Test Report

FCC ID: 2AB7X-WISECUBE

Test Report

Download: PDF
FCCID_4081301

                                                                                                                                            2/F., Garment Centre,
                                                                                                                                            576 Castle Peak Road, Kowloon,
                                                                                                                                            Hong Kong.

                                                                                                                                            Telephone:    (852) 2173 8888
                                                                                                                                            Facsimile:    (852) 2785 5487
                                                                                                                                            www.intertek.com




TEST REPORT

Report No.: 18091162HKG‐005

BBPOS International Limited

Application For Certification
(Original Grant)
This report contains the data of 13MHZ RFID portion only

FCC ID: 2AB7X‐WISECUBE

Transceiver




Prepared and Checked by:                                                                            Approved by:
                                                                                                                       Digitally signed
                                                                                                                       by Jess Tang
                                                                                                                       Location:
                                                                                                                       Intertek Testing
                                                                                                                       Services Hong
Signed On File                                                                                                         Kong Ltd.

Kung Wing Cheong, Steven                                                                            Tang Kwan Mo, Jess
Senior Lead Engineer                                                                                Lead Engineer
                                                                                                    Date: November 06, 2018




Intertek’s standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/.
The test report only allows to be revised within the retention period unless further standard or the requirement was noticed.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited
to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or
damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results
in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification
program.
© 2017 Intertek

                                                                                   Page 1 of 18


                                                                  BBPOS International Limited
                                                                  Intertek Report No:
                                                                  18091162HKG‐005




TEST REPORT

GENERAL INFORMATION

Grantee:                    BBPOS International Limited
Grantee Address:            Suite 1903‐04, Tower 2, Nina Tower,
                            8 Yeung Uk Road, Tsuen Wan,
                            N.T., Hong Kong.
Contact Person:             Adrian Kwan
Tel:                        +852 31582585
Fax:                        +852 31582586
e‐mail:                     adrian.kwan@bbpos.com
Manufacturer:               BBPOS International Limited
Manufacturer Address:       Suite 1903‐04, Tower 2, Nina Tower,
                            8 Yeung Uk Road, Tsuen Wan,
                            N.T., Hong Kong.
Brand Name:                 BBPOS
Model:                      WiseCube
Type of EUT:                Transceiver
Description of EUT:         WiseCube
Serial Number:              N/A
FCC ID:                     2AB7X‐WISECUBE
Date of Sample Submitted:   September 27, 2018
Date of Test:               September 27, 2018 to November 02, 2018
Report No.:                 18091162HKG‐005
Report Date:                November 06, 2018
Environmental Conditions:   Temperature: +10 to 40°C
                            Humidity: 10 to 90%




                                     Page 2 of 18


                                                                               BBPOS International Limited
                                                                               Intertek Report No:
                                                                               18091162HKG‐005




TEST REPORT

SUMMARY OF TEST RESULT

 Test Specification                                  Reference                            Results
 Transmitter Field Strength                          15.225                               Pass
 Frequency Stability
 Radiated Emission                                   15.209                               Pass
 Radiated Emission on the Bandedge
 Radiated Emission in Restricted Bands               15.205                               Pass

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2016 Edition


Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
         considered sufficient to comply with the pervisions of this section.
      2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
         within the frequency band designated (mentioned as above) which the EUT operated. The
         effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
         frequency stability over excepted variations in temperature and supply voltage were considered.




                                               Page 3 of 18


                                                                                                          BBPOS International Limited
                                                                                                          Intertek Report No:
                                                                                                          18091162HKG‐005




TEST REPORT
TABLE OF CONTENTS

1.0    GENERAL DESCRIPTION ................................................................................................ 5

       1.1      Product Description .................................................................................................5
       1.2      Related Submittal(s) Grants......................................................................................5
       1.3      Test Methodology ....................................................................................................5
       1.4      Test Facility ..............................................................................................................5

2.0    SYSTEM TEST CONFIGURATION..................................................................................... 6

       2.1      Justification..............................................................................................................6
       2.2      EUT Exercising Software ...........................................................................................6
       2.3      Special Accessories...................................................................................................6
       2.4      Measurement Uncertainty .......................................................................................6
       2.5      Support Equipment List and Description ..................................................................6

3.0    EMISSION RESULTS....................................................................................................... 7

       3.1      Field Strength Calculation.........................................................................................7
       3.2      Radiated Emission Configuration Photograph...........................................................8
       3.3      Radiated Emission Data............................................................................................8
       3.4      Frequency Stability.................................................................................................10

4.0    EQUIPMENT PHOTOGRAPHS ...................................................................................... 11

5.0    PRODUCT LABELLING.................................................................................................. 11

6.0    TECHNICAL SPECIFICATIONS ....................................................................................... 11

7.0    INSTRUCTION MANUAL.............................................................................................. 11

8.0    MISCELLANEOUS INFORMATION ................................................................................ 12

       8.1      Measured Bandwidth.............................................................................................12
       8.2      Discussion of Pulse Desensitization ........................................................................13
       8.3      Calculation of Average Factor.................................................................................13
       8.4      Emissions Test Procedures .....................................................................................14

9.0    CONFIDENTIALITY REQUEST ....................................................................................... 18

10.0   EQUIPMENT LIST........................................................................................................ 18


                                                             Page 4 of 18


                                                                                     BBPOS International Limited
                                                                                     Intertek Report No:
                                                                                     18091162HKG‐005




TEST REPORT

1.0   GENERAL DESCRIPTION

1.1   Product Description

      The Equipment Under Test (EUT) is an 13MHz RFID card reader which can support Bluetooth 2.1
      and 4.2. For the RFID function, it uses to identify the tags. The EUT is powered by 3.7V internal
      battery.

      Antenna Type: Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      This is a single application for certification of a transceiver.


1.3   Test Methodology

      Both AC mains line‐conducted and radiated emission measurements were performed
      according to the procedures in ANSI C63.10 (2013). All radiated measurements were performed
      in an 3m Chamber . Preliminary scans were performed in the 3m Chamber only to
      determine worst case modes. All radiated tests were performed at an antenna to EUT
      distance of 3 meters, unless stated otherwise in the “Justification Section” of this Application.


1.4   Test Facility

      The 3m Chamber and conducted measurement facility used to collect the radiated data is
      located at Workshop No. 3, G/F., World‐Wide Industrial Centre, 43‐47 Shan Mei Street, Fo Tan,
      Sha Tin, N.T., Hong Kong. This test facility and site measurement data have been placed on file
      with the FCC.




                                                  Page 5 of 18


                                                                               BBPOS International Limited
                                                                               Intertek Report No:
                                                                               18091162HKG‐005




TEST REPORT
2.0   SYSTEM TEST CONFIGURATION
2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would normally use it),
      and in the confines as outlined in ANSI C63.10 (2013).

      The device was powered by fully charged 3.7V internal battery.

      For maximizing emissions below 30 MHz, the EUT was rotated through 360°, the centre of the
      loop antenna was placed 1 meter above the ground, and the antenna polarization was changed.
      For maximizing emission at and above 30 MHz, the EUT was rotated through 360°, the antenna
      height was varied from 1 meter to 4 meters above the ground plane, and the antenna polarization
      was changed. This step by step procedure for maximizing emissions led to the data report in
      Exhibit 3.0.

      The rear of unit shall be flushed with the rear of the table. The unit was operated standalone and
      placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion (as a customer
      would normally use it). The EUT was mounted to a plastic stand if necessary and placed on the
      wooden turntable, which enabled the engineer to maximize emissions through its placement in
      the three orthogonal axes.

      All relevant operation modes have been tested, and the worst case data was included in this
      report.


2.2   EUT Exercising Software

      There was no special software to exercise the device. Once the unit is powered up, it transmits
      the RF signal continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.


2.4   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test has been
      considered.


2.5   Support Equipment List and Description

      1. C3 EMV Test card (Supplied by Client)
      2. Mobile phone (Brand: Samsung, Model: SM‐G9287)(Supplied by Client)




                                               Page 6 of 18


                                                                              BBPOS International Limited
                                                                              Intertek Report No:
                                                                              18091162HKG‐005




TEST REPORT

3.0   EMISSION RESULTS

      Data is included of the worst case configuration (the configuration which resulted in the highest
      emission levels). A sample calculation, configuration photographs and data tables of the
      emissions are included.


3.1   Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting
      the Amplifier Gain (if any), Average Factor (optional) from the measured reading. The basic
      equation with a sample calculation is as follows:
      FS = RA + AF + CF ‐ AG ‐ AV
      where FS = Field Strength in dBµV/m
                      RA = Receiver Amplitude (including preamplifier) in dBµV
                      CF = Cable Attenuation Factor in dB
                      AF = Antenna Factor in dB
                      AG = Amplifier Gain in dB
                      AV = Average Factor in dB

      In the following table(s), the reading shown on the data table reflects the preamplifier gain. An
      example for the calculations in the following table is as follows:
      FS = RR + LF
      where          FS = Field Strength in dBµV/m
                     RR = RA ‐ AG ‐ AV in dBµV
                     LF = CF + AF in dB

      Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of 7.4 dB and cable
      factor of 1.6 dB are added. The amplifier gain of 29 dB and average factor of 5 dB are
      subtracted, giving a field strength of 32 dBµV/m. This value in dBµV/m was converted to its
      corresponding level in µV/m.

      RA = 52.0 dBµV/m
      AF = 7.4 dB                          RR = 18.0 dBµV
      CF = 1.6 dB                          LF = 9.0 dB
      AG = 29.0 dB
      AV = 5.0 dB
      FS = RR + LF
      FS = 18 + 9 = 27 dBµV/m

      Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




                                              Page 7 of 18


                                                                               BBPOS International Limited
                                                                               Intertek Report No:
                                                                               18091162HKG‐005




TEST REPORT
3.2   Radiated Emission Configuration Photograph

      The worst case in radiated emission was found at 691.626 MHz

      For electronic filing, the worst case radiated emission configuration photographs are saved with
      filename: radiated photos.pdf.


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the limit and the margin
      of compliance. Numbers with a minus sign are below the limit.

      Judgment: Passed by 7.5 dB




                                              Page 8 of 18


                                                                               BBPOS International Limited
                                                                               Intertek Report No:
                                                                               18091162HKG‐005




TEST REPORT

RADIATED EMISSIONS
Model: WiseCube
Worst‐Case Operating Mode: Transmitting

                                               Table 1
                         Pursuant to FCC Part 15 Section 15.225 Requirement

   Polarization Frequency Reading Pre- Antenna    Net   Distance Calculated  Limit Margin
                  (MHz)   (dBμV) amp Factor      at 3m   Factor   at 30m    at 30m  (dB)
                                  (dB)  (dB)   (dBμV/m)   (-dB)  (dBμV/m) (dBμV/m)
        V         13.560   43.7     0   10.8      54.5    40.0      14.5     84.0  -69.5
        V         27.120   22.8     0    9.5      32.3    40.0      -7.7     29.5  -37.2

                                   Pre- Antenna  Net     Limit
         Polari- Frequency Reading amp Factor   at 3m    at 3m Margin
         zation    (MHz)   (dBμV) (dB)   (dB) (dBμV/m) (dBμV/m) (dB)
           V       40.680    37.3   16   10.0    31.3    40.0    -8.7
           H       67.800    39.7   16    8.0    31.7    40.0    -8.3
           H       94.920    36.0   16   11.0    31.0    43.5   -12.5
           H      122.040    37.8   16   14.0    35.8    43.5    -7.7
           H      135.600    32.8   16   14.0    30.8    43.5   -12.7
           H      149.160    34.8   16   14.0    32.8    43.5   -10.7
           H      162.718    32.5   16   16.0    32.5    43.5   -11.0
           H      176.307    24.4   16   25.0    33.4    43.5   -10.1
           H      230.511    32.1   16   18.0    34.1    46.0   -11.9
           H      257.659    31.0   16   21.0    36.0    46.0   -10.0
           H      284.776    25.2   16   22.0    31.2    46.0   -14.8
           H      311.894    26.1   16   23.0    33.1    46.0   -12.9
           H      393.276    23.3   16   25.0    32.3    46.0   -13.7
           H      691.626    24.5   16   30.0    38.5    46.0    -7.5

NOTES:    1. Peak Detector Data unless otherwise stated.

