RF Exposure Info

FCC ID: 2AB2Q8ASSZAH0

RF Exposure Info

Download: PDF
FCCID_3954009

                                      FCC IC RF EXPOSURE REPORT

                                                            For

                                                   Motion Sensor

                                        MODEL NUMBER: 8ASSZAH0

                                          FCC ID: 2AB2Q8ASSZAH0

                                    REPORT NUMBER: 4788549790.1-2

                                          ISSUE DATE: July 16, 2018


                                     Prepared for
                         LEEDARSON LIGHTING CO., LTD.
   Xingda Road, Xingtai Industrial Zone, Changtai County, Zhangzhou City, Fujian
                                Province, P.R.China

                                    Prepared by
     UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
          Building 10, Innovation Technology Park, No. 1, Li Bin Road,
Song Shan Lake Hi-Tech Development Zone, Dongguan, People’s Republic of China
                              Tel: +86 769-22038881
                              Fax: +86 769 33244054
                              Website: www.ul.com




The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report
shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the
test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to
other similar products. This report does not imply that the product(s) has met the criteria for certification.


                                                                                           REPORT NO.: 4788549790.1-2
                                                                                                        Page 2 of 6



                                            TABLE OF CONTENTS
1.   ATTESTATION OF TEST RESULTS .................................................................................... 3

2.   TEST METHODOLOGY ........................................................................................................ 4

3.   FACILITIES AND ACCREDITATION .................................................................................... 4

4.   REQUIREMENT .................................................................................................................... 5




                                                          Page 2 of 6
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                                  .


                                                                                REPORT NO.: 4788549790.1-2
                                                                                             Page 3 of 6

1. ATTESTATION OF TEST RESULTS
Applicant Information
Company Name:                       LEEDARSON LIGHTING CO., LTD.
Address:                            Xingda Road, Xingtai Industrial Zone, Changtai County,
                                    Zhangzhou City, Fujian Province, P.R.China

Manufacturer Information
Company Name:                       LEEDARSON LIGHTING CO., LTD.
Address:                            Xingda Road, Xingtai Industrial Zone, Changtai County,
                                    Zhangzhou City, Fujian Province, P.R.China

EUT Description
Product Name:                       Motion Sensor
Model Name:                         8ASSZAH0
Sample Status:                      Normal
Date Tested:                        July 2~13, 2018

                                        APPLICABLE STANDARDS
                              STANDARD                                                 TEST RESULTS
                        FCC 47CFR§2.1091                                                  Complies
                       KDB-447498 D01 V06


Tested By:                                                      Checked By:




Kebo Zhang                                                     Shawn Wen
Engineer                                                       Laboratory Leader


Approved By:




Stephen Guo
Laboratory Manager


                                                   Page 3 of 6
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                                REPORT NO.: 4788549790.1-2
                                                                                             Page 4 of 6
2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with KDB 447498 D01
General RF Exposure Guidance v06.


3. FACILITIES AND ACCREDITATION
                        A2LA (Certificate No.: 4102.01)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with A2LA.
                        IAS (Lab Code: TL-702)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has demonstrated compliance with ISO/IEC Standard 17025:2005,
                        General requirements for the competence of testing and calibration
                        laboratories
                        FCC (FCC Designation No.: CN1187)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        Has been recognized to perform compliance testing on equipment subject
 Accreditation          to the Commission's Delcaration of Conformity (DoC) and Certification
 Certificate            rules
                        IC(Company No.: 21320)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been registered and fully described in a report filed with
                        Industry Canada. The Company Number is 21320.
                        VCCI (Registration No.: G-20019, R-20004, C-20012 and T-20011)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with VCCI, the
                        Membership No. is 3793.
                        Facility Name:
                        Chamber D, the VCCI registration No. is G-20019 and R-20004
                        Shielding Room B , the VCCI registration No. is C-20012 and T-20011

Note 1: All tests measurement facilities use to collect the measurement data are located at
Building 10, Innovation Technology Park, Song Shan Lake Hi tech Development Zone,
Dongguan, 523808, China

Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd.
Song Shan Lake Branch had been calibrated and compared to the open field sites and the test
anechoic chamber is shown to be equivalent to or worst case from the open field site.




                                                   Page 4 of 6
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                                REPORT NO.: 4788549790.1-2
                                                                                             Page 5 of 6




4. REQUIREMENT
LIMIT
Limits for General Population/Uncontrolled Exposure

                        Limits for General Population/Uncontrolled Exposure
                        Electric Field    Magnetic Field       Power                               Averaging Time
 Frequency Range                                                                                       2     2
                        Strength (E)     Strength (H)       Density (S)                             |E| , |H| or S
   (MHz)                                                             2
                          (V/m)             (A/m)           (mW/cm )                                  (minutes)
      0.3-1.34              614               1.63             (100)*                                      30
      1.34-30               824/f             2.19/f          (180/f2)*                                    30
       30-300               27.5              0.073               0.2                                      30
     300-1500                 --                --              f/150                                      30
  1500-100,000                --                --                1.0                                      30
Note 1: f = frequency in MHz, * means Plane-wave equivalent power density
Note 2: General population/uncontrolled exposures apply in situations in which the general
public may be exposed, or in which persons that are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or cannot exercise control over
their exposure.
Note 3: The limit value 1.0mW/cm2 is available for this EUT.


MPE CALCULATION METHOD

             2
S =PG/(4πR )


where: S = power density (in appropriate units, e.g. mW/ cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)




                                                   Page 5 of 6
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                                REPORT NO.: 4788549790.1-2
                                                                                             Page 6 of 6
CALCULATED RESULTS

Radio Frequency Radiation Exposure Evaluation
                                   Zigbee (Worst case)
      Operating   Max. Tune up Power       Antenna Gain                           Power density
                                                                                                          Limit
        Mode       (dBm)      (num)       (dBi)    (num)                           (mW/ cm2 )
        Zigbee              7            5.01           2.12         1.63             0.0016                1


   Note: the calculated distance is 20cm.




                                            END OF REPORT




                                                   Page 6 of 6
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .



Document Created: 2018-08-06 15:58:52
Document Modified: 2018-08-06 15:58:52

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC