14_ZAP 1L-Tx TestRpt DSC r4

FCC ID: 2AB22ZAP-5LX-S

Test Report

Download: PDF
FCCID_4389176

                                         Test Report

                                    FCC ID: 2AB22ZAP-5LX-S


                                    Date of issue: Aug. 07, 2019



     Report Number:                          MTi19071009-1E1


     Sample Description:                     ZAP remote


     Model(s):                               ZAP 1L-Tx


     Applicant:                              Etekcity Corporation


     Address:                                1202 N Miller St. Suite A, Anaheim, CA 92806, USA


     Date of Test:                           July 11, 2019 to Aug. 07, 2019




                                        Shenzhen Microtest Co., Ltd.
                                          http://www.mtitest.com




This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen
Microtest Co., Ltd.

Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                                              - Page 2 of 21 -                                   Report No.: MTi19071009-1E1


                                                                     Table of Contents

1       GENERAL DESCRIPTION ..................................................................................................................................... 4
    1.1     DESCRIPTIONS OF EUT ............................................................................................................................................... 4
    1.2     OPERATION CHANNEL LIST ........................................................................................................................................... 4
    1.3     FREQUENCY CHANNEL UNDER TEST .............................................................................................................................. 4
    1.4     ANCILLARY EQUIPMENT LIST ......................................................................................................................................... 4
    1.5     DESCRIPTION OF SUPPORT UNITS ................................................................................................................................. 4
2       SUMMARY OF TEST RESULTS ............................................................................................................................. 5
3       TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 6
    3.1     TEST LABORATORY...................................................................................................................................................... 6
    3.2     ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 6
    3.3        MEASUREMENT UNCERTAINTY ................................................................................................................................. 6
    3.4     TEST SOFTWARE ........................................................................................................................................................ 6
4       EQUIPMENT LIST ............................................................................................................................................... 7
5       TEST RESULT ...................................................................................................................................................... 8
    5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 8
       5.1.1    Requirement defined in FCC 15.203 ............................................................................................................ 8
       5.1.2    EUT antenna description ............................................................................................................................. 8
    5.2      AC POWER LINE CONDUCTED EMISSION .................................................................................................................... 9
       5.2.1    Limit ............................................................................................................................................................ 9
       5.2.2    Test method ................................................................................................................................................ 9
       5.2.3    Test Result ................................................................................................................................................... 9
    5.3      FIELD STRENGTH OF FUNDAMENTAL AND HARMONIC EMISSIONS ................................................................................. 10
       5.3.1    Limits ......................................................................................................................................................... 10
       5.3.2    Test Method .............................................................................................................................................. 11
       5.3.3    Test Result ................................................................................................................................................. 12
    5.4      OCCUPIED BANDWIDTH....................................................................................................................................... 13
       5.4.1    Test method .............................................................................................................................................. 13
       5.4.2    Test result.................................................................................................................................................. 14
    5.5      RADIATED EMISSION AND BAND EDGE SPURIOUS EMISSION ....................................................................................... 15
       5.5.1    Limit .......................................................................................................................................................... 15
       5.5.2    Test method .............................................................................................................................................. 15
       5.5.3    Test Result ................................................................................................................................................. 15
    5.6      TRANSMITTER TIMEOUT ...................................................................................................................................... 19
       5.6.1    Limit .......................................................................................................................................................... 19
       5.6.2    Test method .............................................................................................................................................. 19
       5.6.3    Test Result ................................................................................................................................................. 19
PHOTOGRAPHS OF THE TEST SETUP ...........................................................................................................................20
PHOTOGRAPHS OF THE EUT .......................................................................................................................................21




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 3 of 21 -                     Report No.: MTi19071009-1E1


                              Test Result Certification

Applicant’s name:                       Etekcity Corporation


Address:                                1202 N Miller St. Suite A, Anaheim, CA 92806, USA


Manufacture's Name:                     Dongguan Raiwee Electronic Technology Co., Ltd

                                        Building 11, Antouling, Industry Avenue, Qinghu Village, Qishi
Address:                                Town, Dongguan, Guangdong 523000, China


Product name:                           ZAP remote


Trademark:                              ETEKCITY


Model name:                             ZAP 1L-Tx


Standards:                              FCC Part 15.231

                                        ANSI C63.10-2013
Test Procedure:                         DA 00-705

This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that
the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested
sample identified in the report.


                  Tested by:

                                                    Jone Lee                                       Aug. 07, 2019

                 Reviewed by:

                                                    Blue Zheng                                     Aug. 07, 2019

               Approved by:

                                                    Smith Chen                                      Aug. 07, 2019




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                         - Page 4 of 21 -                    Report No.: MTi19071009-1E1


1 General description
1.1 Descriptions of EUT

    Product name:                         ZAP remote

    Model name:                           ZAP 1L-Tx

    Series model:                         N/A

    Difference of series model: N/A

    Tx/Rx frequency range:                Tx:433.92MHz

    Modulation type:                      ASK

    Power source:                         DC 12V from battery

    Adapter information:                  N/A

    Antenna designation:                  PCB Antenna(Antenna Gain:1dBi )

    Hardware version:                     V1.0.1

    Software version:                     V1.0

1.2 Operation channel list
                              Channel                                                   Frequency
                                  1                                                     433.92MHz


1.3 Frequency Channel Under Test
                              Channel                                                  Frequency
                                 1                                                     433.92MHz

1.4 Ancillary equipment list
            Equipment                        Model                           S/N                     Manufacturer
                  /                              /                               /                           /

1.5 Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
     Item         Equipment                    Brand              Model/Type No. Series No.                       Note
        /                 /                          /                       /                       /
        /                 /                          /                       /                       /
Note:
  (1)The support equipment was authorized by Declaration of Confirmation.
  (2)For detachable type I/O cable should be specified the length in cm in『Length』column.



Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 5 of 21 -                     Report No.: MTi19071009-1E1


2 Summary of Test Results
Test procedures according to the technical standards:

      Item        FCC Part No.                   Description of Test                      Result               Remark

        1              15.203                  Antenna requirement                         Pass
                                            AC power line conducted
        2              15.207                                                               N/A
                                                     emission
                                          Field strength of fundamental
        3            15.231(b)                                                             Pass
                                            and harmonic emissions
                    15.205 and               Radiated emission and
        4                                                                                  Pass
                      15.209                        bandedge
        5              15.215                   Occupied Bandwidth                         Pass

        6          15.231(a)(2)                      Release time                          Pass

    The meaning of symbols: “ZAP 1L-Tx ” – Not Applicable




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 6 of 21 -                     Report No.: MTi19071009-1E1


3 Test Facilities and Accreditations
3.1 Test laboratory
     Test Laboratory                   Shenzhen Microtest Co., Ltd
                                       No.102A & 302A, East Block, Hengfang Industrial Park,
     Location                          Xingye Road, Xixiang, Bao'an District, Shenzhen,
                                       Guangdong, China
     FCC Registration
                                       448573
     No.:

3.2 Environmental conditions
     Temperature:                      15ºC~35ºC
     Humidity                          20%~75%
     Atmospheric
                                       98kPa~101kPa
     pressure

3.3 Measurement uncertainty
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on
a standard uncertainty multiplied by a coverage factor of k=2,providing a level of
confidence of approximately 95 %
     RF frequency                                                1 x 10-7
     RF power, conducted                                         ±1.38dB
     Conducted emission(150kHz~30MHz)                            ±0.21dB
     Radiated emission(30MHz~1GHz)                               ±4.68dB
     Radiated emission (above 1GHz)                              ±4.89dB
     Temperature                                                 ±0.5°C
     Humidity                                                    ±2 %

3.4 Test software

         Software
                                     Manufacturer                            Model                            Version
           Name
                                      Shenzhen JS
      RF Test System                                                        JS1120-3                        2.5.77.0418
                                    tonscend co., ltd




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                          - Page 7 of 21 -                    Report No.: MTi19071009-1E1


