Test report

FCC ID: 2AB22-ZAP1FXT

Test Report

Download: PDF
FCCID_3342373

                                    Test Report

                                    FCC ID.: 2AB22-ZAP1FXT


                                    Date of issue: Mar. 15, 2017



     Sample Description:                             Etekcity Outdoor Remote Control Outlet Transmitter


     Model(s):                                       ZAP 1FXT


     Applicant:                                      Etekcity Corporation


     Address:                                        1202 N Miller St. Suite A, Anaheim, CA 92806


     Date of Test:                                   Feb.28, 2017 to Mar. 15, 2017




                                        ShenzhenMicrotest Co., Ltd.
                                          http://www.mtitest.com




This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen
Microtest Co., Ltd..

Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                                   - Page 2of 12-               Report No.: MTi170228E061


                                               TABALE OF CONTENTS
TABALE OF CONTENTS ............................................................................................................. 2
1. General description ............................................................................................................... 5
1.1 Feature of equipment undertest (EUT)................................................................................ 5
1.2 operation channel list ........................................................................................................... 5
2. Test Configuration of EUT .................................................................................................... 6
2.1EUT operation mode .............................................................................................................. 6
2.2Testconditions........................................................................................................................ 6
2.3Testing site ............................................................................................................................. 6
2.4Ancillary equipment list ........................................................................................................ 6
2.5 Measurement uncertainty .................................................................................................... 6
3. List of test equipment ........................................................................................................... 7
4. Test Result ............................................................................................................................. 8
4.1Antenna requirement ............................................................................................................. 8
4.220dB emission bandwidth ..................................................................................................... 9
4.3Radiated emission ............................................................................................................... 10
4.4Time of occupancy (dwell time) .......................................................................................... 12




This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen
Microtest Co., Ltd..

Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                              - Page 3of 12-           Report No.: MTi170228E061


TEST RESULT CERTIFICATION


Applicant’s name:                            Etekcity Corporation
Address:                                     1202 N Miller St. Suite A, Anaheim, CA 92806
Manufacture's Name:                          SHENZHEN SANCING TECHNOLOGY CO;LTD
                                             Room301, A Block Tus Technology Park Jianmin road Long
Address:
                                             gang District Shenzhen China
Product description
Product name:                                Etekcity Outdoor Remote Control Outlet Transmitter
Trademark:                                   Etekcity
Model name:                                  ZAP 1FXT
Serial Model:                                /
Standards:                                   FCC Part 15 C
Test Procedure:                              ANSI C63.4-2014;ANSI C63.10-2013

This device described above has been tested by Shenzhen Microtest Co.,Ltd. and the test results
show that the equipment under test (EUT) is in compliance with the FCCrequirements. And it is
applicable only to the tested sample identified in the report.




                 Tested by:

                                                              Sangdi Huang                                Mar. 15, 2017

               Reviewed by:

                                                              Leon Chen                                   Mar. 15, 2017

              Approved by:

                                                              Tom Xue                                     Mar. 15, 2017




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                              - Page 4of 12-           Report No.: MTi170228E061



                                    SUMMARY OF TEST RESULT

        Item        FCC Part No.                            Description of Test                                Result

          1         15.203                                  Antenna requirement                                 Pass
                                                            AC power line conducted
          2         15.207                                                                                       N/A
                                                            emission
          3         15.231(c)                               20dB bandwidth                                      Pass

          4         15.231(b)                               Radiated emission                                   Pass

          5         15.231(a)(1)                            Release time                                        Pass




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                              - Page 5of 12-           Report No.: MTi170228E061


1. General description
1.1 Feature of equipment undertest (EUT)

    Product name:                         Etekcity Outdoor Remote Control Outlet Transmitter

    Model name:                           ZAP 1FXT

    Tx/Rx frequency range:                Tx:433.92MHz

    Modulation type:                      ASK
    Power source:                         DC 12V/23A (ALKALINE BATTERY)

    Antenna designation:                  PCBA antenna
    Antenna Gain:                          0dBi

1.2 operation channel list
                            Channel                                                    Frequency
                                 1                                                     433.92MHz




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                              - Page 6of 12-           Report No.: MTi170228E061


2. Test Configuration of EUT
2.1EUT operation mode
During testing, the EUT is operated in TX mode. (new battery is used during all test)
2.2Testconditions
During the measurement the environmental conditions were within the listed ranges:
    - Temperature: 20ºC~30ºC
    - Humidity: 30%~70%
    - Atmospheric pressure: 98kPa~101kPa
2.3Testing site

     Test Site                        Shenzhen Toby Technology Co., Ltd.
                                      1 A/F., Bldg.6, Yusheng Industrial Zone The National Road
     Test Site Location
                                      No.107 Xixiang Section 467
     FCC Registration
                                      811562
     No.:
2.4Ancillary equipment list
           Equipment                         Model                          S/N                     Manufacturer
                  /                             /                             /                              /

