=2)
       Radiated Emission (1GHz ~ 18GHz)                                       ±5.72 dB (k=2)
       Radiated Emission (18GHz ~ 40GHz)                                      ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1812104
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                           Page 5 of 18


CCIS                                                                            Report No: CCISE181210406

5.5 Description of Support Units
      Manufacturer                 Description                 Model          Serial Number           FCC ID/DoC

            DELL                        PC                 OPTIPLEX745               N/A                  DaC
            DELL                    MONITOR                  E178FPC                 N/A                  DaC
            DELL                   KEYBOARD                   SK—8115                N/A                  DaC
            DELL                     MOUSE                   MOC§UO                  N/A                  DoC
         LENOVO                       Laptop                   SL510              2847A65                 DoC

5.6 Related Submittal(s) / Grant (s)
        This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
         Cable Type                     Description                Length            From                  To
    Detached USB Cable                   Shielding                   1.0m             EUT              PC/Adapter
  Detached headset cable                Unshielded                   1.2m             EUT               Headset

5.8 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ®   FCC — Registration No.: 727551
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
        (Federal Communications Commission). The Registration No. is 727551.
        ®    IC — Registration No.: 10106A—1
        The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
        with Registration No.: 10106A—1.
        ® CNAS — Registration No.: CNAS L6048
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of
        testing. The Registration No. is CNAS L6048.
        ®    A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.ora/scopepdf/4348—0 1.pdf

5.9 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
        Email: info@ccis—cb.com, Website: http//www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1812104
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                              Page 6 of 18


                                                                                  Report No: CCISE181210406

5.10 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m              966          07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-16-2018         03-15-2019
   BiConiLog Antenna         SCHWARZBECK               VULB9163              497          03-16-2018         03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              916          03-16-2018         03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358        03-07-2018        03-06-2019
     Pre-amplifier                 CD                  PAP-1G18             11804          03-07-2018        03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454          03-07-2018        03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018         11-20-2019
    EMI Test Receiver        Rohde & Schwarz           ESRP7                101070        03-07-2018         03-06-2019
         Cable                   ZDECL              Z108-NJ-NJ-81          1608458        03-07-2018         03-06-2019
         Cable                MICRO-COAX              MFR64639             K10742-5       03-07-2018         03-06-2019
         Cable                  SUHNER              SUCOFLEX100           58193/4PE       03-07-2018         03-06-2019


 Conducted Emission:
                                                                                          Cal. Date         Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz             ESCI               101189        03-07-2018          03-06-2019
     Pulse Limiter          SCHWARZBECK              OSRAM 2306             9731         03-07-2018          03-06-2019
         LISN                   CHASE                 MN2050D               1447         03-19-2018          03-18-2019
         LISN               Rohde & Schwarz           ESH3-Z5            8438621/010     07-21-2018          07-20-2019
        Cable                     HP                   10503A                N/A         03-07-2018          03-06-2019
   EMI Test Software            AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1812104
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                               Report No: CCISE181210406

6      Test results and Measurement Data
6.1 Conducted Emission
        Test Requirement:                FCC Part 15 B Section 15.107
        Test Method:                     ANSI C63.4:2014
        Test Frequency Range:            150kHz to 30MHz
        Class / Severity:                Class B                 Class B
        Receiver setup:                  RBW=9kHz, VBW=30kHz
        Limit:                                                                         Limit (dBµV)
                                           Frequency range (MHz)
                                                                           Quasi-peak               Average
                                                  0.15-0.5                   66 to 56*              56 to 46*
                                                    0.5-5                       56                     46
                                                   0.5-30                       60                     50
                                         * Decreases with the logarithm of the frequency.
        Test setup:




        Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network(L.I.S.N.). The provide a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                         2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refers to the block diagram of the test setup and
                                            photographs).
                                         3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
        Test Instruments:                Refer to section 5.9 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1812104
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


c c I s                                                                                     Report No: CCISE181210406

Measurement data:
Product name:                 4G Smart Phone                             Product model:       Elite T55
Test by:                      Mike                                       Test mode:           PC mode
Test frequency:               150 kHz ~ 30 MHz                           Phase:               Line

Test voltage:                 AC 120 V/60 Hz                             Environment:         Temp: 22.5°C            Huni: 55%

         so Level (dBuV)


         70

         eo\\                                                                                               ree parRT1s 8 op
         &6                                                                                                 FCC P fi B, AV
                                                                                                                  |            [
      40                                                                                                              ‘


         30

         20

         10


              15 12                  5                 1             2                  5              10                 20       30
  FraceNE                                                      Frequency (MHz)


                             Read   LISN      Cable                Limit    Over
                  Freq      Level Factor        Loss       Level    Line   Limit Remark

                      MHz    dBu¥        dB      dB         dBu¥    dBu¥      dB

     1           0.651      35.91    0.13     10.77        46.81   §6.00 —9.19 QP
     2           0.651      28.95    0.13     10.77        39.85   46.00 —6.15 Average
     3           0.779      30.48    0.13     10.80        41.41   46.00 —4.59 Average
     4           1.037      34.27    0.13     10.87        45.27   §6.00 —10.73 QP
     5           1.037      30.56    0.13     10.87        41.56   46.00 —4.44 Average
     6           1.296      29.11    0.13     10.90        40.14   46.00 —5.86 Average
     T           1.560      35.82    0.14     10.93        46.89   §6.00 —9.11 QP
     8           1.949      35.86    0.14     10.96        46.96   56.00 —9.04 QP
     9          17.109      40.09    0.30     10.91        §1.30   60.00 —8.70 9P
    10          17.108      36.12    0.30     10.91        47.33   50.00 —2.67 Average
    11          22.775      28.175   0.31     10.90        39.96   §0.00 —10.04 Average
    12          22.896      36.81    0.31     10.89        48.01   60.00 —11.99 QP




Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1812104
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                               Page 9 of 18


c c I s                                                                                  Report No: CCISE181210406


Product name:             4G Smart Phone                             Product model:          Elite T55
Test by:                  Mike                                       Test mode:              PC mode

Test frequency:           150 kHz ~ 30 MHz                           Phase:                  Neutral

Test voltage:             AC 120 V/60 Hz                             Environment:            Temp: 22.5°C           Huni: 55%

    so Level (dBuV)


    70
    60\
                                                                                                         FCC PART15 B OP


    50
                                                                                                         FCC PART1§]
                                                                                                               .‘ll  AV

    a                                                         ;                           audns                — —(1
                                                                                                                A


    30

    20

    10


         16 :2                   :5              1             2                     5             10                  20     30
Trane42                                                 Frequency (MHz)

                         Read         LISN    Cable           Linmit       Over
                 Freq   Level Factor           Loss   Level       Line    Linit Remark

                 MHz     dBu¥           dB       dB    dBu¥       dBu¥        dB

    1        0.654      36.42         0.97    10.77   48.16   56.00       —7.84 QP
    2        1.037      36.31         0.97    10.87   47.15   56.00       —8.85 QP
    3        1.037      29.72          0.67   10.87   41.26   46.00       —4.74 Average
    4         1.560     33.71         0.98    10.95   45.62   56.00 —10.38 QP
    5        1.949      26.41         0.67    10.96   38.04   46.00       —7.96    Average
    6        2.594      32.83         0.99    10.93   44.75   56.00      —11.25    QP
    T        6.488      24.98         0.70    10.81   36.49   50.00      —13.51    Average
    8        8.592      25.86         0.69    10.88   37.43   50.00      —12.57    Average
    9       17.291      40.31         0.80    10.91   52.02   60.00       —7.98    9P
   10       17.383      31.52         0.69    10.92   43.13   50.00       —6.87    Average
   11       22.298      37.46         0.68    10.90   49.04   60.00      —10.96    qP
   12       22.208      26.14         0.69    10.90   37.73   50.00      —12.27    Average



Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1812104
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                            Page 10 of 18


