User Manual

FCC ID: 2AB22-ESB40

Users Manual

Download: PDF
FCCID_3328143

Caution: The user is cautioned that changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be           Bluetooth Personal Scale
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
                                                                                                              iB-1 SERIES Instructions for Use
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
   connected.
-- Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be
installed and operated with a minimum distance of 20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.


                                                                                                                         Start here!




The product picture is indicative only. Appearance specifications please in kind prevail.   14iB-001E R0                                   ISO 9001 CERTIFIED BY SGS


                                                                                                      BATTERY INSTALLATION
   DEAR USERS:
Thanks for using our Smart Bluetooth scale! To make sure data correctness and product service
                                                                                                         2x1.5V AAA
life, please read the instruction manual carefully before use, and keep for later reference.
                                                                                                         Battery



                                                                                                                                                                        A. Take out the used battery with
    ABOUT SENSSUN BLUETOOTH SCALE                                                                                                                                          the aid of a cuspidal object
                                                                                                         1x3V or 2x3V lithium                                           B. Install new battery by putting
Bluetooth personal scales help you to store and keep track of your weight on your smart phone.                                                                             one side of the battery beneath
                                                                                                         battery(CR2032)                                                   the battery baffle and then
This scale can transmit your weight data to your mobile device via Bluetooth technology, as well                                                                           pressing down the other side.
                                                                                                                                                 battery baffle            Please take note to the polarity.
as make graph of your weight results, from which you are able to keep track of the trend anytime.
Download SENSSUN scale software to use Bluetooth scale, you will start your first step of weight
control.                                                                                            Note: Please use corresponding battery. Please remove battery if it is not inuse in a long time
                                                                                                    (more than three months).


   KEY FUNCTIONS:                                                                                      TO CONVERT WEIGHT UNIT
                                                                                                    If the scale is with both measuring system of Metric(kilograms) and Imperial (pounds, stones),
● Directly check personal weight information through graphs;                                        you can convert weight unit as follow:
● Set password to protect personal information and store multi-user data;
                                                                                                                                       Condition 1: if the unit switch is on the back of the scale,
● Simply and clearly graph the tendency of weight and BMI, from which you
  are able to keep track of the change.                                                                                                A. Find unit switch on the back of scale.




                                                                                                                            kg/lb/st
● Bluetooth wireless technology;                                                                          Battery                      B. Pull up and down the unit switch to convert scale
                                                                                                          Cover
● Connect with different smart devices respectively.                                                                                      unit between kg-lb-st.

                                                                                                                    Unit switch


                                                                                                      AUTOMATIC SWITCH OFF
                                 Condition 2: if the unit switch is on the back of the scale,
                                                                                                                  Auto shut-off occurs after display shows the same weight reading
                                 A. Find unit switch on the back of scale.
                                                                                                                  for approximate a few seconds, if it is not in use.
                                 B. Press the unit conversion button when scale
                                    is power on, LCD shows current weight unit.
       Unit button
                                    Press the button again to convert weight unit.

                                                                                                      COMMON WARNING INDICATION

   REGULAR WEIGHING MODE
After installing battery, place the scale on at oor. Keep stand still on scale when testing.
Then wait for seconds, display shows the same weight reading for approximate a few seconds.




                                                                                                      ADVISE FOR USE & CARE




                                                                          Reading result will flash
                                                                          after weight stabilized.




                                                                                                                                         4


   FAQ

The software can't obtain weighing results from Bluetooth scale.
● Please confirm the Bluetooth icon on the software interface is in dark blue, showing
 connected successfully.
● Confirm the Bluetooth is on in your device.
● Confirm the Bluetooth scale is on within the valid range of signal coverage.
● Check the battery of Bluetooth scale, replace it if necessary.
● Restart your device and set up Bluetooth connection.



Fail to connect to your device
● Please make sure only one device is setting up connection with the Bluetooth scale.
● Please make sure your device is equipped with Bluetooth 4.0 or above.



LCD has no responses
● Please first check the batteries and replace them if necessary.
● Repairs may only be carried out by our autherized custormer service or dealers.




                                                5                                        6



Document Created: 2017-03-10 09:41:46
Document Modified: 2017-03-10 09:41:46

© 2024 FCC.report