1 Product Introduction


1.1 Basic Information

Arrival sensor integrated Z-Wave communication module to connect with Z-Wave gateway. By
real-time communication to verify if the device in the communication range of gateway, system can
automatically trigger some relative scenarios and send out messages to especial person.


1.2 System Diagram

                                                       Scenarios

      Arrival Sensor           Gateway


                                                        Router              MID*
*MID: Mobile Internet Device


1.3 Functions

       a)Particular design for low power consumption, battery charging cycle up to
          45 days
       b) High performance RF design, visual communication distance up to 30m
       c) Follow standard Z-Wave plus protocol
       d) Build-in an acceleration sensor to control device sleeping and awaking for
           power saving
       e)Conveniently operations to connect and reset by a button inside back cover
       f) LED indicator to show different status


1.4 Technical Parameter

1.4.1 Communication
           Module name                           6aB-SS-AG-C0
              Protocol                               Z-Wave
             Frequency                          908.42~916 MHz
        Communication Distance               About 40m indoors (LOS)
          Modulation Mode                       FSK(BFSK/GFSK)

1.4.2 Power Supply
           Operation Voltage                          3.3Vdc
               Current                               37mA/3s
Leedarson Lighting


          Max. Power Consumption                          About 120mW
                  Standby Power                           22uA in Average


1.4.3   Battery
                   Battery Type                           150mAh Li—Poly
                  Charging Cycle                             <45 days


1.4.4   Condition
        Storage environment:                   —5—45°C,     <90%, non—condensing
        Operational temperature:                              0—40°C




2 Hardware Specification


    2.1 Structure


        Dimensions: 43mm (H) *34mm (W) *16mm (D)
        Weight: 30¢
        Material: PC


2.2 Functional Description

2.2.1 Total Introduction



                                                                                       Hanger


                                                                            Charging Interface (Micro USB)


                                                                                    Reset Button


                                                                                  Charging Indicator


                                                                             Connection Status Indicator




2.2.2 Reset Button
Reset and Connection button built—in back cover and used for connecting and removing with gateway.
Operation mode as following:
           Connection             Turn on researching function in APP, short press button to add in
                                   Z—Wave system.
              Reset               Hold on pressing button for 5 seconds, device reset to factory


Leedarson Lighting


                             mode.


2.2.3 LED Indicator
  LED indicator embedded in internal PCBA and support red/yellow colors to display different status
  of devices.
         Connecting   Red indicator quickly flash for 3 times, if successfully connected, red
                      indicator hold on for 3 seconds.
         Connected    Red indicator keep on for 3s.
          Resetting   Red indicator slowly flash for 2 times.
          Charging    Blue indicator quickly flash until full charged.
         Low Power    Blue indicator slowly flash, about 2 minutes once




 2.3 Product Operation

2.3.1 Product Charging
Open the soft cover inside product and plug in Micro USB interface and connect to power supply. If
blue indicator quickly flash, the product turned into charging mode.

2.3.2 Connecting
Use APP or special button in gateway to turn on searching function. While gateway waiting for
connection, short press Reset button to connect. Check the status of LED indicator as the sheet
       above.

2.3.3 Reset
Hold on pressing Reset button for 5 seconds and check the status of LED indicator as the sheet above.

2.3.4 Working Mechanism
1. Sleeping and awaking of arrival sensor is based on integrated acceleration detector. If acceleration
   detector had not triggered for 2.5 minutes, arrival sensor send out a package to gateway and go to
   sleep mode. While acceleration sensor triggered, arrival sensor wake up and communication with
   gateway immediately.

2. If arrival sensor send out a Heartbeat package and not get reply from gateway, system judge arrival
    sensor as user left to trigger relative scenarios and send out message.

3. If arrival sensor send out a Heartbeat package and get reply at once from gateway, system judge
   arrival sensor as user back to trigger relative scenarios and send out message.




Leedarson Lighting


   Goer
           ue




                           Rbrnturon         \
                                                                                Power Measure
  Pume              Hetteton ooz titntemy        neurcatotpe«ountcisn
  Arie               Ernttives bosttornean       Evnttioes t02time trid
  Seras                                                                                  Low Power
           Emewer
 Gntemy
           Bmz           p—————                                 (teme)           (Worig)
Caution:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept any
interference received,including interference that may cause undesired operation.
FCC Caution:
Changes or modifications not expressly approved by the part responsible for compliance could void
the user‘s authority to operate the equipment.
FCC Statement:
"This equipment has been tested and found to comply               the limits for a Class 8 digtal device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residentlal installation. This eqtuipment generates, uses and can
radiate radio frequency energy and, not installed and used in accordance with the instru ns, may
cause harmful interference. to radio. communications. However, there is no. quarantee: that
interference will not occur in a particalar Installation: If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver
—Connect the equipment into an outlet on a circult different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help."
Leedarson Lighting



Document Created: 2017-09-04 15:29:31
Document Modified: 2017-09-04 15:29:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC