FCC Part 15C test report

FCC ID: 2AB2QLZW30

Test Report

Download: PDF
FCCID_4403201

Report Number: 68.912.19.0013.01




                                                          FCC/IC - TEST REPORT



  Report Number                                          : 68.912.19.0013.01                              Date of Issue:                     August 02, 2019


 Model                                                   : LZW30

 Product Type                                            : On/Off Switch

 Applicant                                               : LEEDARSON LIGHTING CO., LTD

 Address                                                 : Xingda Road, Xingtai Industrial Zone, Changtai County,

                                                             Zhangzhou, Fujian, China

 Production Facility                                     : LEEDARSON LIGHTING CO., LTD

 Address                                                 : Xingda Road, Xingtai Industrial Zone, Changtai County,

                                                             Zhangzhou, Fujian, China


  Test Result                                            : n Positive                   o Negative



  Total pages including
  Appendices                                             : 32



TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined
in ISO 17025.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test
conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this
model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe
for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co.,
Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and
Testing (China) Co., Ltd. Shenzhen Branch issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




 EMC_SZ_FR_23.00 FCC                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                           Page 1 of 32
                                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 1 Table of Contents

  1 Table of Contents ......................................................................................................................................................... 2
  2 Details about the Test Laboratory ................................................................................................................................. 3
  3 Description of the Equipment Under Test ..................................................................................................................... 4
  4 Summary of Test Standards .......................................................................................................................................... 5
  5 Summary of Test Results.............................................................................................................................................. 6
  6 General Remarks .......................................................................................................................................................... 7
  7 Test setups ................................................................................................................................................................... 8
  8 Systems test configuration ............................................................................................................................................ 9
  9 Technical Requirement ............................................................................................................................................... 10
     9.1 Conducted Emission ............................................................................................................................................ 10
     9.2 Field strength of emissions and Restricted bands .................................................................................................. 13
     9.3 Out of Band Emissions ........................................................................................................................................ 18
     9.4 20dB Bandwidth & 99% Occupied Bandwidth ..................................................................................................... 27
  10 Test equipment lists .................................................................................................................................................. 31
  11 System Measurement Uncertainty ............................................................................................................................. 32




 EMC_SZ_FR_23.00 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                  Page 2 of 32
                                               Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                           District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 2 Details about the Test Laboratory

 Details about the Test Laboratory

 Test Site 1

 Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                       Building 12&13, Zhiheng Wisdomland Business Park,
                       Nantou Checkpoint Road 2, Nanshan District,
                       Shenzhen City, 518052,
                       P. R. China

 FCC Registration      514049
 Number:

 ISED#:                10320A

 CAB identifier:       CN0077

 Telephone:            86 755 8828 6998
 Fax:                  86 755 8828 5299


 Test Site 2

 Company name:         Dongguan Dongdian Testing Service Co., Ltd.
                       No.17,Zong bu Road 2, Songshan Lake Sci&Tech, Industry Park,
                       Dongguan City,Guangdong Province, China, 523808

 Telephone:            +86-0769-38826678
 Fax:                  +86-0769-38826678

 IC Registration       10288A
 No.:

 CAB identifier:       CN0048




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 3 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 3 Description of the Equipment Under Test

 Description of the Equipment Under Test

 Product/PMN:                      On/Off Switch

 Model no./HVIN:                   LZW30

 FCC ID:                           2AB2QLZW30

 IC:                               10256A-LZW30

 Options and accessories:          NIL

 Rated Voltage:                    AC 120V/60Hz;

 Rated Power:                      1200W for Resistive load
                                   600W for Incandescent Lamp;
                                   300W for LED Lamp;
                                   150W for CFL

 RF Transmission                   908.4MHz, 908.42MHz, 916MHz
 Frequency:

 Modulation:                       908.4MHz, 908.42MHz for FSK
                                   916MHz for GFSK

 Antenna Type:                     PCB

 Antenna Gain:                     -1.8dBi

 Description of the EUT:           The product is an On/Off Switch that operated at the
                                   908.4MHz, 908.42MHz, 916MHz;

Auxiliary Equipment Used during Test:

        DESCRIPTION            MANUFACTURER                              RATINGS                       MODEL NO.(SHIELD)
               ---                         ---                                 ---                                   ---




 EMC_SZ_FR_23.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 32
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20        District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 4 Summary of Test Standards

                                        Test Standards
 FCC Part 15 Subpart C      PART 15 - RADIO FREQUENCY DEVICES
 10-1-2017 Edition          Subpart C - Intentional Radiators
 RSS-Gen                    General Requirements and Information for the Certification of
 Issue 5, Amendment 1,      Radio Apparatus
 March 2019
 RSS-210 Issue 9            RSS-210 — Licence-exempt Radio Apparatus (All Frequency
 August 2016                Bands): Category I Equipment

All the test methods were according to ANSI C63.10-2013.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 5 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 5 Summary of Test Results

                               Technical Requirements
 FCC Part 15 Subpart C 15.249, RSS-Gen, RSS-210
 Test Condition                                   Pages                                      Test             Test Result
                                                                                              Site         Pass Fail N/A
 15.207 & RSS-Gen A8.8                                                            10         Site 1
 Conducted emission AC power port
 §15.205(a), §15.209(a), §15.249(a), §15.249(c) &                                 13         Site 2
 RSS-210 B.10, RSS-GEN 6.13/8.9/8.10
 Field strength of emissions and Restricted bands
 §15.249(d), RSS-210 B.10                                                         18         Site 2
 Out of band emissions
 FCC §15.215(c) 20dB bandwidth                                                    23         Site 2
 & RSS-Gen 6.7 99% Occupied Bandwidth
 §15.203, RSS-GEN 6.8                                                             See note 1
 Antenna requirement

Remark 1: N/A- Not Applicable;
Note 1: The EUT used an integral PCB antenna, which gain is -1.8dBi. According to §15.203,
it is considered sufficiently to comply with the provisions of this section.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 6 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 6 General Remarks

Remarks
This submittal(s) (test report) is intended for FCC ID: 2AB2QLZW30 and IC: 10256A-LZW30
complies with Section 15.207, 15.205, 15.209, 15.249 of the FCC Part 15, Subpart C Rules;
RSS-Gen Issue 5 and RSS-210 issue 9.


SUMMARY:

All tests according to the regulations cited on page 5 were


n - Performed

o - Not Performed

The Equipment Under Test

n - Fulfills the general approval requirements.

o - Does not fulfill the general approval requirements.


 Sample Received Date:                        July 26, 2019

 Testing Start Date:                          July 26, 2019

 Testing End Date:                          August 02, 2019


- TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch -
 Reviewed by:              Prepared by:                     Tested by:                                 Tested by:




 ___________________                                        _______________________                    _______________________
                         __________________
    Laurent Yuan              Henry Chen                           Louise Liu                                Sunny Zhang
    EMC Project               EMC Project                       EMC Test Engineer                          EMC Test Engineer
      Manager                  Engineer                            Test Site 1                                Test Site 2




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 7 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 7 Test setups

7.1 Radiated test setups

Below 1GHz




Above 1GHz




7.2 AC Power Line Conducted Emission test setups




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 8 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 8 Systems test configuration

Auxiliary Equipment Used during Test:

           DESCRIPTION           MANUFACTURER                         MODEL NO.                              S/N
                 ---                        ---                              ---                              ---


Test software information:

                  TEST SOFTWARE VERSION                                        SSCOM
                         FREQUENCY                       MODULATION                SETTING TX POWER
                          908.4 MHZ                             FSK                            23
                          908.42 MHZ                            FSK                            23
                           916 MHZ                             GFSK                            23




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 9 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 9 Technical Requirement

9.1 Conducted Emission
Test Method
   1. The EUT was placed on a table, which is 0.8m above ground plane
   2. The power line of the EUT is connected to the AC mains through a Artificial Mains
      Network (A.M.N.).
   3. Maximum procedure was performed to ensure EUT compliance
   4. A EMI test receiver is used to test the emissions from both sides of AC line

Limit

                        Frequency                         QP Limit                        AV Limit
                           MHz                             dBμV                            dBμV
                        0.150-0.500                        66-56*                          56-46*
                          0.500-5                            56                              46
                           5-30                              60                              50

*Decreasing linearly with logarithm of the frequency.




 EMC_SZ_FR_23.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 10 of 32
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20        District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Conducted Emission
 Product Type                :              On/Off Switch
 M/N                         :              LZW30
 Operating Condition         :              Normal working with transmitting
 Test specification          :              Positive
 Comment                     :              AC 120V/60Hz


                                       80

                                       70

                                       60
                       Level in dBµV




                                       50

                                       40

                                       30

                                       20

                                       10

                                       0
                                       150k         300 400 500    800 1M         2M     3M 4M 5M 6     8 10M         20M    30M
                                                                             Frequency in Hz



                                       Frequency         MaxPeak        Average         Limit    Margin      Line    Corr.
                                         (MHz)            (dBµV)        (dBµV)         (dBµV)     (dB)               (dB)
                                          0.266000           54.66            ---        61.24      6.58     L1       10.2
                                          0.266000              ---        51.79         51.24     -0.54     L1       10.2
                                          0.902000           46.05            ---        56.00      9.95     L1       10.3