                                                                           Report No: CCISE181210406

6.2 Radiated Emission
       Test Requirement:                 FCC Part 15 B Section 15.109
       Test Method:                      ANSI C63.4:2014
       Test Frequency Range:             30MHz to 6000MHz
       Test site:                        Measurement Distance: 3m (Semi-Anechoic Chamber)
       Receiver setup:                    Frequency       Detector        RBW     VBW          Remark
                                         30MHz-1GHz      Quasi-peak      120kHz  300kHz    Quasi-peak Value
                                                           Peak           1MHz    3MHz       Peak Value
                                         Above 1GHz
                                                           RMS            1MHz    3MHz      Average Value
       Limit:                                 Frequency          Limit (dBuV/m @3m)          Remark
                                            30MHz-88MHz                   40.0          Quasi-peak Value
                                           88MHz-216MHz                   43.5          Quasi-peak Value
                                           216MHz-960MHz                  46.0          Quasi-peak Value
                                            960MHz-1GHz                   54.0          Quasi-peak Value
                                                                          54.0            Average Value
                                             Above 1GHz
                                                                          74.0             Peak Value
       Test setup:                       Below 1GHz




                                         Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1812104
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                     Page 11 of 18


                                                                               Report No: CCISE181210406


       Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                           ground at a 3 meter semi-anechoic camber. The table was rotated 360
                                           degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and Specified
                                           Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of the
                                           EUT would be reported. Otherwise the emissions that did not have 10dB
                                           margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          All of the observed value above 6GHz ware the niose floor , which were no
                                        recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1812104
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


CCIS                                                                                   Report No: CCISE181210406

Measurement Data:
Below 1GHz:

Product Name:                4G Smart Phone                          Product Model:             Elite T55
Test By:                     Mike                                    Test mode:                 PC mode

Test Frequency:              30 MHz ~ 1 GHz                          Polarization:             Vertical

Test Voltage:                AC 120/60Hz                             Environment:              Temp: 24°C      Huni: 57%


      so Level (dBuVim)


      70

      60
                                                                                                  FCC PART1S CLAS$ B
      50

      40


      30


      20

      10


       030              50                    100                   200                           500              1000
                                                         Frequency (MHz)

                             Read&ntenna      Cable Preamp                 Linit      Over
                 Freq     Level Factor          Loss Factor      Level      Line     Limit Remark

           _      WHz        dbu¥y    dB/n       dB        db dBbu¥/m dBu¥/m             dB
      1       62.871      48.37      11.40     1.38    29.76     31.39     40.00 —8.61 QP
      2      122.834      41.73       9. T6    2.20    29.37     24.32     43.50 —19.18 QP
      5      165.487      40.33       9. 27    2.62    29.09     23.13     43.50 —20.37 QP
      4      263.819      41.45      13.39     2.85    28.51     29.18     46.00 —16.82 QP
      5      369.4056     38.80      14.96     3.09    28.65     28.20     46.00 —17.80 QP
      6      480.528      44.97      16.97     3.46    28.92     36.48     46.00 —9.52 QP



Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1812104
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                    Page 13 of 18


CCIS                                                                                   Report No: CCISE181210406


Product Name:                    4G Smart Phone                      Product Model:             Elite T55
Test By:                         Mike                                Test mode:                 PC mode

Test Frequency:                  30 MHz ~ 1 GHz                      Polarization:              Horizontal

Test Voltage:                    AC 120/60Hz                         Environment:              Temp: 24°C        Huni: 57%


        8Olevel (dBu\V/m)


           70

        60
                                                                                                    FCC PART15 CLAS$ 8
        50


        40


        30

        20


        10


                30              50                100                200                            500              1000
                                                           Frequency (MHz)

                                 Read&ntenna      Cable Preamp               Limit    Over
                        Freq    Level Factor       Loss Factor    Level       Line    Limit Remark

                         MHz     dBu¥     dB/n       dB      dB dBu¥/m dBu¥/m            dB

       1              62.213    47.70   11.62      1.38   29.77   30.93      40.00    —9.07   QP
       2             153. 739   49.83    8.79      2.54   29.19   31.97      43.50   —11.53   QP
       3             267.546    50.02   13.41      2.86   28.51   37.78      46.00    —8.22   QP
       4             480.528    41.98   16.97      3.46   28.92   33.49      46.00   —12.51   QP
       5             625.078    38.43   19.51      3.90   28.86   32.98      46.00   —13.02   QP
       6             836.244    38.53   21.22      4.23   28.06   35.92      46.00   —10.08   QP


Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1812104
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                      Page 14 of 18


c c I s                                                                                Report No: CCISE181210406

Above 1GHz:
Product Name:               4G Smart Phone                            Product Model:           Elite T55
Test By:                    Mike                                      Test mode:               PC mode

Test Frequency:             1 GHz ~ 6 GHz                             Polarization:            Vertical

Test Voltage:               AC 120/60Hz                               Environment:             Temp: 24°C          Huni: 57%

       SOLeveI (dBuVim)
                                                                                                       FCC PART 15 (PK)
       70


       60
                                                                                                       FCC PART 15 (AV$
       50                                                                                          3       3

       40

       30


       20

       10


            1000    1200           1500              2000                                                   5000      6000
                                                            Frequency (MHz)


                            Read&ntenna     Cable Preamp                 Limit     Over
                   Freq    Level Factor      Loss Factor         Level    Line    Linit Remark

                    MHz     dBu¥     dB/n       dB          dB dBu¥/m dBu¥/m          dB
      1      4228.805      47.80    30.63     6.45     41.83     47.61   74.00 —26.39 Peak
      2       4228.805     37.20    30.63     6.45     41.83     37.01   54.00 —16.99 Average
      3       4808.328     46.90    31.60     6.80     41.81     48.37   74.00 —25.63 Peak
      4       4808.328     40.26    31.60     6.80     41.81     41.73   54.00 —12.27 Average
      5       5898.3%M4    48.18    33.12     7.91     42.03     §2.72   74.00 —21.28 Peak
      6      5898. 334     37.41    33.12     7.91     42.03     41.95   54.00 —12.05 Average



Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1812104
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 15 of 18


c c I s                                                                                   Report No: CCISE181210406


Product Name:               4G Smart Phone                            Product Model:            Elite T55
Test By:                    Mike                                      Test mode:                PC mode

Test Frequency:             1 GHz ~ 6 GHz                             Polarization:             Horizontal

Test Voltage:               AC 120/60Hz                               Environment:             Temp: 24°C              Huni: 57%


      8oLevel (dBu\Vim)
                                                                                                    FCC PART 15 (PK)
      70

     60
                                                                                                    FCC PART 15 (AV)
                                                                                                            3
      50                                                                              4                                 ]

     40


      30

      20


      10


           G1000   1200           1500           2000                                                           5000        6000
                                                        Frequency (MHz)

                           Read&ntenna      Cable Preanp               Linit     Over
                   Freq   Level Factor        Loss Factor    Level      Line    Limit Remark

                   NHz     dBu¥      dB/n      dB       dB dBu¥/m dBu¥/m            dB
      1       3447.326    47.91     28.87    5.69   41.40    45.41     74.00   —28.59     Peak
      20      3447.326    38.19     28.87    5.69   41.40    36.69     54.00   —18.31     Average
      3        4808.328   47.13     31.60    6.80   41.81    48.60     74.00   —25.40     Peak
      4        4808.328   39.64     31.60    6.80   41.81    41.11     54.00   —12.89     Average
      5       §662.163    48.47     32.70    7.50   41.87     §2.20    74.00 —21.80 Peak
      6        S662.163   38.66     32.70    7.50   41.87    42.39     54.00 —11.61 Average



Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1812104
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                            Page 16 of 18



Document Created: 2019-01-28 14:02:01
Document Modified: 2019-01-28 14:02:01

© 2025 FCC.report