Test Report

FCC ID: 2AB75-WM-783

Test Report

Download: PDF
FCCID_4188536

                      CTC Laboratories, Inc.
1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
Tel: +86-755- 27521059 Fax: +86-755- 27521011 Http://www.sz-ctc.com.cn


                                            TEST REPORT
 Report No. ····························:     GTI20190194F

 FCC ID··································:    2AB75-WM-783

 Applicant································:   Wintop Electronics Co., Ltd

 Address·································:    Unit 04 7/F, Bright Way Tower 33, Mong Kok RD, KL, Hong Kong

 Manufacturer··························:      Shenzhen Wintop Electronics Co.,Ltd
                                              No.46 Xinhe Road Shangmugu Pinghu Town Longgang District
 Address·································:
                                              Shenzhen China
 Product Name························:        WIRELESS MOUSE

 Trade Mark·····························:     N.A.

 Model/Type reference···············:         WM-783

 Listed Model(s) ·······················:     N.A.

 Standard·······························:     Operation within the bands 902-928 MHz, 2400-2483.5 MHz,
                                              5725-5875 MHz, and 24.0-24.25 GHz.

 Date of receipt of test sample…:             2019.01.31

 Date of testing…………………..:                    2019.01.31 ~ 2019.02.19

 Date of issue…………………....:                    2019.02.20

 Result……………………………:                           PASS

 Compiled by:
 (Printed name+signature)                     Torny Fang

 Supervised by:
 ( Printed name+signature)                    Cary Luo

                                                                                               $英文检
 Approved by:
 ( Printed name+signature)                    Walter Chen                                                     测
 Testing Laboratory Name :                    CTC Laboratories, Inc.

 Address      :                               1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park,
                                              Shenzhen, Guangdong, China
 This test report may be duplicated completely for legal use with the approval of the applicant. It should not
 be reproduced except in full, without the written approval of our laboratory. The client should not use it to
 claim product endorsement by CTC. The test results in the report only apply to the tested sample. The
 test report shall be invalid without all the signatures of testing engineers, reviewer and approver.
 Any objections must be raised to CTC within 15 days since the date when the report is received. It will not
 be taken into consideration beyond this limit. The test report merely correspond to the test sample.


                                                                                Page 2 of 30                                          Report No.: GTI20190194F



                                                                       Table of Contents                                                                                      Page
1.     TEST SUMMARY ....................................................................................................................................................... 3
     1.1.     TEST STANDARDS.......................................................................................................................................................... 3
     1.2.     REPORT VERSION .......................................................................................................................................................... 3
     1.3.     TEST DESCRIPTION........................................................................................................................................................ 4
     1.4.     TEST FACILITY .............................................................................................................................................................. 5
     1.5.     MEASUREMENT UNCERTAINTY ........................................................................................................................................ 6
     1.6.     ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 7
2.     GENERAL INFORMATION .......................................................................................................................................... 8
     2.1.     CLIENT INFORMATION ................................................................................................................................................... 8
     2.2.     GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 8
3.     DESCRIPTION OF TEST MODES.................................................................................................................................. 9
4.     MEASUREMENT INSTRUMENTS LIST ....................................................................................................................... 10
5.     TEST ITEM AND RESULTS ........................................................................................................................................ 12
     5.1.     AC POWER LINE CONDUCTED EMISSIONS ....................................................................................................................... 12
     5.2.     20 DB OCCUPIED BANDWIDTH ..................................................................................................................................... 14
     5.3.     RADIATED FIELD STRENGTH OF THE FUNDAMENTAL SIGNAL .................................................................................................. 17
     5.4.     RADIATED SPURIOUS EMISSIONS AND BANDEDGE EMISSION ............................................................................................... 19
     5.5.     ANTENNA REQUIREMENT ............................................................................................................................................. 28
6.     EUT TEST PHOTOS .................................................................................................................................................. 29
7.     PHOTOGRAPHS OF EUT CONSTRUCTIONAL ............................................................................................................ 30




                                                                               CTC Laboratories, Inc
                               1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                                    Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                                 For anti-fake verification, please visit the official website of Certification and
                                                                 Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                       Page 3 of 30                         Report No.: GTI20190194F



 1. TEST SUMMARY
 1.1. Test Standards
The tests were performed according to following standards:

FCC Rules Part 15.249: Operation within the bands 902-928 MHz, 2400-2483.5 MHz, 5725-5875
MHz, and 24.0-24.25 GHz.
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices.

 1.2. Report version
     Version No.                      Date of issue                                            Description
          00                           2019.02.20                                                Original




                                                        CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                        Page 4 of 30                         Report No.: GTI20190194F




 1.3. Test Description
               Test Item                                 Section in CFR 47                         Result           Test Engineer
AC Power Line Conducted Emissions                                 15.207                             N/A                    N/A
      20dB Occupied Bandwidth                               15.215/15.249                          PASS                 Young He
  Field strength of the Fundamental
                                                               15.249(a)                           PASS                 Young He
                signal
         Spurious Emissions                               15.209/15.249(a)                         PASS                 Young He
        Band edge Emissions                               15.205/15.249(d)                         PASS                 Young He
         Antenna requirement                                      15.203                           PASS                 Young He

Note: The measurement uncertainty is not included in the test result.

     This device is only powered battery ,no need for part 15.207.




                                                         CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                         Page 5 of 30                         Report No.: GTI20190194F




 1.4. Test Facility
Address of the report laboratory

CTC Laboratories, Inc.

Add: 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China

Laboratory accreditation

The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L5365
CTC Laboratories, Inc. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No.: 4340.01
CTC Laboratories, Inc. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.


IC Registration No.: 9783A
The 3m alternate test site of CTC Laboratories, Inc. EMC Laboratory has been registered by Certification and
Engineer Bureau of Industry Canada for the performance of with Registration NO.: 9783A on Jan, 2016.


FCC-Registration No.:951311
CTC Laboratories, Inc. EMC Laboratory has been registered and fully described in a report filed with the (FCC)
Federal Communications Commission. The acceptance letter from the FCC is maintained in our files.
RegistrationCN1208, Sep 07, 2017




                                                          CTC Laboratories, Inc
                     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                         Page 6 of 30                         Report No.: GTI20190194F




  1.5. Measurement Uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to TR-100028-01” Electromagnetic compatibility and
Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part
1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the
measurement of mobile radio equipment characteristics; Part 2 “ and is documented in the Shenzhen General
Testing & Inspection Technology Co., Ltd. quality system acc. to DIN EN ISO/IEC 17025. Furthermore,
component and process variability of devices similar to that tested may result in additional deviation. The
manufacturer has the sole responsibility of continued compliance of the device.

Below is the best measurement capability for Shenzhen General Testing & Inspection Technology Co., Ltd.


                       Test Items                                           Measurement Uncertainty                           Notes
Transmitter power conducted                                                              0.42 dB                                (1)
Transmitter power Radiated                                                               2.14 dB                                (1)
Conducted spurious emissions 9kHz~40GHz                                                  1.60 dB                                (1)
Radiated spurious emissions 9kHz~40GHz                                                   2.20 dB                                (1)
Conducted Emissions 9kHz~30MHz                                                           3.20 dB                                (1)
Radiated Emissions 30~1000MHz                                                            4.70 dB                                (1)
Radiated Emissions 1~18GHz                                                               5.00 dB                                (1)
Radiated Emissions 18~40GHz                                                              5.54 dB                                (1)
Occupied Bandwidth                                                                       ---------                              (1)
Note (1): This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.




                                                          CTC Laboratories, Inc
                     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                         Page 7 of 30                         Report No.: GTI20190194F




 1.6. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                                        15~35°C
Relative Humidity:                                                  30~60 %
Air Pressure:                                                       950~1050mba




                                                          CTC Laboratories, Inc
                     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                      Page 8 of 30                         Report No.: GTI20190194F



2. GENERAL INFORMATION
2.1. Client Information
Applicant:                               Wintop Electronics Co., Ltd

Address:                                 Unit 04 7/F, Bright Way Tower 33, Mong Kok RD, KL, Hong Kong

Manufacturer:                            Shenzhen Wintop Electronics Co.,Ltd

Address:                                 No.46 Xinhe Road Shangmugu Pinghu Town Longgang District
                                         Shenzhen China
Factory:                                 Shenzhen Wintop Electronics Co.,Ltd

Address:                                 No.46 Xinhe Road Shangmugu Pinghu Town Longgang District
                                         Shenzhen China

2.2. General Description of EUT
Product Name:                      WIRELESS MOUSE
Model/Type reference:              WM-783
Adding Model(s):                   /
Model difference:                  /
Power supply:                      Battery: DC 3.0V
Hardware version:                  V1.0
Software version:                  V1.0
ANT+:
Supported type:                    ANT+
Modulation:                        GFSK
Operation frequency:               2408MHz.2440MHz.2474MHz
Antenna type:                      PCB Antenna
Antenna gain:                      0dBi




                                                       CTC Laboratories, Inc
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                       Page 9 of 30                         Report No.: GTI20190194F




 3. Description of Test Modes
Peripherals Devices:
                                         OUTSIDE SUPPORT EQUIPMENT
   No.   Equipment          Model          Serial No. Manufacture Trade name                                      Remark
                                                                                                                   N.A
                                                                                                                   N.A
                                                                                                                   N.A

Note: All the above equipment /cable were placed in worse case position to maximize emission signals during
emission test.

Operation Frequency
The Applicant provides communication tools software to control the EUT for staying in continuous
transmitting (Duty Cycle more than 98%) mode for testing.

ANT+
                        Channel                                                         Frequency (MHz)
                           CHL                                                               2408
                           CHM                                                               2440
                           CHH                                                               2474


TEST MODE:

  For RF test items
  The engineering test program was provided and enabled to make EUT continuous transmit.
  For AC power line conducted emissions:
  The EUT was set to connect with large package sizes transmission.




                                                        CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                       Page 10 of 30                          Report No.: GTI20190194F



 4. Measurement Instruments List
Tonscend JS0806-2 Test system
                                                                                                   Calibrated
Item   Test Equipment         Manufacturer            Model No.            Serial No.                                  Calibrated until
                                                                                                     Date
         Spectrum                Rohde &
 1                                                      FSU26                100105             Jan. 07, 2017            Dec. 28 2019
         Analyzer                Schwarz
         Spectrum                Rohde &
 2                                                    FUV40-N                101331             Jan. 07, 2017            Dec. 28 2019
         Analyzer                Schwarz
        MXG Vector
 3        Signal                  Agilent              N5182A            MY47420864             Jan. 07, 2017            Dec. 28 2019
         Generator
          Signal
 4                                Agilent              E8257D            MY46521908             Jan. 07, 2017            Dec. 28 2019
         Generator
 5      Power Sensor              Agilent             U2021XA             MY5365004             Jan. 07, 2017            Dec. 28 2019
 6      Power Sensor              Agilent             U2021XA             MY5365006             Jan. 07, 2017            Dec. 28 2019
        Simultaneous
 7                                Agilent              U2531A            TW54493510             Jan. 07, 2017            Dec. 28 2019
       Sampling DAQ
           Climate
 8                                 TABAI                PR-4G              A8708055             Jan. 07, 2017            Dec. 28 2019
          Chamber
       Wideband Radio
                                 Rohde &
 9     Communication                                  CMW500                 116410             Jan. 06, 2018            Dec. 28 2019
                                 Schwarz
            Tester
           Climate
 10                               ESPEC                MT3065                     /              Jan. 04,2018            Dec. 28 2019
          Chamber
        300328 v2.1.1
 11                           TONSCEND                    v2.6                    /                      /                        /
         test system

Item     Test Equipment               Manufacturer                 Model No.                 Serial No.               Calibrated until

  1     EMI Test Receiver          Rohde & Schwarz                    ESCI                     100658                  Dec. 28 2019

  2       High pass filter             micro-tranics              HPM50111                       142                   Dec. 28 2019

  3     Log-Bicon Antenna             Schwarzbeck                 CBL6141A                      4180                   Dec. 28 2019
          Ultra-Broadband
  4                                     ShwarzBeck                BBHA9170                       25841                 Dec. 28 2019
              Antenna
  5        Loop Antenna                    LAPLAC                    RF300                        9138                 Dec. 28 2019

  6     Spectrum Analyzer          Rohde & Schwarz                   FSU26                     100105                  Dec. 28 2019

  7       Horn Antenna                Schwarzbeck                BBHA 9120D                      647                   Dec. 28 2019

  8       Pre-Amplifier                      HP                      8447D                 1937A03050                  Dec. 28 2019

  9       Pre-Amplifier                     EMCI                 EMC051835                     980075                  Dec. 28 2019

 10       Antenna Mast                       UC                     UC3000                       N/A                          N/A

 11         Turn Table                       UC                     UC3000                       N/A                          N/A

 12     Cable Below 1GHz              Schwarzbeck                  AK9515E                      33155                  Dec. 28 2019

 13     Cable Above 1GHz               Hubersuhner             SUCOFLEX102                    DA1580                   Dec. 28 2019

 14           Splitter                  Mini-Circuit                ZAPD-4                     400059                  Dec. 28 2019
          RF Connection
 15                                HUBER+SUHNER                     RE-7-FL                      N/A                   Dec. 28 2019
              Cable
                                                        CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                        Page 11 of 30                          Report No.: GTI20190194F


           RF Connection                Chengdu
 16                                                                      ---                       ---                  Dec. 28 2019
               Cable                  E-Microwave
                                       Compliance
 17        High pass filter                                           BSU-6                      34202                  Dec. 28 2019
                                    Direction systems
                                        Chengdu                  EMCAXX-10R
 18          Attenuator                                                                            ---                  Dec. 28 2019
                                      E-Microwave                   NZ-3
            High and low
 19                                  ESPEC                 MT3065           12114019           Dec. 28 2019
          temperature box
Note:1. The Cal. Interval was one year.
     2. The cable loss has calculated in test result which connection between each test instruments.




                                                         CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                          Page 12 of 30                          Report No.: GTI20190194F



 5. TEST ITEM AND RESULTS
 5.1. AC Power Line Conducted Emissions
Limit

                                                 Conducted Emission Test Limit

                                                                            Maximum RF Line Voltage (dBµV)
                         Frequency
                                                                     Quasi-peak Level             Average Level
                      150kHz~500kHz                                     66 ~ 56 *                    56 ~ 46 *
                       500kHz~5MHz                                          56                          46
                       5MHz~30MHz                                           60                          50
        Notes:
        (1) *Decreasing linearly with logarithm of the frequency.
        (2) The lower limit shall apply at the transition frequencies.
        (3) The limit decrease in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.


Test Configuration




Test Procedure

1.      The EUT was setup according to ANSI C63.10:2013 requirements.
2.      The EUT was placed on a platform of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting
        ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces of
        EUT were at least 80 cm from any other grounded conducting surface.
3.      The EUT and simulators are connected to the main power through a line impedances stabilization network
        (LISN). The LISN provides a 50ohm /50uH coupling impedance for the measuring equipment.
         The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
         diagram of the test setup and photographs)
4.      Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor, was
        individually connected through a LISN to the input power source.
5.      The excess length of the power cord between the EUT and the LISN receptacle were folded back and forth
        at the center of the lead to form a bundle not exceeding 40 cm in length.
6.      Conducted Emissions were investigated over the frequency range from 0.15MHz to 30MHz using a receiver
        bandwidth of 9 kHz.
7.      During the above scans, the emissions were maximized by cable manipulation.



                                                           CTC Laboratories, Inc
                      1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                           Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                        For anti-fake verification, please visit the official website of Certification and
                                                        Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                        Page 13 of 30                          Report No.: GTI20190194F



Test Mode:

Please refer to the clause 3

Test Results


For the mouse, battery powered, no testing required.




                                                         CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                         Page 14 of 30                          Report No.: GTI20190194F




 5.2. 20 dB Occupied Bandwidth
Limit

Operation frequency range 2400MHz~2483.5MHz.

TEST CONFIGURATION




TEST PROCEDURE

1.   The transmitter output was connected to the spectrum analyzer through an attenuator, the path loss was
     compensated to the results for each measurement.

2.   Set to the maximum power setting and enable the EUT transmit continuously

3.   Use the following spectrum analyzer settings:

     Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel

     RBW ≥ 1% of the 20 dB bandwidth, VBW ≥ RBW

     Sweep = auto, Detector function = peak, Trace = max hold

4.   Measure and record the results in the test report.


TEST MODE:

Please refer to the clause 3

TEST RESULTS

                                                                                             99%
                                                         20dB Bandwidth
              Type               Channel                                                  Bandwidth                Result
                                                             (MHz)
                                                                                            (MHz)
             GFSK                    CHL                         2.2865                      2.1852                  Pass
             GFSK                    CHM                         2.2793                      2.1780                  Pass
             GFSK                    CHH                         2.2793                      2.1708                  Pass




                                                          CTC Laboratories, Inc
                     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                           Page 15 of 30                         Report No.: GTI20190194F




CHL




                Date: 30.JAN.2019   15:00:03




CHM




                Date: 30.JAN.2019   15:02:18




                                               CTC Laboratories, Inc
      1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
           Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                        For anti-fake verification, please visit the official website of Certification and
                                        Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                           Page 16 of 30                         Report No.: GTI20190194F




CHH




                 Date: 30.JAN.2019   15:03:56




                                                CTC Laboratories, Inc
      1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
           Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                        For anti-fake verification, please visit the official website of Certification and
                                        Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                        Page 17 of 30                          Report No.: GTI20190194F




 5.3. Radiated field strength of the fundamental signal
LIMIT

                                             Field strength of fundamental                      Field strength of harmonics
     Fundamental frequency
                                                    (millivolts/meter)                               (microvolts/meter)
          902-928 MHz                              50 (94dBuV/m @3m)                                500 (54dBuV/m @3m)
        2400-2483.5 MHz                            50 (94dBuV/m @3m)                                500 (54dBuV/m @3m)
         5725-5875 MHz                             50 (94dBuV/m @3m)                                500 (54dBuV/m @3m)
         24.0-24.25 GHz                          250 (108dBuV/m @3m)                               2500 (68dBuV/m @3m)
Frequencies above 1000 MHz, the field strength limits are based on average limits


TEST CONFIGURATION




TEST PROCEDURE

1.   The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.   The EUT is placed on a turn table which is 1.5 meter above ground. The turn table is rotated 360 degrees to
     determine the position of the maximum emission level.
3.   The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4.   The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis repeated
     for both horizontal and vertical polarization of the antenna. In order to find the maximum emission, all of the
     interface cables were manipulated according to ANSI C63.10:2013 on radiated measurement.
5.   The receiver set as follow:
     RBW=1MHz, VBW=3MHz Peak detector for Peak value.
     RBW=1MHz, VBW=3MHz RMS detector for Average value.
TEST MODE:

Please refer to the clause 3



                                                         CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                       Page 18 of 30                          Report No.: GTI20190194F



TEST RESULTS

                Read       Correction                                               Limit        Margin
Frequency                                                                                                                           Test
                Level         Factor               Level (dBuV/m)                   Line                       Polarization
 (MHz)                                                                                             (dB)                             value
               (dBuV)        (dB/m)                                             (dBuV/m)
  2408          62.36          -6.28                     55.23                      114           -58.77          Vertical          Peak
  2408          61.54          -6.28                     54.37                      114           -59.63        Horizontal          Peak
  2440          63.14          -5.63                     58.69                      114           -55.31          Vertical          Peak
  2440          62.58          -5.63                     57.34                      114           -56.66        Horizontal          Peak
  2474          63.39          -6.23                     58.26                      114           -55.74          Vertical          Peak
  2474          62.22          -6.23                     56.33                      114           -57.67        Horizontal          Peak

 Remark:
         1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
         2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
         3.   Margin value = Limit value- Emission level.
         4.   -- Mean the PK detector measured value is below average limit.
         5.   The other emission levels were very low against the limit.




                                                        CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                      Page 19 of 30                          Report No.: GTI20190194F




 5.4. Radiated Spurious Emissions and Bandedge Emission
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.209
            Frequency                                     Limit (dBuV/m @3m)                                      Value

          30MHz~88MHz                                                40.00                                    Quasi-peak

          88MHz~216MHz                                               43.50                                    Quasi-peak

         216MHz~960MHz                                               46.00                                    Quasi-peak

          960MHz~1GHz                                                54.00                                    Quasi-peak

                                                                     54.00                                      Average
           Above 1GHz
                                                                     74.00                                        Peak

TEST CONFIGURATION

   9 kHz ~ 30 MHz




   30 MHz ~ 1 GHz




   Above 1 GHz




                                                       CTC Laboratories, Inc
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                          Page 20 of 30                          Report No.: GTI20190194F




TEST PROCEDURE

1.   The EUT was setup and tested according to ANSI C63.10:2013 requirements.

2.   The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above 1
     GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level.

3.   The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable height
     antenna tower.
4.   For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower
     (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and
     a high pass filter are used for the test in order to get better signal level to comply with the guidelines.
5.   Set to the maximum power setting and enable the EUT transmit continuously.
6.   Use the following spectrum analyzer settings

     (1) Span shall wide enough to fully capture the emission being measured;
     (2) Below 1 GHz:
         RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold;
         If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit,
         the peak emission level will be reported. Otherwise, the emission measurement will be repeated using
         the quasi-peak detector and reported.
     (3) From 1 GHz to 10th harmonic:
         RBW=1MHz, VBW=3MHz Peak detector for Peak value.
         RBW=1MHz, VBW=3MHz RMS detector for Average value.


TEST MODE:

Please refer to the clause 3

TEST RESULTS

Note:
1)   Above 1GHz Final       Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2)   The emission levels of other frequencies are very lower than the limit and not show in test report.



                                                           CTC Laboratories, Inc
                      1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                           Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                        For anti-fake verification, please visit the official website of Certification and
                                                        Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                     Page 21 of 30                          Report No.: GTI20190194F



Radiated Spurious Emissions

   9 kHz ~ 30 MHz
    The EUT was pre-scanned the frequency band (9 kHz ~ 30 MHz), found the radiated level lower
    than the limit, so don’t show on the report.
   30 MHz ~ 1 GHz

Polarization:                                                   Vertical




                                                      CTC Laboratories, Inc
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                       Page 22 of 30                          Report No.: GTI20190194F



Polarization:                                                     Horizontal




 Remark:
         1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
         2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
         3.   Margin value = Limit value- Emission level.
         4.   -- Mean the PK detector measured value is below average limit.
         5.   The other emission levels were very low against the limit.




                                                        CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                          Page 23 of 30                          Report No.: GTI20190194F



    Above 1 GHz

                   Read       Correction                                               Limit        Margin
Frequency                                                                                                                              Test
                   Level         Factor               Level (dBuV/m)                   Line                       Polarization
    (MHz)                                                                                             (dB)                             value
                  (dBuV)        (dB/m)                                             (dBuV/m)
    4816           46.12          -4.29                     41.83                       74           -32.17          Vertical          Peak
    7224           43.21          1.05                      44.26                       74           -29.74          Vertical          Peak
    4816           44.58          -4.29                     40.29                       74           -33.71        Horizontal          Peak
    7224           41.69          1.05                      42.74                       74           -31.26        Horizontal          Peak


