SAR Report 17mm revised

FCC ID: 2AB8ZND1

RF Exposure Info

Download: PDF
FCCID_2373412

  SAR EVALUATION REPORT
       FCC 47 CFR § 2.1093
        IEEE Std 1528-2013


               For
       802.11abgn w/BT 4.0

         Model: EDISON
        FCC ID: 2AB8ZND1

   Report Number: 14U17814-S3A
       Issue Date: 8/27/2014

            Prepared for
       INTEL CORPORATION
2200 MISSION COLLEGE BOULEVARD
   SANTA CLARA, CA 95052, U.S.A

             Prepared by
    UL Verification Services Inc.
      47173 BENICIA STREET
    FREMONT, CA 94538, U.S.A.
        TEL: (510) 771-1000
        FAX: (510) 661-0888




      NVLAP LAB CODE 200065-0


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

REVISION HISTORY
 Rev.    Issue Date     Revisions                                                          Revised By
 --      8/23/2014      Initial Issue                                                      --
 A       8/27/2014      Removed Hotspot references                                         Dave Weaver




                                                    Page 2 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                                                          Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

                                                                 Table of Contents

1.          Attestation of Test Results ......................................................................................................... 5

2.          Test Specification, Methods and Procedures............................................................................ 6

3.          Facilities and Accreditation ........................................................................................................ 6

4.          SAR Measurement System & Test Equipment .......................................................................... 7
     4.1.      SAR Measurement System ........................................................................................................ 7
     4.2.      Test Equipment.......................................................................................................................... 8

5.          Measurement Uncertainty ........................................................................................................... 9

6.          Device Under Test (DUT) Information ...................................................................................... 10
     6.1.      DUT Description ...................................................................................................................... 10
     6.2.      Wireless Technologies ............................................................................................................. 10
     6.3.      Simultaneous Transmission ..................................................................................................... 10
     6.4.      Maximum Output Power .......................................................................................................... 10
     6.5.      Test Rational ........................................................................................................................... 11
     6.4 Antenna Dimensions and Separation Distances ........................................................................... 11

7.          RF Exposure Conditions (Test Configurations) ...................................................................... 12
     7.1.      Body ........................................................................................................................................ 12

8.          Conducted Output Power Measurements................................................................................ 13
     8.1.      Wi-Fi (2.4 GHz Band)............................................................................................................... 13

9.          Dielectric Property Measurements ........................................................................................... 14
     9.1.      Tissue Dielectric Parameters ................................................................................................... 15
     9.2.      Dielectric Property Measurements Results .............................................................................. 16

10.         System Check ............................................................................................................................ 17
     10.1.        Reference Target SAR Values ............................................................................................. 17
     10.2.        System Check Results ......................................................................................................... 17

11.         Measured and Reported (Scaled) SAR Results ....................................................................... 18
     11.1.        Wi-Fi (DTS Band) ................................................................................................................. 19

12.         SAR Measurement Variability ................................................................................................... 20
     12.1.        The Highest Measured SAR Configuration in Each Frequency Band ................................... 20

13.         Appendixes ................................................................................................................................ 21
     13.1.        Photos and Antenna Locations ............................................................................................. 21
     13.2.        System Performance Check Plots ........................................................................................ 21
     13.3.        Highest SAR Test Plots ........................................................................................................ 21
                                                    Page 3 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                                  Issue Date: 8/27/2014
FCC ID: 2AB8ZND1
  13.4.     Calibration Certificate for E-Field Probe EX3DV4 - SN 3749 ................................................ 21
  13.5.     Calibration Certificate for D2450V2 - SN 899 ....................................................................... 21




