Test report

FCC ID: 2ABOSSKYELITEGO

Test Report

Download: PDF
FCCID_4145659

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE181210206

1        Cover Page

                                      FCC REPORT
Applicant:                                 SKY PHONE LLC

Address of Applicant:                      1348 Washington Av. Suite 350, Miami Beach, FL 33139

Equipment Under Test (EUT)

    Product Name:                          4G Smart Phone

    Model No.:                             Elite Go

    Trade mark:                            SKY DEVICES

FCC ID:                                    2ABOSSKYELITEGO

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    20 Dec., 2018

Date of Test:                              20 Dec., 2018 to 11 Jan., 2019

Date of report issued:                     14 Jan., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE181210206

2      Version
      Version No.                        Date                                    Description
            00                     14 Jan., 2019                                   Original




    Tested by:                                                           Date:          14 Jan., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          14 Jan., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 2 of 18


                                                                                                                            Report No: CCISE181210206

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE181210206

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                               Report No: CCISE181210206

5      General Information
5.1 Client Information
       Applicant:                              SKY PHONE LLC
       Address:                                1348 Washington Av. Suite 350, Miami Beach, FL 33139
       Manufacturer:                           SKY PHONE LLC
       Address:                                1348 Washington Av. Suite 350, Miami Beach, FL 33139

5.2 General Description of E.U.T.
       Product Name:                           4G Smart Phone
       Model No.:                              Elite Go
       Power supply:                           Rechargeable Li-ion Battery DC3.8V-2350mAh
                                               Model: Elite Go
       AC adapter :                            Input: AC100-240V, 50/60Hz, 0.2A
                                               Output: DC 5.0V, 1.0A
       Test Sample Condition:                  The test samples were provided in good working order with no visible
                                               defects.

5.3 Test Mode
         Operating mode                Detail description
             PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode            Keep the EUT in Charging+Recording mode
     Charging+Playing mode             Keep the EUT in Charging+Playing mode
             FM mode                   Keep the EUT in FM receiver mode
            GPS mode                 Keep the EUT in GPS receiver mode
The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
vertical polarities were performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying
antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown
in Test Results of the following pages.

5.4 Measurement Uncertainty
                   Parameters                                              Expanded Uncertainty
       Conducted Emission (9kHz ~ 30MHz)                                      ±2.22 dB (k=2)
        Radiated Emission (9kHz ~ 30MHz)                                      ±2.76 dB (k=2)
      Radiated Emission (30MHz ~ 1000MHz)                                     ±4.28 dB (k=2)
       Radiated Emission (1GHz ~ 18GHz)                                       ±5.72 dB (k=2)
       Radiated Emission (18GHz ~ 40GHz)                                      ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                           Page 5 of 18


                                                                           Report No: CCISE181210206

5.5 Description of Support Units
      Manufacturer                Description                  Model     Serial Number         FCC ID/DoC
           DELL                         PC                OPTIPLEX745          N/A                  DoC
           DELL                    MONITOR                   E178FPC           N/A                  DoC
           DELL                   KEYBOARD                    SK-8115          N/A                  DoC
           DELL                      MOUSE                   MOC5UO            N/A                  DoC
         LENOVO                       Laptop                   SL510        2847A65                 DoC

5.6 Related Submittal(s) / Grant (s)
        This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
       N/A

5.8 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
         FCC - Registration No.: 727551
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
        (Federal Communications Commission). The Registration No. is 727551.
         IC - Registration No.: 10106A-1
        The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
        with Registration No.: 10106A-1.
         CNAS - Registration No.: CNAS L6048
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of
        testing. The Registration No. is CNAS L6048.
         A2LA - Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.9 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                        Page 6 of 18


                                                                                  Report No: CCISE181210206

5.10 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date      Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                          (mm-dd-yy)       (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m              966          07-22-2017       07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-16-2018       03-15-2019
   BiConiLog Antenna         SCHWARZBECK               VULB9163              497          03-16-2018       03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              916          03-16-2018       03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017       06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018       11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358        03-07-2018     03-06-2019
     Pre-amplifier                 CD                  PAP-1G18             11804          03-07-2018     03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454          03-07-2018     03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018       11-20-2019
    EMI Test Receiver        Rohde & Schwarz           ESRP7                101070        03-07-2018       03-06-2019
         Cable                   ZDECL              Z108-NJ-NJ-81          1608458        03-07-2018       03-06-2019
         Cable                MICRO-COAX              MFR64639             K10742-5       03-07-2018       03-06-2019
         Cable                  SUHNER              SUCOFLEX100           58193/4PE       03-07-2018       03-06-2019


