Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 10/13/2015 4:33:10 PM

20151013_SystemPerformanceCheck-D2450V2 SN 899

Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 2450 MHz; σ = 1.989 S/m; εr = 50.247; ρ = 1000 kg/m
                                                                                3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/7/2014
- Probe: EX3DV4 - SN7356; ConvF(7.54, 7.54, 7.54); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI-A v5.0; Type: QDOVA002AA; Serial: TP 1194

Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.15 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 62.329 V/m; Power Drift = 0.15 dB
Peak SAR (extrapolated) = 10.9 W/kg
SAR(1 g) = 5.2 W/kg; SAR(10 g) = 2.4 W/kg
Maximum value of SAR (measured) = 7.37 W/kg




                      0 dB = 7.37 W/kg = 8.67 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc., SAR Lab 1   Date/Time: 10/13/2015 4:53:38 PM

20151013_SystemPerformanceCheck-D2450V2 SN 899
Frequency: 2450 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 5.22 W/kg