4 Equipment list
 Equipment                                   Manufactu                               Serial       Calibration
                  Equipment Name                                   Model                                            Due date
    No.                                         rer                                   No.            date
                                             Rohde&sch
   MTI-E004       EMI Test Receiver                                ESPI7             100314        2018/10/09       2019/10/08
                                               warz
                  TRILOG Broadband
   MTI-E006                                  schwarabeck         VULB 9163          9163-872       2018/10/15       2020/10/14
                  Antenna
                                             Hewlett-Pac                          3113A0615
   MTI-E014       amplifier                                        8447D                           2018/10/09       2019/10/08
                                                kard                                  0
                  Single path vehicle        Schwarzbec
   MTI-E036                                                      NNBM 8124           01175         2018/10/09       2019/10/08
                  AMN(LISN)                      k
                  Low noise active
                                             Schwarzbec
   MTI-E038       vertical monopole                              VAMP 9243            #565         2018/10/16       2019/10/15
                                                 k
                  antenna

                                             Schwarzbec
   MTI-E039       Biconical antenna                               BBA 9106            #164         2018/10/15       2019/10/14
                                                 k

                  MXG Vector Signal                                                MY490604
   MTI-E041                                     Agilent            N5182A                          2019/04/16       2020/04/15
                  Generator                                                           55
                  ESG Series Analog                                                GB400512
   MTI-E042                                     Agilent            E4421B                          2019/05/21       2020/05/20
                  signal generator                                                    40
                  Thermometer clock
   MTI-E044                                        -               HTC-1                /          2019/04/17       2020/04/16
                  humidity monitor
                                             Schwarzbec
   MTI-E062       Log Periodic Antenna                          VUSLP 9111B           #312         2018/04/11       2020/04/10
                                                 k
                  Log Periodic Dipole        ETS-LINDG
   MTI-E063                                                        3148B           00224524        2018/04/11       2020/04/10
                  Array Antenna                 REN

   MTI-E065       Amplifier                    EMtrace             RP06A             00117         2019/04/29       2020/04/28

                  Comprehensive test         Rohde&sch
   MTI-E066                                                       CMW500             149155        2019/04/16       2020/04/15
                  instrument                   warz
                                                                                   MY513502
   MTI-E071       PXA Signal Analyzer           Agilent            N9030A                          2018/10/25       2019/10/24
                                                                                      96
                                             Rohde&sch
   MTI-E076       EMI Test Receiver                                ESIB26            100273        2019/04/16       2020/04/15
                                               warz
                                                                                  3610A0195
   MTI-E078       Synthesized Sweeper           Agilent            83752A                          2019/04/16       2020/04/15
                                                                                      7
                                                                                   MY400276
   MTI-E079       DC Power Supply               Agilent            E3632A                          2019/04/16       2020/04/15
                                                                                      95
                  Artificial mains                                                 ES391180
   MTI-E093                                     3ctest            LISN J50                         2019/04/16       2020/04/15
                  network                                                             5
                                            Space-Dtroni EWLNA0118G-
   MTI-E096       Power amplifier                                                1852001         2019/04/29       2020/04/28
                                                   ccs              P40
                                               SOLAR
  MTI-E097        Current Probe              ELECTRONI            9207-1         220095-1        2019/04/17       2020/04/16
                                               CS CO.
                                               SOLAR
  MTI-E098        Loop Sensor                ELECTRONI            7334-1         220095-2        2019/04/21       2020/04/20
                                               CS CO.
 Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to international
 system unit (SI).




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 8 of 21 -                     Report No.: MTi19071009-1E1


5 Test Result
5.1 Antenna requirement
5.1.1      Requirement defined in FCC 15.203
     An intentional radiator shall be designed to ensure that no antenna other than that furnished by
the responsible party shall be used with the device. The use of a permanently attached antenna or
of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
comply with the provisions of this section. The manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector
is prohibited. This requirement does not apply to carrier current devices or to devices operated
under the provisions of §15.211, §15.213, §15.217, §15.219, or §15.221. Further, this requirement
does not apply to intentional radiators that must be professionally installed, such as perimeter
protection systems and some field disturbance sensors, or to other intentional radiators which, in
accordance with §15.31(d), must be measured at the installation site. However, the installer shall be
responsible for ensuring that the proper antenna is employed so that the limits in this part are not
exceeded.
5.1.2      EUT antenna description
The radio antenna of EUT is a PCB antenna, the maximum gain is 1dBi. So the antenna meets the
requirement of this part.




