RF Exposure Report

FCC ID: 2AB3N-HP20

RF Exposure Info

Download: PDF
FCCID_4284855

                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                  1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
                                  Shenzhen, China
                                  Telephone:     +86-755-26648640
                                  Fax:           +86-755-26648637                 Report Template Version: V03
                                  Website:       www.cqa-cert.com                 Report Template Revision Date: Mar.1st, 2017



                RF Exposure Evaluation Report

Report No. :                      CQASZ20181000023E-03
Applicant:                        S&O ELECTRONICS (MALAYSIA) SDN. BHD.
Address of Applicant:             LOT 202, BAKAR ARANG INDUSTRIAL ESTATE, 08000 SUNGAI PETANI,
                                  KEDAH, Malaysia
Manufacturer:                     S&O ELECTRONICS (MALAYSIA) SDN. BHD.
Address of Manufacturer:          LOT 202, BAKAR ARANG INDUSTRIAL ESTATE, 08000 SUNGAI PETANI,
                                  KEDAH, Malaysia
Factory:                          Shenzhen Shuaixian Electronic Equipment Co., Ltd.
Address of Factory:               NO.10 Lane3, Longxing Rd., Dakang Long Village, Henggang Town, Longgang
                                  Dist., Shenzhen, China
Equipment Under Test (EUT):
Product:                          Stereo Headphones
Model No.:                        HP-20
Brand Name:                       SHARP
FCC ID:                           2AB3N-HP20
Standards:                        47 CFR Part 1.1307
                                  47 CFR Part 2.1093
                                  KDB447498D01 General RF Exposure Guidance v06
Date of Test:                     2018-10-16 to 2018-10-22
Date of Issue:                    2018-10-22
Test Result :                     PASS*


Tested By:
                                                ( Martin Lee)


Reviewed By:
                                                ( Aaron Ma)


Approved By:
                                                  ( Jack Ai)




* In the configuration tested, the EUT complied with the standards specified above.

The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to

the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full.


                                    Shenzhen Huaxia Testing Technology Co., Ltd
                                                      Report No.: CQASZ20181000023E-03


1   Version
                            Revision History Of Report

          Report No.          Version         Description           Issue Date
     CQASZ20181000023E-03     Rev.01         Initial report        2018-10-22




                              Page:2 of 7


                                                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                                    Report No.: CQASZ20181000023E-03



2         Contents
                                                                                                                                                                         Page
1       VERSION .....................................................................................................................................................................2

2       CONTENTS .................................................................................................................................................................3

3       GENERAL INFORMATION .......................................................................................................................................4
    3.1     CLIENT INFORMATION................................................................................................................................................4
    3.2     GENERAL DESCRIPTION OF EUT ................................................................................................................................4
4       SAR EVALUATION ....................................................................................................................................................5
    4.1 RF EXPOSURE COMPLIANCE REQUIREMENT ..............................................................................................................5
       4.1.1 Standard Requirement .................................................................................................................................5
       4.1.2 Limits ..............................................................................................................................................................5
       4.1.3 EUT RF Exposure .........................................................................................................................................6




                                                                     Page:3 of 7


                                             Shenzhen Huaxia Testing Technology Co., Ltd
                                                                    Report No.: CQASZ20181000023E-03



3   General Information
3.1 Client Information
    Applicant:                 S&O ELECTRONICS (MALAYSIA) SDN. BHD.
    Address of Applicant:      LOT 202, BAKAR ARANG INDUSTRIAL ESTATE, 08000 SUNGAI
                               PETANI, KEDAH, Malaysia
    Manufacturer:              S&O ELECTRONICS (MALAYSIA) SDN. BHD.
    Address of Manufacturer:   LOT 202, BAKAR ARANG INDUSTRIAL ESTATE, 08000 SUNGAI
                               PETANI, KEDAH, Malaysia
    Factory:                   Shenzhen Shuaixian Electronic Equipment Co., Ltd.
    Address of Factory:        NO.10 Lane3, Longxing Rd., Dakang Long Village, Henggang Town,
                               Longgang Dist., Shenzhen, China

3.2 General Description of EUT
    Product Name:              Stereo Headphones
    Model No.:                 HP-20
    Trade Mark:                SHARP
    Hardware Version:          A0
    Software Version:          A0
    Operation Frequency:       2402MHz~2480MHz
    Bluetooth Version:         V5.0
                               BT classic: GFSK, π/4DQPSK, 8DPSK
    Modulation Type:
                               BLE: GFSK
                               BT classic:79
    Number of Channel:
                               BLE:40
    Sample Type:               portable production
    Test Software of EUT:      Blue test 3(manufacturer declare )
    Antenna Type:              PCB antenna
    Antenna Gain:              0dBi
    Power Supply:              lithium battery:DC3.7V 300mAh, Charge by DC5.0V




                                       Page:4 of 7


                                                Shenzhen Huaxia Testing Technology Co., Ltd
                                                                     Report No.: CQASZ20181000023E-03



4    SAR Evaluation
4.1 RF Exposure Compliance Requirement
4.1.1 Standard Requirement
     According to KDB447498D01 General RF Exposure Guidance v06
     4.3.1. Standalone SAR test exclusion considerations
           Unless specifically required by the published RF exposure KDB procedures, standalone 1-g
     head or body and 10-g extremity SAR evaluation for general population exposure conditions, by
     measurement or numerical simulation, is not required when the corresponding SAR Exclusion
     Threshold condition, listed below, is satisfied.
4.1.2 Limits
     The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:

     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
     [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where

        f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation17
        The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion




                                         Page:5 of 7


                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                       Report No.: CQASZ20181000023E-03




4.1.3 EUT RF Exposure
Measurement Data
                                               GFSK mode
                                                       Tune up tolerance             Maximum tune-up Power
       Test channel              Peak Output Power
                                      (dBm)                      (dBm)                (dBm)         (mW)

    Lowest(2402MHz)                   2.000                      1.5±1                   2.5        1.778
     Middle(2441MHz)                  4.250                      3.5±1                   4.5        2.818
    Highest(2480MHz)                  3.060                      3.0±1                   4.0        2.512
                                             π/4DQPSK mode
                                                       Tune up tolerance             Maximum tune-up Power
       Test channel              Peak Output Power
                                      (dBm)                      (dBm)                (dBm)         (mW)

    Lowest(2402MHz)                   -0.190                     -0.5±1                  0.5        1.122
     Middle(2441MHz)                  2.870                      2.5±1                   3.0        1.995
    Highest(2480MHz)                  1.290                      1.0±1                   2.0        1.585
                                              8DPSK mode
                                                       Tune up tolerance             Maximum tune-up Power
       Test channel              Peak Output Power
                                      (dBm)                      (dBm)                              (mW)
                                                                                      (dBm)
    Lowest(2402MHz)                   0.670                       0±1                    1.0        1.259
     Middle(2441MHz)                  3.320                      2.5±1                   3.5        2.239
    Highest(2480MHz)                  1.540                      1.0±1                   2.0        1.585

  Worst case: GFSK
                       Maximum                         Maximum tune-
                         Peak           Tune up             up Power
                                                                            Calculated         Exclusion
     Channel           Conducted        tolerance
                                                                              value            threshold
                      Output Power       (dBm)         (dBm)     (mW)
                         (dBm)
      Lowest
                         2.000            1.5±1         2.5      1.778        0.55
    (2402MHz)
      Middle
                                                                                                  3.0
    (2441MHz)            4.250            3.5±1         4.5      2.818        0.88

      Highest
    (2480MHz)            3.060            3.0±1         4.0      2.512        0.79

  Conclusion: the calculated value ≤3.0, SAR is exempted.

Remark: The Max Conducted Peak Output Power data refer to report Report No.: CQASZ20181000023E-01



                                         Page:6 of 7


                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                       Report No.: CQASZ20181000023E-03



2) For BLE
Measurement Data
                                               GFSK mode
                                                       Tune up tolerance             Maximum tune-up Power
       Test channel              Peak Output Power
                                      (dBm)                      (dBm)                (dBm)         (mW)

     Lowest(2402MHz)                   3.73                      3.5±1                   4.5        2.818
     Middle(2440MHz)                   5.09                      4.5±1                   5.5        3.548
    Highest(2480MHz)                   4.12                      3.5±1                   4.5        2.818



  Worst case: GFSK
                       Maximum                         Maximum tune-
                         Peak           Tune up             up Power
                                                                            Calculated         Exclusion
     Channel           Conducted        tolerance
                                                                              value            threshold
                      Output Power       (dBm)         (dBm)     (mW)
                         (dBm)
      Lowest
                          3.73            3.5±1         4.5      2.818        0.87
    (2402MHz)
      Middle
                                                                                                  3.0
    (2440MHz)             5.09            4.5±1         5.5      3.548        1.11

      Highest
    (2480MHz)             4.12            3.5±1         4.5      2.818        0.89

  Conclusion: the calculated value ≤3.0, SAR is exempted.

Remark: The Max Conducted Peak Output Power data refer to report Report No.: CQASZ20181000023E-02



BDR, EDR and BLE can not simultaneous transmitting at same time.




                                         Page:7 of 7