RF Exposure

FCC ID: 2AB2Q6ZY-A806ST-Q1Z

RF Exposure Info

Download: PDF
FCCID_3108462

RF Exposure Evaluation for FCC ID: 2AB2Q6ZY-A806ST-Q1Z


Refer user manual this device is a LED lamp, and this device was designed used in portable devices
that the minimum distance between human’s body is 5mm. Based on the 47CFR 2.1093, this device
belongs to portable device. The definition of the category as following:

Portable Derives:
CFR Title 47 §2.1093(b)
(b) For purposes of this section, a portable device is defined as a transmitting device designed to
be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of
the user.
FCC KDB 447498 D01 General RF Exposure Guidance v06 Limit
Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or
body and 10-g extremity SAR evaluation for general population exposure conditions, by
measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion
Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-
based time-averaged maximum conducted output power of the RF channel requiring evaluation,
adjusted for tune-up tolerance, and the minimum test separation distance required for the
exposure conditions. The minimum test separation distance is determined by the smallest distance
from the antenna and radiating structures or outer surface of the device, according to the host
form factor, exposure conditions and platform requirements, to any part of the body or extremity
of a user or bystander.
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
  [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance,
mm)] · [√f(GHz) ] ≤ 3. for -g SAR and ≤ 7.5 for -g extremity SAR
 Where
• f (GHz) is the RF channel transmit frequency in GHz
• Power and distance are rounded to the nearest mW and mm before calculation
• The result is rounded to one decimal place for comparison

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
and
for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.

Peak Output Power
                                              Zigbee
                                                           Zigbee
        Mode
                               Channel 0                 Channel 8                 Channel 15
  Peak power (dBm)                8.33                      7.77                      7.79
Note: This report listed the maximal case Peak power value, please refer to RF test report for
more details.


          Mode                                Tune-up power range(dBm)
         Zigbee                                         8.0 +/- 0.5


FCC exclusion condition= [8.5 mW/5 mm] · [√2.405 GHz] = 2.6 < 3.0

RF Exposure Evaluation Result: Pass
Note: More power data, Please refer to the RF report.



Document Created: 2017-12-13 03:31:40
Document Modified: 2017-12-13 03:31:40

© 2024 FCC.report