                                       Frequency        QuasiPeak        Average        Limit     Margin      Line     Corr.
                                         (MHz)           (dBµV)           (dBµV)       (dBµV)      (dB)                (dB)
                                          0.153500              ---         52.75        55.81       3.06     L1        10.2
                                          0.153500           54.68             ---       65.81      11.13     L1        10.2
                                          0.177500              ---         52.76        54.60       1.84     L1        10.2
                                          0.177500           55.31             ---       64.60       9.29     L1        10.2
                                          0.201500              ---         51.16        53.55       2.39     L1        10.2
                                          0.201500           55.06             ---       63.55       8.49     L1        10.2
                                          0.221500           54.74             ---       62.76       8.02     L1        10.2
                                          0.221500              ---         51.21        52.76       1.55     L1        10.2
                                          0.222500           54.75             ---       62.73       7.98     L1        10.2
                                          0.222500              ---         51.01        52.73       1.72     L1        10.2
                                          0.241500              ---         50.30        52.04       1.74     L1        10.2
                                          0.241500           54.38             ---       62.04       7.66     L1        10.2
                                          0.289500              ---         48.09        50.54       2.45     L1        10.2
                                          0.289500           53.40             ---       60.54       7.14     L1        10.2
                                          0.305500              ---         46.97        50.09       3.12     L1        10.2
                                          0.305500           52.73             ---       60.09       7.36     L1        10.2
                                          0.317500              ---         44.36        49.77       5.41     L1        10.2
                                          0.317500           52.14             ---       59.77       7.63     L1        10.2
                                          0.326500              ---         45.80        49.54       3.74     L1        10.2
                                          0.326500           51.98             ---       59.54       7.56     L1        10.2
                                          0.357500              ---         45.02        48.79       3.77     L1        10.2
                                          0.357500           51.22             ---       58.79       7.57     L1        10.2
                                          0.386500              ---         43.32        48.14       4.82     L1        10.3
                                          0.386500           49.46             ---       58.14       8.68     L1        10.3


Remark:
Level=Reading Level + Correction Factor
Correction Factor=Cable Loss + LISN Factor
(The Reading Level is recorded by software which is not shown in the sheet)


 EMC_SZ_FR_23.00 FCC                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 11 of 32
                                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Conducted Emission
 Product Type                       :     On/Off Switch
 M/N                                :     LZW30
 Operating Condition                :     Normal working with transmitting
 Test specification                 :     Negative
 Comment                            :     AC 120V/60Hz



                             80

                             70

                             60
             Level in dBµV




                             50

                             40

                             30

                             20

                             10

                             0
                             150k         300 400 500         800 1M             2M      3M 4M 5M 6              8 10M          20M       30M
                                                                           Frequency in Hz



                                        Frequency      QuasiPeak        Average        Limit     Margin      Line     Corr.
                                          (MHz)         (dBµV)           (dBµV)       (dBµV)      (dB)                (dB)
                                           0.177500            ---         52.91        54.60       1.69     N         10.2
                                           0.177500         55.35             ---       64.60       9.25     N         10.2
                                           0.197500            ---         52.07        53.72       1.65     N         10.2
                                           0.197500         55.17             ---       63.72       8.55     N         10.2
                                           0.201500            ---         51.38        53.55       2.17     N         10.2
                                           0.201500         55.17             ---       63.55       8.38     N         10.2
                                           0.245500            ---         49.97        51.91       1.94     N         10.2
                                           0.245500         54.39             ---       61.91       7.52     N         10.2
                                           0.261500            ---         48.66        51.38       2.72     N         10.2
                                           0.261500         53.84             ---       61.38       7.54     N         10.2
                                           0.265500            ---         49.34        51.26       1.92     N         10.2
                                           0.265500         53.68             ---       61.26       7.58     N         10.2
                                           0.313500            ---         46.96        49.88       2.92     N         10.3
                                           0.313500         52.71             ---       59.88       7.17     N         10.3
                                           0.329500            ---         45.83        49.46       3.63     N         10.3
                                           0.329500         52.09             ---       59.46       7.37     N         10.3
                                           0.385500            ---         43.54        48.16       4.62     N         10.3
                                           0.385500         49.86             ---       58.16       8.30     N         10.3


Remark:
Level=Reading Level + Correction Factor
Correction Factor=Cable Loss + LISN Factor
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch               Page 12 of 32
                                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                         District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 9.2 Field strength of emissions and Restricted bands
Test Method

   1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
   and 0.8m above ground for below 1GHz at 3-meter chamber room for test. The table was
   rotated 360 degrees to determine the position of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical
   polarizations of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:

   For Above 1GHz
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
      measurement, Sweep = auto, Detector function = peak, Trace = max hold.

   For Below 1GHz
   Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function
      = peak, Trace = max hold.

Note:
        1: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
        120 KHz for Quasi-peak detection (QP) at frequency below 1GHz.
        2: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 3MHz for peak detection (PK) at frequency above 1GHz.
        3: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 3MHz for RMS Average ((duty cycle ˂ 98%) for Average detection (AV) at
        frequency above 1GHz, then the measurement results was added to a correction factor
        (20log (1/duty cycle)).
        4: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 10Hz (duty cycle ˃ 98%) for Average detection (AV) at frequency above
        1GHz.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 13 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Field strength of emissions and Restricted bands
Limits
According to §15.249 (a) & RSS-210 A2.9(a) , the field strength of emissions from intentional
radiators operated within these frequency bands shall comply with the following:

                                   Field strength of fundamental Field strength of harmonics
   Fundamental frequency
                                   (millivolts/meter)            (microvolts/meter)
   902–928 MHz                     50                                                 500
   2400–2483.5 MHz                 50                                                 500
   5725–5875 MHz                   50                                                 500
   24.0–24.25 GHz                  250                                                2500

According to §15.249 (c)& RSS-210 B.10, Field strength limits are specified at a distance of 3
meters.
According to §15.249 (d)& RSS-210 B.10, Emissions radiated outside of the specified
frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level
of the fundamental or to the general radiated emission limits in §15.209& RSS-Gen, whichever
is the lesser attenuation.
According to §15.205 and RSS-GEN 8.10 Unwanted emissions falling into restricted bands in
§15.205 (a) and RSS-GEN 8.10 Table 7 shall comply with the limits specified in §15.209 and
RSS-Gen.

            Frequency               Field Strength                  Field Strength                        Detector
               MHz                       uV/m                          dBμV/m
               30-88                      100                             40                                  QP
              88-216                      150                            43.5                                 QP
             216-960                      200                             46                                  QP
             960-1000                     500                             54                                  QP
            Above 1000                    500                             54                                  AV
            Above 1000                   5000                             74                                  PK




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 14 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Field strength of emissions and Restricted bands

According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit, it is
unnecessary to perform an average measurement, so AV emission value did not show in
below table if the peak value complies with average limit.

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 908.4MHz

For Peak& QP Value
                                                                      Radiated Emission
           Emissions                          Reading           Amplifier    Antenna      Cable
                               E-Field         Level             Gain         Factor      Loss
                                                                                                     Emission        Limit           Margin        Emission
 Value     Frequency
                               Polarity                           dB                                dBµV/m          dBµV/m            dBm           Type
              MHz                             dBµV/m                         dB/m           dB
   QP          44.74               H             3.77              /          14.00        3.82          21.59          40.00        18.41          Spurious
   QP          48.33               V             2.14              /          14.42        3.85          20.41          40.00        19.59          Spurious
   PK         908.40               H             64.78             /          21.80        6.96          93.54          114.00       20.46        Fundam ental
   PK         908.40               V             57.85             /          21.80        6.96          86.61          114.00       27.39        Fundam ental
   PK        13716.00              H             46.91           39.52        43.16        9.47          52.74          74.00        21.26          Spurious
   PK        14124.00              V             46.10           40.23        43.08        9.64          52.89          74.00        21.11          Spurious

For AV Value
                                                                      Radiated Emission
                                                                                         AV
          Emissions                    Reading      Amplifier      Antenna   Cable                Average          AV
                        E-Field                                                        Reading                                Limit      Margin       Emission
 Value    Frequency                     Level        Gain           Factor   Loss                  Factor        Emission
                        Polarity                                                        Level                                dBµV/m      dBm           Type
             MHz                       dBµV/m         dB            dB/m      dB                    dB           dBµV/m
                                                                                       dBµV/m
  AV           /           H              /              /             /       /          /          0              /            /            /       Spurious
  AV           /           V              /              /             /       /          /          0              /            /            /       Spurious
 Average Factor=10log(dutycycle), dutycycle=100%


Remark:
1: Data of measurem ent within this frequency range shown “/” in the table above means the reading of emissions are attenuated more than
   20db below the permissible limits or the field strength is too small to be measured.
2: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.
3: AV Emission Level= AV Reading Level+10log(1/dutycycle)
4: PK Emission = Reading Level + Correction Factor
AV Emission = Reading Level + Correction Factor
Correction Factor=Antenna Factor + Cable Loss (For Below 1GHz)
Correction Factor = Antenna Factor + Cable Loss- Amplifier Gain (For Above 1GHz)
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 15 of 32
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Field strength of emissions and Restricted bands


EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 908.42MHz

For Peak& QP Value
                                                                      Radiated Emission
           Emissions                          Reading           Amplifier    Antenna      Cable
                               E-Field                           Gain                                Emission        Limit           Margin        Emission
 Value     Frequency                           Level                          Factor      Loss
                               Polarity                           dB                                dBµV/m          dBµV/m            dBm           Type
              MHz                             dBµV/m                         dB/m           dB
   QP         742.26               H             3.21              /          20.36        6.49          30.06          46.00        15.94          Spurious
   QP         807.43               V             2.69              /          20.78        6.62          30.09          46.00        15.91          Spurious
   PK         908.42               H             64.51             /          21.80        6.96          93.27          114.00       20.73        Fundam ental
   PK         908.42               V             59.66             /          21.80        6.96          88.42          114.00       25.58        Fundam ental
   PK        14090.00              H             46.61           40.22        43.09        9.62          53.36          74.00        20.64          Spurious
   PK        13920.00              V             45.94           40.01        43.12        9.54          52.37          74.00        21.63          Spurious

For AV Value
                                                                      Radiated Emission
                                                                                         AV
          Emissions                    Reading      Amplifier      Antenna   Cable                Average          AV
                        E-Field                                                        Reading                                Limit      Margin       Emission
 Value    Frequency                     Level        Gain           Factor   Loss                  Factor        Emission
                        Polarity                                                        Level                                dBµV/m      dBm           Type
             MHz                       dBµV/m         dB            dB/m      dB                    dB           dBµV/m
                                                                                       dBµV/m
  AV           /           H              /              /             /       /          /          0              /            /            /       Spurious
  AV           /           V              /              /             /       /          /          0              /            /            /       Spurious
 Average Factor=10log(dutycycle), dutycycle=100%


Remark:
1: Data of measurem ent within this frequency range shown “/” in the table above means the reading of emissions are attenuated more than
   20db below the permissible limits or the field strength is too small to be measured.
2: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.
3: AV Emission Level= AV Reading Level+10log(1/dutycycle)
4: PK Emission = Reading Level + Correction Factor
AV Emission = Reading Level + Correction Factor
Correction Factor=Antenna Factor + Cable Loss (For Below 1GHz)
Correction Factor = Antenna Factor + Cable Loss- Amplifier Gain (For Above 1GHz)
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 16 of 32
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Field strength of emissions and Restricted bands

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 916MHz

For Peak& QP Value
                                                                      Radiated Emission
           Emissions                          Reading           Amplifier    Antenna      Cable
                               E-Field         Level             Gain         Factor      Loss
                                                                                                     Emission        Limit           Margin        Emission
 Value     Frequency
                               Polarity                           dB                                dBµV/m          dBµV/m            dBm           Type
              MHz                             dBµV/m                         dB/m           dB
   QP         658.84               H             3.78              /          19.47        6.26          29.51          46.00        16.49          Spurious
   QP         704.23               V             3.06              /          20.13        6.39          29.58          46.00        16.42          Spurious
   PK         916.00               H             63.51             /          21.88        6.99          92.38          114.00       21.62        Fundam ental
   PK         916.00               V             58.50             /          21.88        6.99          87.37          114.00       26.63        Fundam ental
   PK        14430.00              H             45.92           40.29        43.01        9.81          53.01          74.00        20.99          Spurious
   PK        14141.00              V             45.91           40.23        43.07        9.65          52.72          74.00        21.28          Spurious

For AV Value
                                                                      Radiated Emission
                                                                                         AV
          Emissions                    Reading      Amplifier      Antenna   Cable                Average          AV
                        E-Field                                                        Reading                                Limit      Margin       Emission
 Value    Frequency                     Level        Gain           Factor   Loss                  Factor        Emission
                        Polarity                                                        Level                                dBµV/m      dBm           Type
             MHz                       dBµV/m         dB            dB/m      dB                    dB           dBµV/m
                                                                                       dBµV/m
  AV           /           H              /              /             /       /          /          0              /            /            /       Spurious
  AV           /           V              /              /             /       /          /          0              /            /            /       Spurious
 Average Factor=10log(dutycycle), dutycycle=100%


Remark:
1: Data of measurem ent within this frequency range shown “/” in the table above means the reading of emissions are attenuated more than
   20db below the permissible limits or the field strength is too small to be measured.
2: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.
3: AV Emission Level= AV Reading Level+10log(1/dutycycle)
4: PK Emission = Reading Level + Correction Factor
AV Emission = Reading Level + Correction Factor
Correction Factor=Antenna Factor + Cable Loss (For Below 1GHz)
Correction Factor = Antenna Factor + Cable Loss- Amplifier Gain (For Above 1GHz)
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 17 of 32
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 9.3 Out of Band Emissions
Test Method

   1 Use the following spectrum analyzer settings:
     Span = wide enough to capture the peak level of the in-band emission and all spurious
     RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max
     hold.
   2 Allow the trace to stabilize, use the peak and delta measurement to record the result.
   3 The level displayed must comply with the limit specified in this Section.


