RF Exposure Info

FCC ID: 2AB2Q8ZA806STQ4Z

RF Exposure Info

Download: PDF
FCCID_4264712

                                        FCC RF EXPOSURE REPORT

                                                            For

                                                        Lighting

                                   MODEL NUMBER: 8Zy-A806ST-Q4Z

                                        FCC ID: 2AB2Q8ZA806STQ4Z


                                    REPORT NUMBER: 4788910050.1-6

                                         ISSUE DATE: March 15, 2019



                                                      Prepared for

                          LEEDARSON LIGHTING CO., LTD.
Xingtai Industrial Zone, Economic Development Zone, Changtai County, Zhangzhou
                           City, Fujian Province, P.R.China

                                    Prepared by
     UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
          Building 10, Innovation Technology Park, No. 1, Li Bin Road,
Song Shan Lake Hi-Tech Development Zone, Dongguan, People’s Republic of China
                              Tel: +86 769-22038881
                              Fax: +86 769 33244054
                              Website: www.ul.com




The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report
shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the
test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to
other similar products. This report does not imply that the product(s) has met the criteria for certification.


                                                                                         REPORT No.: 4788910050.1-6
                                                                                                     Page 2 of 7



                                           TABLE OF CONTENTS
1.   ATTESTATION OF TEST RESULTS ................................................................................. 3

2.   TEST METHODOLOGY ..................................................................................................... 4

3.   FACILITIES AND ACCREDITATION ................................................................................. 4

4.   DESCRIPTION OF EUT ..................................................................................................... 5

5.   REQUIREMENT ................................................................................................................. 6




                   UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                REPORT No.: 4788910050.1-6
                                                                                            Page 3 of 7

1. ATTESTATION OF TEST RESULTS
Applicant Information
Company Name:                        LEEDARSON LIGHTING CO., LTD.
Address:                             Xingtai Industrial Zone, Economic Development Zone, Changtai
                                     County, Zhangzhou City, Fujian Province, P.R.China

Manufacturer Information
Company Name:                        LEEDARSON LIGHTING CO., LTD.
Address:                             Xingtai Industrial Zone, Economic Development Zone, Changtai
                                     County, Zhangzhou City, Fujian Province, P.R.China
EUT Description
EUT Name:                            Lighting
Model:                               8Zy-A806ST-Q4Z
Series Model:                        AE 270
Model Difference:                    Please refer to section 4
Sample Status:                       Normal
Sample Received Date:                January 23, 2019
Date of Tested:                      January 24 ~ March 15, 2019



                                        APPLICABLE STANDARDS
                              STANDARD                                                 TEST RESULTS
                        FCC 47CFR§2.1091                                                  Complies
                       KDB-447498 D01 V06
Tested By:                                                      Checked By:




Kebo Zhang                                                      Shawn Wen
Engineer Project Associate                                      Laboratory Leader

Approved By:




Stephen Guo
Laboratory Manager


                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                REPORT No.: 4788910050.1-6
                                                                                            Page 4 of 7
2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with KDB 447498 D01
General RF Exposure Guidance v06.


3. FACILITIES AND ACCREDITATION
                        A2LA (Certificate No.: 4102.01)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with A2LA.
                        FCC (FCC Designation No.: CN1187)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        Has been recognized to perform compliance testing on equipment subject
                        to the Commission's Delcaration of Conformity (DoC) and Certification
                        rules
                        IC(Company No.: 21320)
Accreditation
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
Certificate
                        has been registered and fully described in a report filed with
                        Industry Canada. The Company Number is 21320.
                        VCCI (Registration No.: G-20019, R-20004, C-20012 and T-20011)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with VCCI, the
                        Membership No. is 3793.
                        Facility Name:
                        Chamber D, the VCCI registration No. is G-20019 and R-20004
                        Shielding Room B , the VCCI registration No. is C-20012 and T-20011

Note 1: All tests measurement facilities use to collect the measurement data are located at
Building 10, Innovation Technology Park, Song Shan Lake Hi tech Development Zone,
Dongguan, 523808, China

Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd.
Song Shan Lake Branch had been calibrated and compared to the open field sites and the test
anechoic chamber is shown to be equivalent to or worst case from the open field site.

Note 3: For below 30MHz, lab had performed measurements at test anechoic chamber and
comparing to measurements obtained on an open field site. And these measurements below
30MHz had been correlated to measurements performed on an OFS.




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                               REPORT No.: 4788910050.1-6
                                                                                           Page 5 of 7

4. DESCRIPTION OF EUT
EUT Name                      Lighting
Model                         8Zy-A806ST-Q4Z
Series Model:                 AE 270
Model Difference:             All the same except for the model name.
                              Operation Frequency              2405 MHz ~ 2480 MHz
Product Description           Modulation Type                               Data Rate
                              O-QPSK                                        250kbps
Power supply                  AC 120V,60Hz




                UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
    This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                 (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                REPORT No.: 4788910050.1-6
                                                                                            Page 6 of 7

5. REQUIREMENT
LIMIT
Limits for General Population/Uncontrolled Exposure

                         Limits for General Population/Uncontrolled Exposure
                         Electric Field      Magnetic Field               Power                   Averaging Time
 Frequency Range
                         Strength (E)        Strength (H)              Density (S)                 |E|2, |H|2 or S
   (MHz)
                           (V/m)                (A/m)                  (mW/cm2)                      (minutes)
      0.3-1.34               614                  1.63                    (100)*                          30
      1.34-30                824/f                2.19/f                 (180/f2)*                        30
      30-300                 27.5                 0.073                     0.2                           30
     300-1500                  --                   --                     f/150                          30
   1500-100,000                --                   --                      1.0                           30
Note 1: f = frequency in MHz, * means Plane-wave equivalent power density

Note 2: General population/uncontrolled exposures apply in situations in which the general
public may be exposed, or in which persons that are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or cannot exercise control over
their exposure.

Note 3: The limit value 1.0mW/cm2 is available for this EUT.



MPE CALCULATION METHOD

             2
S =PG/(4πR )

where: S = power density (in appropriate units, e.g. mW/ cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                REPORT No.: 4788910050.1-6
                                                                                            Page 7 of 7
CALCULATED RESULTS

Radio Frequency Radiation Exposure Evaluation

                                             ZigBee (Worst case)
      Operating        Max. Tune up Power               Antenna Gain             Power density
                                                                                                          Limit
       Mode                      (dBm)                 (dBi)        (num)          (mW/ cm2 )

       ZigBee                      12                  -0.42        0.908             0.0029                1


Note: the calculated distance is 20cm.




                                            END OF REPORT




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.



Document Created: 2019-05-14 22:41:26
Document Modified: 2019-05-14 22:41:26

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC