                        RF Exposure evaluation


According to 447498   D01 General RF Exposure Guidance v05
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at
test separation distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test
separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for
10-g extremity SAR, where
 f(GHz) is the RF channel transmit frequency in GHz
 Power and distance are rounded to the nearest mW and mm before
calculation
 The result is rounded to one decimal place for comparison


Worse case is as below: [2402 MHz 0.52dBm(1.127mW) output power]


(1.127 mW /5mm) ·[√2.402 (GHz)]= 0.35    <3.0 for 1-g SAR


Then SAR evaluation is not required