Test Report (JBP)_rev.pdf

FCC ID: 2ABCB-WLU6331

Test Report

Download: PDF
FCCID_2489336

                                                 FCC Certification Test Report

                       Report No.: FC141001C29

                       Test Model: WLU6331

                             FCC ID: 2ABCB-WLU6331

                 Received Date: Oct. 01, 2014

                         Test Date: Oct. 06 ~ Oct. 08, 2014

                     Issued Date: Nov. 03, 2014


                         Applicant: Raspberry Pi Trading Ltd

                           Address: Mount Pleasant House Mount Pleasant, Cambridge, Cambridgeshire,
                                    CB3 0RN, United Kingdom

                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 19, Hwa Ya 2nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan
                                 Hsien 333, Taiwan




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: FC141001C29                                               Page No. 1 / 24                                            Report Format Version: 6.1.0


                                                                    Table of Contents
Release Control Record .................................................................................................................................. 3
1     Certificate of Conformity ......................................................................................................................... 4
2     Summary of Test Results......................................................................................................................... 5
    2.1     Measurement Uncertainty ................................................................................................................... 5
    2.2     Modification Record ............................................................................................................................ 5
3     General Information ................................................................................................................................. 6
    3.1     Features of EUT .................................................................................................................................. 6
    3.2     General Description of EUT ................................................................................................................ 6
    3.3     Operating Modes of EUT and Determination of Worst Case Operating Mode ................................... 6
    3.4     Test Program Used and Operation Descriptions................................................................................. 6
    3.5     Primary Clock Frequencies of Internal Source ................................................................................... 6
    3.6     Miscellaneous...................................................................................................................................... 7
4     Configuration and Connections with EUT ............................................................................................. 8
    4.1     Connection Diagram of EUT and Peripheral Devices ......................................................................... 8
    4.2     Configuration of Peripheral Devices and Cable Connections ............................................................. 8
5     Conducted Emissions at Mains Ports .................................................................................................... 9
    5.1     Limits ................................................................................................................................................... 9
    5.2     Test Instruments .................................................................................................................................. 9
    5.3     Test Arrangement .............................................................................................................................. 10
    5.4     Test Results ........................................................................................................................................ 11
6     Radiated Emissions up to 1 GHz .......................................................................................................... 13
    6.1     Limits ................................................................................................................................................. 13
    6.2     Test Instruments ................................................................................................................................ 14
    6.3     Test Arrangement .............................................................................................................................. 15
    6.4     Test Results ....................................................................................................................................... 16
7     Radiated Emissions above 1 GHz......................................................................................................... 18
    7.1     Limits ................................................................................................................................................. 18
    7.2     Test Instruments ................................................................................................................................ 19
    7.3     Test Arrangement .............................................................................................................................. 20
    7.4     Test Results ....................................................................................................................................... 21
8     Pictures of Test Arrangements ............................................................................................................. 23
Appendix – Information on the Testing Laboratories ................................................................................ 24




Report No.: FC141001C29                                               Page No. 2 / 24                                              Report Format Version: 6.1.0


                                          Release Control Record


Issue No.             Description                                         Date Issued
FC141001C29           Original release.                                   Nov. 03, 2014




Report No.: FC141001C29                      Page No. 3 / 24       Report Format Version: 6.1.0


1    Certificate of Conformity


            Product: WiFi Adapter

              Brand: Raspberry Pi

        Test Model: WLU6331

    Sample Status: Engineering sample

          Applicant: Raspberry Pi Trading Ltd

          Test Date: Oct. 06 ~ Oct. 08, 2014

         Standards: 47 CFR FCC Part 15, Subpart B, Class B
                          ICES-003:2012 Issue 5, Class B
                          ANSI C63.4:2009



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                               , Date:       Nov. 03, 2014
                                 Polly Chien / Specialist




     Approved by :                                                , Date:       Nov. 03, 2014
                                Ken Liu / Senior Manager




Report No.: FC141001C29                         Page No. 4 / 24                      Report Format Version: 6.1.0


2      Summary of Test Results

47 CFR FCC Part 15, Subpart B / ICES-003:2012 Issue 5, Class B
ANSI C63.4:2009
  FCC    ICES-003
                                   Test Item                       Result/Remarks                 Verdict
 Clause    Clause
                       AC Power Line Conducted         Minimum passing Class B margin
    15.107     6.1                                                                             Pass
                       Emissions                       is -9.57 dB at 0.43906 MHz
                       Radiated Emissions up to 1      Minimum passing Class B margin
              6.2.1                                                                            Pass
                       GHz                             is -4.10 dB at 34.97 MHz
 15.109
                       Radiated Emissions above 1 Minimum passing Class B margin
              6.2.2                                                                            Pass
                       GHz                             is -23.47 dB at 2597.91 MHz
Note: There is no deviation to the applied test methods and requirements covered by the scope of this report.


2.1     Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
EUT:
The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note that
the uncertainty values are provided for informational purposes only and are not used in determining the
PASS/FAIL results.
                                                                                    Expended Uncertainty
                     Measurement                                 Frequency
                                                                                         (k=2) (±)
        Conducted Emissions at mains ports                  150kHz ~ 30MHz                2.44 dB
         Radiated Emissions up to 1 GHz                      30MHz ~ 1GHz                 4.70 dB
         Radiated Emissions above 1 GHz                       Above 1GHz                  2.26 dB


2.2     Modification Record
There were no modifications required for compliance.




Report No.: FC141001C29                        Page No. 5 / 24                        Report Format Version: 6.1.0


3      General Information
3.1      Features of EUT
The tests reported herein were performed according to the method specified by Raspberry Pi Trading Ltd, for
detailed feature description, please refer to the manufacturer's specifications or user's manual.

3.2      General Description of EUT

 Product                         WiFi Adapter
 Brand                           Raspberry Pi
 Test Model                      WLU6331
 Sample Status                   Engineering sample
 Operating Software              NA
 Power Supply Rating             5Vdc (host equipment)
 Accessory Device                NA
 Data Cable Supplied             NA

3.3      Operating Modes of EUT and Determination of Worst Case Operating Mode
The EUT consumes power from host, which designed with AC power supply of rating 100-240Vac, 50/60Hz.
For radiated emission evaluation, 230Vac/50Hz (for EN 55022 & AS/NZS CISPR 22) and 120Vac/60Hz (for
FCC Part 15) had been covered during the pre-test. The worst data was found at 120Vac/60Hz and recorded
in the applied test report.

EUT has been pre-tested under following test modes, and test mode 1 was the worst case for final test.
 Mode                                            Test Condition
  1    2.4G link, 120Vac/60Hz
  2    2.4G link, 230Vac/50Hz
  3    2.4G idle, 120Vac/60Hz

Test modes are presented in the report as below.
 Mode                                             Test Condition
                                         Conducted emission test
   -    2.4G link
                                          Radiated emission test
   -    2.4G link

3.4      Test Program Used and Operation Descriptions
a.    Plugged EUT into the notebook and placed on the testing table.
b.    The notebook sent “H” patterns to the screen and displayed them.
c.    The notebook sent “H” patterns to the printer and the printer printed them.
d.    The notebook read and wrote with the floppy.
e.    The notebook linked with the wireless router via the EUT.
f.    Steps b~e were repeated.


3.5      Primary Clock Frequencies of Internal Source
The highest frequency generated or used within the EUT or on which the EUT operates or tunes is 2.4 GHz
provided by Raspberry Pi Trading Ltd, for detailed internal source, please refer to the manufacturer's
specifications.


Report No.: FC141001C29                          Page No. 6 / 24                    Report Format Version: 6.1.0


3.6    Miscellaneous
Labelling Requirements for Part 15 Devices:
     Verification
The specific labelling requirements for a device subject to the Verification procedure are contained in Section
15.19(a). These labelling requirements are:
If the device is subject only to Verification, include a label bearing a unique identifier (Section 2.954) and one
of three compliance statements specified in Section 15.19(a). If the labeling area for the device is so small,
and/or it is not practical to place the compliance statement on the device, then the statement can be placed in
the user manual or product packaging (Section 15.19(a)(5)). However, the device must still be labelled with
the unique identifier (Verification). Generally, devices smaller than the palm of the hand are considered too
small for the compliance statement.
     Certification
If the device is subject to Certification: (1) Section 2.925 contains information on identification of the
equipment; (2) include a label bearing an FCC Identifier (FCC ID) (Section 2.926) and (3) include the
appropriate compliance statement in Section 15.19(a). If the device is considered too small and therefore it is
impractical (smaller than the palm of the hand) to display the compliance statement, then the statement may
be placed in the user manual or product packaging. However, the device must still be labelled with the FCC ID.
If the device is unquestionably too small for the FCC ID to be readable (smaller than 4-6 points), the FCC ID
may be placed in the user manual. However, it must be determined that the device itself is too small – the
label area allocated to the FCC ID may not be reduced because of over crowded identification of other
product and regulatory information.
An electronic display of the FCC ID (see 9. Electronic Labelling below) may be used for Certification of
Section 15.212 modular transmitters and software defined radios (Section 2.944).
     Declaration of Conformity (DoC):
The labelling requirements for a device subject to the DoC procedure are specified in Section 15.19(b). The
label should include the FCC logo along with the Trade Name and Model Number, which satisfies the unique
identifier requirement of Section 2.1074 if it represents the identical equipment tested for DoC compliance.
For personal computers assembled from authorized components, the following additional text must also be
included: “Assembled from tested components,” “Complete system not tested.” When the device is so small
and/or when it is not practical to place the required additional text on the device, the text may be placed in the
user manual or pamphlet supplied to the user. However, the FCC logo, Trade Name, and Model Number must
still be displayed on the device (Section 15.19(b)(3)).




                            Part 15 Declaration of Conformity (DoC) Label Examples
Equipment certified as software defined radio may use a means that readily displays the FCC ID on an
electronic display screen, instead of labelling the device (Section 2.925 (e)).
Further information may refer to FCC KDB:784748 D01 Labelling Part 15 &18 Guidelines
Labelling Requirements for ICES-003 Devices:
     Industry Canada ICES-003 Compliance Label:
CAN ICES-3 (*)/NMB-3(*)
* Insert either “A” or “B” but not both to identify the applicable Class of ITE.


Report No.: FC141001C29                          Page No. 7 / 24                         Report Format Version: 6.1.0


4        Configuration and Connections with EUT
4.1       Connection Diagram of EUT and Peripheral Devices




                                                Notebook (A)
                                                                      EUT

                                                       (1)
                                  (2)
                                                  Printer (B)

                                                  Floppy (C)



                                                                                                                  Remote site


                                                        Wireless N Dual band
                                                             Router (D)




4.2       Configuration of Peripheral Devices and Cable Connections
    ID         Product            Brand             Model No.             Serial No.              FCC ID               Remarks
    A.         Notebook           DELL            Latitude E6420          HPFC5Q1          FCC DoC Approved -
    B.          Printer          EPSON                 T22              MEEZ070388         FCC DoC Approved -
          External USB 1.1
    C.                            SONY               MPF82E               50010254         FCC DoC Approved -
                Floppy
           Wireless N Dual
    D.                            D-LINK             DIR-815           PVK21B5000399            KA21R815A1    -
            band Router
Note:
1. All power cords of the above support units are non-shielded (1.8m).
2. Item D acted as a communication partner to transfer data.


                                                                          Shielding
    ID          Descriptions               Qty.         Length (m)                     Cores (Qty.)                Remarks
                                                                          (Yes/No)
    1.   USB                                1                1.8             Y              0         -
    2.   USB                                1                0.5             Y              1         -
Note: The core(s) is(are) originally attached to the cable(s).




Report No.: FC141001C29                                         Page No. 8 / 24                              Report Format Version: 6.1.0


5     Conducted Emissions at Mains Ports
5.1    Limits
                                            Class A (dBuV)                           Class B (dBuV)
       Frequency (MHz)
                                   Quasi-peak               Average         Quasi-peak            Average
         0.15 - 0.5                      79                   66               66 - 56             56 - 46
         0.50 - 5.0                      73                   60                 56                  46
         5.0 - 30.0                      73                   60                 60                  50
Notes: 1. The lower limit shall apply at the transition frequencies.
       2. The limit decreases linearly with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.

5.2    Test Instruments

       Description &
                                   Model No.                     Serial No.       Cal. Date          Cal. Due
       Manufacturer
Test Receiver
                                    ESCS30                        100288        Apr. 24, 2014     Apr. 23, 2015
ROHDE & SCHWARZ
RF signal cable
                                     5D-FB                Cable-HYCO2-01        Dec. 27, 2013 Dec. 26, 2014
Woken
LISN
ROHDE & SCHWARZ                     ESH2-Z5                       100100        Dec. 23, 2013 Dec. 22, 2014
(EUT)
LISN
ROHDE & SCHWARZ                     ESH3-Z5                       100312        Jul. 10, 2014     Jul. 09, 2015
(Peripheral)
Software                        BV ADT_Cond_
                                                                    NA               NA                 NA
ADT                                V7.3.7.3

Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
          to NML/ROC and NIST/USA.
       2. The test was performed in HwaYa Shielded Room 2.
       3. The VCCI Site Registration No. is C-2047.




Report No.: FC141001C29                        Page No. 9 / 24                          Report Format Version: 6.1.0


5.3   Test Arrangement
a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected
   to the power mains through a line impedance stabilization network (LISN). Other support units were
   connected to the power mains through another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling
   impedance for the measuring instrument.
b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c. The test results of conducted emissions at mains ports are recorded of six worst margins for quasi-peak
   (mandatory) [and average (if necessary)] values against the limits at frequencies of interest unless the
   margin is 20 dB or greater.
Note: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP) and
      average detection (AV) at frequency 0.15MHz-30MHz.



                                     V e r tic a l G r o u n d
                                     R e fe r e n c e P la n e                                            T e s t R e c e iv e r


                                     EUT
                    40cm




                                                                     80cm
                    L IS N




                                                                                       H o r iz o n ta l G r o u n d
                                                                                       R e f e r e n c e P la n e

                     N o t e : 1 .S u p p o r t u n i ts w e r e c o n n e c t e d t o s e c o n d L IS N .
                              2 . B o t h o f L I S N s ( A M N ) a r e 8 0 c m f r o m E U T a n d a t le a s t 8 0 c m
                                 f r o m o t h e r u n its a n d o t h e r m e ta l p l a n e s




Report No.: FC141001C29                                   Page No. 10 / 24                                             Report Format Version: 6.1.0


5.4   Test Results
                                                            Detector Function &               ;
Frequency Range           150kHz ~ 3OMHz                    Resolution                Quasi—Peak (QP) /
                                                                   —                  Average (AV), OkHz
                                                            Bandwidth
                                                            Environmental               s
Input Power               120Vac, 60Hz (System)             Conditions                23°C , 66%RH

Tested by                 Mick Chou                         Test Date                 2014/10/6


                                              Phase Of Power: Line (L)
        Frequency     |Correction|    Reading Value       Emission Level                   Limit                 Margin
 No                       Factor         (dBuV)               (dBuV)                  (dBuV)                       (dB)
            (MHz)          (dB)       QP.      AV.         QP.      AV.            QP.      AV.              QP.          AV.
  1      0.34141          0.29        33.90     3243      34.19      32.72         §9.17          49.17    —24.97      —16.44
  2      0.44297          0.30        39.13     34.16     39.43      34.46         57.01          47.01    —17.57      —12.54
  3      0.54453          0.31        28.07     19.35     28.38      19.66         56.00          46.00    —27.62      —26.34
  4      0.86484          0.33        3248      23.40     32.81      23.73         56.00          46.00    —23.19      —22.27
  5        1.13281        0.34        2948      22.57     29.82      22.91         56.00          46.00    —26.18      —23.09
  6      2.02734          0.36        32.82     26.99     33.18      27.35         56.00          46.00    —22.82      —18.65
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value

                           aoue
                           no—                                                Prmase >
                           100—                                               or uime L
                            so—                                               cartine L




                             ols                  the                        who            sube
                                                                                             ie