Limits
According to §15.249(d) & RSS-210 B.10 Emissions radiated outside of the specified
frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level
of the fundamental or to the general radiated emission limits in §15.209 and RSS-Gen,
whichever is the lesser attenuation.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 18 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Out of Band Emissions

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 908.4MHz
Polarization: Horizontal




        Item     Freq.    Read     Antenna       Cable       Result         Limit       Over       Detector        Polarization
                          Level     Factor       Loss        Level          Line        Limit
        (Mark)   (MHz)    (dBµV)    (dB/m)         dB       (dBµV/m)      (dBµV/m)       (dB)
          1      605.66   5.31       18.60        6.11        30.02         46.00       -15.98       Peak         HORIZONTAL
          2      614.00   4.09       18.74        6.13        28.96         46.00       -17.04       Peak         HORIZONTAL




 EMC_SZ_FR_23.00 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 19 of 32
                               Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20           District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Out of Band Emissions

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 908.4MHz
Polarization: Vertical




         Item    Freq.    Read     Antenna       Cable       Result         Limit       Over       Detector       Polarization
                          Level     Factor       Loss        Level          Line        Limit
        (Mark)   (MHz)    (dBµV)    (dB/m)         dB       (dBµV/m)      (dBµV/m)       (dB)
          1      601.43   5.74       18.52        6.10        30.36         46.00       -15.64       Peak          VERTICAL
          2      614.00   4.44       18.74        6.13        29.31         46.00       -16.69       Peak          VERTICAL




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 20 of 32
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Out of Band Emissions

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 908.4MHz
Polarization: Horizontal




Item      Freq.     Read     Antenna       PRM         Cable         Result          Limit        Over       Detector       Polarization
                    Level     Factor      Factor       Loss          Level           Line         Limit
(Mark)    (MHz)     (dBµV)    (dB/m)         dB           dB        (dBµV/m)       (dBµV/m)        (dB)
  1       4774.00   49.71     33.77        44.24         5.83        45.07           74.00        -28.93        Peak       HORIZONTAL
  2       7970.00   47.84     36.28        43.11         6.59        47.60           74.00        -26.40        Peak       HORIZONTAL
  3       9619.00   48.60     37.18        43.93         7.64        49.49           74.00        -24.51        Peak       HORIZONTAL
  4      11455.00   46.48     38.50        43.70         8.47        49.75           74.00        -24.25        Peak       HORIZONTAL
  5      13240.00   47.25     38.64        43.27         9.30        51.92           74.00        -22.08        Peak       HORIZONTAL
  6      13716.00   46.91     39.52        43.16         9.47        52.74           74.00        -21.26        Peak       HORIZONTAL




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 21 of 32
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Out of Band Emissions

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 908.4MHz
Polarization: Vertical




Item      Freq.     Read     Antenna       PRM         Cable         Result          Limit        Over       Detector       Polarization
                    Level     Factor      Factor       Loss          Level           Line         Limit
(Mark)    (MHz)     (dBµV)    (dB/m)         dB           dB        (dBµV/m)       (dBµV/m)        (dB)
  1       3584.00   49.93     32.24        44.40         5.16        42.93           74.00        -31.07        Peak         VERTICAL
  2       6304.00   48.65     35.07        43.85         6.09        45.96           74.00        -28.04        Peak         VERTICAL
  3       8786.00   47.98     36.80        43.52         7.14        48.40           74.00        -25.60        Peak         VERTICAL
  4      10894.00   48.05     37.54        43.85         8.17        49.91           74.00        -24.09        Peak         VERTICAL
  5      12016.00   47.88     38.00        43.56         8.79        51.11           74.00        -22.89        Peak         VERTICAL
  6      14124.00   46.10     40.23        43.08         9.64        52.89           74.00        -21.11        Peak         VERTICAL




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 22 of 32
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Out of Band Emissions

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 916MHz
Polarization: Horizontal




        Item     Freq.    Read     Antenna       Cable       Result         Limit       Over       Detector        Polarization
                          Level     Factor       Loss        Level          Line        Limit
        (Mark)   (MHz)    (dBµV)    (dB/m)         dB       (dBµV/m)      (dBµV/m)       (dB)
          1      960.00   6.12       22.37        7.06        35.55         46.00       -10.45       Peak         HORIZONTAL
          2      975.75   6.33       22.54        7.06        35.93         54.00       -18.07       Peak         HORIZONTAL




 EMC_SZ_FR_23.00 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 23 of 32
                               Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20           District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Out of Band Emissions

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 916MHz
Polarization: Vertical




         Item    Freq.    Read     Antenna       Cable       Result         Limit       Over       Detector       Polarization
                          Level     Factor       Loss        Level          Line        Limit
        (Mark)   (MHz)    (dBµV)    (dB/m)         dB       (dBµV/m)      (dBµV/m)       (dB)
          1      960.00   6.00       22.37        7.06        35.43         46.00       -10.57       Peak          VERTICAL
          2      993.01   5.34       22.73        7.05        35.12         54.00       -18.88       Peak          VERTICAL




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 24 of 32
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Out of Band Emissions

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 916MHz
Polarization: Horizontal




Item      Freq.     Read     Antenna       PRM         Cable         Result          Limit        Over       Detector       Polarization
                    Level     Factor      Factor       Loss          Level           Line         Limit
(Mark)    (MHz)     (dBµV)    (dB/m)         dB           dB        (dBµV/m)       (dBµV/m)        (dB)
  1       4009.00   49.89     32.91        44.40         5.66        44.06           74.00        -29.94        Peak       HORIZONTAL
  2       4825.00   50.24     33.80        44.23         5.84        45.65           74.00        -28.35        Peak       HORIZONTAL
  3       7970.00   48.07     36.28        43.11         6.59        47.83           74.00        -26.17        Peak       HORIZONTAL
  4      10146.00   48.46     37.49        44.06         7.90        49.79           74.00        -24.21        Peak       HORIZONTAL
  5      12951.00   47.12     38.28        43.33         9.19        51.26           74.00        -22.74        Peak       HORIZONTAL
  6      14430.00   45.92     40.29        43.01         9.81        53.01           74.00        -20.99        Peak       HORIZONTAL




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 25 of 32
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 Out of Band Emissions

EUT: On/Off Switch
M/N: LZW30
Operating Condition: Tx; 916MHz
Polarization: Vertical




Item      Freq.     Read     Antenna       PRM         Cable         Result          Limit        Over       Detector       Polarization
                    Level     Factor      Factor       Loss          Level           Line         Limit
(Mark)    (MHz)     (dBµV)    (dB/m)         dB           dB        (dBµV/m)       (dBµV/m)        (dB)
  1       4009.00   49.55     32.91        44.40         5.66        43.72           74.00        -30.28        Peak         VERTICAL
  2       5590.00   49.37     34.37        44.08         5.95        45.61           74.00        -28.39        Peak         VERTICAL
  3       9364.00   48.05     37.03        43.81         7.49        48.76           74.00        -25.24        Peak         VERTICAL
  4      11166.00   48.01     37.87        43.77         8.30        50.41           74.00        -23.59        Peak         VERTICAL
  5      13291.00   47.55     38.71        43.26         9.31        52.31           74.00        -21.69        Peak         VERTICAL
  6      14141.00   45.91     40.23        43.07         9.65        52.72           74.00        -21.28        Peak         VERTICAL




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 26 of 32
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 9.4 20dB Bandwidth & 99% Occupied Bandwidth
Test Method
1.    Check the calibration of the measuring instrument using either an internal calibrator or a
      known signal from an external generator.
2.     Position the EUT without connection to measurement instrument. Turn on the EUT and
      connect it to measurement instrument. Then set it to any one convenient frequency
      within its operating range. Set a reference level on the measuring instrument equal to
      the highest peak value.
3.    Measure the frequency difference of two frequencies that were attenuated 20 dB from
      the reference level. Record the frequency difference as the emission bandwidth.

Limits:
According to 15.215 (c) Intentional radiators operating under the alternative provisions to the
general emission limits, as contained in §§ 15.217 through 15.257 and in Subpart E of this
part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever
bandwidth may otherwise be specified in the specific rule section under which the equipment
operates, is contained within the frequency band designated in the rule section under which
the equipment is operated. The requirement to contain the designated bandwidth of the
emission within the specified frequency band includes the effects from frequency sweeping,
frequency hopping and other modulation techniques that may be employed as well as the
frequency stability of the transmitter over expected variations in temperature and supply
voltage. If a frequency stability is not specified in the regulations, it is recommended that the
fundamental emission be kept within at least the central 80% of the permitted band in order to
minimize the possibility of out-of-band operation.

According to RSS-Gen 6.7 when an occupied bandwidth value is not specified in the
applicable RSS, the transmitted signal bandwidth to be reported is to be its 99% emission
bandwidth, as calculated or measured.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 27 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 20dB Bandwidth & 99% Occupied Bandwidth

                 Frequency                  20dB Bandwidth                         99% Bandwidth                   Limit
                    MHz                          KHz                                    kHz                        kHz
                   908.4                        88.141                                 86.538                        --




                                                       908.4MHz




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 28 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 20dB Bandwidth & 99% Occupied Bandwidth

                 Frequency                  20dB Bandwidth                         99% Bandwidth                   Limit
                    MHz                          KHz                                    kHz                        kHz
                   908.42                       70.512                                 81.730                        --




                                                      908.42MHz




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 29 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 20dB Bandwidth & 99% Occupied Bandwidth

                 Frequency                  20dB Bandwidth                         99% Bandwidth                   Limit
                    MHz                           KHz                                   kHz                        kHz
                    916                         128.205                               112.179                        --




                                                         916MHz




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 30 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 10 Test equipment lists

                                            List of Test Instruments

Site 1
Conducted Emission Test
  DESCRIPTION           MANUFACTURER                MODEL NO.             EQUIPMENT ID                SERIAL NO.             CAL. DUE
                                                                                                                               DATE
 EMI Test Receiver      Rohde & Schwarz                ESR 3               68-4-74-14-001                 101782             2020-6-28
       LISN             Rohde & Schwarz               ENV4200               8-4-87-14-001                 100249             2020-6-28
       LISN             Rohde & Schwarz               ENV432               68-4-87-16-001                 101318             2020-7-19
       LISN             Rohde & Schwarz               ENV216               68-4-87-14-002                 100326              2020-6-28
        ISN             Rohde & Schwarz               ENY81                68-4-87-14-003                 100177              2020-6-28
        ISN             Rohde & Schwarz             ENY81-CA6              68-4-87-14-004                 101664              2020-6-28
                                                    TK9420(VT9
High Voltage Probe      Rohde & Schwarz                                    68-4-27-14-001                9420-584             2020-6-24
                                                        420)
 RF Current Probe        Rohde & Schwarz               EZ-17              68-4-27-14-002                 100816                2020-7-2
    Attenuator          Shanghai Huaxiang            TS2-26-3             68-4-81-16-003               080928189              2020-6-28
                                                                          68-4-90-14-003-
   Test software        Rohde & Schwarz                EMC32                                         Version9.15.00              N/A
                                                                                A10

Site 2
Radiated Emission Test
       Equipment           Manufacturer           Model No.                Serial No.                 Last Cal.            Cal. Interval
   EMI Test Receiver          R&S                   ESU8                    100316                  Oct. 12, 2018            1 Year
   Spectrum analyzer         Agilent               E4447A                 MY50180031                Jun. 25, 2019            1 Year
    Trilog Broadband
                           Schwarzbeck            VULB9163                  9163-462               Nov. 09, 2018              1 Year
         Antenna
  Active Loop antenna      Schwarzbeck           FMZB-1519                  1519-038                Oct. 20, 2018             1 Year
  Double Ridged Horn
                                R&S                  HF907                    100276               Nov. 16, 2018              1 Year
         Antenna
   Broad Band Horn
                           Schwarzbeck           BBHA 9170                      790                 Oct. 25, 2018             1 Year
         Antenna
      Pre-amplifier             A.H.             PAM-0118           360       Oct. 12, 2018                                   1 Year
                                                   TRLA-
     Pre-amplifier          TERA-MW                               101303      Oct. 12, 2018                                   1 Year
                                                  0040G35
                                                CP-X2+ CP-
       RF Cable              HUBSER                           W11.03+ W12.02  Oct. 21, 2018                                   1 Year
                                                     X1
                                                SMAJ-SMAJ-
       RF Cable                  N/A                        17070133+17070131 Nov. 08, 2018                                   1 Year
                                                  1M+ 11M
                                                 C10-01-01-
       MI Cable              HUBSER                              1091629      Oct. 21, 2018                                   1 Year
                                                    1M
     Test software             Audix                 E3         V 6.11111b         N/A                                         N/A




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 31 of 32
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.912.19.0013.01




 11 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in accordance
with the recommendations of ISO 17025 were:

Site 1:
                                           System Measurement Uncertainty
                                     Test Items                                                              Extended Uncertainty
   Uncertainty for Conducted Emission 150kHz-30MHz (for test using AMN ENV432                                      3.21dB
   or ENV4200)

Site 2:
                                   Test Item                                                           Uncertainty
                                   Bandwidth                                                               1.1%
                                  Temperature                                                             0.4 ℃
                                    Humidity                                                                2%
                     Uncertainty for Radiation Emission test                                4.70 dB (Antenna Polarize: V)
                                (30 MHz-1 GHz)                                              4.84 dB (Antenna Polarize: H)
                                                                                                   4.10 dB (1-6 GHz)
                     Uncertainty for Radiation Emission test                                   4.40 dB (6 GHz-18 GHz)
                                (1 GHz-40 GHz)                                                 3.54dB (18GHz-26 GHz)
                                                                                  4.30 dB (26 GHz-40 GHz)
          Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
          level using a coverage factor of k=2.




 EMC_SZ_FR_23.00 FCC                           TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 32 of 32
                                   Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20               District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-08-24 04:53:07
Document Modified: 2019-08-24 04:53:07

© 2024 FCC.report