                                                 PCB Antenna




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 9 of 21 -                     Report No.: MTi19071009-1E1


5.2 AC power line conducted emission
5.2.1      Limit

                          Frequency                                                        Limit
                            (MHz)                                       Quasi-peak                      Average
                            0.15-0.5                                      66 to 56                      56 to 46
                              0.5-5                                          56                             46
                              5-30                                           60                             50

Note: Decreases with the logarithm of the frequency from 0.15MHz to 0.5MHz.
5.2.2      Test method
1. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to
the power mains through a line impedance stabilization network (LISN). All other support equipment
powered from additional LISN(s). The LISN provide 50 Ohm/50uH of coupling impedance for the
measuring instrument.
2. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
forth in the center forming a bundle 30 to 40 cm long.
3. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall length
shall not exceed 1 m.
4. LISN is at least 80 cm from nearest part of EUT chassis.
5. The resolution bandwidth of EMI test receiver is set at 9kHz.
5.2.3      Test Result


Note: The device is a DC power supply and does not apply to conducted emissions.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 10 of 21 -                    Report No.: MTi19071009-1E1




5.3 Field strength of fundamental and harmonic emissions
5.3.1      Limits
Intentional radiators may operate at a periodic rate exceeding that specified in paragraph (a) of this
section and may be employed for any type of operation, including operation prohibited in paragraph
(a) of this section, provided the intentional radiator complies with the provisions of paragraphs (b)
through (d) of this section, except the field strength table in paragraph (b) of this section is replaced
by the following:

        Fundamental frequency               Field strength of fundamental                Field strength of spurious
                (MHz)                             (microvolts/meter)                    emissions (microvolts/meter)
             40.66-40.70                                 2.250                                       225
               70-130                                    1.250                                       125
                                                     1                                           1
               130-174                                1250 to 3750                                125 to 375
               174-260                                   3.750                                       375
                                                    1                                           1
               260-470                               3750 to 12500                               375 to 1250
              Above 470                                 12500                                       1250
1
Linear interpolations.
For example for 433.925MHz

                      uV/m


                      12500




                       3750




                                         260                EUT frequency(X)      470
                                                                                             Frequency (MHz)



The Field Strength of Fundamental Emissions (Operating Frequency) is:
      3750 uV/m = 20*log (3750) dBuV/m = 71.48 dBuV/m
      12500 uV/m = 20*log (12500) dBuV/m = 81.94 dBuV/m


      For example the Fundamental emission is 433.925MHz, the limit is X.
      (433.92-260)/(470-260)=(X-3750)/(12500-3750)
                                         173.925/210 =(X-3750)/8750
                                                      X = 10996.875uV/m
      AV Limit = 20*log (10996.875) dBuV/m = 80.83 dBuV/m
      PK Limit = 100.83 dBuV/m




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 11 of 21 -                    Report No.: MTi19071009-1E1


5.3.2      Test Method
1. The EUT is placed on a turntable, which is 0.8m above ground plane for test frequency range
blew 1GHz, and 1.5m above ground plane for test frequency range above 1GHz.
2. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the
highest emissions.
3. Use the following spectrum analyzer settings:
         Span = wide enough to fully capture the emission being measured
         RBW = 1 MHz for f ≥ 1GHz
         RBW = 100 kHz for f < 1 GHz
         VBW ≥ RBW
         Sweep = Auto
         Detector function = Peak
         Trace = max hold
4. Follow the guidelines in ANSI C63.4-2014 with respect to maximizing the emission by rotating the
EUT, adjusting the measurement antenna height and polarization, etc. The peak reading of the
emission, after being corrected by the antenna factor, cable loss, pre-amp gain, etc., is the peak
field strength, submit this data. Each emission was to be maximized by changing the polarization of
receiving antenna both horizontal and vertical.
5. The peak level, once corrected, must comply with the limit specified in Section 15.209. Set the
spectrum to
      RBW = 1MHz
      VBW = 10Hz
      Detector = PK for AV value, while maintaining all of the other instrument settings




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 12 of 21 -                    Report No.: MTi19071009-1E1

5.3.3      Test Result

   Field Strength of Fundamental Emissions and Field strength of spurious emissions Value

                                    Field
 Operating Frequency                                                  Limit @3m           Margin
                                   Strength           Detector                                                 Antenna
        (MHz)                                                          (dBuV/m)            (dB)
                                  (dBuV/m)
                                    78.26              Peak              100.83            22.57               Vertical
                                     67.8             Average            80.83             13.03               Vertical
          433.920
                                    79.52              Peak              100.83            21.31              Horizontal
                                    69.06             Average            80.83             11.77              Horizontal
                                    54.34              Peak              80.83             26.49               Vertical
                                    43.88             Average            60.83             16.95               Vertical
         869.1301
                                    53.45              Peak              80.83             27.38              Horizontal
                                    42.99             Average            60.83             17.84              Horizontal

Note: If the PK measured values lower than average mode limit, the EUT shall be deemed to meet
average limits and then no additional average mode measurement performed.

Note: 1. EUT Pre-scan X/Y/Z orientation, only worst case is presented in the report(Y
orientation).
 2. *Calculate Average value based on Duty Cycle correction factor:
         Duty Cycle=Ton/(Ton+Toff)= 225ms/750ms = 0.3=30%
         Duty Cycle factor= 20lg (Duty Cycle) =20lg (0.3) = -10.46dB
         Average=Peak+ Duty Cycle factor
3. Margin: Limit- Field Strength
                                                        433.92MHz




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 13 of 21 -                    Report No.: MTi19071009-1E1

5.4 Occupied Bandwidth
5.4.1      Test method
        Use the following spectrum analyzer settings:
            Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
            RBW ≥1% of the 20 dB bandwidth
            VBW ≥RBW
            Sweep = auto
            Detector function = peak
            Trace = max hold
The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta
function to measure 20 dB down one side of the emission. Reset the marker-delta function, and
move the marker to the other side of the emission, until it is (as close as possible to) even with the
reference marker level. The marker-delta reading at this point is the 20 dB bandwidth and 99%
occupied bandwidth of the emission.
The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the emission
shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the points 20 dB
down from the modulated carrier




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 14 of 21 -                    Report No.: MTi19071009-1E1



5.4.2      Test result
Test modulation: ASK
                                                                       99% occupied                       Limits(MHz)
                                     20dB emission
   Frequency (MHz)                                                       bandwidth
                                    bandwidth (MHz)
                                                                           (MHz)
          433.92                           0.4192                         0.73856                              1.08

Test plots as below

                                                        433.92MHz




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 15 of 21 -                    Report No.: MTi19071009-1E1



5.5 Radiated emission and Band edge spurious emission
5.5.1      Limit
Emissions radiated outside of the specified frequency bands, except for harmonic emissions,
(b)shall be attenuated by at least 50 dB below the level of the fundamental emissions or to the
general field strength limits listed in RSS-Gen, whichever is less stringent.
                                                  Field               Field
                Frequency                                                                                Measurement
                                                strength            strength            Detector
                  (MHz)                                                                                    distance
                                                 μV/m               dBμV/m
                    30-88                          100                 40                   QP
                    88-216                         150                 43.5                 QP
                   216-960                         200                  46                  QP
                                                                                                                3m
                   960-1000                        500                  54                  QP
               Above 1000                          500                  54                  AV
               Above 1000                         5000                  74                  PK

5.5.2      Test method
1. The EUT is placed on a turntable, which is 0.8m above ground plane for test frequency range
blew 1GHz, and 1.5m above ground plane for test frequency range above 1GHz.
2. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the
highest emissions.
3. Use the following spectrum analyzer settings:
      Span = wide enough to fully capture the emission being measured
      RBW = 1 MHz for f ≥ 1GHz
      100 kHz for f < 1 GHz, VBW ≥ RBW
      Sweep = auto
      Detector function = peak
      Trace = max hold
4. Follow the guidelines in ANSI C63.4-2014 with respect to maximizing the emission by rotating the
EUT, adjusting the measurement antenna height and polarization, etc. The peak reading of the
emission, after being corrected by the antenna factor, cable loss, pre-amp gain, etc., is the peak
field strength, submit this data. Each emission was to be maximized by changing the polarization of
receiving antenna both horizontal and vertical.
5. The peak level, once corrected, must comply with the limit specified in Section 15.209. Set the
RBW = 1MHz, VBW = 10Hz, Detector = PK for AV value, while maintaining all of the other
instrument settings.
5.5.3      Test Result
Remark:
If the PK measured values lower than average mode limit, the EUT shall be deemed to meet
average limits and then no additional average mode measurement performed.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 16 of 21 -                    Report No.: MTi19071009-1E1


Radiated emission
Between 30MHz – 1GHz
 EUT:           ZAP remote                                         Model Name :               ZAP 1L-Tx
 Relative
                52%                                                Phase:                     H
 Humidity:
 Pressure:      1010 hPa                                           Test Voltage :             DC 12V from battery
 Test Mode : TX




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 17 of 21 -                    Report No.: MTi19071009-1E1


  EUT:                    ZAP remote                               Model Name :               ZAP 1L-Tx
  Relative
                          52%                                      Phase:                     V
  Humidity:
  Pressure:               1010 hPa                                 Test Voltage :             DC 12V from battery
  Test Mode :             TX




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 18 of 21 -                    Report No.: MTi19071009-1E1


1G-6GHz

                                  Meter                          Emission
                Frequency        Reading           Factor         Level          Limits        Margin         Polar
     No.          (MHz)           (dBuV)            dB)          (dBuV/m)      (dBuV/m)         (dB)          (H/V)
                 1355.738          43.29           -9.96           33.33           74          -40.67       Horizontal
      1
      2          2070.131          44.93           -9.17           35.76           74          -38.24       Horizontal
      3          3157.061          44.72           -9.25           35.47           74          -38.53       Horizontal
      4          3852.211          42.99           -9.04           33.95           74          -40.05       Horizontal
      5          4902.902          47.67           -9.96           37.71           74          -36.29       Horizontal
      6          5613.507          43.62           -9.65           33.97           74          -40.03       Horizontal
                 1526.384          47.79           -9.77           38.02           74          -35.98        Vertical
      1
      2          2202.488          48.04           -9.93           38.11           74          -35.89        Vertical
      3          3053.802          47.59           -9.10           38.49           74          -35.51        Vertical
      4          3928.957          46.41           -9.90           36.51           74          -37.49        Vertical
      5          5199.723          52.55           -9.11           43.44           74          -30.56        Vertical
      6          5680.524          49.41           -9.87           39.54           74          -34.46        Vertical



Note1 : Absolute Level = Reading Level+ Factor, Margin= Absolute Level- Limit, Factor = Antenna Factor + Cable Loss –
Pre-amplifier.
Note2 :The peak value is less than the AV value, AV value is not required Factor added by measurement software
automatically.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 19 of 21 -                    Report No.: MTi19071009-1E1


5.6 Transmitter timeout
5.6.1      Limit
15.231 (a)(1)A manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.
5.6.2      Test method
      Setup the EUT as show in the block diagram above.
      Set Spectrum Analyzer
            Centre Frequency = Fundamental Frequency
            RBW=100 kHz, VBW= 300 kHz
            Span= 0 Hz
            Sweep Time= 10 Seconds.
            Setup the EUT as normal operation and press Transmitter button
      Release the button, use Delta Mark function to test the time.
5.6.3      Test Result

  Periodic operation time (s)                           Limit(s)                                    Result

                0.24                                        5                                        Pass




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 20 of 21 -                    Report No.: MTi19071009-1E1


Photographs of the Test Setup
                                          Radiated emission – below 1GHz




                                          Radiated emission – above 1GHz




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 21 of 21 -                    Report No.: MTi19071009-1E1


     Photographs of the EUT
See the APPENDIX 1: EUT PHOTO in the report No.: MTi19071009-1E1-1



                                                 ----End of Report----




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China



Document Created: 2019-08-07 18:35:43
Document Modified: 2019-08-07 18:35:43

© 2024 FCC.report