 Conducted Emission:
                                                                                          Cal. Date       Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                        (mm-dd-yy)         (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz             ESCI               101189        03-07-2018        03-06-2019
     Pulse Limiter          SCHWARZBECK              OSRAM 2306             9731         03-07-2018        03-06-2019
         LISN                   CHASE                 MN2050D               1447         03-19-2018        03-18-2019
         LISN               Rohde & Schwarz           ESH3-Z5            8438621/010     07-21-2018        07-20-2019
        Cable                     HP                   10503A                N/A         03-07-2018        03-06-2019
   EMI Test Software            AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                Page 7 of 18


                                                                               Report No: CCISE181210206

6      Test results and Measurement Data
6.1 Conducted Emission
        Test Requirement:                FCC Part 15 B Section 15.107
        Test Method:                     ANSI C63.4:2014
        Test Frequency Range:            150kHz to 30MHz
        Class / Severity:                Class B                 Class B
        Receiver setup:                  RBW=9kHz, VBW=30kHz
        Limit:                                                                         Limit (dBµV)
                                           Frequency range (MHz)
                                                                           Quasi-peak               Average
                                                  0.15-0.5                   66 to 56*              56 to 46*
                                                    0.5-5                       56                     46
                                                   0.5-30                       60                     50
                                         * Decreases with the logarithm of the frequency.
        Test setup:




        Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network(L.I.S.N.). The provide a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                         2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refers to the block diagram of the test setup and
                                            photographs).
                                         3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
        Test environment:                Temp.:       22.5 C       Humid.:   55%         Press.:    101kPa
        Test Instruments:                Refer to section 5.9 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


c c I s                                                                              Report No: CCISE181210206

Measurement data:
Product name:              4G Smart Phone                          Product model:        Elite Go
Test by:                   Yaro                                    Test mode:            PC mode

Test frequency:             150 kHz ~ 30 MHz                       Phase:                Line

Test voltage:              AC 120 V/60 Hz                          Environment:          Temp: 22.5°C        Huni: 55%

         80 Level (dBuV)


         70

         60                                                                                           FCC PART15 B OP

         501\\\                                                                     FCC PARMSE AV
                                                                                    _

         40
         30| |

         20
         10

          0
                                                         Frequency (MHz)
  Trace: 5
                                  Read        LISN      Cable                     Limit          Over
                    Freq       Level Factor                Loss      Level          Line        Linit Remark

                      MHz         dBu¥           dB           dB         dBu¥       dBu¥             dB

    1              0. 154      38.29          0.18       10.78       49.25        65.78     —16.53        QP
    2              0. 154      24.60         0.18        10.78       35.56        65.78     —30.22        Average
    3              0. 186      35.19         0.16        10.76       46.11        64.20     —18.09        qP
    4              0. 186      20.38         0.16        10.76       31.30        64.20     —32.90        Average
    5              0.489       29.97         0.12        10.76       40.85        56.19     —15.34        QP
    6              0.489       20.53         0.12        10.76       31.41        56.19     —24.78        &verage
    T              0.535       19.52         0.12        10.76       30.40        56.00     —25.60        Average
    8              1.021       25.3M          O.13       10.8f       36.34        56.00     —19.66        qP
    9              1.628       24.53         0.14        10.93       35.60        56.00     —20.40        QP
   10              2.T0O7T     25.88         0.16        10.93       36.97        56.00     —19.03        QP
   11              2.TT9       17.51         0.16        10.93       28.60        56.00     —27.40        Average
   12              3.107       16.37         O0.17       10.92       27.46        56.00     —28.54        Average

Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1812102
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                   Page 9 of 18


c c I s                                                                              Report No: CCISE181210206


Product name:              4G Smart Phone                          Product model:         Elite Go
Test by:                   Yaro                                   Test mode:              PC mode

Test frequency:            150 kHz ~ 30 MHz                        Phase:                 Neutral

Test voltage:              AC 120 V/60 Hz                          Environment:           Temp: 22.5°C         Huni: 55%

      80 Level (dBuV)



      70

      Goh‘\‘“-k_                                                                                          ree partis 8 op
           h.
      sop     §   \                                                                                       FCC PART15B AV


      40

      30]1)

      20

      10



                                                         Frequency (MHz)
 Trace: /
                               Read   LISN             Cable                     Linmit       Over
                   Freq       Level Factor              Loss        Level         Line       Limit Remark

                     MHz          dBu¥          dB           dB       dBu¥         dBu¥              dB

