18_ESWD16 RFExp

FCC ID: 2AB22-ESWD16

RF Exposure Info

Download: PDF
FCCID_4342537

                                     MPE REPORT

                                        FCC ID: 2AB22-ESWD16


                                     Date of issue: June 03, 2019



       Report Number:                             MTi190531E195


       Sample Description:                        Smart WiFi Dimmer Switch


       Model(s):                                  ESWD16


       Applicant:                                 Etekcity Corporation


       Address:
                                                  1202 N Miller St. Suite A, Anaheim, CA 92806, USA



       Date of Test:                              May 20, 2019 to June 03, 2019




                                         Shenzhen Microtest Co., Ltd.
                                                http://www.mtitest.com




This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen
Microtest Co., Ltd.

  Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
  Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                         - Page 2 of 4 -                       Report No.: MTi190531E195




                                        TEST RESULT CERTIFICATION
Applicant’s name:                             Etekcity Corporation
Address:                                      1202 N Miller St. Suite A, Anaheim, CA 92806, USA
Manufacture's Name:                           Dongguan Raiwee Electronic Technology Co., Ltd
Address:                                      Building 11, Antouling, Industry Avenue, Qinghu Village, Qishi
                                              Town, Dongguan, Guangdong, China
Product name:                                 Smart WiFi Dimmer Switch
Trademark:                                    ETEKCITY
Model and/or type reference .. : ESWD16
Serial Model.................................. : N/A
RF Exposure Procedures........ : KDB 447498 D01 v06


This device described above has been tested by Shenzhen Microtest Co., Ltd and the test results
show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is
applicable only to the tested sample identified in the report.




                     Tested by:


                                                                Jone Lee                            June 03, 2019


                    Reviewed by:


                                                                Blue Zheng                          June 03, 2019

                  Approved by:

                                                                Smith Chen                          June 03, 2019




  Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
  Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 3 of 4 -                        Report No.: MTi190531E195

RF EXPOSURE EVALUATION
According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment
impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b)



Limits for Maximum Permissible Exposure (MPE)




MPE Calculation Method



Friis transmission formula: Pd= (Pout*G)\ (4*pi*R2)
Where

Pd= Power density in mW/cm2

Pout=output power to antenna in mW

G= Numeric gain of the antenna relative to isotropic antenna

Pi=3.1415926

R= distance between observation point and center of the radiator in cm(20cm)

Pd the limit of MPE, 1mW/cm2. If we know the maximum gain of the antenna and total power input to the
antenna, through the calculation, we will know the distance where the MPE limit is reached.




 Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 4 of 4 -                        Report No.: MTi190531E195




    Measurement Result

WIFI:
Operation Frequency: WIFI 802.11b/g/n HT20: 2412-2462MHz,

                        Power density limited: 1mW/ cm2

Antenna Type: Wifi Antenna: Spring Antenna;
WIFI antenna gain: 0.66dBi

R=20cm

mW=10^(dBm/10)

antenna gain Numeric=10^(dBi/10)= 10^(0.66/10)=1.16



                                                                                                                      Power
                            conducted     Tune-up                                              Evaluation result
                                                                Max              Antenna                              density
                              power        power                                                   at 20cm
 Channel                                                                                                               Limits
   Freq.     modulation                                   tune-up power            Gain
  (MHz)                                                                                             Power
                              (dBm)        (dBm)
                                                        (dBm)         (mW)       Numeric      density(mW/cm2 )      (mW/cm2)
                              Ant A         Ant A       Ant A         Ant A        Ant A             Ant A
   2412                       15.08        14.5±1        15.5     35.481339        1.16            0.00819               1
   2437       802.11b         13.98        14.5±1        15.5     35.481339        1.16            0.00819               1
   2462                       14.88        14.5±1        15.5     35.481339        1.16            0.00819               1
   2412                        12.1         13±1         14       25.118864        1.16            0.00580               1
   2437       802.11g         13.99         13±1         14       25.118864        1.16            0.00580               1
   2462                       12.96         13±1         14       25.118864        1.16            0.00580               1
   2412                       11.24         11±1         12       15.848932        1.16            0.00366               1
              802.11n
   2437                       10.48         11±1         12       15.848932        1.16            0.00366               1
                H20
   2462                       10.84         11±1         12       15.848932        1.16            0.00366               1


Conclusion:

For the max result: 0.00819≤ 1.0 for 1g SAR, No SAR is required.



                                                 ----END OF REPORT----




 Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China



Document Created: 2019-06-24 08:54:07
Document Modified: 2019-06-24 08:54:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC