RF EXPOSURE P3

FCC ID: 2ABOSPLAT50

RF Exposure Info

Download: PDF
FCCID_3031386

                                                                   ~                        1

                             SAR REFERENCE DIPOLE CALIBRATION REPORT                                             Ref: ACR.92.6.15.SATU.A



                                                                        Expanded Uncertainty
                                      1s                                             203 %
                                     10 g                                            20.1 %

   6     CALIBRATION MEASUREMENT RESULTS
   6.1        RETURN LOSS AND IMPEDANCE IN HEAD LIQUID
                                                              Frequency, MHz
                              1800    1820   1840   1860   1880    1900    1920     1940    190.     1980    2000
                   S11, 08




Frequency (MHz)                         Return Loss (dB)                  Requirement (dB)                            Impedance
      1900                                   —33.77                             —20                                 49.9 52 — 2.0 jC2

   6.2        RETURN LOSS AND IMPEDANCE IN BODY LIQUID
                                                              Frequency. MHz
                              1800    1820   1840   1eso   180     1900    1920     1940    190      1980    2000




                             an—
Frequency (MHz)                         Return Loss (dB)                  Requirement (dB)                              Impedance
       1900                                    —27.04                                 —20                           45.8 Q — 1.5 02




                                                           Page: 6/12

              This document shall not be reproduced, except infull or in part, without the written approval ofMVG
              The information contained herein isto be used onlyfor thepurpose for whichit is submitted and is not to
              be released in whole orpart without writien approval ofMVG


                                                                       ~                       1

                           SAR REFERENCE DIPOLE CALIBRATION REPORT                                                   Ref: ACR.92.6.15.SATU.A




       6.3       MECHANICAL DIMENSIONS
 Frequency MHz                          L mm                                        h mm                                     d mm

                           required             measured                required            measured             required           measured

      300                420.0 1 %.                                   250.0 1 %.                                6.35 +1 %.

      450                290.0 21 %.                                  166.7 21 %.                               6.35 £1 %.

      750                176.0 +1 %.                                  100.0 +1 %.                               6.35 +1 %.

      835                161.0 #1 %.                                   89.8 21 %.                                3.6 £1%.

      900                149.0 +1 %.                                   83.3 +1 %                                 3.641%.

     1450                 89.1 21 %.                                   51.7 41 %.                                3.6 21 %.

     1500                 80.5 +1 %.                                   50.0 #1 %.                                3.6:1%.
     1640                 79.0 £1%.                                    45.7 21 %.                                3.6+1%.

     1750                 75.2 41 %.                                   42.9 21 %.                                3.6 21 %.

     1800                 72.0 1 %.                                    41.7 +1 %                                 3.6+1%.

     1900                 68.0 +1 %.               pass                39.5 #1 %.              PaS$              3.6:1%.              PASS
     1950                 66.3 +1 %.                                   38.5 +1 %.                                3.6+1%.

     2000                 64.5 41 %.                                   37.5 41 %                                 3.641%.

     2100                 61.0 £1 %.                                   35.7 +1 %                                 3.6£1%.
     2300                 55.5 41 %.                                   32.6 +1 %                                 3.6+1%.

     2450                 51.5 41 %.                                   30.4 +1 %.                                3.6£1%.
     2600                 48.5 +1 %.                                   28.8 +1 %                                 3.6+1%.

     3000                 41.5 41 %.                                   25.0 #1 %.                                3.6 £1 %.

     3500                 37.0£1%.                                     264 +1 %.                                 3.6 £1%.

     3700                 34.721%.                                     264 21 %.                                 3.6 £1%.


       7     VALIDATION MEASUREMENT
The IEEE Std. 1528, FCC KDBs and CEVIEC 62209 standards state that the system validation
measurements must be performed using a reference dipole meeting the fore mentioned return loss
and mechanical dimension requirements. The validation measurement must be performed against a
liquid filled flat phantom, with the phantom constructed as outlined in the fore mentioned standards.
Per the standards, the dipole shall be positioned below the bottom ofthe phantom, with the dipole
length centered and parallel to the longest dimension of the flat phantom, with the top surface ofthe
dipole at the described distance from the bottom surface of the phantom.

       7.1   HEAD LIQUID MEASUREMENT

                          F'e;'fz"“’             Relative permittivity (€‘)              Conductivity (0) 5/m
                                                 required          measured            required         measured

                              300               45.3 15 %                             0.87 25 %
                              450               43.5 25 %                             0.87 £5 %


                                                               Page: 7/12

                 This document shall not be reproduced, except infull or in part, without the written approval ofMVG
                 The information contained herein is to be used onlyfor thepurpose for whichit is submitted and is not to
                 be released in whole orpart without writien approval ofMVG


                           SAR REFERENCE DIPOLE CALIBRATION REPORT                                                   Ref: ACR.92.6.15.SATU.A




                              750               41.9 25 %                             0.89 +5 %

                              835               41.5 25 %                             0.90 £5 %

                              900               41.5 15 %                             0.97 +5 %

                             1450               40.5 25 %                             120 25 %

                             1500               40.4 15 %                             1.23£5%
                             1640               40.2 25 %                             13125 %

                             1750               40.1 25 %                             1.37 25 %

                             1800               40.0 25 %                             14025 %

                             1900               40.0 25 %             PASS            14025 %              PASS

                             1950               40.0 15 %                             14025 %
                             2000               40.0 25 %                             14025 %

                             2100               39.8 25 %                             1.49 25 %

                             2300               39.5 25 %                             1.67 25 %

                             2450               39.2 25 %                             1.80 25 %

                             2600               39.0 25 %                             1.96 25 %

                             3000               38.5 25 %                             2.40 £5 %

                             3500               37.9 25 %                             2.91 45 %


        7.2      SAR MEASUREMENT RESULT WITH HEAD LIQUID
The IEEE Std. 1528 and CEUIEC 62209 standards state that the system validation measurements
should produce the SAR values shown below (for phantom thickness of 2 mm), within the
uncertainty for the system validation. All SAR values are normalized to 1 W forward power. In
bracket, the measured SAR is given with the used input power.

Software                                                               OPENSAR V4
Phantom                                                                SN 20/09 SAMT
Probe                                                                  SN 18/11 BPG122
Liquid                                                                 Head Liquid Values: eps® 40.9 sigma : 1.43
Distance between dipole center and liquid                              10.0 mm
Area scan resolution                                                   dx=8mm/dy=8mm
Zoon Scan Resolution                                                   dx=8mm/dy=8m/dz=5mm
Frequenc                                                               1900 MHz
Input power                                                            20 dBm
Liquid Temperature                                                     21°C
Lab Temperature                                                        21 °C
Lab Humidity                                                           45 %




                          F"’;‘fz"“’                 1 g SAR (W/ke/W)                     10 g SAR (W/ke/w)
                                                 required          measured            required         measured

                              300                  2.85                                  194

                              450                  4.58                                  3.06

                              750                  8.49                                  5.55


                                                               Page: 8/12

                 This document shall not be reproduced, except infull or in part, without the written approval ofMVG
                 The information contained herein is to be used onlyfor thepurpose for whichit is submitted and is not to
                 be released in whole orpart without writien approval ofMVG


                                                                    ~                         1

                        SAR REFERENCE DIPOLE CALIBRATION REPORT                                                    Ref: ACR.92.6.15.SATU—A




                                                                                        16

                                                                                       16.8

                                                                                       18.4

                                                                                       19.3

                                                                                      20.1

                                                               30.37 (3.94)           20.5          20.51 (2.05)
                                                                                      20.9
                                                                                      14
                                                                                      219
                                                                                      233
                                                                                       24
                             2600
                             3000
                             3500


               uks fie vew                       ns                                           /




           3                                                                            se
                                                                                        soo
 runtna                                                                               459
Catkes                                                                                $1
                                                                                      8 an
                                                                                        20
we )(
    4                                                                                   10
                                                                                        oo                                    .
                mm
                T ster 3 viea                                                             db a             fr m
                                                                                                              2indt a 2 a s a 4



     7.3       BODY LIQUID MEASUREMENT

                        Fehent                 Relative permittivity (€)              Conductivity (0) 5/m
                                              required           measured           required         measured

                             150              61.9 15 %                            0.80 25 %
                             300              58.2 15 %                            0.92 25 %
                             450              56.7 25 %                            0.94 25 %
                             750              55.5 45 %                            0.96 £5 %
                             835              55.2 45 %                            0.97 25 %
                             900              55.0 45 %                             1.05 25 %
                             915              55.0 15 %                             1.0625%
                                                            Page: 9/12

               This document shall not be reproduced, except infull or in part, without the written approval ofMVG
               The information contained herein isto be used onlyfor thepurpose for whichit is submitted and is not to
               be released in whole orpart without writien approval ofMVG


                                                                       ~                       1

                           SAR REFERENCE DIPOLE CALIBRATION REPORT                                                   Ref: ACR.92.6.15.SATU—A




                             1450               54.0 25 %                             1.30£5%
                             1610               53.8 45 %                             1.40£5%
                             1800               53.3 45 %                             1.525%
                             1900               53.3 45 %              Pass           1.5245%              pass
                            2000                53.3 15 %                             1.5225%
                            2100                53.2 45 %                             1.62+5%
                            2450                52.7 45 %                             1.95£5%
                            2600                52.5 15 %                             21625 %
                            3000                52.0 45 %                             27345 %
                            3500                51.3 45 %                             3.3125%
                            5200               49.0£10%                              5.30£10%
                            5300               48.9£10%                              5.42:10%
                            5400               48.7 £10%                             5.53210%
                            5500               48.6 210 %                            5.65 £10%
                            5600               48.5 £10%                             5.77210%
                            5800               48.2£10%                              6.00 £10%




           74   SAR MEASUREMENT RESULT WITH BODY LIQUID
Software                                                               OPENSAR V4
Phantom                                                                 SN 20/09 SAM7I
Probe                                                                  SN 18/11 BPG122
Liquid                                                                 Body Liquid Values: eps‘ 53.9 sigma 1.55
Distance between dipole center and liquid                              10.0 mm
Area scan resolution                                                   dx—8mm/dy—8mm
Zoon Scan Resolution                                                   dx=8mm/dy=8m/dz=5mm
Frequenc                                                               1900 MHz
Input power                                                            20 dBm
Liquid Temperature                                                     21 °C
Lab Temperature                                                        °o
Lab Humidity                                                           45.%



                          nexs                       18 SAR (W/ke/w)                      10 g SAR (W/ke/w)
                                                         measured                              measured
                             1900                       38.58 (3.96)                          20.37 (2.04)




                                                              Page: 10/12

                 This document shall not be reproduced, except infull or in part, without the written approval ofMVG
                 The information contained herein is to be used onlyfor thepurpose for whichit is submitted and is not to
                 be released in whole orpart without writien approval ofMVG


                                                     ~                        1

          SAR REFERENCE DIPOLE CALIBRATION REPORT                                                  Ref: ACR.92.6.15.SATU.A




uce taind ons




                                                                       $am
                                                                       § 30
                                                                         B
                    x                                                    osr—                               .
 T    Kter 3—   vien                                                         6              fr Smd
                                                                                               ud a 2 A 6 a b




                                            Page: 11/12

This document shall not be reproduced, except infull or in part, without the written approval ofMVG
The information contained herein isto be used onlyfor thepurpose for whichit is submitted and is not to
be released in whole orpart without writien approval ofMVG


 mvGo                       SAR REFERENCE DIPOLE CALIBRATION REPORT                                                    Ref: ACR.92.6.15.SATU.A




       8   LIST OF EQUIPMENT



                                                Equipment Summary Sheet

   Equipment                 Manufacturer / Identification No:        Current                                             Next Calibration
   Description                   Model                         *| Calibration Date                                              Date
   BAM Phantom                        mvo                  SN—20/09—SAM71              alidated. No cal                 alidated.        No   cal
                                                                                      required.                       required.
COMOSAR Test Bench                 versiona                          NA                 alidated. No cal                  alidated.      No   cal
                                                                                      required.                       required.
  Network Analyzer           Rhode8Schwarz                      sN100132                        o22013                          o22016
      Calipers                       Carrera                  CALIPER—01                        1272013                         122016

  Reference Probe                     MVG                  EPG122 SN 18711                      10/2014                         10/2015

     Multimeter                 Keithley 2000                     1188656                       12/2013                         1212016


  Signal Generator             Agilent E4438C                 MY49070581                        12/2013                         1212016

          :                                                                            Characterized prior to |Characterized prior to
      Ampiie:                    Aeifieisomes                     $~94s                test. No cal required. Jtest. No cal required.

    Power Meter                   HP E4418A                   US38261498                        12/2013                         1212016


   Power Sensor                 HP ECP—E26A                    Uss7181460                       1272013                         1222016
  esd                                    y                                             Characterized prior to |Characterized prior to
 Drectional Coupler            Nerds 4216—20                       01366               test. No cal required. Jtest. No cal required.
  Temperature and
  Humidity Sensor             Control Company                    11—661—9                        812012                         872015




                                                               Page: 12/12

                  This document shall not be reproduced, except in full or in part, without the written approval ofMVG.
                  The information contained herein is to be used onlyfor thepurpose for which it is submitted and is not to
                  be released in whole orpart without writien approal ofMVG


Reference No.: WTS16S0447679E V1              Page 110 of 113




16 SAR System Photos




                                      Liquid depth ≥ 15cm



Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn              Email:info@waltek.com.cn


Reference No.: WTS16S0447679E V1              Page 111 of 113




17 Setup Photos




              Right Head Cheek                                   Right Head Tilt




               Left Head Cheek                                   Left Head Tilt




                  1.0cm
                  separation                                           1.0cm
                                                                       separation



            Body-Worn(LCD UP)                              Body-Worn(LCD Down)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn              Email:info@waltek.com.cn


Reference No.: WTS16S0447679E V1              Page 112 of 113




                    1.0cm
                                                                      1.0cm
                    separation
                                                                      separation




              Hotpsot(LCD UP)                                   Hotspot(LCD Down)




                                                                     1.0cm
                   1.0cm                                             separation
                   separation




           Hotspot(RIGHT EDGE)                               Hotspot(LEFT EDGE)



                      1.0cm
                      separation




         Hotspot(BOTTOM EDGE)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn              Email:info@waltek.com.cn


Reference No.: WTS16S0447679E V1              Page 113 of 113




18 EUT Photos
Front side




Back side




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn              Email:info@waltek.com.cn