2.5 Measurement uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     RF frequency                                                1 x 10-7
     RF power, conducted                                         ± 1 dB
     Conducted emission(150kHz~30MHz)                            ± 2.5 dB
     Radiated emission(30MHz~1GHz)                               ± 4.2 dB
     Radiated emission (above 1GHz)                              ± 4.3 dB
     Temperature                                                 ±1 degree
     Humidity                                                    ±5 %




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                              - Page 7of 12-           Report No.: MTi170228E061


3. List of test equipment
 For RF conducted test:

          Equipment                 Manufacturer                Model             Serial No.         Calibration Due
       Signal Analyzer                  Agilent               N9010A            MY48030494                2017/11/4
    4 Ch. Simultaneous
    Sampling 14 Bits 2                  Agilent               U2531A           TW54063513                 2017/11/4
           MS/s
    X-series USB Peak
    and Average Power                   Agilent              U2021XA            MY54080019                2017/11/4
          Sensor
       vector Signal
                                        Agilent               E4438C            US44271917                2017/11/4
        Generator
       vector Signal
                                        Agilent               E4438C            MY49070163                2017/11/4
        Generator
      Dc Power Supply                     GW                GPR-6030D                   /                 2017/11/4
      Temperature &
                                  GIANT FORCE                GTH-056P           GF-94454-1                2017/11/4
     Humitidy Chamber

For Radiated emission:

          Equipment                 Manufacturer                Model             Serial No.         Calibration Due
     Broadband TRILOG
                                    Schwarabeck              VULB9163              9163-872              2017/11/14
          Antenna
         Horn Antenna               Schwarzbeck            BBHA 9120 D           9120D-1145              2017/11/14

            Amplifier                     HP                    8447D            3113A06150               2017/11/4

            Amplifier                   Agilent                 8449B            3008A02400               2017/7/4

         Test Receiver              Schwarabeck                 ESPI7               100314                2017/11/4

      Spectrum analyzer                 Agilent                E4407B           MY41441082                2017/11/4

       Signal Generator                   R&S                  SMT 06            832080/007               2017/11/4

Note: the calibration interval of the above test instruments is 12 months and the calibrations are
traceable to international system unit (SI).




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                              - Page 8of 12-           Report No.: MTi170228E061


4. Test Result
4.1Antenna requirement
4.1.1Requirement defined in FCC 15.203
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
comply with the provisions of this section. The manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector
is prohibited. This requirement does not apply to carrier current devices or to devices operated
under the provisions of §15.211, §15.213, §15.217, §15.219, or §15.221. Further, this requirement
does not apply to intentional radiators that must be professionally installed, such as perimeter
protection systems and some field disturbance sensors, or to other intentional radiators which, in
accordance with §15.31(d), must be measured at the installation site. However, the installer shall be
responsible for ensuring that the proper antenna is employed so that the limits in this part are not
exceeded.
4.1.2EUT antenna description
The radio antenna of EUT is an internal permanently attached antenna, the maximum gain is 0 dBi.
So the antenna meets the requirement of this part.




                                                                                                         Antenna




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                                                 - Page 9of 12-                                Report No.: MTi170228E061


4.2 20dB emission bandwidth
4.2.1 Limits
The bandwidth of the emissions shall be no wider than 0.25% of the center frequency
for devices operating above 70MHz and below 900MHz. So the emission bandwidth limits have
been calculated in below table.

                      Fundamental Frequency                                                    20 dB Bandwidth Limits (MHz)
                                     433.92MHz                                                                                1.0848

4.2.2 Testmethod
Set Spectrum Analyzer centre Frequency= Fundamental Frequency, RBW=10 kHz, VBW= 30
kHz, Span= 1 MHz
Allow the trace to stabilize, measure the maximum width of the emission that is constrained by the
frequencies associated withthe two outermost amplitude points (upper and lower frequencies) that
are attenuated by 20 dBrelative to the maximum level measured in the fundamental emission.
4.2.3Test result


                 Frequency
                                                          20dB Bandwidth (MHz)                                                                Result
                   (MHz)
                    433.92                                                      0.122                                                         PASS
                                                                                * RBW   10    kHz   Marker      1   [T1   ]
                                                                                * VBW   30    kHz                     73.27    dBµV
                               Ref   90   dBµV           * Att   10   dB        * SWT   300    ms         433.954000000           MHz

                               90                                                                   ndB    [T1]        20.00      dB
                                                                                                    BW    122.000000000           kHz
                                                                                                    Temp    1   [T1    ndB]              A
                               80
                                                                                 1                                    53.81    dBµV
                        1 PK
                                                                                                          433.893000000           MHz
                        MAXH
                               70                                                                   Temp    2   [T1    ndB]
                                                                                                                      53.05    dBµV
                                                                                                          434.015000000           MHz   TDF
                               60
                                                                           T1           T2

                               50



                               40


                                                                                                                                        3DB
                               30



                               20



                               10



                               0


                               -10

                               Center     433.92   MHz                 100      kHz/                                  Span    1   MHz




                        Date: 14.MAR.2017            02:33:05




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                             - Page 10of 12-           Report No.: MTi170228E061


4.3Radiated emission
4.3.1 Limit
In addition to the provisions of Section 15.205, the field strength of emissions from
intentional radiators shall not exceed the following:
                                                                                       Field Strength of Spurious
       Fundamental Frequency                Field Strength of Fundamental
                                                                                               Emissions
              (MHz)                             (microvolt/meter) at 3m
                                                                                        (microvolt/meter) at 3m
               40.66~40.70                                   2250                                 225
                  70~130                                     1250                                     125
                  130~174                            1250 to 3750(**)                          125 to 375(**)
                  174~260                                    3750                                     375
                  260~470                           3750 to 12500(**)                         375 to 1250(**)
                Above 470                                   12500                                    1250

** Linear interpolations, the formulas for calculating the maximum permitted fundamental field
strengths are as follows:
as shown in the above table, based on the average value of the measured emissions.As an
alternative, compliance with the limits in the above table may be based on the use of measurement
instrumentation with a CISPR quasi-peak detector.
The limits on the field strength of the spurious emissions in the above table are based on the
fundamental frequency of the intentional radiator. Spurious emissions shall be attenuated to the
average (or, alternatively, CISPR quasi-peak) limits shown in this table or to the general limits
shown in §15.209, whichever limit permits a higher field strength.
                                           Field              Field
             Frequency
                                         strength           strength          Detector        Measurementdistance
               (MHz)
                                          μV/m              dBμV/m
                30-88                       100                40                QP
                88-216                      150               43.5               QP
               216-960                      200                46                QP
                                                                                                           3m
              960-1000                      500                46                QP
            Above 1000                      500                54                AV
            Above 1000                     5000                74                PK

4.3.2 Test method
The measuring distance of 3m shall be used for measurements at frequency up to 1GHz and above
1 GHz. The EUT was placed on a rotating 0.8m high above ground; the table was rotated 360
degrees to determine the position of the highest radiation.
The Test antenna shall vary between 1m and 4m, Both Horizontal and Vertical antenna are set to
make measurement.
For the actual test configuration, please see the test setup photo.
4.3.3 Test Result




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                             - Page 11of 12-            Report No.: MTi170228E061




                  PK:
                                         Result                          Margin
                    Frequency                          AV Limit
                                        dBμV/m                            (dB)
                                                                                             Remark
                        MHz          Hor.      Ver.    dBμV/ m       Hor.       Ver.

                      433.92        72.28     61.95       80.8      -28.52     -38.85     Fundamental
                      867.84        55.32     43.89       60.8      -25.48     -36.91     Harmonics
                     1301.76        47.98     35.47       60.8      -32.82     -45.33      Harmonics




Remark:
If the PK measured values lower than average mode limit, the EUT shall be deemed to
meet average limits.




Tel:(86-755)88850135         Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail:mti@51mti.com
Address:1F& 3F, East Block, Hengfang Industrial Park, Xingye Road,Xixiang, Bao'an District, Shenzhen, Guangdong,P. R. China.


                                                                                     - Page 12of 12-                                   Report No.: MTi170228E061

4.4 Time of occupancy (dwell time)
4.4.1 Limit
15.231a(1)
A manually operated transmitter shall employ a switch that will automatically deactivate
the transmitter within not more than 5 seconds of being released.
4.4.2 Test method
Setup the EUT as show in the block diagram above.
Set Spectrum Analyzer Centre Frequency= Fundamental Frequency, RBW=1MHz, VBW=
1MHz, Span= 0 Hz. Sweep Time= 8 Seconds.
Setup the EUT as normal operation and press Transmitter button.
Release the button, use Delta Mark function to test the time.
4.4.3 Test Result

            Release Time(s)                                                     Limit(s)                                                            Result
                     0.288                                                              5                                                           PASS
                                                                                      RBW    1   MHz   Delta    1       [T1    ]
                                                                                     * VBW   1   MHz                           0.18     dB
                                 Ref   90    dBµV            * Att   10   dB          SWT    8   s              288.000000              ms

                                 90                                                                    Marker       1    [T1       ]
                                                                                                                          37.65        dBµV
                                                                                                                        1.528000        s      A
                                 80
                                                                                                                                              SGL
                        1 PK *
                        CLRWR
                                 70


                                                                                                                                              TDF
                                 60



                                 50



                                 40                  1   1


                                                                                                                                              3DB
                                 30



                                 20



                                 10



                                 0


                                 -10

                                 Center     433.92   MHz                       800   ms/




                        Date: 14.MAR.2017                02:41:17




                                                             ----END OF REPORT----