RF Exposure

FCC ID: 2ABO5-C78-16

RF Exposure Info

Download: PDF
FCCID_2622795

Maximum Permissible Exposure

FCCID:2ABO5-C78-16

Applicable Standard
Systems operating under the provisions of this section shall be operated in a manner that ensures
that the public is not exposed to radio frequency energy level in excess limit for maximum
permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this
device has been defined as a mobile device whereby a distance of 0.2m normally can be
maintained between the user and the device.
(a) Limits for Occupational / Controlled Exposure
                       Electric Field   Magnetic Field                        Averaging Times
 Frequency Range                                            Power Density           2       2
                       Strength (E)      Strength (H)                         ︱E︱ , ︱H︱
      (MHz)                                                 (S) (mW/cm2)
                          (V/m)             (A/m)                             or S (minutes)
       0.3-3.0              614               1.63              (100)*                6
       3.0-30             1842/f             4.89/f            (900/f)*               6
       30-300              61.4              0.163                1.0                 6
     300-1500                                                   F/300                 6
   1500-100000                                                     5                  6
(b) Limits for General Population / Uncontrolled Exposure
                       Electric Field   Magnetic Field                        Averaging Times
 Frequency Range                                            Power Density           2       2
                       Strength (E)      Strength (H)                         ︱E︱ , ︱H︱
      (MHz)                                                 (S) (mW/cm2)
                          (V/m)             (A/m)                             or S (minutes)
      0.3-1.34              614               1.63              (100)*               30
      1.34-30              824/f             2.19/f            (180/f)*              30
       30-300              27.5              0.073                0.2                30
     300-1500                                                   F/1500               30
   1500-100000                                                    1.0                30
Note: f=frequency in MHz; *Plane-wave equivalent power density

MPE Calculation Method
E (V/m) = (30*P*G) 0.5/d            Power Density: Pd (W/m2) = E2/377
E = Electric Field (V/m)
P = Peak RF output Power (W)
G = EUT Antenna numeric gain (numeric)
d = Separation distance between radiator and human body (m)
The formula can be changed to
Pd = (30*P*G) / (377*d2)
From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well
as the gain of the used antenna, the RF power density can be obtained.


Calculated Result and Limit

802.11b Mode
   Antenna                                   Power Density   Limit of Power
               Peak Output     Peak Output                                      Test
    Gain                                         (S)           Density (S)
               Power (dBm)     Power (mW)                                      Result
  (Numeric)                                    (mW/cm2)        (mW/cm2)
    1.585         21.63            145.55        0.046             1          Compiles




Note: 802.11b was the worse case



Document Created: 2015-05-08 00:14:37
Document Modified: 2015-05-08 00:14:37

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC