                                         MPE REPORT

                                           FCC ID: 2AB22-ESW10-USA


                                           Date of issue: Sept. 26, 2019



       Report number:                   MTi19082802-2E2


       Sample description:              Etekcity Voltson Mini Smart WiFi Outlet


       Model(s):                        ESW10-USA


       Applicant:                       Etekcity Corporation


       Address:                         1202 N Miller St. Suite A, Anaheim, CA 92806, USA


       Date of test:                    Sept. 03, 2019 to Sept. 26, 2019




                                         Shenzhen Microtest Co., Ltd.
                                                http://www.mtitest.com




This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen
Microtest Co., Ltd.

  Tel:(86-755)88850135            Fax: (86-755) 88850136                   Web: http://www.mtitest.com           E-mail: mti@51mti.com
  Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 2 of 4 -                      Report No.: MTi19082802-2E2




                                          TEST RESULT CERTIFICATION
Applicant’s name:                        Etekcity Corporation
Address:                                 1202 N Miller St. Suite A, Anaheim, CA 92806, USA
Manufacture's name:                      Dongguan Raiwee Electronic Technology Co., Ltd
Address:                                 Building 11, Antouling, Industry Avenue, Qinghu Village, Qishi
                                         Town, Dongguan, Guangdong 523000, China
Product name:                            Etekcity Voltson Mini Smart WiFi Outlet
Trademark:                               ETEKCITY
Model and/or type reference . : ESW10-USA
Serial model ........................... : N/A
RF exposure procedures ....... : KDB 447498 D01 v06


This device described above has been tested by Shenzhen Microtest Co., Ltd and the test results
show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is
applicable only to the tested sample identified in the report.




                    Tested by:


                                                                 Danny Xu                            Sept. 26, 2019


                   Reviewed by:


                                                                 Blue Zheng                          Sept. 26, 2019

                 Approved by:

                                                                 Smith Chen                          Sept. 26, 2019




  Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
  Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


            Microtest
            M M ts H                                      — Page 3 of 4 —                      Report No.: MTi19082802—2E2

RF EXPOSURE EVALUATION
According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b)



Limits for Maximum Permissible Exposure (MPE)

 Frequency range         [Electric fieldstrength.      Magnetic field strength      |POWe! density |averaging time
 (mHz)                   (Wm)                          (Amm)                        (mWiem)            (minutes)
                                      (A) Limits for Occupational/Controlled Exposure
 o 330                                            614                          1e3               *00                  8
 Boso                                           teazn                         4 cor            ~sowr?                 s
 20—300                                           614                         a.163                1.0                s
 oo1 amo                                                                                         woo                  8
 1,200—100 500                                                                                       s                s
                                 (B) Limits for General Population/UncontrolledExposure
 o3134                                            614                          163               ~100                E
 13030                                           sn                           2 19             en                    30
 so—zo0                                           ars                         o o73                02                5o
 soo1 50o                                                                                       #1500                a
 1500—100 poo                                                                                      C                 Eq
    1= frequency in MHz *= Plane—wave equnalent power density



MPE Calculation Method

Friis transmission formula: Pd= (Pout*G)\ (4pi*R®)

Where

Pd= Power density in mW/cm2

Pout=output power to antenna in mW

G= Numeric gain of the antenna relative to isotropic antenna

Pi=3.1415926

R= distance between observation point and center of the radiator in cm{20cm)

Pd the limit of MPE, 1mW/cm2. If we know the maximum gain of the antenna and total powerinput to
the antenna, through the calculation, we will know the distance where the MPE limit is reached.




 Tel:(86—755)88850 135        Fax: (86—755) saet so136               Web: hitpiwww.mttest.com            E—mail mti@§1mti.com
 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


                                                       - Page 4 of 4 -                      Report No.: MTi19082802-2E2




    Measurement Result

WIFI:

Operation Frequency: WIFI 802.11b/g/n HT20: 2412-2462MHz,

                           Power density limited: 1mW/ cm2

Antenna Type: Wifi Antenna: Metal Antenna;
WIFI antenna gain: -0.03dBi

R=20cm

mW=10^(dBm/10)

antenna gain Numeric=10^(dBi/10)= 10^(-0.03/10)=0.99



                                          Tune-                                                                           Power
                         conducted                                                Antenn          Evaluation result
                                           up                  Max                                                        density
                           power                                                    a                 at 20cm
 Chann                                    power                                                                            Limits
             modul
 el Freq.                                               tune-up power             Gain
             ation                                                                                  Power
  (MHz)                     (dBm)         (dBm)                                  Numeri                                   (mW/c
                                                       (dBm)        (mW)                       density(mW/cm2)
                                                                                    c                                      m2)
                            Ant A         Ant A        Ant A        Ant A         Ant A                Ant A
  2412                      14.06         14±1          15         31.622         0.99                0.00625                 1
              802.1
  2437                      14.38         14±1          15         31.622         0.99                0.00625                 1
               1b
  2462                      13.65         14±1          15         31.622         0.99                0.00625                 1
  2412                      11.93         12±1          13         19.953         0.99                0.00394                 1
              802.1
  2437                      13.42         13±1          14         25.119         0.99                0.00496                 1
               1g
  2462                      10.89         11±1          12         15.849         0.99                0.00313                 1
  2412        802.1         12.40         12±1          13         19.953         0.99                0.00394                 1
  2437         1n           11.57         12±1          13         19.953         0.99                0.00394                 1
  2462         H20          10.82         11±1          12         15.849         0.99                0.00313                 1


Conclusion:

For the max result: 0.00625≤ 1.0 for 1g SAR, No SAR is required.



                                                 ----END OF REPORT----