    1             0. 150      21.46         0.99        10.78       33.23        66.00     —32.77          Average
    2             0. 154      35.67         0.98        10.78       41.43        65.78     —18.35          QP
    3             0. 158      20.69         0.98        10.77       32.44        65.56     —33.12          Average
    4             0.182       32.42         0.94        10.77       44.13        64.42     —20.29          QP
    5             0.182       18.14         0.94        10.77       29.85        64.42     —34.57          Average
    6             0.489       32.35         0.97        10.76       44.08        56.190    —12.11          QP
    T             0.489       21.08         0.97        10.76       32.81        56.19     —23.38          Average
    8             0.513       29.56         0.97        10.76       41.29        56.00     —14.71          QP
    9             0.518       21.03         0.97        10.76       32.76        56.00     —23.24          Average
   10             0.573       28.42         0.97        10.76       40.15        56.00     —15.85          qP
   11             2.636       24.89         0.99        10.93       36.81        56.00     —19.19          QP
   12             2.839       15.54         0.99        10.93       27.46        56.00     —28.54          Average

Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1812102
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                     Page 10 of 18


                                                                           Report No: CCISE181210206

6.2 Radiated Emission
       Test Requirement:                 FCC Part 15 B Section 15.109
       Test Method:                      ANSI C63.4:2014
       Test Frequency Range:             30MHz to 6000MHz
       Test site:                        Measurement Distance: 3m (Semi-Anechoic Chamber)
       Receiver setup:                    Frequency       Detector        RBW     VBW          Remark
                                         30MHz-1GHz      Quasi-peak      120kHz  300kHz    Quasi-peak Value
                                                           Peak           1MHz    3MHz       Peak Value
                                         Above 1GHz
                                                           RMS            1MHz    3MHz      Average Value
       Limit:                                 Frequency          Limit (dBuV/m @3m)          Remark
                                            30MHz-88MHz                   40.0          Quasi-peak Value
                                           88MHz-216MHz                   43.5          Quasi-peak Value
                                           216MHz-960MHz                  46.0          Quasi-peak Value
                                            960MHz-1GHz                   54.0          Quasi-peak Value
                                                                          54.0            Average Value
                                             Above 1GHz
                                                                          74.0             Peak Value
       Test setup:                       Below 1GHz




                                         Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                     Page 11 of 18


                                                                               Report No: CCISE181210206


       Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                           ground at a 3 meter semi-anechoic camber. The table was rotated 360
                                           degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and Specified
                                           Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of the
                                           EUT would be reported. Otherwise the emissions that did not have 10dB
                                           margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
       Test environment:                Temp.:       24 C         Humid.:     57%         Press.:    1 01kPa
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          All of the observed value above 6GHz ware the niose floor , which were no
                                        recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1812102
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


CCIS                                                                                    Report No: CCISE181210206

Measurement Data:
Below 1GHz:

Product Name:               4G Smart Phone                            Product Model:             Elite Go
Test By:                    Yaro                                      Test mode:                 PC mode

Test Frequency:             30 MHz ~ 1 GHz                            Polarization:             Vertical

Test Voltage:               AC 120/60Hz                               Environment:              Temp: 24°C      Huni: 57%


     80I.evel (dBuVi/m)


     70

     60
                                                                                                      FCC PART1S CLASS$ B8
     50

     40

     30

     20

     10


          30           50                      100                    200                             500               1000
                                                          Frequency (MHz)
                               Readintenna           Cable Preamp                        Linit        Over
                   Freq      Level Factor              Loss Factor           Level        Line       Limit Remark

               ______NHz dBu¥y dB/m — dB _ dB dBu¥/m dBu¥/m                                             dB
     1           56.991      52.04       12. 88        1.37      29.7T9      36.50       40.00 —3.50 QP
     2          121.123      50.04       10.03         2.18      290.38      32.87       43.50 —10.63 QP
     3          148. 963     59.92        8. 56        2.51      29.23       41.75       43.50 —1.75 QP
     4          195.137      48.27       11.36         2.84      28.86       33.61       43.50 —9.89 QP
     5          239.987      51.90       12.97         2.82      28.59       39.10       46.00 —6.90 qP
     6          T21.726      45.54       20.33         4.26      28.58       41.55       46.00 —4.45 QP

Remark:
1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1812102
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                     Page 13 of 18


CCIS                                                                                   Report No: CCISE181210206



Product Name:               4G Smart Phone                           Product Model:             Elite Go
Test By:                    Yaro                                     Test mode:                 PC mode

Test Frequency:             30 MHz ~ 1 GHz                           Polarization:              Horizontal