                   Read       Correction                                               Limit        Margin
Frequency                                                                                                                              Test
                   Level         Factor               Level (dBuV/m)                   Line                       Polarization
    (MHz)                                                                                             (dB)                             value
                  (dBuV)        (dB/m)                                             (dBuV/m)
    4880           45.35          -4.29                     41.06                       74           -32.94          Vertical          Peak
    7320           42.79          1.05                      43.84                       74           -30.16          Vertical          Peak
    4880           43.31          -4.29                     39.02                       74           -34.98        Horizontal          Peak
    7320           42.81          1.05                      43.86                       74           -30.14        Horizontal          Peak


                   Read       Correction                                               Limit        Margin
Frequency                                                                                                                              Test
                   Level         Factor               Level (dBuV/m)                   Line                       Polarization
    (MHz)                                                                                             (dB)                             value
                  (dBuV)        (dB/m)                                             (dBuV/m)
    4948           47.12          -4.29                     42.83                       74           -31.17          Vertical          Peak
    7422           44.39          1.05                      45.44                       74           -28.56          Vertical          Peak
    4948           45.89          -4.29                      41.6                       74            -32.4        Horizontal          Peak
    7422           44.31          1.05                      45.36                       74           -28.64        Horizontal          Peak

 Remark:
            1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
            2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
            3.   Margin value = Limit value- Emission level.
            4.   -- Mean the PK detector measured value is below average limit.
            5.   The other emission levels were very low against the limit.




                                                           CTC Laboratories, Inc
                      1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                           Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                        For anti-fake verification, please visit the official website of Certification and
                                                        Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                      Page 24 of 30                          Report No.: GTI20190194F



Bandedge Emission

      Ant. Pol.                Horizontal
      Test Mode:               2408MHz




                                                       CTC Laboratories, Inc
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                Page 25 of 30                          Report No.: GTI20190194F




Ant. Pol.                Vertical
Test Mode:               2408MHz




                                                 CTC Laboratories, Inc
            1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                 Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                              For anti-fake verification, please visit the official website of Certification and
                                              Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                Page 26 of 30                          Report No.: GTI20190194F



Ant. Pol.                Horizontal
Test Mode:               2474MHz




                                                 CTC Laboratories, Inc
            1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                 Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                              For anti-fake verification, please visit the official website of Certification and
                                              Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                     Page 27 of 30                          Report No.: GTI20190194F




     Ant. Pol.                Vertical
     Test Mode:               2474MHz




Remark:
     1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
     2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
     3.   Margin value = Limit value- Emission level.
     4.   -- Mean the PK detector measured value is below average limit.
     5.   The other emission levels were very low against the limit.




                                                      CTC Laboratories, Inc
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                        Page 28 of 30                          Report No.: GTI20190194F




 5.5. Antenna requirement
Requirement

FCC CFR Title 47 Part 15 Subpart C Section 15.203:
 An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
 party shall be used with the device.        The use of a permanently attached antenna or of anantenna that uses a
 unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can
 be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
FCC CFR Title 47 Part 15 Subpart C Section 15.247(c) (1)(i):
 (i) Systems operating in the 2400~2483.5 MHz band that is used exclusively for fixed. Point-to-point operations
 may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted
 output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna
 exceeds 6dBi.

Test Result

The EUT's antenna is soldered to the PCB. The gain of the antenna is 0dBi. meet the standards.
                                                                   asdass ada




Antenna




                                                         CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                     Page 29 of 30                          Report No.: GTI20190194F



 6. EUT TEST PHOTOS
Reference to the document No.: Test Photo




                                                      CTC Laboratories, Inc
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                     Page 30 of 30                          Report No.: GTI20190194F



 7. PHOTOGRAPHS OF EUT CONSTRUCTIONAL
Reference to the document No.: External photo and Internal photo




                    **********************THE END**********************




                                                      CTC Laboratories, Inc
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cncaic.cn



Document Created: 2019-02-23 17:46:42