15U21916-S1V1 SAR_App B System Check Plots

FCC ID: 2AB8ZND11

RF Exposure Info

Download: PDF
FCCID_2785067

Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 9/28/2015 10:25:06 AM

20150928 SystemPerformanceCheck-D2450V2 SN 706

Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 2450 MHz; σ = 1.875 S/m; εr = 38.417; ρ = 1000 kg/m
                                                                                3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/7/2014
- Probe: EX3DV4 - SN7356; ConvF(7.89, 7.89, 7.89); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM; Type: QD000P40CD; Serial: TP 1751

Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.07 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 65.044 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 12.1 W/kg
SAR(1 g) = 5.57 W/kg; SAR(10 g) = 2.52 W/kg
Maximum value of SAR (measured) = 8.07 W/kg




                      0 dB = 8.07 W/kg = 9.07 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc., SAR Lab 1   Date/Time: 9/28/2015 10:45:09 AM

20150928 SystemPerformanceCheck-D2450V2 SN 706
Frequency: 2450 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 7.91 W/kg




                                                                                           Plot No. 2



Document Created: 2015-09-30 11:14:55