                                                    Page 4 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

  1.                   Attestation of Test Results
 Applicant Name            INTEL CORPORATION
 Application Purpose             Original Grant   Class II Permissive Change
 FCC ID                    2AB8ZND1
 IC Certification ID       1000X-ND1
 DUT Description           802.11abgn w/BT 4.0
 Exposure Category         General Population/Uncontrolled Exposure (1g SAR limit: 1.6 W/kg)
 The highest reported                                                           Equipment Class
                           RF Exposure Conditions
 SAR                                                            Licensed             DTS                  UNII
                           Body-worn Accessory                     N/A            0.369W /kg              N/A
 Applicable Standards      FCC 47 CFR § 2.1093
                           KDB publication
                           IEEE Std 1528-2013
 Test Results              Pass
 Date tested               07/24/2014 – 08/01/2014
 UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
 above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services
 Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
 account and are published for informational purposes only. The test results show that the equipment tested is
 capable of demonstrating compliance with the requirements as documented in this report.
 Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
 operation as described herein. This document may not be altered or revised in any way unless done so by UL
 Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this
 document not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document.
 This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP,
 NIST, any agency of the Federal Government, or any agency of any government (NIST Handbook 150, Annex
 A). This report is written to support regulatory compliance of the applicable standards stated above.
 Approved & Released By:                                    Prepared By:




 Dave Weaver                                                Coltyce Sanders
 Program Manager                                            Laboratory Engineer
 UL Verification Services Inc.                              UL Verification Services Inc.




                                                    Page 5 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1


 2.     Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-,
the following FCC Published RF exposure KDB procedures, and TCB workshop updates:
    o 447498 D01 General RF Exposure Guidance v05r02
    o 248227 D01 SAR Meas for 802 11abg v01r02
    o 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r03
    o 865664 D02 SAR Reporting v01r01
    o 690783 D01 SAR Listings on Grants v01r03


 3.     Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

 47173 Benicia Street                             47266 Benicia Street
 SAR Lab A                                        SAR Lab 1
 SAR Lab B                                        SAR Lab 2
 SAR Lab C                                        SAR Lab 3
 SAR Lab D                                        SAR Lab 4
 SAR Lab E                                        SAR Lab 5
 SAR Lab F
 SAR Lab G
 SAR Lab H

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation
can be viewed at http://ts.nist.gov/standards/scopes/2000650.htm.




                                                    Page 6 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                            Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

 4.      SAR Measurement System & Test Equipment
 4.1. SAR Measurement System
The DASY5 system used for performing compliance tests consists of the following items:




     A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
      accommodating the data acquisition electronics (DAE).
     An isotropic Field probe optimized and calibrated for the targeted measurement.
     A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
      conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is battery
      powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
     The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital
      communication to the DAE. To use optical surface detection, a special version of the EOC is required. The
      EOC signal is transmitted to the measurement server.
     The function of the measurement server is to perform the time critical tasks such as signal filtering, control of
      the robot operation and fast movement interrupts.
     The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.
     A computer running WinXP or Win7 and the DASY5 software.
     Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.
     The phantom, the device holder and other accessories according to the targeted measurement.




                                                    Page 7 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                               Issue Date: 8/27/2014
FCC ID: 2AB8ZND1


 4.2. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations, and is traceable to recognized national standards.
Dielectric Property Measurements
Name of Equipment                          Manufacturer             Type/Model            Serial No.        Cal. Due Date
Network Analyzer                              Agilent           ENA Series/E5071B       MY42100131            2/24/2015
Dielectronic Probe kit                        SPEAG                  DAK-3.5                  1087           11/13/2014
Dielectronic Probe kit                        SPEAG                DAK-3.5 Short      SM DAK 200 BA                 N/A
Thermometer                              Control Company               4242              122529163            9/19/2014
Thermometer                                  EXTECH                   445703              CCS-200             3/24/2015


System Check
Name of Equipment                        Manufacturer            Type/Model          Serial No.        Cal. Due Date
HP Signal Generator                          HP                    8665B            3546A00784          6/23/2015
Power Meter                                  HP                    437B             3125U16345          6/16/2015
Power Meter                                  HP                    437B             3125U09516          9/30/2014
Power Sensor                                Agilent                8481A            2237A31744          10/2/2014
Power Sensor                                Agilent                8481A            2349A36506          9/30/2014
Amplifier                                   MITEQ          AMF-4D-00400600-50-30P     1808939              N/A
Bi-directional coupler                  Werlatone, Inc.          C8060-102             2710                N/A
DC Power Supply                        Sorensen Ametek             XT15-4           1319A02778             N/A
HP Signal Generator                          HP                    8665B            3438A00633          7/10/2015
Power Meter                                  HP                    438A             3513U04320          10/2/2014
Power Sensor                                Agilent                8481A            2702A66876          9/30/2014
Power Sensor                                Agilent                8481A            3318A95392          9/30/2014
Amplifier                                   MITEQ          AMF-4D-00400600-50-30P     1622052              N/A
Bi-directional coupler                  Werlatone, Inc.          C8060-102             2711                N/A
DC Power Supply                              HP                    6296A            2841A-05955            N/A
E-Field Probe (SAR 3)                      SPEAG                  EX3DV4               3773             4/22/2015
Data Acquisition Electronics (SAR 3)       SPEAG                   DAE4                1343             7/24/2014
Data Acquisition Electronics (SAR 3)       SPEAG                   DAE4                1257              4/2/2015
System Validation Dipole                   SPEAG                  D2450V2               899             9/10/2014
System Validation Dipole                   SPEAG                 D5GHzV2               1138             11/19/2014
Thermometer (SAR Lab 3)                    EXTECH                 445703             CCS-237             6/3/2015




                                                    Page 8 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

  5.                 Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg, the extensive SAR measurement uncertainty analysis described in IEEE Std 1528-
2003 & 2013 is not required in SAR reports submitted for equipment approval.




                                                    Page 9 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                               Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

6.         Device Under Test (DUT) Information
6.1. DUT Description
 Model: EDISON
 Device Dimension                     Overall (Length x Width): 24.86 mm x 35.64 mm
                                      Overall Diagonal: 43.08 mm

6.2. Wireless Technologies
 Wireless                   Frequency bands         Operating mode                    Duty Cycle used for SAR testing
 technologies
 Wi-Fi                      2.4 GHz                 802.11b                           100%
                                                    802.11g
                                                    802.11n (HT20)
                                                    802.11n (HT40)
                            5 GHz                   802.11a                           100%
                                                    802.11n (HT20)
                                                    802.11n (HT40)
 Bluetooth                  2.4 GHz                 Version 4.0 LE                    32.25% (DH1), 66.68% (DH3), 77.52% (DH5)


6.3. Simultaneous Transmission
Bluetooth and 2.4 GHz WI-Fi cannot transmit simultaneously.
Bluetooth and 5 GHz WI-Fi can transmit simultaneously.
6.4. Maximum Output Power
Target powers are absolute maximums
                                               RF Output Power (dBm)
 RF Air interface           Mode                       Target
                           802.11b                      15.8
                           802.11g                      17.1
     WiFi 2.4 GHz
                      802.11n HT20                      17.1
                      802.11n HT40                      14.2
                           802.11a                      13.3
     WiFi 5.2 GHz     802.11n HT20                      13.7
                      802.11n HT40                      11.2
                           802.11a                      13.8
     WiFi 5.3 GHz     802.11n HT20                      14.2
                      802.11n HT40                      13.2
                           802.11a                      13.2
     WiFi 5.6 GHz     802.11n HT20                      14.2
                      802.11n HT40                      13.2
                           802.11a                      13.5
     WiFi 5.8 GHz     802.11n HT20                      14.1
                      802.11n HT40                      13.0
               Bluetooth                                 5.4




                                                   Page 10 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

6.5. Test Rational
The DUT previously underwent SAR testing at reduced power levels in the 2.4 GHz band at 5mm test
separation distance. (See UL SAR test report 14U17814-S1A). This report contains SAR test results at
full power at a separation distance of 17mm. SAR testing for Bluetooth and in the 5GHz bands at 17mm
was not necessary as testing at the maximum power was already reported in UL SAR test report
14U17814-S1A at 5mm.
6.4 Antenna Dimensions and Separation Distances




                                                   Page 11 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

 7.       RF Exposure Conditions (Test Configurations)
Refer to Appendix “Antenna Locations and Separation Distances” for the specific details of the antenna-
to-antenna and antenna-to-edge(s) distances.