          2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3‐
             meter distances were measured at 0.3‐meter and an inverse proportional extrapolation
             was performed to compare the signal level to the 3‐meter limit. No other harmonic
             emissions than those reported were detected at a test distance of 0.3‐meter.

          3. Negative sign in the column shows value below limit.

          4. Loop antenna is used for the emissions below 30MHz.

          5. Emission within the restricted band meets the requirement of FCC Part 15 Section 15.205.

          6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.



                                               Page 9 of 18


                                                                                  BBPOS International Limited
                                                                                  Intertek Report No:
                                                                                  18091162HKG‐005




TEST REPORT
3.4    Frequency Stability

                                        FCC Part 15 Section 15.225

                                               Data Table
                                Frequency Deviation with Voltage Variation


      Operating frequency        13.560840MHz
Test Voltage      Temperature
                                   Measured frequency (MHz)       Frequency error (%)              Limit (%)
     (V)              (C)
     3.7             + 50                  13.560686                   -0.00072                      ±0.01
     3.7             + 40                  13.560708                   -0.00056                      ±0.01
     3.7             + 30                  13.560716                   -0.00050                      ±0.01
     3.7             + 20                  13.560784                       0                         ±0.01
     3.7             + 10                  13.560810                    0.00019                      ±0.01
     3.7                0                  13.560816                    0.00024                      ±0.01
     3.7              - 10                 13.560822                    0.00028                      ±0.01
     3.7              - 20                 13.560832                    0.00035                      ±0.01



      Nominal frequency
       Temperature (°C)                       Frequency         Frequency          Limite
         Humidity (%)            Voltage        (MHz)           error (ppm)        (ppm)            Result
          20°C 50%                 3.7        13.560784              0              100              Pass
          20°C 50%                 3.4        13.560790            0.442            100              Pass
          20°C 50%                 3.1        13.560796            0.885            100              Pass



The device is deemed to comply with the requirement of FCC15.225(e).




                                                Page 10 of 18


                                                                               BBPOS International Limited
                                                                               Intertek Report No:
                                                                               18091162HKG‐005




TEST REPORT

4.0   EQUIPMENT PHOTOGRAPHS

      For electronic filing, the photographs are saved with filename: external photos.pdf and internal
      photos.pdf.


5.0   PRODUCT LABELLING

      For electronics filing, the FCC ID label artwork and the label location are saved with filename:
      label.pdf.


6.0   TECHNICAL SPECIFICATIONS

      For electronic filing, the block diagram and schematic of the tested EUT are saved with filename:
      block.pdf and circuit.pdf respectively.


7.0   INSTRUCTION MANUAL

      For electronic filing, a preliminary copy of the Instruction Manual is saved with filename:
      manual.pdf.

      This manual will be provided to the end‐user with each unit sold/leased in the United States.




                                              Page 11 of 18


                                                                             BBPOS International Limited
                                                                             Intertek Report No:
                                                                             18091162HKG‐005




TEST REPORT

8.0   MISCELLANEOUS INFORMATION

      The miscellaneous information includes details of the test procedure and measured bandwidth
      such as pulse desensitization and averaging factor (calculation and timing diagram).


8.1   Measured Bandwidth

      The plot saved in bw.pdf which shows the fundamental emission is confined in the specified band.
      The emission of the fundamental is 54.5 dBµV/m and it is below the limit of 50.5 dBµV/m in the
      range of (13.410‐13.553MHz) and (13.567‐13.710MHz) and the limit of 40.5 dBµV/m in the
      frequency range of (13.110‐14.410MHz) and (13.710‐14.010MHz). In the frequency range from
      13.110‐14.010MHz, we can not find any emission higher than the fundamental emission.
      Therefore they meet the requirement of Section 15.225(a), (b), (c), & (d).




                                             Page 12 of 18


                                                                                BBPOS International Limited
                                                                                Intertek Report No:
                                                                                18091162HKG‐005




TEST REPORT
8.2   Discussion of Pulse Desensitization

      Pulse desensitivity is not applicable for this device. Since the transmitter transmits the RF signal
      continuously.


8.3   Calculation of Average Factor

      The average factor is not applicable for this device as the transmitted signal is a continuously
      signal.




                                              Page 13 of 18


                                                                               BBPOS International Limited
                                                                               Intertek Report No:
                                                                               18091162HKG‐005




TEST REPORT
8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing Services Hong Kong
      Ltd. in the measurements of transmitter operating under the Part 15, Subpart C rules.

      The transmitting equipment under test (EUT) is placed on a wooden turntable which is four feet in
      diameter and approximately 0.8m in height above the ground plane for emission measurement at
      or below 1GHz and 1.5m in height above the ground plane for emission measurement above
      1GHz. During the radiated emissions test, the turntable is rotated and any cables leaving the EUT
      are manipulated to find the configuration resulting in maximum emissions. The EUT is adjusted
      through all three orthogonal axis to obtain maximum emission levels. The antenna height and
      polarization are also varied during the testing to search for maximum signal levels. The height of
      the antenna is varied from one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when required, are
      taken by measuring the duty cycle of the equipment under test and subtracting the corresponding
      amount in dB from the measured peak readings. A detailed description for the calculation of the
      average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal generated in the device
      which is greater than 9 kHz to the tenth harmonic of the highest fundamental frequency or 40
      GHz, whichever is lower. For line conducted emissions, the range scanned is 150 kHz to 30 MHz.




                                             Page 14 of 18


                                                                               BBPOS International Limited
                                                                               Intertek Report No:
                                                                               18091162HKG‐005




TEST REPORT
8.4   Emissions Test Procedures (cont’d)

      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the fundamental
      emission field strength is recorded. If battery powered, a new, fully charged battery is used.

      Conducted measurements were made as described in ANSI C63.10 (2013).

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz or greater when
      frequency is below 1000 MHz. Where pulsed transmissions of short enough pulse duration
      warrant, a greater bandwidth is selected according to the recommendations of Hewlett Packard
      Application Note 150‐2. A discussion of whether pulse desensitivity is applicable to this unit is
      included in this report (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 3 MHz is
      used.

      Transmitter measurements are normally conducted at a measurement distance of three
      meters. However, to assure low enough noise floor in the forbidden bands and above 1 GHz,
      signals are acquired at a distance of one meter or less. All measurements are extrapolated to three
      meters using inverse scaling, unless otherwise reported. Measurements taken at a closer
      distance are so marked.




                                              Page 15 of 18


                                                                                BBPOS International Limited
                                                                                Intertek Report No:
                                                                                18091162HKG‐005




TEST REPORT
8.4.1   Radiated Emission Test Setup (For 27M and below 27M)

        The figure below shows the test setup, which is utilized to make these measurements.



                                                                    Antenna
                                                                    Tower


                                          3m                             Receiver
                            E
                                                                         Antenna
                            U
                            T



                                                   1.0m
             0.8m

                    Ground Plane
         3m Chamber                                       □

                                                                   RF Test
                                                                   Receiver


                             Test setup of radiated emissions up to 30MHz



                                                                    Antenna
                                                    1.0~4.0m        Tower


                                          3m                             Receiver
                                                                         Antenna
                            E

                            U



             0.8m

                    Ground Plane
         3m Chamber                                       □

                                                                   RF Test
                                                                   Receiver



                                Test setup of radiated emissions above 1GHz




                                                Page 16 of 18


                                                                               BBPOS International Limited
                                                                               Intertek Report No:
                                                                               18091162HKG‐005




TEST REPORT
8.4.2   Conducted Emission Test Procedures

        For tabletop equipment, the EUT along with its peripherals were placed on a 1.0m(W)1.5m(L)
        and 0.8m in height wooden table. For floor‐standing equipment, the EUT and all cables were
        insulated, if required, from the ground plane by up to 12 mm of insulating material. The EUT was
        adjusted to maintain a 0.4 meter space from a vertical reference plane. The EUT was connected
        to power mains through a line impedance stabilization network (LISN), which provided 50 ohm
        coupling impedance for measuring instrument and the chassis ground was bounded to the
        horizontal ground plane of shielded room. The excess power cable between the EUT and the
        LISN was bundled.

        All connecting cables of EUT and peripherals were moved to find the maximum emission.


8.4.3   Conducted Emission Test Setup

         AC Power
                        LISN 1               EUT               Peripherals           LISN 2




                         EMI
                       Receiver                                                    AC Power




                                               Page 17 of 18


                                                                              BBPOS International Limited
                                                                              Intertek Report No:
                                                                              18091162HKG‐005




TEST REPORT
9.0    CONFIDENTIALITY REQUEST
       For electronic filing, a preliminary copy of the confidentiality request is saved with filename:
       request.pdf.
10.0 EQUIPMENT LIST
1) Radiated Emissions Test
Equipment                 EMI Test Receiver              Spectrum Analyzer        Biconical Antenna
Registration No.              EW‐3156                        EW‐3281                  EW‐0571
Manufacturer               ROHDESCHWARZ                   ROHDESCHWARZ                 EMCO
Model No.                      ESR26                           FSV40                   3104C
Calibration Date         November 10, 2017                January 02, 2018        February 27, 2018
Calibration Due Date     November 10, 2018                January 02, 2019         August 27, 2019

Equipment                  Log Periodic Antenna        Double Ridged Guide      Log Periodic Antenna
                                                            Antenna
Registration No.                EW‐1042                     EW‐1133                    EW‐0447
Manufacturer                     EMCO                         EMCO                       EMCO
Model No.                         3148                         3115                       3146
Calibration Date              June 19, 2017               May 24, 2017             January 17, 2018
Calibration Due Date        December 19, 2018           November 24, 2018            July 17, 2019

Equipment                   BiConiLog Antenna          Double Ridged Guide        Biconical Antenna
                                                            Antenna
Registration No.                EW‐3061                     EW‐0194                   EW‐2512
Manufacturer                     EMCO                         EMCO                     EMCO
Model No.                        3142E                         3115                    3104C
Calibration Date            November 02, 2017            March 14, 2018            August 06, 2018
Calibration Due Date        November 02, 2018          September 14, 2019         February 06, 2020

Equipment                    Active Loop H‐field          RF CABLE (9kHz           RF Pre‐amplifier
                          Antenna (9kHz to 30MHz)          to 1000 MHz)            (9kHz to 40GHz)
Registration No.                 EW‐2313                     EW‐3170                   EW‐3006
Manufacturer                  ELETROMETRIC                 UNBRANDED                SCHWARZBECK
Model No.                        EM‐6876                 9kHz to 1000MHz              BBV 9718
Calibration Date              March 08, 2018               May 11, 2018              April 26, 2018
Calibration Due Date        September 08, 2019             May 11, 2019              April 26, 2019

2)      Bandedge Measurement and Frequency Stability Measurement
Equipment                Spectrum Analyzer           Temperature &
                                                  Humidity Chamber
Registration No.              EW‐3281                   EW‐2134
Manufacturer              ROHDESCHWARZ                GIANT FORCE
Model No.                       FSV40              GTH‐750‐40‐CP‐SD
Calibration Date           January 02, 2018       September 04, 2018
Calibration Due Date       January 02, 2019       September 04, 2019

                                        END OF TEST REPORT