Test Voltage:               AC 120/60Hz                              Environment:              Temp: 24°C         Huni: 57%


     so Level (dBuVim)


     70

     60
                                                                                                     FCC PART15 CLAS$ B
     50                                                                                                           P

     40

     30

     20

     10


      G30              50                     100                  200                               500                  1000
                                                         Frequency (MHz)
                               Read&ntenna           Cable Preamp                       Limit         Over
                    Freq      Level Factor              Loss Factor          Level         Line     Limit Remark

              """NHz dBu¥ dB/m — dB _ dB dBu¥/m dBu¥/m — dB —
          1    147. 404       55. 72       8. 47       2.49      29.23       37.45      43.50       —6.05    qP
          2    195. 137       52.15       11.36        2.84      28.86       37.49      43.50       —6.01    QP
          3    227.691        56.09       12.55        2.84      28.66       42.82      46.00       —3.18    QP
          4    293.084        50.68       13.56        2.92      28.46       38.170     46.00       —7.30    qP
          5    480.528        47.62       16.97        3.46      28.92       39.13      46.00       —6.87    qP
          6    T21.726        48.40       20.33        4.26      28.58       44.41      46.00       —1.59    qP

Remark:
1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.    The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1812102
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                       Page 14 of 18


CCIS                                                                                   Report No: CCISE181210206

Above 1GHz:

Product Name:               4G Smart Phone                           Product Model:             Elite Go
Test By:                    Yaro                                     Test mode:                 PC mode

Test Frequency:             1 GHz ~ 6 GHz                            Polarization:              Vertical

Test Voltage:               AC 120/60Hz                              Environment:               Temp: 24°C        Huni: 57%

     80Level (dBuVi/m)
                                                                                                           FCC PART 15 (PK)
     70

     60
                                                                                                           FCC PART 15 (AV)
     50                                                                                                                  n

     40

     30

     20

     10


          1000     1200        1500               2000                                                          5000     6000
                                                         Frequency (MHz)
                               Readintenna           Cable Preamp                       Limnit       Over
                     Freq     Level Factor             Loss Factor          Level        Line       Linmit Renark

             ______NHz dBu¥ dB/m —db _dB dBu¥/m dBu¥/m —dB
      1          2862.693     46.35       28.35        5.20      41.61      38.29       74.00     —35.71      Peak
      2          2862.693     36.85       28.35        5.20      41.61      28.79       54.00     —25.21      Average
      3          4052.622     46.90       30.30        6.18      41.81      41.57       74.00     —32.43      Peak
      4          4052.622     37.14       30.30        6.18      41.81      31.81       54.00     —22.19      Average
      5          §747.456     51.72       32.86        T.74      41.96      50.36       74.00     —23.64      Peak
      6          5747.456     39.67       32.86        T.74      41.96      38.31       54.00     —15.69      Average

Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.    The emission levels of otherfrequencies are very lower than the limit and not show in test report,




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1812102
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                       Page 15 of 18


CCIS                                                                                    Report No: CCISE181210206



Product Name:                4G Smart Phone                           Product Model:             Elite Go
Test By:                     Yaro                                     Test mode:                 PC mode

Test Frequency:              1 GHz ~ 6 GHz                            Polarization:              Horizontal

Test Voltage:                AC 120/60Hz                              Environment:              Temp: 24°C         Huni: 57%

     80Level (dBuVim)

                                                                                                            FCC PART 15 (PK)
     70

     60
                                                                                                            FCC PART 15 (AV)
     50

     40

     30

     20

     10
     &




          1000     1200        1500                2000                                                          5000     6000
                                                          Frequency (MHz)
                               Readintenna            Cable Preamp
                     Freq     Level Factor             Loss Factor           Level         Line       Limit Remark

                   ~— NHz       dBu¥        dB/m dB
       1.        2534.314     46.39       21.68        4.57            90    37. 04          . 00    —36. 96     Peak
      2           2534.314    36.95       27.68        4.87            90    27. 60          . 00    —26.40      Average
      3           3665.723    46.42       29.35§       5.95            62    40.10           . 00    —33. 90     Peak
      4.         3665.723     3T.21       29.35        5.95            62    30. 89          .00     —23.11      Average
      §           §935.842    47.80       33.19        7.92            04    46.87           . 00    —27. 13     Peak
      6           §935.842    37.98       33.19        7.92            04    37. 05          .00     —16.95      Average

Remark:
1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1812102
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 16 of 18



Document Created: 2019-01-24 16:40:15
Document Modified: 2019-01-24 16:40:15

© 2025 FCC.report