RF Exposure Information

FCC ID: 2AB87197D

RF Exposure Info

Download: PDF
FCCID_2611669

Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.:RDG150401003-00B

FCC §15.407(f) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.407(f)and subpart §1.1310, systems operating under the provisions of this
section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy
level in excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                         (B) Limits for General Population/Uncontrolled Exposure

Frequency Range        Electric Field        Magnetic Field          Power Density         Averaging Time
     (MHz)            Strength (V/m)         Strength (A/m)            (mW/cm2)              (minutes)

    0.3–1.34                614                    1.63                  *(100)                   30
    1.34–30                824/f                  2.19/f                *(180/f²)                 30
     30–300                 27.5                  0.073                    0.2                    30
   300–1500                   /                     /                    f/1500                   30
 1500–100,000                 /                     /                      1.0                    30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculated Formulary:

Predication of MPE limit at a given distance
S = PG/4πR² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);
For simultaneously transmit system, the calculated power density should comply with:




FCC Part 15.407                                                                               Page 12 of 177


 Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.:RDG150401003-00B

 Calculated Data:
 MPE evaluation for single transmission:
                                                          Conducted
                                      Antenna Gain                       Evaluation     Power      MPE
Frequency                Frequency                          Power
              Mode                                                        Distance     Density     Limit
  Range                    (MHz)
                                     (dBi)   (numeric)   (dBm)   (mW)       (cm)      (mW/cm2)   (mW/cm2)
  (MHz)
              2.4G-
                           2412       5.0      3.16      17.09   51.17      20         0.032         1.0
             802.11b
              2.4G-
                           2462       5.0      3.16      16.98   49.89      20         0.031         1.0
             802.11g
2412-2462     2.4G-
             802.11n       2462       5.0      3.16      16.82   48.08      20         0.030         1.0
              HT20
              2.4G-
             802.11n       2452       5.0      3.16      16.70   46.77      20         0.029         1.0
              HT40
               5G-
                           5180       5.0      3.16      18.03   63.53      20         0.040         1.0
             802.11a
               5G-
5150-5250    802.11n       5240       5.0      3.16      18.16   65.46      20         0.041         1.0
              HT20
               5G-
             802.11n       5230       5.0      3.16      15.08   32.21      20         0.020         1.0
              HT40
            802.11ac80     5210       5.0      3.16      12.69   18.58      20         0.012         1.0
             802.11a       5745       5.0      3.16      16.92   49.20      20         0.031         1.0
               5G-
             802.11n       5825       5.0      3.16      15.14   32.66      20         0.021         1.0
5725-5850     HT20
               5G-
             802.11n       5755       5.0      3.16      16.44   44.06      20         0.028         1.0
              HT40
            802.11ac80     5775       5.0      3.16      17.30   53.70      20         0.034         1.0

 MPE evaluation for simultaneous transmission:

  2.4 G and 5G can transmit at the same time, MPE evaluation is as below formula:

 PD1/Limit1+PD2/Limit2+……<1, PD (Power Density)

 MPE evaluation= Max MPE of 2.4G + Max MPE of 5G = 0.032/1+0.041/1=0.073<1

 Result: MPE evaluation of single and simultaneous transmission meet the requirement of standard.




 FCC Part 15.407                                                                          Page 13 of 177



Document Created: 2015-05-04 17:49:52
Document Modified: 2015-05-04 17:49:52

© 2024 FCC.report