 7.1. Body
                       Antenna-to-    SAR
 Test Configurations   edge/surface   Required     Note
 Rear                  1 mm           Yes
 Front                 0 mm           Yes
 Edge 1 (Top)          21.31 mm       Yes
 Edge 2 (Right)        22.89 mm       Yes
 Edge 3 (Bottom)       0.97 mm        Yes
 Edge 4 (Left)         2.55 mm        Yes




                                                   Page 12 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                                            Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

 8. Conducted Output Power Measurements
The proprietary logic is used to determine when head/body power table is used.
8.1. Wi-Fi (2.4 GHz Band)
Required Test Channels per KDB 248227 D01
                                                                                                           “Default Test Channels”
         Mode                     Band                       GHz               Channel
                                                                                                      802.11b                 802.11g
                                                            2.412                 1#                                             
       802.11b/g                 2.4 GHz                    2.437                  6                                             
                                                            2.462                 11#                                            
 Notes:
  = “default test channels”
  = possible 802.11g channels with maximum average output ¼ dB  the “default test channels”
 #
   = when output power is reduced for channel 1 and /or 11 to meet restricted band requirements the highest output channels closest to each
 of these channels should be tested.

Measured Results
     Band                                                              Freq.      Avg Pwr (dBm)       SAR Test
                     Mode          Data Rate           Ch #
    (GHz)                                                             (MHz)                           (Yes/No)
                                                        1              2412              13.3
                    802.11b          1 Mbps             6              2437              14.1            Yes
                                                        11             2462              15.8
                                                        1              2412              14.1
                    802.11g          6 Mbps             6              2437              17.0            Yes
     2.4                                                11             2462              17.1
    (DTS)                                               1              2412              14.0
                    802.11n
                                     MCS0               6              2437              17.1            Yes
                    (HT20)
                                                        11             2462              17.1
                                                        3              2422              11.1
                    802.11n
                                     MCS0               6              2437              14.2            Yes
                    (HT40)
                                                        9              2452              12.1




                                                   Page 13 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1



   9.    Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18C to 25C and
within ± 2C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.




                                                   Page 14 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                                  Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

9.1. Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                                               Head                                Body
     Target Frequency (MHz)
                                                  er                        s (S/m)          er              s (S/m)
               150                               52.3                        0.76           61.9              0.80
               300                               45.3                        0.87           58.2              0.92
               450                               43.5                        0.87           56.7              0.94
               835                               41.5                        0.90           55.2              0.97
               900                               41.5                        0.97           55.0              1.05
               915                               41.5                        0.98           55.0              1.06
              1450                               40.5                        1.20           54.0              1.30
              1610                               40.3                        1.29           53.8              1.40
           1800 – 2000                           40.0                        1.40           53.3              1.52
              2450                               39.2                        1.80           52.7              1.95
              3000                               38.5                        2.40           52.0              2.73
              5000                               36.2                        4.45           49.3              5.07
              5100                               36.1                        4.55           49.1              5.18
              5200                               36.0                        4.66           49.0              5.30
              5300                               35.9                        4.76           48.9              5.42
              5400                               35.8                        4.86           48.7              5.53
              5500                               35.6                        4.96           48.6              5.65
              5600                               35.5                        5.07           48.5              5.77
              5700                               35.4                        5.17           48.3              5.88
              5800                               35.3                        5.27           48.2              6.00


IEEE Std 1528-2013
                                                             Head
     Target Frequency (MHz)
                                                 er                       s (S/m)
                300                             45.3                        0.87
                450                             43.5                        0.87
                750                             41.9                       0.89
                835                             41.5                        0.90
                900                             41.5                        0.97
               1450                             40.5                        1.20
               1500                             40.4                       1.23
               1640                             40.2                       1.31
               1750                             40.1                       1.37
               1800                             40.0                        1.40
               1900                             40.0                        1.40
               2000                             40.0                        1.40
               2100                             39.8                       1.49
               2300                             39.5                       1.67
               2450                             39.2                        1.80
               2600                             39.0                       1.96
               3000                             38.5                        2.40
               3500                             37.9                       2.91
               4000                             37.4                       3.43
               4500                             36.8                       3.94
               5000                             36.2                       4.45
               5200                             36.0                       4.66
               5400                             35.8                       4.86
               5600                             35.5                       5.07
               5800                             35.3                        5.27
               6000                             35.1                       5.48
NOTE—For convenience, permittivity and conductivity values at some frequencies
that are not part of the original data from Drossos et al. [B60] or the extension to 5800
MHz are provided (i.e., the values shown in italics). These values were linearly
interpolated between the values in this table that are immediately above and below
these values, except the values at 6000 MHz that were linearly extrapolated from the
values at 3000 MHz and 5800 MHz.