Report No.: FC141001C29                           Page No. 11 / 24                                   Report Format Version: 6.1.0


                                                          Detector Function &              ;
Frequency Range           150kHz ~ 3OMHz                  Resolution                Quasi—Peak (QP) /
                                                                 —                  Average (AV), OkHz
                                                          Bandwidth
                                                          Environmental               s
Input Power               120Vac, 60Hz (System)           Conditions                23°C , 66%RH

Tested by                 Mick Chou                       Test Date                 2014/10/6


                                           Phase Of Power: Neutral (N)
        Frequency     |Correction|    Reading Value    Emission Level                Limit                    Margin
 No                       Factor          (dBuV)             (dBuV)                  (dBuV)                   (dB)
          (MHz)            (dB)        QP.      AV.       QP.      AV.            QP.      AV.           QP.        AV.
  1      0.23594           0.28       33.59    25.13     33.87    25.41          6224     52.24         —28.36 —26.82
  2      0.39609           0.30       39.47    37.60     39.77    37.90          57.93    47.93         —18.17 —10.04
  3      0.43906           0.30       38.10    37.21     38.40    37.51          57.08    47.08         —18.68     —9.57
  4      0.48203          0.31        32.28   23.71      3259      24.02         56.30         46.30    —23.72      —22.29
  5      2.07813          0.37        33.71   27.15      34.08     27.52         56.00         46.00    —21.92      —18.48
  6      242188           0.38        30.45   25.34      30.83     25.72         56.00         46.00    —25.17      —20.28
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value

                           aoue
                           no—                                              Prmase >
                           100—                                             or uime L
                            so—                                             cartine L




                             ols                 the                       who           sube
                                                                                          ie




Report No.: FC141001C29                          Page No. 12/ 24                                  Report Format Version: 6.1.0


6     Radiated Emissions up to 1 GHz
6.1    Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
                             Radiated Emissions Limits at 10 meters (dBμV/m)
  Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                   CISPR 22, Class A CISPR 22, Class B
      (MHz)             Class A                 Class B
      30-88                39                      29.5
      88-216              43.5                     33.1                    40                      30
     216-230
                          46.4                     35.6
     230-960
                                                                           47                      37
    960-1000              49.5                     43.5

                              Radiated Emissions Limits at 3 meters (dBμV/m)
    Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                 CISPR 22, Class A      CISPR 22, Class B
       (MHz)            Class A                Class B
       30-88              49.5                    40
       88-216              54                    43.5                   50.5                     40.5
      216-230
                           56.9                     46
      230-960
                                                                       57.5                      47.5
     960-1000              60                       54
Notes: 1. The lower limit shall apply at the transition frequencies.
       2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
       3. QP detector shall be applied if not specified.




Report No.: FC141001C29                       Page No. 13 / 24                       Report Format Version: 6.1.0


6.2   Test Instruments

       Description &
                                  Model No.                   Serial No.          Cal. Date         Cal. Due
       Manufacturer
Test Receiver
                                    ESR-7                         101240       Sep. 29, 2014 Sep. 28, 2015
ROHDE & SCHWARZ (V)
Test Receiver
                                    ESR-7                         101264       Nov. 29, 2013     Nov. 28, 2014
ROHDE & SCHWARZ (H)
BILOG Antenna
                                  VULB9168                    9168-148         Feb. 25, 2014     Feb. 24, 2015
SCHWARZBECK (V)
BILOG Antenna
                                  VULB9168                    9168-149         Feb. 25, 2014     Feb. 24, 2015
SCHWARZBECK (H)
Preamplifier
                                    8447D                   2944A10636         Oct. 18, 2013     Oct. 17, 2014
Agilent (V)
Preamplifier
                                    8447D                   2944A10637         Oct. 18, 2013     Oct. 17, 2014
Agilent (H)
Preamplifier
                                    8449B                   3008A01959         Oct. 18, 2013     Oct. 17, 2014
Agilent
RF signal cable
                                    8D-FB                 Cable-Hych1-01       Oct. 26, 2013     Oct. 25, 2014
Woken (V)
RF signal cable
                                    8D-FB                 Cable-Hych1-02       Oct. 26, 2013     Oct. 25, 2014
Woken (H)
Software                      BV ADT_Radiated_
                                                                   NA                NA                NA
BV ADT                            V 8.7.07
Antenna Tower (V)                 MFA-440                          9707              NA                NA
Antenna Tower (H)                 MFA-440                         970705             NA                NA
Turn Table                         DS430                           50303             NA                NA
Controller (V)                    MF7802                            074              NA                NA
Controller (H)                    MF7802                           08093             NA                NA

Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
          traceable to NML/ROC and NIST/USA.
       2. The test was performed in HwaYa Chamber 1.
       3. The FCC Site Registration No. is 477732.
       4. The IC Site Registration No. is IC 7450F-1.
       5. The VCCI Site Registration No. is R-1893.




Report No.: FC141001C29                        Page No. 14 / 24                        Report Format Version: 6.1.0


6.3   Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited test facility.
   The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 10 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the
   ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of
   the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
   the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
   hold mode when the test frequency is below 1 GHz.

Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
      quasi-peak detection (QP) at frequency below 1GHz.




Report No.: FC141001C29                        Page No. 15 / 24                        Report Format Version: 6.1.0


6.4   Test Results
                                                          Detector Function &
Frequency Range           30MHz ~ 1GHz                    Resolution            Quasi-Peak (QP), 120kHz
                                                          Bandwidth
Environmental
                          23℃, 67%RH                      Test Date             2014/10/7
Conditions
Tested by                 Daniel Lin

                              Antenna Polarity & Test Distance : Horizontal at 10 m
                          Emission                              Antenna       Table      Raw         Correction
        Frequency                       Limit       Margin
 No                         Level                                Height       Angle      Value        Factor
          (MHz)                       (dBuV/m)        (dB)
                          (dBuV/m)                                 (m)      (Degree)    (dBuV)        (dB/m)
  1       46.98           14.38 QP      30.00       -15.62       1.50 H        122       29.09        -14.71
  2       166.58          19.86 QP      30.00       -10.14       4.00 H        161       34.13        -14.27
  3       209.90          23.35 QP      30.00        -6.65       3.50 H        343       40.01        -16.66
  4       278.87          24.20 QP      37.00       -12.80       3.00 H        298       36.94        -12.74
  5       349.53          26.46 QP      37.00       -10.54       2.50 H        221       37.22        -10.76
  6       383.39          22.81 QP      37.00       -14.19       2.00 H         15       32.54         -9.73
  7       439.99          20.72 QP      37.00       -16.28       3.00 H        176       29.19         -8.47
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                         – Pre-Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level – Limit value




Report No.: FC141001C29                         Page No. 16 / 24                       Report Format Version: 6.1.0


                                                          Detector Function &
Frequency Range           30MHz ~ 1GHz                    Resolution            Quasi-Peak (QP), 120kHz
                                                          Bandwidth
Environmental
                          23℃, 67%RH                      Test Date             2014/10/7
Conditions
Tested by                 Daniel Lin

                               Antenna Polarity & Test Distance : Vertical at 10 m
                          Emission                             Antenna         Table     Raw         Correction
        Frequency                       Limit       Margin
 No                         Level                               Height        Angle      Value        Factor
          (MHz)                       (dBuV/m)        (dB)
                          (dBuV/m)                                (m)       (Degree)    (dBuV)        (dB/m)
  1       34.97           25.90 QP      30.00        -4.10      1.50 V          148      41.12        -15.22
  2       44.70           23.70 QP      30.00        -6.30      3.00 V          204      37.81        -14.11
  3       149.22          25.78 QP      30.00        -4.22      1.50 V           2       39.32        -13.54
  4       166.58          24.96 QP      30.00        -5.04      1.50 V           81      38.50        -13.54
  5       279.64          23.64 QP      37.00       -13.36      1.00 V          140      35.44        -11.80
  6       439.99          24.40 QP      37.00       -12.60      3.00 V          143      32.40         -8.00
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                         – Pre-Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level – Limit value




Report No.: FC141001C29                         Page No. 17 / 24                       Report Format Version: 6.1.0


7     Radiated Emissions above 1 GHz
7.1    Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
                             Radiated Emissions Limits at 10 meters (dBμV/m)
  Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                   CISPR 22, Class A CISPR 22, Class B
      (MHz)             Class A                  Class B
    1000-3000          Avg: 49.5                Avg: 43.5              Not defined           Not defined
   Above 3000         Peak:  69.5              Peak:  63.5             Not defined           Not defined

                             Radiated Emissions Limits at 3 meters (dBμV/m)
    Frequencies  FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                     CISPR 22, Class A CISPR 22, Class B
       (MHz)            Class A                   Class B
                                                                         Avg: 56             Avg: 50
  1000-3000
                        Avg: 60                   Avg: 54                Peak: 76           Peak: 70
                       Peak: 80                  Peak: 74                Avg: 60             Avg: 54
  Above 3000
                                                                         Peak: 80           Peak: 74
Notes: 1. The lower limit shall apply at the transition frequencies.
       2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
       3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
          average detector, however, the peak field strength of any emission shall not exceed the maximum
          permitted average limits, specified above by more than 20dB under any condition of modulation.
Frequency Range (For unintentional radiators)
 Highest frequency generated or used in the device or
                                                            Upper frequency of measurement range (MHz)
      on which the device operates or tunes (MHz)
                      Below 1.705                                               30
                          1.705-108                                            1000
                           108-500                                             2000
                           500-1000                                            5000
                                                          5th harmonic of the highest frequency or 40GHz,
                          Above 1000
                                                                        whichever is lower




Report No.: FC141001C29                      Page No. 18 / 24                         Report Format Version: 6.1.0


7.2   Test Instruments

       Description &
                                   Model No.                  Serial No.          Cal. Date          Cal. Due
       Manufacturer
Test Receiver
                                     ESCI                         100613        Oct. 24, 2013     Oct. 23, 2014
ROHDE & SCHWARZ
Spectrum Analyzer
                                    E4446A                  MY44360124          Feb. 12, 2014     Feb. 11, 2015
Agilent
BILOG Antenna
                                  VULB9168                    9168-157          Feb. 26, 2014 Feb. 25, 2015
SCHWARZBECK
RF signal cable
                                     8D-FB                         NA           Mar. 21, 2014     Mar. 20, 2015
Woken
HORN Antenna
                                 BBHA 9120 D                 9120D-404          Jan. 05, 2014     Jan. 04, 2015
SCHWARZBECK
Preamplifier
Agilent                             8447D                   2944A10629          Oct. 18, 2013     Oct. 17, 2014
(Below 1GHz)
Preamplifier
Agilent                              8449B                  3008A01959          Oct. 18, 2013     Oct. 17, 2014
(Above 1GHz)
RF signal cable                                      MWX322+MWX2211308
                               SUCOFLEX 104                            Nov. 07, 2013 Nov. 06, 2014
HUBER+SUHNER                                               S0295
Software                      BV ADT_Radiated_
                                                                   NA                NA                 NA
BV ADT                           V7.6.15.9.4
Antenna Tower
                                     AT100                  AT93021702               NA                 NA
BV ADT
Turn Table
                                     TT100                  TT93021702               NA                 NA
BV ADT
Controller
                                    SC100                   SC93021702               NA                 NA
BV ADT
HORN Antenna
                                  BBHA 9170                BBHA9170243          Jan. 09, 2014     Jan. 08, 2015
SCHWARZBECK
RF signal cable                                               38218/2+
                               SUCOFLEX 102                                     Oct. 26, 2013     Oct. 25, 2014
HUBER+SUHNNER                                                  37433/2
Fix tool for Boresight
                                    BAF-01                          2                NA                 NA
antenna tower

Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
          to NML/ROC and NIST/USA.
       2. The test was performed in HwaYa Chamber 2.
       3. The horn antenna and HP preamplifier (model: 8449B) are used only for the measurement of
          emission frequency above 1GHz if tested.
       4. The FCC Site Registration No. is 686814.
       5. The IC Site Registration No. is IC 7450F-2.
       6. The VCCI Site Registration No. is G-18.




Report No.: FC141001C29                        Page No. 19 / 24                         Report Format Version: 6.1.0


7.3   Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited chamber
   room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The height of antenna can be varied from one meter to four meters, the height of adjustment depends on
   the EUT height and the antenna 3dB beamwidth both, to detect the maximum value of the field strength.
   Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The spectrum analyzer system was set to peak and average detect function and specified bandwidth with
   maximum hold mode when the test frequency is above 1 GHz.

Note: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and video bandwidth is 3MHz for
      Peak detection (PK) at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
      analyzer is 1 MHz for Average detection (AV) at frequency above 1GHz.




Report No.: FC141001C29                     Page No. 20 / 24                       Report Format Version: 6.1.0


7.4   Test Results
                                                         Detector Function &
                                                                               Peak (PK) /
Frequency Range           1GHz ~ 18GHz                   Resolution
                                                                               Average (AV), 1MHz
                                                         Bandwidth
                                                         Environmental
Input Power               120Vac, 60Hz (System)                                22℃, 62%RH
                                                         Conditions
Tested by                 Rolan Zheng                    Test Date             2014/10/8

                              Antenna Polarity & Test Distance : Horizontal at 3 m
                          Emission                             Antenna       Table      Raw         Correction
        Frequency                       Limit      Margin
 No                         Level                               Height       Angle      Value        Factor
          (MHz)                       (dBuV/m)       (dB)
                          (dBuV/m)                                (m)      (Degree)    (dBuV)        (dB/m)
  1      1614.34          41.55 PK      74.00       -32.45      1.72 H        211       48.32         -6.77
  2      1614.34          27.77 AV      54.00       -26.23      1.72 H        211       34.54         -6.77
  3      2010.38          41.51 PK      74.00       -32.49      1.32 H        267       47.08         -5.57
  4      2010.38          27.84 AV      54.00       -26.16      1.32 H        267       33.41         -5.57
  5      2890.11          42.56 PK      74.00       -31.44      1.30 H         95       45.17         -2.61
  6      2890.11          26.39 AV      54.00       -27.61      1.30 H         95       29.00         -2.61
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                         – Pre-Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level – Limit value




Report No.: FC141001C29                        Page No. 21 / 24                       Report Format Version: 6.1.0


                                                          Detector Function &
                                                                                Peak (PK) /
Frequency Range           1GHz ~ 18GHz                    Resolution
                                                                                Average (AV), 1MHz
                                                          Bandwidth
                                                          Environmental
Input Power               120Vac, 60Hz (System)                                 22℃, 62%RH
                                                          Conditions
Tested by                 Rolan Zheng                     Test Date             2014/10/8

                                Antenna Polarity & Test Distance : Vertical at 3 m
                          Emission                             Antenna         Table      Raw         Correction
        Frequency                        Limit      Margin
 No                         Level                               Height         Angle      Value        Factor
          (MHz)                       (dBuV/m)       (dB)
                          (dBuV/m)                                 (m)       (Degree)    (dBuV)        (dB/m)
  1      1635.96          41.63 PK      74.00       -32.37      1.22 V          284       48.34         -6.71
  2      1635.96          24.58 AV      54.00       -29.42      1.22 V          284       31.29         -6.71
  3      2345.23          43.41 PK      74.00       -30.59      1.00 V          261       47.62         -4.21
  4      2345.23          27.41 AV      54.00       -26.59      1.00 V          261       31.62         -4.21
  5      2597.91          44.72 PK      74.00       -29.28      1.24 V          138       48.08         -3.36
  6      2597.91          30.53 AV      54.00       -23.47      1.24 V          138       33.89         -3.36
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                         – Pre-Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level – Limit value




Report No.: FC141001C29                         Page No. 22 / 24                        Report Format Version: 6.1.0


8    Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: FC141001C29                        Page No. 23 / 24   Report Format Version: 6.1.0


Appendix – Information on the Testing Laboratories

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and
approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                       Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-5935343
Fax: 886-2-26051924                                    Fax: 886-3-5935342

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: FC141001C29                        Page No. 24 / 24                     Report Format Version: 6.1.0



Document Created: 2019-09-28 14:48:31
Document Modified: 2019-09-28 14:48:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC