                      RF EXPOSURE
                       REPORT

                       FCC ID: 2AB22-EM-SF3


                      Date of issue: May 24, 2019

Report Number:              MTi190522E135


Sample Description:         Shiatsu Foot Massager



Model(s):                   EM-SF3


Applicant:                  Etekcity Corporation


Address:                    1202 N Miller St. Suite A, Anaheim, CA 92806, USA


Date of Test:               Mar. 07, 2019 to May 24, 2019


                                            - Page 2 of 4 -             Report No.: MTi190522E135




                               TEST RESULT CERTIFICATION
Applicant’s name:                Etekcity Corporation
Address:                         1202 N Miller St. Suite A, Anaheim, CA 92806, USA
Manufacture's name:              SHENZHEN MONDIAL TECHNOLOGY CO., LTD
                                 #92 Zhu Gushi Rd, Wulian Community, Longgang Str, Longgang
Address:
                                 District, Shenzhen, China
Product name:                    Shiatsu Foot Massager
Model and/or type reference:     EM-SF3
Serial Model:                    N/A

RF Exposure Procedures:          KDB 447498 D01 v06
This device described above has been tested by Shenzhen Microtest Co., Ltd and the test results
show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is
applicable only to the tested sample identified in the report.




                 Tested by:


                                                     Jone Lee            May 24, 2019


                Reviewed by:


                                                     Blue Zheng          May 24, 2019


                Approved by:


                                                     Smith Chen          May 24, 2019


                                            - Page 3 of 4 -                Report No.: MTi190522E135


1. Standalone SAR test exclusion considerations
Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or
body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement
or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold
condition(s), listed below, is (are) satisfied.
These test exclusion conditions are based on source-based time-averaged maximum conducted
output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum
test separation distance required for the exposure conditions.
The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from
the antenna and radiating structures or outer surface of the device, according to the host form factor,
exposure conditions and platform requirements, to any part of the body or extremity of a user or
bystander.
To qualify for SAR test exclusion, the test separation distances applied must be fully explained and
justified, typically in the SAR measurement or SAR analysis report, by the operating configurations
and exposure conditions of the transmitter and applicable host platform requirements, according to
the required published RF exposure KDB procedures.
When no other RF exposure testing or reporting are required, a statement of justification and
compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR
test exclusion.
When required, the device specific conditions described in the other published RF exposure KDB
procedures must be satisfied before applying these SAR test exclusion provisions.
a)   For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test
     exclusion thresholds are determined by the following:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR,where
      f(GHz) is the RF channel transmit frequency in GHz
      Power and distance are rounded to the nearest mW and mm before calculation
      The result is rounded to one decimal place for comparison
      The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and
for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion.

b)   For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test
     exclusion thresholds are determined by the following (also illustrated in Appendix B):
      1)    {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50
            mm)·(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz
        2) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50
            mm)·10]} mW, for > 1500 MHz and ≤ 6 GHz
c)   For frequencies below 100 MHz, the following may be considered for SAR test exclusion (also
     illustrated in Appendix C):
      1)   For test separation distances > 50 mm and < 200 mm, the power threshold at the
           corresponding test separation distance at 100 MHz in step b) is multiplied by [1 +
           log(100/f(MHz))]
      2)   For test separation distances ≤ 50 mm, the power threshold determined by the equation in c)
           1) for 50 mm and 100 MHz is multiplied by ½
      3)   SAR measurement procedures are not established below 100 MHz.


                                          - Page 4 of 4 -              Report No.: MTi190522E135

When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation
requirements for any SAR test results below 100 MHz to be acceptable.



2. SAR Test Exclucsion Thresholds
We use 5mm as separation distance to calculated.


Bluetooth DTS:

 Transmit                    Measured      Tune-up      Max tune-up     Result
Frequency        Mode         Power         power                                   1g SAR
  (GHz)                       (dBm)         (dBm)       power(dBm)    calculation

   2.402                       -2.3         -3±1            -2         0.1956         3

   2.44          GFSK          -2.58        -3±1            -2         0.1971         3

   2.48                        -3.43        -3±1            -2         0.1987         3




Conclusion:

For the max result : 0.1987≤ 3.0 for 1g SAR, No SAR is required.

                                       ----END OF REPORT----