                                                   Page 15 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                                 Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

9.2. Dielectric Property Measurements Results
The temperature of the tissue-equivalent medium used during measurement must also be within 18C to 25C and
within ± 2C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.

SAR Lab 3
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target   Delta (%)   Limit ±(%)
                              e'   50.5300             Relative Permittivity (єr):    50.53     52.70      -4.12         5
                Body 2450
                              e"   14.8500                     Conductivity (σ):       2.02     1.95       3.74          5
                              e'   50.7000             Relative Permittivity (єr):    50.70     52.76      -3.90         5
   7/28/2014    Body 2410
                              e"   14.7000                     Conductivity (σ):       1.97     1.91       3.27          5
                              e'   50.4200             Relative Permittivity (єr):    50.42     52.67      -4.27         5
                Body 2475
                              e"   14.9600                     Conductivity (σ):       2.06     1.99       3.71          5
                              e'   51.8000             Relative Permittivity (єr):    51.80     52.70      -1.71         5
                Body 2450
                              e"   14.4100                     Conductivity (σ):       1.96     1.95       0.67          5
                              e'   51.9700             Relative Permittivity (єr):    51.97     52.76      -1.50         5
   7/31/2014    Body 2410
                              e"   14.2500                     Conductivity (σ):       1.91     1.91       0.11          5
                              e'   51.6800             Relative Permittivity (єr):    51.68     52.67      -1.88         5
                Body 2475
                              e"   14.5100                       Conductivity (σ):     2.00     1.99       0.59          5




                                                   Page 16 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                                              Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

 10. System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are remeasured or sooner when marginal
liquid parameters are used at the beginning of a series of measurements.

10.1. Reference Target SAR Values
The reference SAR values can be obtained from the calibration certificate of system validation dipoles
                                                                                            Target SAR Values (W/kg)
  System Dipole          Serial No.       Cal. Date         Freq. (MHz)
                                                                                   1g/10g              Head                Body
                                                                                    1g                  51.3               49.70
    D2450V2                 899           9/10/2013              2450
                                                                                    10g                 23.9                23.3

10.2. System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within 10% of the manufacturer calibrated dipole SAR target.
SAR Lab 3
                   System Dipole                                Measured Results               Target
                                           T.S.                                                                Delta     Est./Zoom   Plot
Date Tested                                             Area                  Normalize         (Ref.
                  Type       Serial #     Liquid                  Zoom Scan                                    ±10 %       Ratio     No.
                                                        Scan                   to 1 W          Value)
                                                   1g   5.02         5.06          50.6        49.70           1.81        -0.80
 7/28/2014    D2450V2          899      Body
                                               10g      2.140        2.340         23.4        23.30           0.43
                                                   1g   5.33         5.40          54.0        49.70           8.65        -1.31
 7/31/2014    D2450V2          899      Body
                                               10g      2.260        2.510         25.1        23.30           7.73




                                                   Page 17 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                                Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

11.     Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:

KDB 447498 D01 General RF Exposure Guidance:
Testing of other required channels within the operating mode of a frequency band is not required when the reported 1-g or 10-g
SAR for the mid-band or highest output power channel is:
   ≤ 0.8 W/kg or 2.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≤ 100 MHz
   ≤ 0.6 W/kg or 1.5 W/kg, for 1-g or 10-g respectively, when the transmission band is between 100 MHz and 200 MHz
   ≤ 0.4 W/kg or 1.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≥ 200 MHz

KDB 248227 D01 SAR Measurements Procedures for 802.11 a/b/g Transmitters v01r02 (pg.6):
Each channel should be tested at the lowest data rate in each a-b/g mode or 4.9 GHz channel BW configuration.
When the extrapolated maximum peak SAR for the maximum output channel is ≤ 1.6 W/kg and the 1-g averaged SAR is ≤ 0.8
W/kg, testing of other channels in the “default test channels” or “required test channels” configuration is optional.

April 2013 TCB Workshop Updates:
Apply usual 802.11 test exclusion considerations, but include 802.11ac SAR for highest 802.11a configuration in each frequency
band and each exposure condition.




                                                   Page 18 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                               Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

11.1. Wi-Fi (DTS Band)
                                                                                       Power (dBm)    1-g SAR (W/kg)
 Frequency   RF Exposure                   Dist.                            Freq.                                       Plot
                             Mode                  Test Position   Ch #.            Tune-up
   Band       Conditions                  (mm)                             (MHz)              Meas.   Meas.    Scaled   No.
                                                                                      limit
                                                       Rear         11     2462      15.8      15.8   0.158    0.158
                                                      Front         11     2462      15.8      15.8   0.158    0.158
                            802.11b                  Edge 1         11     2462      15.8      15.8   0.026    0.026
  2.4GHz        Body                       17
                            1 Mbps                   Edge 2         11     2462      15.8      15.8   0.015    0.015
                                                      Edge 3        11     2462      15.8      15.8   0.053    0.053
                                                      Edge 4        11     2462      15.8      15.8   0.060    0.060
                                                       Rear         6      2437      17.1      17.1   0.097    0.097
                                                      Front         6      2437      17.1      17.1   0.158    0.158
                            802.11g                  Edge 1         6      2437      17.1      17.1   0.035    0.035
  2.4GHz        Body                       17
                            6 Mbps                   Edge 2         6      2437      17.1      17.1   0.020    0.020
                                                      Edge 3        6      2437      17.1      17.1   0.079    0.079
                                                      Edge 4        6      2437      17.1      17.1   0.099    0.099
                                                       Rear         6      2437      17.1      17.1   0.164    0.165
                                                      Front         6      2437      17.1      17.1   0.369    0.369
                           802.11n    6
                                                     Edge 1         6      2437      17.1      17.1   0.017    0.017
  2.4GHz        Body          Mbps         17
                              HT20                   Edge 2         6      2437      17.1      17.1   0.019    0.019
                                                      Edge 3        6      2437      17.1      17.1   0.079    0.079
                                                      Edge 4        6      2437      17.1      17.1   0.098    0.098
                                                       Rear         6      2437      14.2      14.2   0.164    0.164
                                                      Front         6      2437      14.2      14.2   0.056    0.056
                            802.11n
                                                     Edge 1         6      2437      14.2      14.2   0.018    0.018
  2.4GHz        Body         MCS0          17
                             HT40                    Edge 2         6      2437      14.2      14.2   0.011    0.011
                                                      Edge 3        6      2437      14.2      14.2   0.039    0.039
                                                      Edge 4        6      2437      14.2      14.2   0.050    0.050




                                                   Page 19 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

 12. SAR Measurement Variability
In accordance with published RF Exposure KDB procedure 865664 D01 SAR measurement 100 MHz to 6 GHz
v01. These additional measurements are repeated after the completion of all measurements requiring the same
head or body tissue-equivalent medium in a frequency band. The test device should be returned to ambient
conditions (normal room temperature) with the battery fully charged before it is re-mounted on the device holder for
the repeated measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is < 0.80 W/kg; steps 2)
   through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.80 W/kg, repeat that measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or when the original or repeated measurement is ≥ 1.45 W/kg (~ 10% from
   the 1-g SAR limit).
4) Perform a third repeated measurement only if the original, first or second repeated measurement is ≥1.5 W/kg
   and the ratio of largest to smallest SAR for the original, first and second repeated measurements is > 1.20.
12.1.           The Highest Measured SAR Configuration in Each Frequency Band
  Frequency Band                               Head                         Body-worn                  Repeated SAR
                         Air Interface
        (MHz)                                  (W/kg)                         (W/kg)                      (Yes/No)

 2400               Wi-Fi 802.11b/g/n           N/A                           0.369                         No




                                                   Page 20 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 14U17814-S3A                                                                         Issue Date: 8/27/2014
FCC ID: 2AB8ZND1

13.     Appendixes
Refer to separated files for the following appendixes.

    13.1.       Photos and Antenna Locations

    13.2.       System Performance Check Plots

    13.3.       Highest SAR Test Plots

    13.4.       Calibration Certificate for E-Field Probe EX3DV4 - SN 3749

    13.5.       Calibration Certificate for D2450V2 - SN 899



                                                 END OF REPORT




                                                   Page 21 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2019-06-22 23:45:03
Document Modified: 2019-06-22 23:45:03

© 2025 FCC.report